• Title/Summary/Keyword: 열 차단

Search Result 281, Processing Time 0.028 seconds

Wave Screening Performance of the Submerged Breakwater With Various Crown Widths (폭 변화에 따른 잠제의 파랑 차단 성능)

  • Cho Won Chul
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.16 no.4
    • /
    • pp.206-212
    • /
    • 2004
  • The numerical analysis on the wave screening performance of the submerged breakwater with various crown widths is presented. The fluid motion is considered as linearized two dimensional potential flow and the finite element method is used to analyze the wave screening performance of the submerged breakwater. It is found that single-submerged breakwater with large crown width shows the most effective wave screening performance and single-submerged breakwater with small crown width also shows fairly good wave screening performance but its effectiveness is less than that of single-submerged breakwater with large crown width. However, double- or triple-submerged breakwater with small crown width shows more effective wave screening performance than that of single- or double-submerged breakwater with large crown width. It is expected that the submerged breakwater with small crown width is economical because it reduces the size of structure.

A Study on the Displacements-Thermal Stress Analysis of Smoke/Heat Interception Screen in Eire Door (방화문용 연기/열 차단막의 변위-열응력 해석에 관한 연구)

  • 이동명
    • Fire Science and Engineering
    • /
    • v.18 no.2
    • /
    • pp.73-78
    • /
    • 2004
  • This study investigated about smoke/heat interception screen that can protect underneath of fire door and floor when occur fire, and keep out leakage or diffusion of smoke/heat. In this study, to considered differential pressure form smoke control area and mechanical force by fluid buoyancy of smoke when occur fire and stream of heat, are analyzed to used $ANSYS^{\circledR}$ of finite element analysis code. It presented direction of optimal design of smoke/heat interception screens that can minimize loading condition from study results, and helped that construct basic engineering data of smoke/heat interception systems as that utilize its shape design of smoke/heat interception screens.

A Study on Deep learning algorithm comparison for Block AI virus using thermal video and IoT (열영상과 IoT를 이용한 AI 바이러스 차단을 위한 딥러닝 알고리즘 비교에 대한 연구)

  • No, Seunghyun;seo, hojun;kim, hyein;Kim, Jeong-Min
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2021.11a
    • /
    • pp.1097-1100
    • /
    • 2021
  • 열영상과 IoT를 이용한 AI 바이러스 차단 시스템 개발에 필요한 열화상 체온 측정기의 열 측정 정확도 향상과 얼굴 인식 시간 단축을 위해 열화상에 사용되는 딥러닝 알고리즘을 비교하며 효율적인 알고리즘 발굴 및 열영상을 이용한 바이러스 차단 시스템에 적합한 열영상 알고리즘 보완 방법을 찾는 연구이다.

여름철 열 차단 자신 있다

  • 대한양계협회
    • KOREAN POULTRY JOURNAL
    • /
    • v.37 no.8 s.430
    • /
    • pp.111-113
    • /
    • 2005
  • 장마철이 끝나고 폭염이 시작되는 8월이면 어김없이 찾아오는 닭 생산성 저하, 농가에서 태양열을 효과적으로 차단한다면 생산성 유지에 도움될 것이다. 특히 단열 시설이 부족한 계사에서는 단열에 대한 아쉬움이 더욱 커지기 마련이다. 그래서 이번 호에는 무리한 투자비용을 아끼면서 단열 효과를 누릴 수 있는 초단열용 페인트 첨가제를 보급하는 SEN21를 찾았다.

  • PDF

Development of the Sunshade hat with a large brim (Part II) - Human trial test at outdoors - (양산형 일광차단모의 개발(제2보) -실외 인체착용시 복사열 및 자외선의 차단효과-)

  • 최정화;김경수
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.3_4
    • /
    • pp.414-421
    • /
    • 2004
  • To reduce farmer's stress from solar radiation and ultraviolet radiation(UV), the sunshade hat with a large brim and special structure for ventilation was developed and tested with manikin heads outdoors at previous study(Kim and Choi, 2002). To evaluate the protection efficiency of the sunshade hat, human trial test was performed at outdoors. The results were as follows; Skin temperatures(7 sites), heart rate, temperature inside the hats, temperature and relative humidity inside clothing on the back in wearing developed sunshade hat were significantly lower than those in wearing the controlled hat. In subjective sensation, subjects answered to feel significantly hotter, more humid and more uncomfortable in wearing the controlled hat. But relative humidity inside the hats was significantly higher in wearing developed hat. In rectal temperature, there were no significant differences between two hats.

