• Title/Summary/Keyword: 예상 수요

Search Result 8,242, Processing Time 0.041 seconds

A Research on Effective Combination of Elementary Math and Game (초등수학과 게임의 효과적인 접목을 위한 연구)

  • Kim, Ge-won
    • Cartoon and Animation Studies
    • /
    • s.37
    • /
    • pp.393-411
    • /
    • 2014
  • The volume of world market for serious game in year 2015 is expected to be about 9.6 trillion, and the volume of educational serious game market is expected to surpass half of the whole serious game market. In Korea, the development of game for educational purpose has dominated around the education enterprises since late 90s. In 2008, 'Serious Game Forum' was founded led by the Ministry of Culture, Sports, and Tourism with experts from many fields in the society and there were progressing of making policies and plans for potential development of the serious game industry, but the effects were not successful than expected. In 2012, the Ministry of Education, Science, and Technology announced commercialization policy of digital textbook by 2015 and the serious game for educational purpose got attention again. Then, the serious game market became more vigorous with the dispersion of smart devices.13) As a result, the serious games on the smart devices or interlocking between the online and smart devices became an important issue in development rather than the online only serious games. Math field has international competitive power through export in the educational serious game market which takes more than half of the serious game market. Therefore, developing serious game for math education is a good area to raise competitiveness in domestic and international game industries. Moreover, it has no received preferences from students and parents although it has high potential for positive change of individuals and society. The reason is that students recognize it as educational content rather than a game and they avoid it, while parents recognize it as game but not an education. This phenomenon happens because the game elements and educational elements are not properly mixed but focused only on education or emphasized only the fun factors of game when it was developed. Therefore, the purpose of this research is to suggest a direction of developing serious games effectively combining with elementary math for elementary students to get interested in math while playing games. The research will analyze the current elementary math textbooks and find contents which may be combined with the game genre that elementary students enjoy playing these days. This research received advice from serious game developers and math education expert group to reflect the inclination of elementary school students, and respond to the demands from parents and educational institutions, and suggested a direction of developing serious games for effective math education.

Expression of Matrix Metalloproteinase-9 and Tissue Inhibitor of Metalloproteinase-1 after Administration of Endotoxin in Diabetic Rats (내독소로 자극된 당뇨 쥐에서 단백분해효소와 그 억제제 발현)

  • Seo, Ki Hyun;Choi, Jae Sung;Na, Joo Ok;Uh, Soo Taek;Kim, Yong Hoon;Park, Choon Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.3
    • /
    • pp.256-264
    • /
    • 2006
  • Background: An acute lung injury(ALI) is characterized by the recruitment, activation, and apoptosis of inflammatory cells, numerous products released by inflammatory cells such as reactive oxygen species, inflammatory mediators, and a variety of proteolytic enzymes. It was reported that bacterial infections in diabetics showed impaired PMN functions such as reduced PMN respiratory burst and decreased microbicidal activity in inflamed tissue. However, the effect of the proteinase - inhibitor (MMP-9 vs TIMP-1) in ALI in diabetics is unclear. This study evaluated the differences in the expression of MMP-9 and TIMP-1 after the stimulation of endotoxin in a rat model. Methods: Six-week-old male Sprague-Dawley rats were classified into normal, DM, LPS and DM+LPS groups. The peripheral blood, BAL fluids, and lung tissues were obtained from individual rats. The MMP-9 activity was measured by gelatin zymography and the TIMP-1 level was measured by Western blotting. Results: The total BAL cells of the DM-LPS groups were significantly lower than the LPS groups (p < 0.01). The MMP-9 activities in the serum were higher in the DM+LPS groups than in the other groups. The MMP-9 activities in the BAL fluids were significantly higher in the DM+LPS group than in the normal and diabetic rats (p < 0.05). TIMP-1 expressions in the BAL fluids were significantly lower in the DM+LPS group than other groups (p < 0.05). The ratio between MMP-9 and TIMP-1 in the BAL fluids was significantly higher in the DM+LPS groups (p < 0.05). Conclusion: In ALI in diabetics the higher MMP-9 activity and lower TIMP-1 level are believed to prolonged and intensify the course of inflammation.

