• 제목/요약/키워드: 열 유속

검색결과 752건 처리시간 0.031초

구리나노입자가 코팅된 열교환기의 안전성 향상을 위한 임계 열유속 측정실험 (Critical heat flux measurement experiment to improve safety of copper nano-particle coated heat exchanger)

  • 모용현;김남진;전용한;이덕수
    • 대한안전경영과학회지
    • /
    • 제19권4호
    • /
    • pp.317-322
    • /
    • 2017
  • When the heat flux on the heating surface following changing heat condition in the boiling heat transfer system exceeds critical heat flux, the critical heat flux phenomenon is going over to immediately the film boiling area and then it is occurred the physical destruction phenomenon of various heat transfer systems. In order to maximize the safe operation and performance of the heat transfer system, it is essential to improve the CHF(Critical Heat Flux) of the system. Therefore, we have analysis the effect of improving CHF and characteristics of heat transfer following the nanoparticle coating thickness. As the results, copper nanocoating time are increased to CHF, and in case of nano-coatings are increased spray-deposited coating times more than in the fure water; copper nanopowder is increased up to 6.40%. The boiling heat transfer coefficients of the pure water are increased up to 5.79% respectively. Also, the contact angle is decreased and surface roughness is increased when nano-coating time is increasingly going up.

집광 열유속 측정과 모델링의 비교를 통한 집광 오차 평가 (Concentration Error Assessment by Comparison of Solar Flux Measurement and Modeling)

  • 채관교;윤환기;이현진;이성욱;김시석
    • 한국태양에너지학회 논문집
    • /
    • 제33권3호
    • /
    • pp.82-90
    • /
    • 2013
  • Concentration errors critically affect the performance of solar concentrator, so their evaluation is important to the concentrated solar power technology. However, the evaluation is very challenging because error sources are various and not easy to measure individually. Therefore, the integrated effect of concentration errors is often more interesting and useful for large-scale applications. In the present work, we analytically investigate and classify various concentration error sources and then explain that the effect of various concentration errors can be represented in terms of a root mean square value of reflector surface slope error. We present an indirect approach to assessing the reflector surface slope error by comparing solar flux measurement data with modeling calculations. We apply the approach for solar furnaces with different thermal capacity and investigate its advantages and disadvantages.

마이크로다공성 발열체 표면에서의 액체분무 냉각성능 특성 (Characteristics on Spray Cooling Performance on the Micro-Porous Coated Surfaces)

  • 김윤호;최치환;이규정
    • 설비공학논문집
    • /
    • 제18권4호
    • /
    • pp.304-311
    • /
    • 2006
  • Experiments on evaporative spray cooling on the square plate heaters with plain or micro-porous coated surfaces were performed in this study. Micro-porous coated surfaces were made by using DOM [Diamond particle, Omegabond 101, Methyl-Ethyl-Keton] method. In case of purely air-jet cooling, the micro-porous coating doesn't affect the cooling capacity. In spray cooling three different flow patterns (complete wetting, evaporative wetting, dryout) are observed on both plain and micro-porous coated surfaces. The effects of various operating conditions, such as water flow rate, particle size, and coating thickness were investigated on the micro-porous coated surfaces. It is found that the level of surface wetting is an important factor to determine the performance of spray cooling. It depends on the balance between absorbed liquid amount by capillary force over porosity and the evaporative amount. The micro-porous coated surface has largest cooling capacity, especially in the evaporative wetting zone. It is found that the effects of liquid flow rate and coating thickness are significant in evaporative wetting zone, but are not in complete wetting and dryout zones.

단일 전단 동축 분사기를 가지는 GH2/GO2 로켓 연소기의 고해상도 수치해석 (Numerical Study of High Resolution Schemes for GH2/GO2 Rocket Combustor using Single Shear Coaxial Injector)

  • 정승민;엄재령;최정열
    • 한국추진공학회지
    • /
    • 제22권6호
    • /
    • pp.72-83
    • /
    • 2018
  • 본 연구에서는 단일 전단 동축 분사기를 이용한 수소 로켓 연소기의 전산유체 해석을 수행하였다. 2차원 축대칭 형상에서 난류연소 해석을 위해 hybrid RANS/LES 난류모델을 적용하였다. 적합한 해석기법을 찾기 위해 3가지 화학 반응기구, 3가지 고해상도 기법 및 3단계 격자해상도 조합을 비교하였다. 벽면 열유속을 실험결과와 비교하여 해석 성능을 살펴보았으며, 유동장 결과 분석으로 동축 분사기를 가지는 로켓 연소기의 난류연소특성을 살펴볼 수 있었다.

