Thermoexcel-E 촉진 표면에서 임계 열유속까지의 분무 냉각 열전달 특성 (Heat Transfer Characteristics of Spray Cooling Up to Critical Heat Flux on Thermoexcel-E Enhanced Surface)

  • 이요한;홍광욱;이준수;정동수
    • 설비공학논문집
    • /
    • 제28권9호
    • /
    • pp.373-380
    • /
    • 2016
  • Spray cooling is a technology of increasing interest for electronic cooling and other high heat flux applications. In this study, heat transfer coefficients (HTCs) and critical heat fluxes (CHFs) are measured on a smooth square flat copper heater of $9.53{\times}9.53mm$ at $36^{\circ}C$ in a pool, a smooth flat surface and Thermoexcel-E surfaces are used to see the change in HTCs and CHFs according to the surface characteristics and FC-72 is used as the working fluid. FC-72 fluid has a significant influence on heat transfer characteristics of the spray over the cooling surface. HTCs are taken from $10kW/m^2$ to critical heat flux for all surfaces. Test results with Thermoexcel-E showed that CHFs of all enhanced surface is greatly improved. It can be said that surface form affects heat transfer coefficient and critical heat flux.

나노유체의 임계열유속 및 비등특성에 미치는 나노입자 크기의 영향 (Effect of particle sizes on CHF enhancement and boiling characteristics of nano-fluids)

  • 조병남;강준원;유재석;김현정
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2006년도 추계학술대회 논문집
    • /
    • pp.125-130
    • /
    • 2006
  • The characteristics of boiling heat transfer and critical heat flux (CHF) behavior of nano-fluids were studied by using various sized silver and alumina nanoparticles. The diameter of nanoparticles was from 2 nm to 250 nm for silver and from 20nm to 40nm for alumina. Pool boiling characteristics and CHF enhancement of nano-fluids with different sized nanoparticles were compared with those of pure water and each nano-fluids. The experiment was performed at atmospheric pressure and the temperature of the pool was maintained constantly by using a flat immersed heater. The concentration of nano-fluids was uniform in all experiments as 0.01g/liter. The results showed that the measured boiling curves were shifted to the right. It demonstrated that the occurrence of nucleate boiling regime in nano-fluids retarded, compared with that of pure water. Also, in nano-fluids, the boiling curves showed that CHF of nano-fluids is significantly enhanced and represented the effect of particle size on boiling characteristics.

  • PDF

초음속 유동장내 2차분사 분사각도 변화에 따른 열전달 특성 변화 (Heat Transfer on Secondary Injection Surface in Supersonic Flow-field with Various Injection Angle)

  • 송지운;이종주;조형희;배주찬
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년도 제31회 추계학술대회논문집
    • /
    • pp.321-325
    • /
    • 2008
  • 초음속 유동장내에 분사된 2차제트 주변에서의 열전달 현상을 고찰 하였다. 초음속 유동장내에 분사되는 2차유동의 Jet to freestream momentum ratio(운동량비)의 변화와, 2차유동 분사각도에 따른 2차 분사홀 주변의 열전달 특성을 파악하기 위하여 홀 주변의 표면온도 변화를 고속 적외선 카메라를 통하여 측정하였으며, 이를 이용하여 비정상 열유속 기법을 바탕으로 열유속을 계산하였다. 운동량비가 증가할 수록 열전달 현상이 강화 되었으며, $15^{\circ}$ 기울어진 분사보다는 수직 분사의 경우에 더 강한 열전달 현상이 발생되었다. 이를 통해 분사비와 분사 각도가 표면 열전달 분포에 중요한 요인으로 작용함을 확인할 수 있었다.

  • PDF

Low-fin 촉진 표면에서 임계 열유속까지의 분무 냉각 열전달 특성 (Heat Transfer Characteristics of Spray Cooling up to Critical Heat Flux on a Low-fin Enhanced Surface)

  • 이요한;강동규;정동수
    • 설비공학논문집
    • /
    • 제25권9호
    • /
    • pp.522-528
    • /
    • 2013
  • Spray cooling is a technology of increasing interest for electronic cooling and other high heat flux applications. In this study, heat transfer coefficients (HTCs) and critical heat fluxes (CHFs) were measured on a smooth square flat copper heater of $9.53{\times}9.53$ mm at $36^{\circ}C$ in a pool, with a smooth flat surface, and 26 fpi. Low-fin surfaces were used to see the change in HTCs and CHFs according to the surface characteristics, and FC-72 was used as the working fluid. FC-72 fluid had a significant influence on the heat transfer characteristics of the spray over the cooling surface. HTCs were taken from 10 $kW/m^2$ to critical heat flux, for all surfaces. Test results with Low-fin showed that the CHFs of all the enhanced surface were greatly improved. It can be said that the surface form affects the heat transfer coefficient and critical heat flux.