The Cooperative Environmental Research in the Yellow Sea between Korea and China for the Establishment of Cooperative Management Plans on the Yellows Sea Conservation (황해 공동 관리시스템 기반 조성을 위한 한.중 황해환경공동조사)

  • Heo, Seung;An, Kyoung-Ho;Park, Soung-Yun;Park, Jong-Soo;Kang, Young-Shil;Shon, Jaek-Young;Kim, Pyoung-Joong;Kim, Hyung-Chul;Hwang, Woon-Ki;Lee, Seung-Min;Hwang, Hak-Jin;Choi, Yong-Suk;Ko, Byeong-Seol;Bang, Hyun-Woo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.15 no.3
    • /
    • pp.263-268
    • /
    • 2009
  • The Yellow Sea is extremely important to the economy and to the health and well-being of surrounding countries, Korea and China. Recently, the Yellow Sea is under constantly increasing threat of degradation due to the increase of environmental pollution and over-fishing. The governments of Korea and China have been aware of the importance of the Yellow Sea and reached an Environmental Agreement between Korea and China at the governmental level(November, 1993) According to this environmental agreement the Yellow Sea Environmental Cooperative Research between Korea and China has been undertaken since 1997. The joint cruise had been conducted once a year at 33 stations in the 4 lines of the Yellow Sea where the 9 stations of the D line was newly added in the 7th cruise in 2003. The samples were analyzed by scientists of both countries at the WSFRI, Korea and the OEMNC of the SEPA, China in turn, the annual report has been published every year during 1998-2008. The scientific efforts to fix the cruise time in October and to extend research frequency, as twice a year, should be considered, and this requires the governmental supports such as research funds and other related administrational assistance on both sides. Finally, scientists should also pay a concentrated attention to standardize the analytical methods including quality control and to improve this Yellow Sea research as one of the most representative international projects in the Yellow Sea where sharing additional informations available, if exist of dumping sites and material content, and of the freshwater quality will be of great help to broaden the output of this joint research project.

  • PDF

Minor Stress, Coping Skill and Quality of Life in Patients with Hemodialysis (혈액투석 환자들의 Minor Stress, 대처방식 및 삶의 질)

  • Yang, Jae-Won;Lee, Moon-Soo;Park, Sang-Uk;Oh, So-Young;Ko, Young-Hoon;Kwan, Young-Joo;Joe, Sook-Haeng
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.16 no.1
    • /
    • pp.38-46
    • /
    • 2008
  • Objectives : The purpose of this study is to investigate the minor stress in daily life related to undergoing hemodialysis and the relationship between minor stresses, coping skills, and subjective quality of life among the patients with end stage renal disease. Methods : Seventy seven patients on hemodialysis were enrolled in this study. Minor stress was assessed with daily stress inventory-Korean version(K-DSI), ways of coping checklist identified the use of the following coping strategies:problem-focused, seek social support, emotion-focused coping and wishful thinking. Socio-demographic data were obtained and World Health Organization-Quality of Life Scale(brief form) was also administered to subjects. Results : Participants mean age was $55.92{\pm}13.71$ years. The mean of the event, impact and impact/event (I/E) ratio scores of K-DSI were $29.06{\pm}21.57$, $88.69{\pm}75.88$ and $2.92{\pm}1.11$, respectively. These scores were much higher than normative data of K-DSI. Among the 5 categories of this inventory, the scores of cognitive stressors were highest. 5 categories of the inventory showed positive relationship with way of coping subscales, which showed coefficient of correlation between 0.259(p<.01) and 0.495(p<.001). However, no significant correlation was found between minor stress subscales and quality of life. Hemodialysis patients in our study used more emotional-focused coping methods, which was considered as passive way of cope than problem-orientated coping methods. Conclusion : The main findings of this study indicated that patients on hemodialysis showed higher level of perceived minor stress than normal population. The patients treated with hemodialysis tend to use passive way of coping primarily. For assessing the stress in patients on hemodialysis, clinician has to consider both level of perceived minor stress and the ways of coping the patients primarily use.