차단기의 해석기술

  • 신영준;박경엽;송기동;송원표;민석원
    • 전기의세계
    • /
    • v.45 no.2
    • /
    • pp.17-24
    • /
    • 1996
  • 차단기의 개발과정은 크게 모의시험, 설계 및 제작, 성능시험 3가지로 나누어 볼 수 있다.이 중에서 모의 시험은 일반적으로 해석기술에 의해 주로 이루어지며, 차단기에 적용되는 해석기술은 1) 차단부 전계해석 2) 차단부 냉가스 유동해석 3) 차단부 열가스 유동해석(차단성능해석) 4) 차단기 동작특성해석 5) 차단기 응력해석 및 구조해석으로 대별할 수 있다. 상기의 해석기술은 적용하는 해석방법에 따라 다소 차이가 있지만, 1992년부터 당 연구팀이 개발중인 800kV 40kA 4000A 차단부를 개발하는 과정에 적용한 해석수법을 중심으로 살펴보기로 한다.

  • PDF

A Numerical Study on Thermal Analysis of Fuel Shut-off Valve (연료차단밸브의 열해석에 관한 수치적 연구)

  • Baek, Nak-Gon;Lee, Jae-Yun
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.5
    • /
    • pp.108-114
    • /
    • 2012
  • Thermal and fluid flow characteristics in a fuel shut-off valve under operating conditions are studied numerically. The disk size of the valve has 15 mm diameters and maximum mass flow rate is 600 kg/h. The Analysis was performed in the commercial code, STAR-CCM+. This paper shows that results from the numerical analysis has a good agreement compared to experimental results.

A Numerical Study on Thermal Analysis of Fuel Shut-off Valve (연료차단밸브의 열해석에 관한 수치적 연구)

  • Baek, Nak-Gon;Lee, Jae-Yun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.559-564
    • /
    • 2011
  • Thermal and fluid flow characteristics in a fuel shut-off valve under operating conditions are studied numerically. The disk size of the valve has 15mm diameters and maximum mass flow rate is 600 kg/h. The Analysis was performed in the commercial code, STAR-CCM+. This paper shows that results from the numerical analysis has a good agreement compared to experimental results.

  • PDF

위성광학탑재체 우주환경시험용 진공챔버 개발

  • Lee, Sang-Hun;Jo, Hyeok-Jin;Seo, Hui-Jun;Mun, Gwi-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.147-147
    • /
    • 2013
  • 인공위성이 임무를 수행하는 우주공간은 고진공 환경과 태양 복사열에 의한 고온 환경 및 극저온이 반복되는 가혹한 환경으로, 위성체는 이러한 가혹한 우주환경의 영향으로 인해 주요부품의 기능장애가 초래되기도 하며 이는 결국 임무의 실패로 이어지도 한다. 따라서 10E-06 torr 이하의 고진공과 $-180^{\circ}C$의 극저온 환경으로 일컬어지는 우주환경을 지상에서 모사하여 위성체의 안정성 및 신뢰성을 시험하기 위해서 열진공 시험장비를 이용한 열진공시험을 수행한다. 한국항공우주연구원에서는 인공위성의 탑재체인 광학카메라의 국산화 개발을 위하여 우주공간의 고진공과 극저온 상태를 모사할 수 있는 ${\varphi}4m{\times}L10m$ 규모의 광학탑재체 전용 열진 공챔버를 국산화 개발하여 사용하고 있다. 탑재체 진공시험은 진공환경의 조성과 함께 외부진동을 완벽하게 차단하는 것이 매우 중요하다. 본 논문에서는 한국항공우주연구원에서 보유한 광학탐재체용 진공챔버에서 진공 유지와 진동 차단을 동시에 수행하고 있는 방법에 대해 살펴보고자 한다.

  • PDF

A Study on the Radiation Heat Transfer Effect near a Refrigerator Gasket (냉장고 가스켓 주위의 복사열전달 효과에 관한 연구)

  • Ha, Ji-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.1605-1610
    • /
    • 2015
  • The present study has been accomplished to elucidate the effect of radiation heat transfer in the heat transfer analysis of refrigerator gasket, which has near 30% of refrigerator heat loss. The numerical heat transfer analysis has been conducted with the simplified modeling of refrigerator gasket. From the present CFD analysis, heat loss at the gasket is $25.6W/m^2$ for the case without radiation effect and that for the case with radiation effect is $55.0W/m^2$, which is 2.2 times greater heat loss. The radiation protection layers were installed in the gasket from 0 to 7 and the case with 7 layers has 33% reduction effect of heat loss compared with the case without any radiation protection layer. Additionally, it is better effect of radiation heat loss reduction that the radiation protection layers would be placed to the outer or inner side of gasket rather than placing to the center of gasket.