히터 길이가 수조비등 임계열유속에 미치는 수력학적 영향 (Hydrodynamic effects of heater lengths on pool boiling critical heat flux)

  • 박수청;김도연;최선호;이창훈;임영훈;이치영;이연원;유동인
    • 한국가시화정보학회지
    • /
    • 제21권1호
    • /
    • pp.67-73
    • /
    • 2023
  • In the study, pool boing critical heat flux (CHF) was experimentally investigated depending on the length of heaters. A smooth silicon oxide surfaces are used as the boiling surfaces. As the results of pool boiling experiments based on distilled water in ambient pressure condition, the CHF decreased as the length of the heater increased. By the high speed imaging, it was shown that the number of vapor columns increased as the length of the heater increased. Comparing the number of vapor columns and the CHF according to the heater length, the change in the CHF according to the heater length was analyzed based on the hydrodynamic instability.

가동조건 변화에 따른 순산소 마일드 연소 형성 연구 (Formation of Oxy-Fuel MILD Combustion under Different Operating Conditions)

  • 이필형;황상순
    • 대한기계학회논문집B
    • /
    • 제40권9호
    • /
    • pp.577-587
    • /
    • 2016
  • 순산소 마일드 연소는 공기를 사용하는 연소에 비하여 열효율 및 연소안정성이 높고 배기가스 배출량이 낮아 유망한 연소기술 중 하나로 알려져 있지만 마일드 화염의 형성에는 아직까지 많은 어려움이 있는 실정이다. 본 논문에서는 순산소 마일드 형성을 위하여 연소기 형상 및 운전조건 변화가 순산소 마일드 연소에 미치는 영향을 3차원 수치해석을 적용하여 분석하였다. 수치해석 결과 마일드 연소화염의 특징인 고온영역과 평균온도를 감소시키는 데 있어서 산화제유속 증가가 보다 효과적임을 확인하였다. 또한 외부 예열이 없는 조건에서도 최적화된 산소-연료 공급조건에서 순산소 마일드 연소화염의 형성 가능성을 확인하였고 안정적인 순산소 마일드 연소는 당량비 0.90, 연료유속 10 m/s, 산소유속 200 m/s, 노즐간 거리 33.5 mm 조건에서 보다 안정적으로 형성됨을 확인할 수 있었다.

鉛直 過粘性係數가 流速의 鉛直構造에 미치는 影響 - 鉛直 過粘性係數가 주어진 境遇 - (Effects of Vertical Eddy Viscosity on the Velocity Profile - Cases of Given Vertical Eddy viscosity -)

  • 이종찬;최병호
    • 한국해양학회지
    • /
    • 제29권2호
    • /
    • pp.119-131
    • /
    • 1994
  • 모드분리기법의 gird-box형 3차원 수치모형을 이용하여 등밀도 등수심 유한영역에 서의 연직과점성 개수에 따른 취송유와 조류의 수평 유속 연직구조를 분석하였다. 연) 직과점성 계수가 수심에 일정할 경우 선영적으로 감소또는 증가하는 경우 이차함수 및 지수함수적으로 변하는 경우에 대한 해석해와의 비교를 통하여 모형 검증 및 연직유속 구조 분석이 실시되었다. 아울러 취송유에 경우 유속의 연직구조에 대한 해수표면 근 처에 "wall layer" 영향을 수치적으로 검토하였다. 모든 수직계산에서 연직층수는 열 세개로 가변 객자가 사용되었다. 수치모형은 유속의 연직구조를 만족스럽게 재연하게 으나 연직과점성 개수가 수심에 대하여 2차함수 및 지수적으로 감소하는 경우 해저면 부근에서 유속의 연직변화가 크게 나타나면서 해석해와 수치모형 결과간에 약간에 차 이가 나타났다. 수평 유속의 연직구조는 연직과점성 계수의 절대값 및 함수형태에 따 라 달라지며 해저면과 해수표면 부근의 유속은 wall layer 내의 연직과점성 계수에 민 감하게 반응하였다. 취송유에 경우에 해수표면에서의 연직 과점성 계수가 작을수록 강 한 shear가 표층에 형성되었으며 조류에 경우 연직 과점성 계수의 분포와 상관없이 해 저 한계층 상부의 유속은 거의 일정하게 나타나고 해조표내의 유속은 연직과점성 계수 가 줄어들수록 강한 shear 보였다.shear 보였다.

