• Title/Summary/Keyword: 열 기포

Search Result 123, Processing Time 0.025 seconds

Characteristics of heat transfer and bubble around horizontal tube in a fluidized bed heat exchanger (유동층 열교환기의 수평관에서 열전달 및 기포특성)

  • 김성원;안정렬;김상돈
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2000.11a
    • /
    • pp.97-100
    • /
    • 2000
  • 유동층 열교환기 (Fluidized Bed Heat Exchanger; FBHE) 는 온도 균일성이라는 유동층의 특징을 이용하여 적당한 전열면적을 갖는 열교환관을 층 내 설치하여 일정한 양의 열을 전열시키는 것으로, 최근 순환유동층 연소로의 scale-up 을 통한 열용량 증대와 함께 고온의 재순환물질로부터 열을 회수, 연소로의 온도제어 및 열회수율의 극대화를 얻고자 재순환부에 연결하여 사용하고 있다. 또한, 가압순환유동층의 개발과 더불어 유효열전달 면적의 증대를 통한 상대적인 연소로 소형화를 위해 채택되고 있다. 특히, 유동층 열교환기는 전체 공정에서 20-60% 의 열을 회수할 수 있어, 열전달에 있어 매우 중요한 역할을 차지한다.(중략)

  • PDF

Level set method for the simulation of rising bubble based on triangular and Quadrilateral elements (삼각형 요소와 사각형 요소에 기초한 상승기포의 모사를 위한 Level set 방법)

  • Cho, M.H.;Choi, H.G.;Jeon, B.J.;Yoo, J.Y.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.10-13
    • /
    • 2011
  • A level set method is proposed to simulate the incompressible two-phase flow considering the effect of surface tension. For reinitialization of level set junction, a direct approach method is employed, instead of solving hyperbolic type equation. A mixed element is adopted, so that the continuity mid Navier-Stokes equations are solved by using the quadratic elements (six-node triangular element mid nine-node quadrilateral element), mid the level set function is solved by using the linear elements (three-node triangular element mid four-node quadrilateral element). In order to verify the accuracy mid robustness of the codes, the present methods are applied to a few benchmark problems. It is confirmed that the present results are in good qualitative mid quantitative agreements with the existing studies.

  • PDF

Effect of a Thin Wire Insert on the Bubble Rise in a Miniature Tow-Phase Closed Thermosyphon (소형 밀폐형 이상 열싸이펀에서 삽입 세선이 기포상승에 미치는 영향)

  • 김원태;이윤표
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.1
    • /
    • pp.99-109
    • /
    • 1996
  • Experimental investigations are carried out for the characteristics of bubble rise in the Miniature Two-Phase closed Thermosyphon(MTPCT) with a thin wire insert. The working fluids applied as experimental media are of three kinds: water, methanol, and ethanol. The effects of combination of the inclination with diametric ratio $\alpha$(=d$_{0}$/D$_{I}$) on rising velocity of a large bubble in the thermosyphon are explicitly analyzed. The realm of a movable bubble and the critical value of $\alpha$ are iteratively pursued to interpret the region Figures-of-Break, rooted in the governing physics relations, according to the application of working fluid. Experimental results are compared with those of analysis and critical ranges for $\alpha$ and D$_{I}$ were ascertained from comparisons.isons.

  • PDF

A Study on Performance Analysis of the Bubble Pump in Solar Water Heater System (태양열 온수기 시스템에 적용된 기포펌프의 성능평가에 대한 연구)

  • Lee, Kwang-Sung;Li, Xuesong;Jin, Zhenhua;Jeong, Hyo-Min;Chung, Han-Shik
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2310-2315
    • /
    • 2008
  • In this paper, study on performance analysis of bubble pump on the domestic solar water heater system is presented. Device of this experiment is consisted of bubble pump, solar collector and heat exchanger. At the mean time, this system have attached temperature sensors and pressure sensors at bubble pump. In addition, the flow meter was installed at outlet of heat exchanger. And then result of experimental study, average value of the heat exchange amount in heat exchanger was about 7.9kcal/hr, the maximum value of the heat amount in water tank($0.4m^3$) was 489.7kcal/hr and the maximum value of the mass flow rate in bubble pump was about $0.5{\ell}/min$.