모의 생체조직의 표면온도 조건에 따른 근육이완 특성에 관한 연구 (A Study on the Characteristics of Muscle Relaxation according to the Temperature Condition at the Surface of Imitational Biological Tissue)

  • 고동국;이찬우;김민수
    • 한국기계기술학회지
    • /
    • 제20권6호
    • /
    • pp.770-775
    • /
    • 2018
  • In this study, the characteristics of muscle relaxation were analyzed by the experimental and numerical method. A skin tissue was produced by imitational biological tissue using the agar powder, saline solution and sugar. The tissue was exposed to three types of wavelength-blue visible radiation(410 nm), red visible radiation(635 nm), and infrared ray(830 nm). The temperature results along the depth of tissue were measured according to the variation of light wavelength and irradiation time. The temperature change of the tissue shown up similar pattern regardless of the light wavelength kinds. The wavelength of infrared ray penetrated strongly into tissue between 3.2 mm and 11.4 mm. Also, the temperature change with the irradiation time was small, and the temperature value of the infrared ray was the largest. As a result, the muscle relaxation will occur mainly at the infrared wavelength.

용탕조건에 따른 상용 차량용 어댑터 하우징의 열적특성에 관한 연구 (A Study on Thermal Characteristics of Adaptor Housing for Commercial Vehicles according to Molten Metal Condition)

  • 고동국;명순식;강병용;김민수
    • 한국기계기술학회지
    • /
    • 제20권6호
    • /
    • pp.745-750
    • /
    • 2018
  • In this study, the thermal behavior of adaptor housing was analyzed by the numerical method. The boundary conditions used to die casting process were the temperature of molten metal and injection time. As the temperature of the molten metal increased, the tensile strength of the product decreased by the blow hole generated in the molten metal, and the decreasing tendency was gradually decreased. As the injection time of the molten metal increased, the heat flux rose, but the degree of the increase was very small. So, the injection time of the molten metal had little effect on the thermal behavior and diffusion of the adapter housing. As a result, the heat of the molten metal was transferred into the housing and the thermal behavior spread widely.

CFD 시뮬레이션 기반 초임계 LNG용 사인함수 PCHE 설계 (Design of sinusoidal shape channel PCHEs for supercritical LNG based on CFD simulation)

  • 판진싱;염은섭
    • 한국가시화정보학회지
    • /
    • 제19권3호
    • /
    • pp.69-76
    • /
    • 2021
  • Printed circuit heat exchanger (PCHE) is a compact heat exchanger with good heat transfer performance, high structure integrity, and reliability over a wide range of temperatures and pressures. Instead of the traditional zigzag and straight shape channel, the sinusoidal shape channel was adopted in this study to investigate the relation of thermal-hydraulic performance and waviness factors (period and amplitude). The local flow characteristics and the heat flux distribution were compared to verify the effects of period and amplitude on heat transfer performance. As the period of channel becomes shorter, the rapid change of the flow direction can produce high flow separation around the corner leading to the disturbance of the boundary layer opposite wall. The nonuniform distribution of flow velocity appeared around the corner positions can promote fluid mixing and lead to higher thermal performance. An evaluation index was used to compare the comprehensive performance of PCHE considering the Nusselt number and Fanning factor. Based on the simulation results, the optimal design parameters of PCHE channel shape were found that the channel with an equivalent bending angle of 15° offers the highest heat flux capacity.

균일한 열유속에서의 수직동관내의 강제대류 열전달에 관한 연구 (A study on the forced convection heat transfer in the vertical copper tube at uniform wall heat flux)

  • 백고길;차지영;서정윤
    • 대한설비공학회지:설비저널
    • /
    • 제8권4호
    • /
    • pp.213-220
    • /
    • 1979
  • A number of methods has been developed for calculation of heat transfer in the vertical round tube under conditions of forced convection with uniform heat flux at wall. I would like to express hereby one of applications of this study in the design of heat exchanger instruments for water flow at $15.8^{\circ}C(p_r=8)$ used frequently in our daily life. Also all the results are investigated for forced convective heat transfer in the case of heated water-flow at uniform wall heat flux in the vortical round copper tube, where the ratio of length to diameter will be 44. They are well in agreement with Gratz and Kraussold equation respectively in laminar and transition flow range. In turbulent flow in the range from Re=10,000 to 65,000, the experimental formula Is show as follows ; Nu=0.023 $R_e^{0.814}\;P_r^{0.4}$. And this is agreed with Dittus - Boelter equation when Reynolds number exponent increases from 0.80 to 0.814.

