Effect of Scatter Media on Small Gamma Camera Imaging Characteristics (방사선원과 감마카메라 사이에 위치한 산란매질이 소형 감마카메라 영상에 미치는 영향 연구)

  • Seo, Hyun-Kwan;Choi, Yong;Im, Ki-Chun; Woo, Sang-Geun;Lee, Jun-Soo;Song, Tae-Yong;Choi, Yeon-Sung;Lee, Kyung-Han;Kim, Byung-Tae;Choi, Young-Il
    • Progress in Medical Physics
    • /
    • v.13 no.1
    • /
    • pp.37-43
    • /
    • 2002
  • Effect of scatter media materials and thickness, located between radioactivity and small gamma camera, on imaging characteristics was evaluated. The small gamma camera developed for breast imaging was consisted of collimator, NaI(T1) crystal(60$\times$60$\times$6 ㎣), PSPMT(position sensitive photomultimplier tube), NIMs and personal computer. Monte Carlo simulation was performed to evaluate the system sensitivity with different scatter media thickness(0~8 cm) and materials(air and acrylic) with parallel hole collimator and diverging collimator. The sensitivity and spatial resolution was measured using the small gamma camera with the same condition applied to the simulation. Counts was decreased by 10%(air) and 54%(acryl) with the parallel hole collimator and by 35%(air) and 63%(acryl) with the diverging collimator. Spatial resolution was decreased as increasing the thickness of scatter media. This study substantiate the importance of a gamma camera positioning and the minimization of the distance between detector and target lesion in the clinical application of a gamma camera.

  • PDF

An Evaluation Method of X-ray Imaging System Resolution for Non-Engineers (비공학도를 위한 X-ray 영상촬영 시스템 해상력 평가 방법)

  • Woo, Jung-Eun;Lee, Yong-Geum;Bae, Seok-Hwan;Kim, Yong-Gwon
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.309-314
    • /
    • 2012
  • Nowadays, digital Radiography (DR) systems are widely used in clinical sites and substitute the analog-film x-ray imaging systems. The resolution of DR images depends on several factors such as characteristic contrast and motion of the object, the focal spot size and the quality of x-ray beam, x-ray scattering, the performance of the DR detector (x-ray conversion efficiency, the intrinsic resolution). The DR detector is composed of an x-ray capturing element, a coupling element and a collecting element, which systematically affect the system resolution. Generally speaking, the resolution of a medical imaging system is the discrimination ability of anatomical structures. Modulation transfer function (MTF) is widely used for the quantification of the resolution performance for an imaging system. MTF is defined as the frequency response of the imaging system to the input of a point spread function and can be obtained by doing Fourier transform of a line spread function, which is extracted from a test image. In clinic, radiologic technologists, who are in charge of system maintenance and quality control, have to evaluate or make routine check on their imaging system. However, it is not an easy task for the radiologic technologists to measure MTF accurately due to lack of their engineering and mathematical backgrounds. The objective of this study is to develop and provide for radiologic technologists a medical system imaging evaluation tool, so that they can measure and quantify system performance easily.

The East-Asian VLBI Network: Recent Progress and Results of the First Imaging Test Observation (동아시아VLBI관측망의 현황과 영상합성 시험관측 결과)

  • Wajima, Kiyoaki;Roh, Duk-Gyoo;Oh, Se-Jin;Jung, Taehyun;Kim, Jongsoo;Hagiwara, Yoshiaki;Hada, Kazuhiro;Kawaguchi, Noriyuki;Kobayashi, Hideyuki;Wu, Yuanwei;Fujisawa, Kenta;An, Tao;Baan, Willem A.;Jiang, Wu;Shen, Zhi-Qiang;Xia, Bo;Zhang, Ming;Hao, Longfei;Wang, Min
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.58.3-59
    • /
    • 2016
  • 동아시아 VLBI 관측망(the East-Asian VLBI Network; EAVN)은 한 중 일 각국의 전파망원경을 통합해서 구성되는 동아시아 지역의 새로운 VLBI 관측망이다. EAVN의 주된 관측주파수는 6.7, 8, 22, 43 GHz이고 최고 공간분해능은 약 0.6 mas이다. 우리는 EAVN의 성능검증을 목적으로 하는 국제연구팀을 구성하고 2013년부터 2015년까지 주로 8, 22 GHz로의 프린지검출 시험관측을 실행해왔다. 이들의 결과에 의거해서 작년말부터 앞으로의 EAVN 어레이 공개를 목표로 할 영상합성 시험관측을 시작하였다. 첫 번째 시험관측은 한 중 일 9개의 안테나를 이용해서 2015년12월13일에 8 GHz로 실시하였다, 관측 천체는 밝은 활동성 은하핵인 4C 39.25이고, 국제간 기선에서 성공적으로 프린지를 검출하였다. 우리는 올해부터 100 시간 이상을 이용해서 상기 네 주파수로의 영상합성 시험관측을 실시할 계획이고, 2017년 후반기부터 부분적인 공개관측을 시작할 예정이다. 이 발표에서는 주로 EAVN의 현황과 상기 영상합성 시험관측의 결과에 관해서 보고한다.

