• Title/Summary/Keyword: 열화실험

Search Result 1,099, Processing Time 0.031 seconds

A Study on the Deterioration Diagnosis Device of Pole Transformer using FFT (FFT를 이용한 주상 변압기의 열화 진단 장치에 관한 연구)

  • 윤용한;김영춘;김재철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.3
    • /
    • pp.97-106
    • /
    • 2000
  • This paper proposes on-line based a deterioration diagnosis device for diagnosis pole transformers using tan$\delta$ and FFT(fast Fourier transform). We measured tan$\delta$ and temperature to diagnose pole transformer insulating oil, diagnostic results are processed by FFT. For measuring convenience, we use R/F(radio frequency) wireless data communication module operating by secondary voltage of pole transformer. We have voltage variation test and oil temperature variation test to prove usability of proposed diagnosis device. The result of this paper shows that the proposed device can be used as deterioration diagnosis device of pole transformers.

  • PDF

A Study on Quantitative Analysis for Treeing Deterioration Diagnosis Using Acoustic Detection (음향탐지를 이용한 트리잉의 열화진단을 위한 정량적 분석에 관한 연구)

  • 이덕진;신성권;김재환
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.4
    • /
    • pp.68-74
    • /
    • 1999
  • Ths paper does acoustic detection of partial discharge using acoustic sensor in polymer. Time sequential rreasurement of acoustic emission characteristic obtained acoustic sensor deal with statistics process. and 5 characteristic quantities were introduced into this paper. Resulting fann analysis of $\psi$-AEA-n pattern (phase-acoustic emission amplitude-pulse number) and AE quantities ,it can know useful statistics quantities that AE average inception amplitude TEX>$(\overline{AEA_{inc}})$ and AE average maximum amplitude TEX>$(\overline{AEA_{max}})$ make diagnosis of the middle stage of deterioration, AE pulse number and AE average maximum phase $(\overline{\theta{max}})$ make diagnosis of the last stage of deterioration. it obtained that these AE quantities are useful for dias,mosis deterioration form experiment results.esults.

  • PDF

An Experimental Study on the Detection Characteristic of Draft Ice by Thermography System (열화상 시스템에 의한 유빙의 탐지특성에 관한 실험적 연구)

  • Cho, Yong-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.5
    • /
    • pp.302-307
    • /
    • 2017
  • Draft ice in polar regions is formed due to sea level changes and various environmental factors cause damage due to collision with offshore plants and ships for resource development. Drift ice in polar regions is a potential source of accidents for offshore plants that perform long-term operations in one place, as well as on the ship. To prevent accidents with drift ice, offshore plants and ships in polar regions use satellite image information and detection radar to detect drift ice. However, the inability to use visible satellite images at night significantly lowers the detection probability by radar for small drift ice. In this study, we used a thermal imaging system which can be operated day and night for the detection of drift ice, and carried out an experimental study on the detection characteristics of drift ice. To examine the night operation of the thermal imaging system, the experimental condition was set and the thermal image was measured according to the measurement angle change. Under this condition, the correlation was analyzed by theoretical calculating the radiant energy of the drift ice and the sea water.

Characteristics of microstructure and mechanical strength of ASTM A387-Gr.91 Steel deteriorated under high-temperature (고온 열화된 ASTM A387-Gr. 91 강의 미세 조직 및 기계적 강도 특성)

  • Jeong, Gwang-Hu;Han, Min-Su;Kim, Seong-Jong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.111-111
    • /
    • 2018
  • ASTM A387-Gr.91 강은 우수한 고온 강도, 크리이프 저항성 그리고 내산화성 등으로 인해 화력 및 바이오매스 발전 시설과 같은 고온 설비의 구조재료로 널리 사용되고 있다. 고온 환경에서 높은 강도는 탄화물과 탄질화물에 의한 석출강화가 주 요인으로 작용한다. 열처리 과정에서 Mo, Cr, Mn, 그리고 Fe는 구-오스테나이트 및 마르텐사이트 라스 입계에 $M_{23}C_6$ 탄화물로 석출되며, V, Nb, 및 N은 조직 내부에 미세한 MX 탄질화물로 석출된다. 따라서 합금의 고온 강도는 조직 내 석출물의 개수밀도와 크기에 크게 의존한다. 그러나 적용 환경의 특성 상 고온 노출에 따른 2차상 석출 및 조대화의 조직열화 현상이 발생하며, 이는 재료의 강도를 저하시킨다. 본 연구에서는 ASTM A387-Gr.91 강의 미세조직 열화에 따른 강도저하 및 파괴 양상을 고찰하는데 그 목적을 두었다. 본 연구에서 사용된 ASTM A387-Gr.91 강의 화학성분(wt, %)은 0.1 C, 0.38 Si, 0.46 Mn, 0.25 Ni, 8.38 Cr, 0.93 Mo, 0.18 V, 0.09 Nb, 그리고 나머지는 Fe 이다. 조직열화 및 기계적 강도저하 특성을 평가하기 위한 등온열화는 $650^{\circ}C$의 대기 환경에서 최대 1000시간동안 실시하였다. 열화된 시험편의 미세조직 및 탄화물에 대한 분석은 SEM과 EDS를 이용하여 실시하였다. 그리고 기계적 강도 평가는 인장실험과 비커스 경도시험을 통해 실시하였다. 또한 열화 시간에 따른 파단양상의 변화를 관찰하기 위해 인장시험편의 파단면을 SEM과 EDS를 이용하여 분석하였다. 그 결과, 열화에 따른 마르텐사이트 라스의 소실, 탄화물의 조대화, 그리고 2차상 석출의 조직 열화현상이 나타났다. 또한 기계적 강도는 조직 열화에 따라 저하되는 경향을 나타냈다.