  • PDF

하천 친수공간 복합모니터링을 통한 친수활동 종합지수 개발 연구 (A study on the development of a comprehensive waterfront activity index through complex monitoring in waterfront)

  • 정우석;권시윤;이수정;권재현
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2022년도 학술발표회
    • /
    • pp.490-490
    • /
    • 2022
  • 국내 대하천 및 중·소규모 하천의 홍수터 공간을 활용하여 체육시설 및 공원 등과 같은 친수 시설물을 조성하여 친수공간으로 활용하고 있으며, 시민들의 친수활동 빈도는 증가추세에 있다. 특히 하천 내에서 수상 레크레이션 활동 등과 같은 다양한 친수활동이 증가하고 있으며, 하천친수에 관한 정보 수요가 급증하고 있으나 체계적인 공급은 미흡한 수준이다. 따라서 본 연구에서는 친수공간 조성 및 유지관리에 대한 측면과 친수공간에서의 쾌적한 친수활동을 위한 정보제공 목적으로 하천 친수공간에서의 복합모니터링을 이용한 친수활동 종합지수를 산정 방법을 개발하고자 하였다. 센서 기반의 시계열 데이터 구축을 위해 하천 수질, 수리인자의 복합모니터링을 진행하였다. 수리인자(수위, 유속, 수면폭 등)와 수질인자(탁도, Chl-a, pH 등), 기상학적 인자(자외선 지수, 미세먼지 등) 등급에 따른 허용기준을 설정하여 각 등급 별로 수리인자의 값을 0~1 사이 값인 소속도로 변환하여 소속도의 합성 및 친수활동 등급을 결정하였다. 최종적으로 수리, 수질, 기상 인자별 소속도 함수 산정을 통한 퍼지합성 이론 기반의 친수활동 종합지수를 산정하였다. 그리고 친수활동 종합지수를 예보하기 위한 모델 적용을 위한 방향성을 정립하였다.

  • PDF

비가열냉동 당근주스의 HACCP 시스템 적용을 위한 미생물학적 위해 분석 (Microbiological Hazard Analysis for HACCP System Application to Non Heat-Frozen Carrot Juice)

  • 이웅수;권상철
    • 한국식품위생안전성학회지
    • /
    • 제29권2호
    • /
    • pp.79-84
    • /
    • 2014
  • 본 연구는 비가열 섭취 냉동 당근주스의 HACCP (Hazard Analysis Critical Control Point)시스템 구축을 위하여 생물학적 위해요소분석을 위한 목적으로 2013년 6월 21일~2014년 3월 30일까지 약 270일간 제주도 제주시 구좌읍 소재에 있는 구좌농협에서 수행하였다. 일반적인 과채주스 제조업체의 제조공정을 참고로 하여 공정도를 작성하였으며, 원료 농산물(당근), 용수와 포장재료 입고, 보관, 세척, 분쇄, 착즙, 냉각, 내포장, 금속검출, 외포장, 보관 및 출하공정에 대하여 Fig. 1과 같이 작성하였다. 원료 당근의 세척 전, 세척 후의 Coliform group, Staphylococcus aureus, Salmonella spp., Bacillus cereus, Listeria Monocytogenes, 장출혈성대장균수를 측정한 결과 Bacillus cereus 는 세척 전 $4.70{\times}10^4CFU/g$이었으나, 세척 후 $1.02{\times}10^2CFU/g$ 검출되었으며, 나머지 병원성균은 검출되지 않았다. 자외선살균공정에서 당근주스의 유속를 변화시키면서 미생물의 변화를 시험한 결과 유속 4 L/min을 한계기준으로 결정하였다. 작업장별 공중낙하균(일반세균수, 대장균, 진균수) 시험결과 세척실의 미생물수는 20 CFU/Plate가 검출되었다. 작업자 손 세척 전후 시험결과 세척 전 일반세균수가 $6{\times}10^4CFU/cm^2$로 높게 나타났으나 손 세척 후에는 검출되지 않아 손 세척 및 소독에 대한 중요성을 교육하고 훈련해야 할 것이다. 제조설비 및 기구의 표면오염도를 검사한 결과 모든 시료에서 대장균군은 검출되지 않았고, 일반세균은 포장기 노즐에서 가장 많은 $8.5{\times}10^4CFU/cm^2$ 검출되었다. 위해분석 결과 병원성미생물을 예방, 감소 또는 제거할 수 있는 자외선살균 공정이 CCP-B (Biological)로 관리되어야 하고, 한계기준은 유속 4 L/min로 결정하였다. 따라서 Kwon의 유산균을 함유한 녹즙의 HACCP에 관한 연구에서와 같이 자외선살균 공정의 한계기준 및 이탈시 조치방법, 검증방법, 교육 훈련과 기록관리 등 철저한 HACCP 관리계획이 필요할 것으로 생각된다.