  • PDF

Aperture Correction using Distance-Dependent Backprojection for SPECT Images (거리 의존적 역투사를 이용한 SPECT 영상 구경보정)

  • Lee, Nam-Yong
    • Journal of Korea Multimedia Society
    • /
    • v.11 no.4
    • /
    • pp.434-442
    • /
    • 2008
  • The parallel beam SPECT acquires projection data by using parallel hole collimators in conjunction with photon detectors. Those projection data of the parallel beam SPECT are, however, contaminated by the distance dependent blurring because of the inaccuracy of the point response function of the collimator that is used to define the range of directions where photons can be detected. Thus an efficient aperture correction is required. In this paper we propose a distance dependent backprojection method to overcome the time limitation of iterative aperture correction methods and the performance limitation of Fourier-Distance Relation based method. The proposed method achieves aperture correction and fast image reconstruction by replacing the distance independent backprojection of the direct image reconstruction with the distance dependent one. We conducted several simulations to compare the performance of the proposed method with that of the conventional Fourier-Distance Relation based method. The simulation result shows that the proposed method outperforms the Fourier-Distance Relation based method in spatial resolution and robustness against noise.

  • PDF

Effect of Gamma Rays Emitted by the 99mTc on the CT Image (99mTc에서 방출되는 감마선이 CT 영상에 미치는 영향)

  • Park, Jae-Yoon;Lee, Yong-Ki
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.169-174
    • /
    • 2019
  • This study examines the changes that $^{99m}Tc$ causes to CT(Computed Tomography) images quantitatively when CT scans were continuously performed using $^{99m}Tc$. With the use of the CT, $^{99m}Tc$ 740MBq was injected into the Resolution Phantom and Water Phantom, and the tube voltage was changed with 80 kVp and 120 kVp, scanning before and after the injection. The result indicate, by comparing the Signal Intensity according to the presence or absence of the $^{99m}Tc$ injection with the tube voltage of 120 kVp and 80 kVp, a decrease of 0.173 and 0.241 was observed respectively and the spatial resolution increase of 0.090 and 0.109 was observed respectively. The order of the test should be considered because the gamma rays of the radiopharmaceutical used in the nuclear medicine test do not affect the CT while the effective half-life of the radiopharmaceuticals should be considered for the CT scan to reduce the influence of the gamma rays emitted after the nuclear medicine test, with the possibility to reduce the difference of the results.

Performance measurements of Positron Emission Tomographs using NEMA NU 2-2007 (NU 2-2007을 이용한 PET/CT 성능평가)

  • An, Hye-Sun;Park, Hoon-Heu;Jin, Gye-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.3
    • /
    • pp.13-21
    • /
    • 2009
  • PET/CT is a machine for imaging in vivo functions or metabolic activities after the administration of radiopharmaceuticals labeled with radioisotope emitting positrons in the body. Recently the number of PET/CT installed in Korean medical institutions is increasing rapidly. In response, the number of PET/CT tests to be used in the diagnosis and treatment of tumors is also increasing every year, and this is increasing the necessity for developing the methods of PET/CT performance evaluation and quality control. Among the test items for the performance evaluation and quality control of PET/CT suggested in NU 2-2007, this study examined spatial resolution test, sensitivity test, image quality, attenuation accuracy & scatter correction test, scatter fraction, count losses and randoms test and accuracy( correction for count losses and randoms).

  • PDF

Monte Carlo simulation of the electronic portal imaging device using GATE

  • Chung, Yong-Hyun;Baek, Cheol-Ha;Lee, Seung-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.1 no.3
    • /
    • pp.11-16
    • /
    • 2007
  • In this study, the potential of a newly developed simulation toolkit, GATE for the simulation of electronic portal imaging devices (EPID) in radiation therapy was evaluated by characterizing the performance of the metal plate/phosphor screen detector for EPID. We compared the performances of the GATE simulator against MCNP4B code and experimental data obtained with the EPID system in order to validate its use for radiation therapy.

  • PDF

Design of Gamma Camera with Diverging Collimator for Spatial Resolution Improvement (공간분해능 향상을 위한 확산형 콜리메이터 기반의 감마카메라 설계)

  • Lee, Seung-Jae;Jang, Yeongill;Baek, Cheol-Ha
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.661-666
    • /
    • 2019
  • Diverging collimators is used to obtain reduced images of an object, or to detect a wide filed-of-view (FOV) using a small gamma camera. In the gamma camera using the diverging collimators, the block scintillator, and the pixel scintillator array, gamma rays are obliquely incident on the scintillator surface when the source is located the periphery of the FOV. Therefore, the spatial resolution is reduced because it is obliquely detected in depth direction. In this study, we designed a novel system to improve the spatial resolution in the periphery of the FOV. Using a tapered crystal array to configure the scintillation pixels to coincide with the angle of the collimator's hole allows imaging to one scintillation pixel location, even if events occur to different depths. That is, even if is detected at various points in the diagonal direction, the gamma rays interact with one crystal pixel, so resolution does not degrade. The resolution of the block scintillator and the tapered crystal array was compared and evaluated through Geant4 Application for Tomographic Emission (GATE) simulation. The spatial resolution of the obtained image was 4.05 mm in the block scintillator and 2.97 mm in the tapered crystal array. There was a 26.67% spatial resolution improvement in the tapered crystal array compared to the block scintillation.