  • PDF

Effects of PD-induced Degradation on the accumulation of Space Charges in the Polymer Insulation (고분자 절연 재료에서 부분방전에 의한 열화가 공간전하 축적에 미치는 현상)

  • Shin, Doo-Sung;HwangBo, Seung;Kang, Ji-Hoon;Han, Min-Koo
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1612-1614
    • /
    • 1997
  • 고분자 절연재료의 결함에 의하여 발생하는 부분방전은 고분자 재료의 화학적, 전기적 열화를 가져오며 때로는 전기 트리로 성장하여 재료의 절연파괴에 이르게 하기도 한다. 따라서 부분 방전 현상의 메카니즘 뿐만 아니라 측정법에 대한 많은 연구들이 있었으나 부분방전 열화가 고분자 재료에 미치는 열화과정에 대하여서는 명확한 메카니즘이 보고되지 않았다. 본 논문에서는 부분방전에 의한 고분자 절연재료 내의 공간전하 축적 현상에 대하여 연구하였다. 고분자 재료로는 현재 전력용 케이블에 주로 사용되고 있는 가교 폴리에틸렌(XLPE)를 사용하였으며, 1kHz의 주파수로6kV, 8kV, 10kv 및 11kV로 수시간 부분방전을 발생시킨 후 펄스정전응력법(PEA)으로 공간전하를 측정하였다. 실험결과 부분방전에 의하여 고분자 재료 내에 이종공간전하의 주입이 확인되었으며 따라서 부분방전에 의하여 고분자 재료가 열화되며 이러한 열화에 의한 전자의 방출율의 변화와 같은 고분자 표면의 상태 변화에 의하여 부분방전의 패턴에 지배적인 영향을 미친다. 이러한 공간전하의 축적에 의하여 부분방전 현상에 미치는 영향은 추후 보고할 예정이다.

  • PDF

Deterioration Diagnostic Techniques for Power Facilities by Analyzing Pulse-Height of leakage current (누설전류 파고분석에 의한 전력설비의 열화진단 기술)

  • 한주섭;김명진;손원진;길경석
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.10a
    • /
    • pp.367-370
    • /
    • 2001
  • This paper proposes a new deterioration diagnostic technique for power facilities by analyzing the pulse-height analysis of leakage current. Until now, various deterioration diagnostic techniques to prevent power system failures by deterioration of power facilities are suggested, and most of which measures leakage current amplitude only as a estimation parameter. In this experiment, it is known that the pulse heights of the leakage current are increased according to deterioration progress as well as there comes remarkable changes in pulse height distribution thereto. Therefore, the use of pulse height distribution in deterioration diagnostic technique makes more accurate diagnosis than the conventional method by using only leakage current value. From the application test, it is confirmed that the proposed technique has sufficient performance to diagnose deterioration of power facilities.

  • PDF

Durability of High Strength Concrete according to the amount of Admixture (혼화재의 사용량에 따른 고강도 콘크리트 내구성)

