• Title/Summary/Keyword: 영상왜곡 보정식

Search Result 20, Processing Time 0.028 seconds

Fisheye Image Correction with Ellipsoid Model (타원체 모형을 통한 어안 영상 보정)

  • Kim, Hyun-Tae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.2
    • /
    • pp.177-182
    • /
    • 2015
  • General method for correcting the distortion caused by the characteristic of the fish-eye lens may be classified in two ways. The first method is a calibration method using a mathematical model taking into account the characteristics of the lens, the second method is a method using only the distortion correction image, regardless of the lens. When considering the characteristics of the lens, calibration equation can be calculated geometrically from the relationship between the three-dimensional real-world coordinates and two-dimensional image coordinates and the parameters of lens. However, it is not suitable for ellipsoid type lens, because of existing research papers have been corrected on the spherical-type fisheye lens. In this paper, we propose a method for correcting geometrically using fish-eye lens as an ellipsoid model. Through a calibration picture, it can be seen that the proposed method is valid.

Correction of Geometric Distortion of Internet Aerial Imagery and Photo-Realistic 3D Building Modeling (인터넷 항공영상의 왜곡보정과 실감적 3차원 건물 모델링)

  • Lee, Dong-Cheon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.29 no.6
    • /
    • pp.687-695
    • /
    • 2011
  • Many internet portals provide maps with spatial information services. Recently, various images including aerial, satellite, street view, and photo-realistic 3D city models are provided as well as maps. This study suggested a method for geometric correction of the panoramic aerial images in the internet portal and 3D building modeling using information which is available in the internet. The key of this study is to obtain all necessary data easily from internet without restrictions. Practically, the ground control coordinates could be available from geo-referenced internet maps, and stereo pairs of the aerial images and close-range photographs for photo-realistic object modeling are provided by the internet service. However, the ground control points are not suitable for accurate mapping. RMSE of the plotting was about 9 meters and reduced upto 4 meters after coordinate transformation. The proposed methods would be applicable to various applications of photo-realistic object modeling which do not require high accuracy.

Characterizing the Color Printer based on Colorimetric Model (색채학적 모델을 이용한 칼라 프린터 특성화)

  • 한규서;김홍기;강병호;윤창락;김진서;조맹섭
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1998.04a
    • /
    • pp.147-150
    • /
    • 1998
  • 다양한 응용분야에서 디지털 칼라영상은 프린터를 통ㅎ여 출력되어진다. 이러한 출력 장비들의 하드웨어적 특성은 칼라 영상의 색을 왜곡시켜 부정확한 색 재현을 얻게 된다. 본 논문에서는 색채학적 모델에 기반한 다차 비선형변환을 이용하여 주어진 칼라 프린터의 특성을 알아내고 이를 보정하는 방법을 제시한다. 또한, 샘플의 개수를 변화하면서 비선형 변환식을 계산하여 기기의 특성화 모델링 과정에 필요한 적정수준의 샘플 개수를 제시한다. 실험을 통하여 원본의 색과 재현되어진 색의 색차를 구함으로써 제시되어진 방법의 타당성을 검증한다.

  • PDF

Surface Reconstruction Using CORONA KH-4 Imagery (CORONA KH-4 영상을 이용한 3차원 지형정보 취득)

  • Sohn, Hong-Gyoo;Yeu, Bock-Mo;Kim, Gi-Hong;Choi, Jong-Hyun
    • 한국지형공간정보학회:학술대회논문집
    • /
    • 2002.03a
    • /
    • pp.145-149
    • /
    • 2002
  • CORONA는 미국이 1960년에서 1972년까지 냉전시대 관심지역에 대한 첩보영상을 취득하기 위하여 운영한 영상취득시스템으로 1995년 일반에 자료가 공개됨에 따라 과거의 고해상도 영상자료를 이용할 수 있는 길이 열리게 되었다. 그러나 현재까지 CORONA 영상처리를 위한 모듈을 제공하는 원격탐측 소프트웨어가 개발되어 있지 않기 때문에 CORONA 영상을 이용하여 수치표고모형이나 정사영상을 제작하기 위해서는 적절한 모델링 방법이 필요하다. CORONA 영상은 파노라마 영상으로 필름 가장자리로 갈수록 왜곡이 많이 생기며 사진기 지표가 없고 위성의 궤도와 위치, 자세, 속도, IMC(Image Motion Compensation)에 대한 자세한 자료를 제공하지 않는 문제점이 있다. 따라서 본 논문에서는 지형복원을 위하여 지상기준점을 이용하는 2가지 모델링 방법을 이용하였다. 첫 번째는 파노라마 왜곡과 촬영 비행체 이동에 의한 왜곡, IMC에 의한 왜곡을 보정하는 모형식을 구성하여 이용하였으며, 두 번째는 위성과 센서에 대한 정보를 필요로 하지 않는 다항식비례모형(RFM; Rational Function Model)을 이용하였다. 대상지역은 서울지역의 입체영상으로 대략 $33km{\times}26km$ 지역이다. 영상은 지상해상도 약 2.7m로 스캐닝하였고 1:1000 수치지도를 통해 20개의 기준점과 36개의 검사점을 관측하였다. 검사점의 위치정확도를 평가해 본 결과 첫 번째 방법은 수평방향으로 평균 3.9m(X), 2.8m(Y)의 오차를 보였으며 표고의 경우 4.2m의 오차를 보여주었다. 두 번째 방법은 수평방향으로 평균 3.2m(X), 2.8m(Y)의 오차를 보였으며 표고의 경우 5.5m의 오차를 보여주었다. 지형복원 정확도를 검증하기 위하여 첫 번째 방법을 이용하여 대상지역 중 일부인 서울 남산지역에 대해 정사영상과 10m간격의 DEM을 제작하였으며 1:1000 수치지도를 통해 제작된 DEM과 비교한 결과 총 43990개 격자점의 표고 차이는 평균 5.98m였다.