The Evaluation of Image Quality and Radiation Dose in Multi-Detector CT (MDCT에서 화질과 방사선량에 관한 연구)

  • Han, Dong-Kyoon;Yang, Han-Joon;Kim, Moon-Chan;Ko, Shin-Gwan
    • Journal of radiological science and technology
    • /
    • v.30 no.2
    • /
    • pp.129-138
    • /
    • 2007
  • The Purpose of this study is to suggest the basic data for making good quality image and maintaining equipment homeostasis by accepting image quality evaluation and radiation dose evaluation in Multi-detector CT. In this study we surveyed 14 CT equipments in Seoul. The results obtained were as follows ; CT number was $0.56{\pm}0.70\;HU$. Noise was $0.39{\pm}0.09\;HU$. Uniformity was $1.08{\pm}0.52\;HU$. High contrast resolution was $0.48{\pm}0.05\;mm$ and low contrast resolution was $3.65{\pm}1.16\;mm$. For CTDI, the central part and the peripheral part of head phantom were $43.2{\pm}15.4\;mGy$ and $45.6{\pm}17.5\;mGy$, respectively. For body phantom, the central part and the peripheral part of head phantom were $13.5{\pm}4.5$ and $29.2{\pm}10.2\;mGy$, respectively. CTDIw was $44.8{\pm}16.8\;mGy$ and CTDIw/100 mAs was $18.8{\pm}5.3\;mGy$ using head phantom. CTDIW was $24.0{\pm}8.3\;mGy$ and CTDIw/100 mAs was $10.1{\pm}2.5\;mGy$ using body phantom. Therefore, CT number, noise, high contrast resolution, low contrast resolution, CTDI, CTDIw and CTDIw/100 mAs of MDCT were showed excellently in all equipments.

  • PDF

MIRIS 지구관측 적외선카메라 인증모델 성능 시험 및 Field Test

  • Mun, Bong-Gon;Park, Yeong-Sik;Lee, Chang-Hui;Park, Seong-Jun;Cha, Sang-Mok;Lee, Dae-Hui;Jeong, Ung-Seop;Nam, Uk-Won;Park, Jang-Hyeon;Yuk, In-Su;Ga, Neung-Hyeon;Lee, Mi-Hyeon;Lee, Deok-Haeng;Yang, Sun-Cheol;Kim, Yeong-Ju;Lee, Gi-Hun;Jeong, Han;Lee, Seung-U;Han, Won-Yong
    • Bulletin of the Korean Space Science Society
    • /
    • 2009.10a
    • /
    • pp.45.1-45.1
    • /
    • 2009
  • 과학기술위성 3호의 주탑재체인 MIRIS (Multi-purpose InfraRed Imaging System)는 우주관측카메라 (Space Observation Camera, SOC)와 지구관측카메라 (Earth Observation Camera, EOC)가 독립적인 시스템으로 구성되어 있다. 지구관측카메라는 유효 구경 100 mm, F/5의 광학계로 3-5 마이크론 파장영역을 관측하며, 국내에서 개발된 적외선 검출기의 우주 인증 시험과 유사시 한반도 적외선 감시를 주요 목적으로 하고 있다. 고도 700km에서 지상을 볼 때 약 42m/pixel의 공간분해능을 나타낼 것으로 기대하고 있다. 지구관측카메라의 인증 모델(Qualification Model)은 냉동기를 제외한 모든 부품이 국내기술로 제작되었으며, 미러 본딩 및 릴레이 렌즈 조립 기술, 적외선 영상 검교정 기술 등 다양한 경험과 도전을 제공했다. 이 발표에서는 지구관측카메라 인증모델을 이용하여 수행한 주요 시험 과정을 소개한다. 국내 회사 (주)i3 system에서 제작된 적외선 검출기는 $320\times256$ HgCdTe array (평균 양자효율 80% 이상) 이며 77K에서 정상적으로 운영된다. Micro Stirling Cooler에 의해 듀어는 전원을 켠 후 5분 이내에 검출기 운영온도인 77K까지 내려간다. 적외선 광학계의 정렬, 시스템 MTF 측정, 흑체 측정 및 검교정 작업을 수행한 후 야외에서 다양한 경우에 대해 Field Test를 진행했다. 이 발표에서는 Field Test 과정과 이를 통해 얻은 결과를 발표하고, FM (Flight Model) 제작에 있어 수정해야 할 사항들을 제안해 본다.

  • PDF