  • PDF

Determination of Electron Beam Output Factors of Individual Applicator for ML-15MDX Linear Accelerator (선형가속기 ML-15MDX의 각 Applicator에 대한 전자선 출력선량 계수 결정)

  • Park, Tae-Jin;Kim, Ok-Bae
    • Progress in Medical Physics
    • /
    • v.5 no.1
    • /
    • pp.87-99
    • /
    • 1994
  • Purpose : The determination of electron beam output factor was investigated from individual applicator for various energy of ML-15MDX linear accelerator. The output factor of electron beam was extended from square to rectangular field in individual applicator size through with a least-square fit to a polynomial expression. Materials : In this experiments. the measurement of output was obtained from 2${\times}$cm$^2$ to 20${\times}$20cm$^2$ of field size in different applicator size for 4 to 15 MaV electron beam energy. The output factor was defined as the ratio of maximum dose output on the central axis of the field of individual applicator size to that of a given field size. Applicator factors were derived from comparing with the output dose of reference field size 10${\times}$10cm$^2$. The thickness of block was specially designed as 10mm in thickness of Lipowitz metal for field shaping in all electron energy. Two types of output curves are included as output factors versus side of square fields and that of variable side length for X and Y in one-dimensional to compare the expected values to that of experiments. Results : Expected output factors of rectangular which was derived from that of square fields in individual applicator size from 2${\times}$2cm$^2$ to 20${\times}$20cm$^2$ in different electron energy was very closed to that of experimental measurements within 2% uncertainty. However 1D method showed a 3% discrepancy in small rectangular field for low energy electron beam. Conclusion : Emperical non-linear polynomial regressions of square root and 1D method were performed to determin the output factor in various field size and electron energy. The expected output of electron beam of square root method for square field and 1D method for rectangular field were very closed to that of measurement in all selected electron beam energy.

  • PDF

The objective and quantitative analysis of malocclusion - Part 2. Influence of malocclusion components to treatment difficulty (부정교합의 객관적 정량분석: Part 2. 부정교합 요소들의 치료난이도에 미치는 영향)

  • Joo, Bo-Hoon;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.35 no.1 s.108
    • /
    • pp.69-81
    • /
    • 2005
  • As one of the variations in growth and development of the craniofacial complex. malocclusion shows lack of concordance In the recognition and severity of malocclusion for dentists as well as the acceptance and need of orthodontic treatment for the patient The purposes of this study were 1) to examine the relationships between objective malocclusion severity aid subjective treatment difficulty. 2) to evaluate the effect of malocclusion components to the subjective perceived difficulty of treatment. 3) to establish the weighted values of malocclusion components to reflect the treatment difficulty 100 pairs of dental casts with the general characteristics of malocclusion. were selected from the orthodontic departments of Kyunghee University and Samsuug Medical Center. The severity of malocclusion was evaluated by the author with the PAR index The perceived treatment difficulty and the estimated treatment duration on these dental models were evaluated by 8 experienced orthodontists. The relationships between the objective malocclusion severity and the subjective treatment difficulty were statistically evaluated. and the weighted values of malocclusion components to reflect treatment difficulty were statistically formulated. There were significant relationships between objective malocclusion severity and subjective treatment difficulty The malocclusion components which significantly affected the treatment difficulty and their weighted values in parentheses were as follows upper anterior alignment(1). overbite (2). buccal occlusion (3) middline (4), and overjet (5). This study Provides the fundamental principle to evaluate the objective malocclusion severity which is reflected by the subjective treatment difficulty of Korean orthodontists.