  • PDF

Extraction of Urban Boundary Using Grey Level Co-Occurrence Matrix Method in Pancromatic Satellite Imagery (GLCM기법을 이용한 전정색 위성영상에서의 도시경계 추출)

  • Kim, Gi Hong;Choi, Seung Pil;Yook, Woon Soo;Sohn, Hong Gyoo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.1D
    • /
    • pp.211-217
    • /
    • 2006
  • Growing urban areas modify patterns of local land use and land cover. Land use changes associated with urban expansion. One way to understand and document land use change and urbanization is to establish benchmark maps compiled from satellite imagery. Old satellite Imagery is useful data to extract urban information. CORONA is a photo satellite reconnaissance program used from 1960 to 1972 and its imagery was declassified and has been available to the public since 1995. Since CORONA images are collected with panoramic cameras, several types of geometric distortions are involved. In this study we proposed mathematical modeling method which use modified collinearity equations. After the geometric modeling, we mosaicked images. We can successfully extract urban boundaries using GLCM method and visual interpretation in CORONA (1972) and SPOT (1995) imagery and detect urban changes in Seoul quantitatively.

A Study of Data Management Methods through Shake Correction of Underwater Investigation Using High Resolution Side Scan SONAR (흔들림 보정을 통한 고해상 사이드스캔소나의 데이터 관리기법 연구)

  • Yi, Jong-Hwa;Kim, Young-Seok;Park, Chul;Choi, Sang-Sik;Lee, Heung-Su
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.5
    • /
    • pp.94-100
    • /
    • 2017
  • In the case of the side scan sonar operated by the towing method, the underwater structure electric jig was developed because there is a difficulty in the cross-sectional survey that the user wants when conducting the survey. However, in the case of the sound wave photographing method using the electric jig, since the boat and the sonar behaves as one body, data distortion has occurred due to various problems according to working environment, such as, the rolling phenomenon of the boat due to the wave and the fluctuation of the sonic image due to the inoperability of the boat driver. Therefore, in order to solve the image blurring caused by the operation of the equipment for underwater survey of the existing side scan sonar, in this research, the program was supplemented to enable the shake correction by attaching the shake correction sensor and developing the shake correction algorithm. In order to verify the improvement of the sonar data resolution, the sonic images before and after the shake correction were collected through on-site investigation and the analysis of the sonic image data acquired by a diver measuring the actual damage length and depth. This study is expected to contribute to the development of sonar imaging technique of the underwater surface of the structure and bed surface of the sea or a river using the side scan sonar in the future.

Multi-camera Calibration Method for Optical Motion Capture System (광학식 모션캡처를 위한 다중 카메라 보정 방법)

  • Shin, Ki-Young;Mun, Joung-H.
    • Journal of the Korea Society of Computer and Information
    • /
    • v.14 no.6
    • /
    • pp.41-49
    • /
    • 2009
  • In this paper, the multi-camera calibration algorithm for optical motion capture system is proposed. This algorithm performs 1st camera calibration using DLT(Direct linear transformation} method and 3-axis calibration frame with 7 optical markers. And 2nd calibration is performed by waving with a wand of known length(so called wand dance} throughout desired calibration volume. In the 1st camera calibration, it is obtained not only camera parameter but also radial lens distortion parameters. These parameters are used initial solution for optimization in the 2nd camera calibration. In the 2nd camera calibration, the optimization is performed. The objective function is to minimize the difference of distance between real markers and reconstructed markers. For verification of the proposed algorithm, re-projection errors are calculated and the distance among markers in the 3-axis frame and in the wand calculated. And then it compares the proposed algorithm with commercial motion capture system. In the 3D reconstruction error of 3-axis frame, average error presents 1.7042mm(commercial system) and 0.8765mm(proposed algorithm). Average error reduces to 51.4 percent in commercial system. In the distance between markers in the wand, the average error shows 1.8897mm in the commercial system and 2.0183mm in the proposed algorithm.

