• Title/Summary/Keyword: 열 수축 튜브

Search Result 8, Processing Time 0.024 seconds

Developing the Performance Analysis Model of the Heat-Shrink-Tube Manufacturing Process using a Simulation Method (시뮬레이션 기법을 통한 자동차용 열 수축 튜브 생산공정모델 개발)

  • Cho, Gyu-Sung;Lee, Seung-Hoon
    • Journal of the Korea Society for Simulation
    • /
    • v.19 no.4
    • /
    • pp.21-29
    • /
    • 2010
  • This research suggests a simulation model regarding the performance analysis of the Heat-Shrink-Tube manufacturing process using a simulation method. To analyze this study, firstly, we have collected the operating data from 'A' automobile parts company. Secondly, we have analyzed the collected data to apply a simulation model. Thirdly, we have developed a simulation model to experiment the process analysis and the line balancing methodology. The proposed simulation model can be executed by various input data without changing the simulation model and the performance of the Heat-Shrink-Tube Manufacturing system can be calculated by this model.

A Sudden Increase in Combustion Pressure of Gas Generator of Ducted Rocket by Thermal Choking (열 질식에 의한 덕티드 로켓 가스 발생기의 연소 압력 상승)

  • Kim, Doyeong;Shin, Kyung-Hoon;Lee, Changjin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.8
    • /
    • pp.684-691
    • /
    • 2015
  • A sudden increase in combustion pressure is observed in the ducted rocket combustion test equipped with pipe shaped and converging nozzle exhaust tubes. This study aims to understand the physical mechanism of abrupt change in combustion pressure using thermal choking in the exhaust tube. Results confirmed that the thermal choking of the flow inside the exhaust tube was responsible for the sudden increase in combustion pressure. Also, high pressure exponent of solid propellants is critical sensitive to the occurrence of thermal choking exhaust pipe. Additionally, numerical simulation showed that the sudden increase in combustion pressure was less possible in diverging pipe because thermal choking is more reluctant to occur.

A Study on Manufacturing Process Control and Monitoring System for Heat-Shrink-Tube Cutting Machine (열 수축 튜브 자동 절단 장치를 위한 공정제어 및 감시 시스템에 관한 연구)

  • Kim, Hyoung-Seok;Lee, Byung-Ryong;Yun, Ho-Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.12
    • /
    • pp.1140-1145
    • /
    • 2008
  • In conventional cutting system of Heat-Shrink-Tube, workers operate cutting system after considering about length and quantity of heat-shrink-tube. So, not only work time and production cost is increased but also material is wasted because the data that workers have to consider is so much. In this paper, an effective cutting system of heat-shrink-tube was developed to reduce production cost, work time and waste of material. The cutting system consists of a supervisory computer installed inside a control room, a on-site computer installed on the work area, and a PLC system. In the developed system, a supervisory computer send work order to the on-site computer using LAN and the on-site computer operates the cutting system of the heatshrink-tube after it makes an array production order. Also, the on-site computer reports information to the supervisory computer when an accident happened.

Enhanced Cooling Performance of Polymer Actuators Using Carbon Nanotube Composites (탄소나노튜브 복합재를 이용한 고분자 액추에이터의 냉각 개선)

  • Piao, Chengxu;Suk, Ji Won
    • Composites Research
    • /
    • v.30 no.2
    • /
    • pp.165-168
    • /
    • 2017
  • Coiled polymer actuators fabricated by twisting polymer fishing lines or sewing threads respond to heating and cooling with their contraction and relaxation. However, their actuation speed is highly dependent on the heating and cooling rates. In order to improve the actuation speed, the coiled polymer actuator was coated with polydimethylsiloxane composites. The introduction of multi-walled carbon nanotubes into the polydimethylsiloxane improved the actuation speed by about 13%.

Thermal and Electrical Properties of Polyacrylate/Carbon Nanotube Composite Sheet (폴리아크릴레이트/카본나노튜브 복합체 시트의 열적.전기적 성질)

  • Choi, A.Y.;Yoon, K.H.
    • Elastomers and Composites
    • /
    • v.46 no.3
    • /
    • pp.231-236
    • /
    • 2011
  • The polyacrylate/multi-walled carbon nanotube (MWNT) composites were prepared and investigated for the application as a counter electrode in solar cell. The electrical conductivity of the composites was increased with increasing MWNT content and with the thickness of the sheet. The surface resistivity value of the composite at 50 wt% loading of MWNT was 0.36 ${\Omega}$/sq. The thermal decomposition temperature of the composites was also increased with the MWNT contents, and the increase of $15^{\circ}C$ was observed at the composite of polyacrylate/MWNT (50/50, w/w). The increase of storage modulus of the composites was observed, especially at the higher temperature compared to polyacrylate. The dimensional change of polyacrylate decreased over $20^{\circ}C$, but that of the composite increased linearly with the temperature. The morphology of the composites stands for the good dispersion of MWNT into the polyacrylate matrix.

Usefuless of Multi-functional Gastroduodenal Coil Catheter with Phantom (팬텀을 이용한 다기능 위.십이지장관 코일 카테타의 유용성 평가)

  • Lim, Jin-Oh;Kim, Tae-Hyung;Jung, Yang-Hwa;Choi, Won-Chan;Shin, Ji-Hoon;Song, Ho-Young
    • Journal of radiological science and technology
    • /
    • v.26 no.4
    • /
    • pp.21-26
    • /
    • 2003
  • To evaluate the newly designed gastroduodenal coil catheter:in-vitro test. The coil catheter that we made in our laboratory was 150 cm. The coil that is made of stainless steel wire was composed 1.3 mm inner diameter and this coil spring was covered with heat-shrinkable polyethylene tube. To measure the length under fluorocopy, 8 radiopaque marks were attached at 5 cm, 10 cm, 11 cm, 12 cm, 13 cm, 14 cm, 15 cm, 20 cm apart from distal end of the catheter and 6, 2, 1 pores were made at 7 cm, 13 cm, 19 cm apart from the distal end. Radio-opacity and the amount of injected contrast was investigated in formerly used 5 Fr. vessel catheter, which is possible in measuring length, and newly designed coil catheter. Film density was tested for radio-opacity with autodensitometer. For measuring the volume of injected salin, the catheter was located in the acryl box(26 cm, 3 cm, 16 cm) that divided into 4 chambers. After injection 50 cc of contrast with autoinjector, the contrast's quantity in each chamber was measured with and without over the guide wire. Radio-opacity was 0.51 in 5 Fr. vessel catheter, 0.31 in newly made catheter. The amount of injected contrast was measured. In case of 5 Fr. vessel catheter, the amount was 99.5% from the distal part, there was no difference between with and without the guide wire. Otherwise, using a coil catheter, the pacentage the ejected saline was 1.17%, 18.8%, 41.8%, 38.2% from the distal part with the guide wire, 19.5%, 32.6%, 27.7%, 20.3% without the guide wire. Compare with formerly established catheter, this new coil catheter is easy to measure the length thanks to easy confirming under fluoroscopy and excellent in injecting contrast. Therefore, newly designed gastrointestinal catheter seems to be useful in gastrointestinal intervention procedure.

  • PDF