  • PDF

An Experimental Study on Freezing Behavior of NaCl and Heavy Metal Aqueous Solution Using Freeze Concentration Method (동결농축법을 이용한 염수 및 중금속 수용액의 동결거동에 관한 실험 연구)

  • Kim, Jung-Sik;Lim, Seung-Taek;Oh, Cheol
    • Journal of Navigation and Port Research
    • /
    • v.37 no.2
    • /
    • pp.129-135
    • /
    • 2013
  • Recently, waste water treatment system is developed in small and middle size to get more economic advantage. Freeze concentration system has high thermodynamic efficiency and low energy consumption, can re-use purified water and cold energy obtained from ice. This study was experimentally performed to investigate pollution containment in frozen layer by cooling wall temperature, air-bubble flow methods, initial ice-lining thickness of frozen layer in NaCl aqueous solution and the representative heavy metals, Pb and Cr aqueous solution. As the result, a decrease in the cooling wall temperature bring a higher growth rate of ice front and the more solute was involved in frozen layer. The method to inject directly air-bubble into ice-liquid interface through ring shape nozzle gave high purity of ice compared to indirect method. Ice lining in 5mm thickness resulted in frozen layer with higher purity than 1mm thickness.

Preparation of Bio-oil from Ginkgo Leaves through Fast Pyrolysis and its Properties (은행잎 바이오매스로부터 급속 열분해를 통한 바이오-오일 생산 및 특성 연구)

  • In-Jun Hwang;Jae-Rak Jeon;Jinsoo Kim;Seung-Soo Kim
    • Clean Technology
    • /
    • v.29 no.3
    • /
    • pp.200-216
    • /
    • 2023
  • Ginkgo leaves are considered waste biomass and can cause problems due to the strong insecticidal actions of ginkgolide A, B, C, and J and bilobalide. However, Ginkgo leaf biomass has high organic matter content that can be converted into fuels and chemicals if suitable technologies can be developed. In this study, the effect of pyrolysis temperature, minimum fluidized velocity, and Ginkgo leaf size on product yields and product properties were systematically analyzed. Fast pyrolysis was conducted in a bubbling fluidized bed reactor at 400 to 550℃ using silica sand as a bed material. The yield of pyrolysis liquids ranged from 33.66 to 40.01 wt%. The CO2 and CO contents were relatively high compared to light hydrocarbon gases because of decarboxylation and decarbonylation during pyrolysis. The CO content increased with the pyrolysis temperature while the CO2 content decreased. When the experiment was conducted at 450℃ with a 3.0×Umf fluidized velocity and a 0.43 to 0.71 mm particle size, the yield was 40.01 wt% and there was a heating value of 30.17 MJ/kg, respectively. The production of various phenol compounds and benzene derivatives in the bio-oil, which contains the high value products, was identified using GC-MS. This study demonstrated that fast pyrolysis is very robust and can be used for converting Ginkgo leaves into fuels and thus has the potential of becoming a method for waste recycling.

A Study on Heat Transfer Characteristics for Removal of Absorption Heat in Absorption Process of Ammonia-Water Bubble Mole (암모니아-물 기포분사형 흡수과정에서의 흡수열 제거를 위한 열전달 특성 연구)

  • Lee, Jae-Cheol;Lee, Ki-Bong;Chun, Byung-Hee;Lee, Chan-Ho;Ha, Jong-Joo;Kim, Sung-Hyun
    • Clean Technology
    • /
    • v.7 no.4
    • /
    • pp.273-280
    • /
    • 2001
  • An absorber is a major component in the absorption refrigeration systems and its performance greatly affects the overall system performance. In this study, experimental analyses on heat transfer characteristics for removal of absorption heat in ammonia-water bubble mode absorber were performed. Heat transfer coefficients were estimated as the variations of input gas flow rate, solution flow rate, temperature, concentration, absorber diameter and height, and input flow direction. The increase of gas and solution flow rate affects positively in heat transfer. However, the increase of solution temperature and concentration affects negatively. Moreover, under the same Reynolds Numbers, countercurrent flow is superior to cocurrent flow in heat transfer performance. In addition, from these experimental data, empirical correlations which can explain easily the characteristics of heat transfer are derived.