  • Kim, Dong-Baek;Lee, In-Duk;Lee, Jae-Won;Kim, Jong-Hoon
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2022.10a
    • /
    • pp.301-302
    • /
    • 2022
  • 최근 들어 염해, 콘크리트의 탄산화, 동결융해 등의 열화요인 의하여 발생할 수 있는 콘크리트의 내구성에 대한 다양한 연구가 진행되고 있는데, 이러한 열화요인은 독립적이 아닌 복합열화의 형태로 작용하게 되는데, 열화현상을 저감하는 한 방편으로 플라이애쉬와 같은 혼화재를 사용하디도 한다. 플라이애쉬는 유동성 증진을 통한 내구성의 향상과, 수화열 저감을 통한 균열감소 및 장기강도 증진 등의 효과가 있으며, 시멘트를 대체함으로써 경제적인 효과를 유발하는 장점도 가지고 있다. 그러나 플라이애쉬는 품질편차가 크고, 경우에 따라서 미연탄소분에 의한 AE제 흡착 등으로 인한 콘크리트의 내구성 및 강도를 저하시킬 수 있는 요소를 내포하고 있으므로 사용 시 주의가 필요하다. 본 연구에서는 열화를 저감하고, 내구성을 갖는 고강도 콘크리트를 제조하기 위하여 다양한 배합비의 플라이애쉬 혼입 콘크리트를 실험한 후 그 결과를 분석·고찰함으로써 내구성 콘크리트의 제작 시 혼화재로서의 적용성 및 타당성을 검증하고자 하며, 플라이애쉬를 내구성 재료로 그 활용을 극대화하고, 다양한 플라이애쉬의 사용량과 물/결합재비(W/B)에 대하여 내구성이 높은 고강도 콘크리트 제조방법을 범용화하며, 그 품질을 평가하는 것을 목적으로 한다.

  • PDF

The Estimation of Durability Factor of Deteriorated Jointed Concrete Pavement Using Image Analysis Test (화상분석 실험을 이용한 열화된 줄눈콘크리트 포장의 내구성 지수 평가)

  • Choi, Pan-Gil;Kim, Yong-Gon;Yun, Kyong-Ku;Kwon, Soo-Ahn
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.5
    • /
    • pp.31-38
    • /
    • 2009
  • The primary objective of this study was to estimate the deterioration degree of jointed concrete pavement which was major concrete pavement type in Korea. First of all, visual survey of concrete pavement was performed to observe deterioration types. In the result of visual survey, the majority of concrete pavement deterioration was investigated in joint area. It is appeared that most of the distresses are durability cracking and joint distress. Second, concrete core specimens were taken from eight locations including good section (4 locations) and bad section (4 locations) based on visual survey. The deterioration reasons of concrete pavement were analyzed with ultrasonic pulse velocity test, splitting tensile strength test, and image analysis for concrete core specimens. Among the image analysis test result for 21 concrete core specimens, only two specimens satisfied the Kansas DOT criteria of spacing factor, $250\;{\mu}m$, and the remains of 19 specimens were estimated to be above $250\;{\mu}m$. The durability factor of concrete was estimated very low. As a result, it was analyzed that the main deterioration reason of the deteriorated jointed concrete pavement was to be freezing and thawing damages.

A Study on Surface Characteristics of ACSR Transmission Line due to a Flame (화염에 의한 ACSR 송전선의 표면 특성에 관한 연구)

  • 김영달
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.173-180
    • /
    • 2003
  • This paper deals with the experimental results that apply to a new wire by an artificial flame-maker because it's difficult to directly analyze the characteristic of deterioration by a forest fire. Those results include surface characteristics for a conductor. In addition, there's been an experiment and analysis about the surface characteristics of the wire of ACSR 480$\textrm{mm}^2$ which was removed from Pohang area by a forest fire. Then, the database will be made to predict the state of deteriorated wires by a forest fire using those two data, and data necessary to diagnose the life state of an ACSR wire affected by a forest fire will be given.

Effect of Thermal Aging Temperature on Weight Loss and Glass Transition Temperature of Epoxy Adhesives (열화 온도가 에폭시 접착제의 질량변화 및 유리전이온도에 미치는 영향)

  • Park, Soo-Jin;Kim, Jong-Hak;Joo, Hyeok-Jong;Kim, Joon-Hyung;Jin, Fan-Long
    • Elastomers and Composites
    • /
    • v.41 no.1
    • /
    • pp.19-26
    • /
    • 2006
  • In this study, the effect of thermal aging temperature on the weight loss, glass transition temperature, and morphology of epoxy adhesives cured with amine (D-230), amide (G-5022), and anhydride (HN-2200) was investigated. As a result, the weight loss of three specimens was increased with increasing the thermal aging temperature. The result was attributed to the thermal aging which was occurred at the surface of adhesive specimens at high aging temperature, resulting in increasing the weight loss of the specimens. According to the DSC result, the glass transition temperature of DGEBA/D-230 and DGEBA/G-5022 samples war increased as the aging temperature increased, whereas the glass transition temperature of DGEBA/HN-2200 samples was constant above aging temperature of $150^{\circ}C$ and aging tine of 7 days. The SEM result indicated that the surface of DGEBA/G-5022 specimen showed more rough topography than that of DGEBA/D-230 or DGEBA/HN-2200 specimen after thermal aging. This could be correlated with the result of weight loss.