Studies on the acquisition of CONV and IOD according to the distance for long-distance 3D stereoscopic video shooting (원거리 3D 입체영상촬영을 위한 거리에 따른 IOD와 CONV의 획득에 관한 연구)

  • Kim, Hyun-jo;Kim, Min;Son, Kyung-Min;Kim, Kwan hyung;Byun, Gi-sik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.10a
    • /
    • pp.919-921
    • /
    • 2013
  • 영상시장의 개척과 디지털 기술의 발전과 더불어 차세대 3D 입체영상기술에 대한 관심과 수요가 증가하고 있다. 입체 정보는 크게 '단안 입체 정보(monoscopic depth cue)'와 '양안 입체 정보(stereoscopic depth cue)'로 분류 할 수 있다. 단안 입체 정보는 은폐, 상대적 크기, 상대적 밀도, 시야 안의 높이, 공기투시, 운동투시, 초점조절인 7가지로 경험에 의한 입체감을 지각하는 것을 말하며 양안 입체 정보는 두 눈으로 볼 때 처음으로 깊이를 지각 할 수 있는 것으로 크게 '동시시(simultaneous perception)', '융합(sensory fusion)', '입체시(stereoscopic vision)'의 세종류의 기능으로 분류한다. 3D 촬영은 이 양안시의 원리를 이용하여 두 대의 카메라의 좌우 영상을 합성하여 깊이감 있는 영상을 만들어 내게 된다. 본 논문에서는 3D 촬영방법은 촬영방식에 따라 크게 평행방식, 직교방식, 교차방식이 있는데 이중 중 원거리 촬영에 유리한 교차방식을 활용하여 사이드 바이 사이드 리그(Rig; 카메라를 수평으로 설치할 수 있도록 만들어진 장치)를 원거리 촬영에 맞게 축간거리를 기존의 리그 사이즈보다 2배 이상 긴 리그를 제작하여 보다 먼 거리에서의 상이한 좌우 영상획득이 가능하도록 설계하였다. 또한, 일정한 간격에 따라 피사체를 촬영하면서 거리에 따른 양 카메라의 가장 이상적인 IOD(Interocular Distance)와 CONV(Convergence)를 찾고, 교차방식촬영에 따른 특징적인 아티팩트인 키스톤 왜곡(Keystone distance)의 보정을 통한 원거리 입체영상을 효과적으로 획득하는데 본 연구방법을 제안하고자 한다.

  • PDF

The Study on image correction of geometric distortion in digital radiography image (방사선투과영상의 기하학적 왜곡 보정에 관한 연구)

  • Park, S.K.;Ahn, Y.S.;Gil, D.S.
    • Journal of Power System Engineering
    • /
    • v.15 no.4
    • /
    • pp.25-30
    • /
    • 2011
  • This study is made to provide with a method for correcting the geometric distortion of the digital radiography image by analytical approach based upon the inverse square law and Beer's law. This study is aimed to find out and improve a mathematic model of nonlinear type. Variations in the alignment of the X-ray source, the object, and imaging plate affect digital radiography images. A model which is expressed in parameter values; e.g, angle, position, absorption coefficient, length, width and pixel account of radiography source, is developed so as to match the sample image. For the best correction of the digital image that is the most similar to the model image, a correction technique based upon tangent is developed; then applied to the digital radiography images of steel tubes. As a result, the image correction is confirmed to be made successfully.

Analysis of Respiratory Motional Effect on the Cone-beam CT Image (Cone-beam CT 영상 획득 시 호흡에 의한 영향 분석)

  • Song, Ju-Young;Nah, Byung-Sik;Chung, Woong-Ki;Ahn, Sung-Ja;Nam, Taek-Keun;Yoon, Mi-Sun
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.81-86
    • /
    • 2007
  • The cone-beam CT (CBCT) which is acquired using on-board imager (OBI) attached to a linear accelerator is widely used for the image guided radiation therapy. In this study, the effect of respiratory motion on the quality of CBCT image was evaluated. A phantom system was constructed in order to simulate respiratory motion. One part of the system is composed of a moving plate and a motor driving component which can control the motional cycle and motional range. The other part is solid water phantom containing a small cubic phantom ($2{\times}2{\times}2cm^3$) surrounded by air which simulate a small tumor volume in the lung air cavity CBCT images of the phantom were acquired in 20 different cases and compared with the image in the static status. The 20 different cases are constituted with 4 different motional ranges (0.7 cm, 1.6 cm, 2.4 cm, 3.1 cm) and 5 different motional cycles (2, 3, 4, 5, 6 sec). The difference of CT number in the coronal image was evaluated as a deformation degree of image quality. The relative average pixel intensity values as a compared CT number of static CBCT image were 71.07% at 0.7 cm motional range, 48.88% at 1.6 cm motional range, 30.60% at 2.4 cm motional range, 17.38% at 3.1 cm motional range The tumor phantom sizes which were defined as the length with different CT number compared with air were increased as the increase of motional range (2.1 cm: no motion, 2.66 cm: 0.7 cm motion, 3.06 cm: 1.6 cm motion, 3.62 cm: 2.4 cm motion, 4.04 cm: 3.1 cm motion). This study shows that respiratory motion in the region of inhomogeneous structures can degrade the image quality of CBCT and it must be considered in the process of setup error correction using CBCT images.

  • PDF