  • PDF

Experimental study of heat transfer in the surrounding for bubble attached at the upper cooled surface of square cavity using the Thermo-sensitive Liquid-crystal Tracer (열감응액정을 이용한 사각공동내의 상단냉각평판에 형성된 기포 주위의 열전달현상 구명)

  • Kwon, Gi-Han;Eom, Yong-Kyoon
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.509-515
    • /
    • 2001
  • In a square cavity, the flow phenomena in the surrounding of the bubble attached at the upper cooled solid wall were studied by using a thermo-sensitive liquid-crystal tracer and image processing techniques. This method offers the advantage of measuring the entire flow field in a selected plane within the fluid at a given instant of time in contrast to point by point method like T/C. Quantitative data of the temperature were obtained by applying a colour-image-processing to the. visualized image. As the growing of a bubble, In a bubble size appears the flow phenomena which the direction of flow is reversed in the entire temperature and flow field. The observed phenomena are described with regard to thermocapillary convection.

  • PDF

Heat/Mass Transfer Measurements on a Film Cooled Blade with Naphthalene Saturated Coolant (나프탈렌 포화공기가 분사되는 막냉각 홀을 가진 터빈 블레이드 표면의 열/물질전달 계수 측정)

  • Lee, Dong-Hyun;Rhee, Dong-Ho;Kim, Kyung-Min;Cho, Hyung-Hee;Kim, Beom-Su
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.433-436
    • /
    • 2010
  • In this paper, heat/mass transfer characteristics on a film cooled stationary rotor blade are investigated using the naphthalene sublimation method. A row-speed annular wind tunnel with a single annular turbine stage is used. Three rows of film cooling holes are machined on the leading edge of the test blade. Detailed heat/mass transfer distributions are measured with changing the blowing rate from 1.0 to 2.0. As the blowing ratio increases, overall heat/mass transfer increases and the lower peak formed on the pressure side were disappeared.

  • PDF

Study of Pool Boiling Heat Transfer on Various Surfaces with Variation of Flow Velocity (다양한 표면에서 유동 속도에 따른 풀 비등 열전달에 관한 연구)

  • Kang, Dong-Gyu;Lee, Yohan;Seo, Hoon;Jung, Dongsoo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.4
    • /
    • pp.343-352
    • /
    • 2013
  • In this study, a smooth flat surface, low fin, Turbo-B, and Thermoexcel-E surfaces are used to examine the effect of the flow velocity on the pool boiling heat transfer coefficients (HTCs) and critical heat fluxes (CHFs). HTCs and CHFs are measured on a smooth square heater of $9.53{\times}9.53mm^2$ at $60^{\circ}C$ in a pool of pure water at various fluid velocities of 0, 0.1, 0.15, and 0.2 m/s. Test results show that for all surfaces, CHFs obtained with flow are higher than those obtained without flow. CHFs of the low fin surface are higher than those of the Turbo-B and Thermoexcel-E surfaces due largely to the increase in surface area and sufficient fin spaces for the easy removal of bubbles. CHFs of the low fin surface show even 5 times higher CHFs as compared to the plain surface. On the other hand, both Turbo-B and Thermoexcel-E surfaces do not show satisfactory results because their pore sizes are too small and water bubbles easily cover them. At low heat fluxes of less than $50kW/m^2$, HTCs increase as the flow velocity increases for all surfaces. In conclusion, a low fin geometry is good for application to steam generators in nuclear power plants.