Browse > Article
http://dx.doi.org/10.7742/jksr.2019.13.2.169

Effect of Gamma Rays Emitted by the 99mTc on the CT Image  

Park, Jae-Yoon (Department of Radiology, Incheon Christian Hospital)
Lee, Yong-Ki (Department of Radiological Technology, Dongnam Health University)
Publication Information
Journal of the Korean Society of Radiology / v.13, no.2, 2019 , pp. 169-174 More about this Journal
Abstract
This study examines the changes that $^{99m}Tc$ causes to CT(Computed Tomography) images quantitatively when CT scans were continuously performed using $^{99m}Tc$. With the use of the CT, $^{99m}Tc$ 740MBq was injected into the Resolution Phantom and Water Phantom, and the tube voltage was changed with 80 kVp and 120 kVp, scanning before and after the injection. The result indicate, by comparing the Signal Intensity according to the presence or absence of the $^{99m}Tc$ injection with the tube voltage of 120 kVp and 80 kVp, a decrease of 0.173 and 0.241 was observed respectively and the spatial resolution increase of 0.090 and 0.109 was observed respectively. The order of the test should be considered because the gamma rays of the radiopharmaceutical used in the nuclear medicine test do not affect the CT while the effective half-life of the radiopharmaceuticals should be considered for the CT scan to reduce the influence of the gamma rays emitted after the nuclear medicine test, with the possibility to reduce the difference of the results.
Keywords
Computed Tomography; Nuclear medicine; $^{99m}Tc$;
Citations & Related Records
Times Cited By KSCI : 6  (Citation Analysis)
연도 인용수 순위
1 G. J. Kim, S. H. Bae, K. J. Kim, H. K. Oh, "Effect of Gamma Energy of Positron Emission Radionuclide on X-Ray CT Image," Journal of the Korea Academia-Industrial Cooperation Society, Vol. 12, No. 10, pp. 4418-4424, 2011.   DOI
2 J. W. Kwon, J. H. Jeong, K. W. Jang, J. K. Lee, "Medical exposure of Korean by diagnostic radiology and nuclear medicine examinations," Journal of Radiation Protection and Research, Vol. 30, No. 4, pp. 185-196, 2005.
3 Y. G. Kang, "TEXTBOOK of Nuclear Medicine," 1st edition. Chung-ku Publisher, pp. 13-16, 2013.
4 M. C. Lee, "Statistical data on radioisotope use, Korean Nuclear Medicine Society," pp. 1-119, 2011.
5 J. H. Jung, Y. Choi, K. J. Hong, B. J. Min, W. Hu, J. H. Kang, "Recent Advances in Nuclear Medicine Imaging Instrumentation," Nuclear Medicine and Molecular Imaging, Vol. 42, No. 2, pp. 98-111, 2008.
6 S. Y. Cha, Y. K. Cho, Y. K. Lee, J. N. Song, N. K. Choi, "The Effectiveness of CT and MRI Contrast Agent for SUV in 18F-FDG PET/CT Scanning," Journal of the Korean Society of Radiology, Vol. 10, No. 4, pp. 255-261, 2016.   DOI
7 J. I. Kim, I. S. Kim, H. J. Lee, J. E. Kim, "Effect of MRI Media Contrast on PET/MRI," Journal of Nuclear Medicine Technology, Vol. 18, No. 1. pp. 19-25, 2014.
8 K. J. Jang, D. C. Kweon, "Case study of quality assurance for MDCT image quality evaluation using AAPM CT performance phantom," The Journal of the Korea Contents Association, Vol. 7, No. 7, pp. 114-123, 2007.   DOI
9 S. W. Yoon, S. B. Kim, "The Effects of Waiting Time on Service Quality Evaluation and Goodwill at Medical Service Encounter," Marketing Journal, Vol, 5. No. 1, pp. 1-22, 2003.
10 J. W. Kwon, J. H. Jeong, K. W. Jang, J. K. Lee, "Medical exposure of Korean by diagnostic radiology and nuclear medicine examinations," Journal of Radiation Protection and Research, Vol. 30, No. 4, pp. 185-196, 2005.
11 H. J. Verberne, W. Acampa, C. Anagnostopoulos, J. Ballinger, F. Bengel, P. De Bondt, M. Hacker, "EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT: 2015 revision," European journal of nuclear medicine and molecular imaging, Vol. 42, No. 12, pp. 1929-1940, 2015.   DOI
12 S. J. Pyo, Y. H. Cho, J. H. Choi, "Effects of Use of the Iodine Contrast Medium on Gamma Camera Imaging," Journal of Radiological Science and Technology, Vol. 39, No. 4, pp. 557-564, 2016.   DOI
13 S. J. Kim, J. I. Kim, T. Y. Kim, S. M. Kim, J. R. Woo, J. S. Lee, H. Y. Lee, "Accuracy evaluation of CT-based attenuation correction in SPECT with different energy of radioisotopes," Journal of Nuclear Medicine, Vol. 53, No. 1, pp. 2533-2533, 2012.
14 E. J. Choi, Y. D. Son, Y. Noh, H. Lee, Y. B. Kim, K. H. Park, "Glucose Hypometabolism in Hippocampal Subdivisions in Alzheimer's Disease: A Pilot Study Using High-Resolution 18F-FDG PET and 7.0-T MRI," Journal of Clinical Neurology, Vol. 14, No. 2, pp. 158-164, 2018.   DOI
15 B. Mueller, M. K. O'connor, "Effects of radioisotopes on the accuracy of dual-energy X-ray absorptiometry for bone densitometry," Journal of Clinical Densitometry, Vol. 5, No. 3, pp. 283-287, 2002.   DOI
16 E. H. Lee, Y. S. Lee, G. J. Kim, J. G. Choi, "The Effects of Diagnostic Radiology Image on Radiopharmaceutical Testing," Korean Journal of Digital Imaging in Medicine, Vol. 12, No. 2, pp. 113-117, 2010.