  • PDF

회유수조 제작 및 시험에 관한 연구 (A Study of Circulating Water Channel)

  • 장지원;하강열;이운희
    • 한국수산과학회지
    • /
    • 제18권1호
    • /
    • pp.8-14
    • /
    • 1985
  • 어구의 모형실험을 위한 회유수조를 제작하여 시험한 결과를 요약하면 다음과 같다. 1. 동력 50 H.P.의 D.C. Motor에 의하여 생기는 최대 유속은 약 2.3m/sec로서 지시전압 200 V, 지시전류 185 A에서 나타났다. 2. 유속과 전압과의 관계는 $0{\sim}1.0m/sec$까지는 비선형적으로 비례하나 1.0m/sec 이상에서 직선적으로 비례하였다. 3. 공칭 유속의 범위는 0.4m/sec에서 1.8m/sec까지이다. 그 이상으로 부터 최대 2.3m/sec까지는 수십분 이상 사용하며 모터의 과열현상이 나타났다 4. 수유 횡단면을 따르는 수직 유속분포는 수로중앙을 중심으로 좌우 약 70 cm까지는 0.2m/sec 이내의 차이를 나타냈다. 그러나 그 외부는 프로펠러의 크기, 벽과의 마찰로 인하여 급격히 감소한다. 5. 수심 중앙면을 따르는 수평적 유속 분포를 보면 유입부로 부터 관측부의 중앙까지는 수류변화가 거의 없으나 그 이후는 수로의 만곡에 따라 편향되었다.

  • PDF

고체추진기관 연소관단열재의 열파괴 예측기법 (Prediction Method for Thermal Destruction of Internal Insulator in Solid Rocket Motor)

  • 배지열;황인식;강윤구
    • 한국추진공학회지
    • /
    • 제27권1호
    • /
    • pp.9-16
    • /
    • 2023
  • 본 연구에서는 고체추진기관 내 연소관단열재의 열분해와 삭마를 고려하여 단열재의 열응답을 예측할 수 있는 일차원 해석기법을 개발하였다. 모델링에는 연소관단열재 내부에서 발생하는 열분해로 인한 물성변화, 숯층의 팽창 및 분해가스 이동을 고려하였다. 또한 연소가스로부터의 복사/대류 열유속을 경계조건으로 적용하였으며 단열재 표면에서 발생하는 화학적 삭마속도를 대수식으로 모델링하였다. 해석기법 검증을 위해 열전대가 설치된 시험모터에 대한 해석을 수행하였다. 해석으로 도출된 온도분포는 시험과 유사한 값을 나타냈으며 시험과 예측 열파괴두께의 오차는 0.1 mm 내외였다.

액랭식 마이크로채널 시스템 내 냉매와 범프의 열 제거 효과에 대한 연구 (Effect of Coolants and Metal Bumps on the heat Removal of Liquid Cooled Microchannel System)

  • 원용현;김성동;김사라은경
    • 마이크로전자및패키징학회지
    • /
    • 제24권2호
    • /
    • pp.61-67
    • /
    • 2017
  • 소자의 트랜지스터 밀도가 급속히 높아짐에 따라 소자 내부에서 발생하는 열 유속(heat flux) 또한 빠르게 증가하고 있다. 소자의 고열 문제는 소자의 성능과 신뢰성 감소에 크게 영향을 미친다. 기존의 냉각방법들은 이러한 고열문제를 해결하기 위해선 한계점에 다다랐고, 그 대안으로 liquid heat pipe, thermoelectric cooler, thermal Si via, 등 여러 냉각방법이 연구되고 있다. 본 실험에서는 직선형 마이크로채널과 TSV(through Si via)를 이용한 액체 냉각시스템을 연구하였다. 두 종류의 냉매(DI water와 ethylene glycol(70 wt%))와 3 종류의 금속 범프(Ag, Cu, Cr/Au/Cu)의 영향을 분석하였으며, 대류, 복사 및 액체 냉각으로 인한 총 열 유속을 계산하여 비교하였다. 냉각 전후의 냉각시스템의 표면온도는 적외선현미경을 통해 측정하였고, 마이크로채널 내 액체 흐름은 형광현미경을 이용하여 측정하였다. 총 열 유속은 ethylene glycol(70 wt%)의 경우 가열 온도 $200^{\circ}C$에서 $2.42W/cm^2$로 나타났으며 대부분 액체 냉각 효과에 의한 결과로 확인되었다.