Performance Test of Portable Hand-Held HPGe Detector Prototype for Safeguard Inspection (안전조치 사찰을 위한 휴대형 HPGe 검출기 시제품 성능평가 실험)

  • Kwak, Sung-Woo;Ahn, Gil Hoon;Park, Iljin;Ham, Young Soo;Dreyer, Jonathan
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.1
    • /
    • pp.54-60
    • /
    • 2014
  • IAEA has employed various types of radiation detectors - HPGe, NaI, CZT - for accountancy of nuclear material. Among them, HPGe has been mainly used in verification activities required for high accuracy. Due to its essential cooling component(a liquid-nitrogen cooling or a mechanical cooling system), it is large and heavy and needs long cooling time before use. New hand-held portable HPGe has been developed to address such problems. This paper deals with results of performance evaluation test of the new hand-held portable HPGe prototype which was used during IAEA's inspection activities. Radioactive spectra obtained with the new portable HPGe showed different characteristics depending on types and enrichments of nuclear materials inspected. Also, Gamma-rays from daughter radioisotopes in the decay series of $^{235}U$ and $^{238}U$ and characteristic x-rays from uranium were able to be remarkably separated from other peaks in the spectra. A relative error of enrichment measured by the new portable HPGe was in the range of 9 to 27%. The enrichment measurement results didn't meet partially requirement of IAEA because of a small size of a radiation sensing material. This problem might be solved through a further study. This paper discusses how to determine enrichment of nuclear material as well as how to apply the new hand-held portable HPGe to safeguard inspection. There have been few papers to deal with IAEA inspection activity in Korea to verify accountancy of nuclear material in national nuclear facilities. This paper would contribute to analyzing results of safeguards inspection. Also, it is expected that things discussed about further improvement of a radiation detector would make contribution to development of a radiation detector in the related field.

A STUDY ON SOFT TISSUE FACIAL PROFILE CHANCES IN ORTHODONTIC TREATMENT WITH FOUR PREMOLAR EXTRACTIONS (4개 소구치 발치를 통한 교정치료시 나타나는 안모 연조직 변화에 관한 연구)

  • Jin, Hee-Kwan;Moon, Yoon-Shik
    • The korean journal of orthodontics
    • /
    • v.28 no.5 s.70
    • /
    • pp.825-838
    • /
    • 1998
  • The purpose of this study was to evaluate the differences of soft tissue profile changes between the growing patients and the adult who had passed the growth peak, in orthodontic treatment with four premolar extractions. The results which was taken by correlating the soft tissue changes with hard tissue changes, lip thickness, molar relationship and arch length discrepancy in both groups was like the followings. 1. Significant hard tissue changes were decrease of VIs, VIi, UlPP, LlMP, HIi and increase of HPog'in adults and decrease of VIs, VIi and increase of VA, VPog'and all the vertical measurements in adolescents. 2. Significant soft tissue changes were decrease of VLs, VLi, and VILS in adults and increase of VSn, VSLS, VLs, VPog' and almost all vertical measurements in adolescents, and ${\Delta}LsE,\;{\Denta}LiE$ in adults and ${\Delta}LsE,\;{\Denta}LiE,\;{\Delta}LiSP\;and\;{\Delta}Mang$ was also significant 3. Correlation coefficient between ${\Delta}VIs\;and\;{\Delta}VLs$ was the greatest in adults and the next was ${\Delta}Ii/{\Delta}Li,\;{\Delta}Ii/{\Delta}ILS,\;{\Delta}ID/{\Delta}Li\;and\;{\Delta}ID/{\Delta}ILS$. In contrast all the vertical and horizontal measurements of hard and soft tissue in adolescents showed statistically significant corerrlation. 4. There were differences in correlation between soft tissue changes and incisor inclination and retraction at both groups, but the lower lip, nasolabial angle and mentolabial angle were commonly less influenced by the hard tissue changes in both groups. 5. The thinner the upper lip was, the more the ${\Delta}LsSP$ was in both groups, and the thinner the lower lip was, the more the ${\Delta}LiE\;and\;{\Denta}LiSP$ was in adolescents. 6. Molar relationship didn't influence the soft tissue profile changes. 7. Arch length discrepancy didn't influence the soft tissue profile changes.

  • PDF

The Quality Characteristics of Rice Mash by Mixing Ratios of Rice and Rice Koji (쌀과 미입국의 배합비율에 따른 쌀 당화액의 품질특성)

  • Kim, Jin-Sook;Lee, Ji-Hyun;Chang, Young-Eun;Kim, Gi-Chang;Kim, Kyung-Mi
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.12
    • /
    • pp.2035-2041
    • /
    • 2013
  • The effects of Aspergillus oryzae rice koji (AO) and Asp. kawachii rice koji (AK) as enzyme preparations, on the quality characteristics of rice mash were invested in this study. The amount of AORM (Asp. oryzae rice mash) and AKRM (Asp. kawachii rice mash) were 50, 100, 200% (w/w) based on 100 g of rice. Firstly, in the titer measurement result on the ${\alpha}$-amylase and glucoamylase activities of AO and AK. On the other hand, the acid protease activity has values of 31.56 unit for AO and 849.17 unit for AK. The sugar solid of the AORM and AKRM groups significantly increased as the rice koji ratio on rice was higher, which were shown with values as high as 17.63~20.53 and 17.51~19.28, respectively. Glucose and maltose were detected for free sugar of AORM. Only glucose was found in AKRM. Citric acid, malic acid, and lactic acid were detected as the organic acid of KORM; oxalic acid, citric acid, and succinic acid were detected for AKRM, and the content increased as the rice koji ratio on rice increased (P<0.05). From the above result, rice koji with useful mold is expected to be used broadly in foods by looking at the fact that it has starch degradation ability and organic acid producibility.

The Evaluation of Scattering Effects for Various Source Locations within a Phantom in Gamma Camera (감마카메라에서의 팬텀 내 선원 위치 변화에 따른 산란 영향 평가)

  • Yu, A-Ram;Lee, Young-Sub;Kim, Jin-Su;Kim, Kyeong-Min;Cheon, Gi-Jeong;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.216-224
    • /
    • 2009
  • $^{131}I$ is a radiological isotope being used widely for treatment of cancer as emitting gamma-ray and it is also applied to estimate the function of thyroid for its accumulation in thyroid. However, $^{131}I$ is more difficult to quantitate comapred to $^{99m}Tc$, because $^{131}I$ has multiple energy gamma-ray emissions compared to $^{99m}Tc$ which is a mono energetic gamma-ray source. Especially, scattered ray and septal penetration resulted by high energy gamma ray have a bad influence upon nuclear medicine image. The purpose of this study was to estimate scatter components depending on the different source locations within a phantom using Monte Carlo simulation (GATE). The simulation results were validated by comparing with the results of real experiments. Dual-head gamma camera (ECAM, Chicago, Illinois Siemens) with high energy, general-purpose, and parallel hole collimators (hole radius: 0.17 cm, septal thickness: 0.2 cm, length: 5.08 cm) was used in this experiment. The NaI crystal is $44.5{\times}59.1\;cm$ in height and width and 0.95 cm in thickness. The diameter and height of PMMA phantom were 16 cm and 15 cm, respectively. The images were acquired at 5 different locations of $^{131}I$ point source within the phantom and the images of $^{99m}Tc$ were also acquired for comparison purpose with low energy source. The simulation results indicated that the scattering was influenced by the location of source within a phantom. The scattering effects showed the same tendency in both simulation and actual experiment, and the results showed that the simulation was very adequate for further studies. The results supported that the simulation techniques may be used to generalize the scattering effects as a function of a point source location within a phantom.

  • PDF