냉매 충전량에 따른 CO2용 수냉식 열펌프의 성능 특성에 관한 연구 (Performance Characteristics of Water-Chilling Heat Pump Using CO2 on Variation of Refrigerant Charge Amount)

  • 손창효;유태근;장승일;오후규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권5호
    • /
    • pp.558-566
    • /
    • 2007
  • The performance characteristics of water-chilling heat pump using $CO_2$ with respect to variation of refrigerant charge amount was investigated experimentally. An experimental apparatus is consisted of a compressor, a gas cooler, an expansion valve, an evaporator and a liquid receiver. All heat exchangers used in the test rig are counter-flow-type heat exchangers with concentric dual tubes, which are made of copper. The gas cooler and the evaporator consist of 6 and 4 straight sections respectively arranged in parallel, each has 2400 mm length. The experimental results summarize as the followings : As the refrigerant charge ratio of $CO_2$ heat pump system increases, the discharge pressure and compressor ratio increases, but mass flow rate of refrigerant decreases. Also the compressor work increases with the increase of refrigerant charge ratio. However, the heating and cooling capacity of $CO_2$ heat pump decreases as the refrigerant charge ratio increases. The maximum heating COP of $CO_2$ heat pump system presented at 0.25 refrigerant charge ratio. It is possible to confirm the optimum charge ratio of $CO_2$ heat pump system by the viewpoint of heating COP.

인버터 열펌프의 주파수 및 냉매봉입량 변화에 따른 시스템 성능특성의 실험적 연구 (An Experimental Study on the Performance of an Inverter Heat Pump with a Variation of Frequency and Refrigerant Charging Amount)

  • 최득관;김경천;김주상
    • 설비공학논문집
    • /
    • 제13권1호
    • /
    • pp.66-71
    • /
    • 2001
  • In the air-conditioning industry, the refrigerant charging amount is one of the most important parameters affecting the energy efficiency ratio of heat pumps. An experimental study was performed on the characteristics of an inverter driven air-to-air heat pump system with a variation of compressor frequency and charging amount of refrigerant. The frequency was altered from 40Hz to 70Hz and the charging amount was changed from 1.6kg to 2.8kg in tests. The variation of performance was measured with switching of the expansion valve on each frequency and charging amount. All the tests were performed at the Korean Standard and test conditions of the air conditioners. As results, it was found that there existed the charging amount and the level of the suction gas superheat which provided the highest energy efficiency ratio at all the frequency bands.

  • PDF

가변속 열펌프의 냉매 유량제어에 의한 난방성능 변화에 관한 실험적 연구 (An Experimental Investigation on the Variation of Heating Performance Due to the Refrigerant Flow Control in a Variable-Speed Heat Pump)

  • 김봉훈
    • 설비공학논문집
    • /
    • 제13권8호
    • /
    • pp.746-756
    • /
    • 2001
  • An experimental study was conducted to investigated the effect of refrigerant flow control on the performance of a variable-speed heat pump operating in both cooling and heating mode. For this purpose, cooling and heating capacity, EER and refrigerant mass flow rate corresponding to an electronic valve as well as a capillary tube were measured as functions of compressor speed, length of capillary tube (or valve opening of the electronic valve), refrigerant charge, and outdoor temperature. From the comparison of experimental results, it was found that the performance variation due to the electronic valve opening became significant as the operating conditions(outdoor temperature and compressor speed) deviated from the standard condition at which heating capacity and EER were rated for the indicated capillary tube.

  • PDF

이중관 열교환기를 사용한 물 대 공기 열펌프 시스템의 설계와 성능해석 (Design and performance analysis of water-to-air heat pump system using double-tube heat exchanger)

  • 한도영;박관준
    • 설비공학논문집
    • /
    • 제9권4호
    • /
    • pp.462-471
    • /
    • 1997
  • The water-to-air heat pump system requires relatively lower energy consumption and less installation space. The heat exchangers used for this system are the finned-tube type for the indoor unit and the double-tube type for the outdoor unit. Mathematical models for this system are developed and programmed in computer. Experimental data from various conditions are obtained and compared with calculated values from the computer simulation program. Differences of cooling capacity and COP are 1.25% and 0.47%, and those of heating capacity and COP are 0.51% and 0.13%, respectively. Simulation results are in good agreement with test results. Therefore, the developed program is effectively used for the design and the performance prediction of water-to-air heat pump system.

  • PDF

50 kW 냉방용 화학열펌프 시스템의 전산설계 (Computational Design of a 50 kW Chemical Heat Pump System for Air-Conditioning)

  • 서정원;김성준;이태희
    • 에너지공학
    • /
    • 제4권1호
    • /
    • pp.67-75
    • /
    • 1995
  • 50 kW 냉방용 화학열펌프에 관한 전산설계를 하기 위하여 반응기 모사용 부프로그램을 작성하였으며 전체 시스템을 위하여 상용모사기인 ASPEN PLUS를 이용하였다. 반응물로 각각 SrCl2-8/1 NH3 그리고 MnCl2-6/2 NH3를 사용하는 두 시스템에 대하여 비교 연구하였으며, 조작조건에 따라 시스템 설계치의 변화를 관찰하였다. 이로부터 향후 실용화될 화학열펌프 시스템에 대한 기본 설계자료를 제시할 수 있었다. SrCl2-8/1 NH3를 반응물로 한 경우 반응기의 UA는 6,868.2 J/(s·K), 출력은 95.2 kW이었고, 제한 성능 계수는 0.40이었다. MnCl2-6/2 NH3의 경우 UA는 1,569.7 J/(s·K), 출력은 109.0 kW이었으며 제한 성능계수는 0.34이었다. 이로부터 SrCl2-8/1 NH3을 반응물로 한 시스템이 MnCl2-6/2 NH3를 사용한 시스템보다 유리함을 알 수 있었다.

  • PDF

연간 성능을 고려한 가정용 태양열-흡수식 히트펌프의 에너지 절약효과 분석 (An Analysis of Energy Savings on the Solar-Absorption Heat Pump Systems for the Residential Use with the consideration of Annual Performance)

  • 이재효;이관수;원승호;이명호
    • 설비공학논문집
    • /
    • 제3권4호
    • /
    • pp.263-275
    • /
    • 1991
  • Studies on the annual performance of three different type of solar-absorption heat pump system (parallel type, series type, and generator type) are carried out by using the computer simulation. These include the calculation of solar energy from the solar collector, and the revision of computer package, developed by Oak Ridge National Laboratory, to predict the annual performance. Finally using weather data and load conditions, the annual performance are obtained. Results show that the annual operating costs of three solar-absorption heat pump systems are almost same values and 44% lower than that of the pure absorption heat pump system. The total annual input energys of solar-absorption heat pump systems are also about 44% lower than that of the pure absorption heat pump. The nominal size of the solar-absorption heat pump systems can be reduced to a value of 55% that of the pure absorption heat pump that would normally be specified under identical conditions.

  • PDF

엔진구동 지열 열펌프의 성능 분석(III) - 대체냉매를 이용한 증기압축식 열펌프의 운전특성 - (Performance Analysis of an Earth Coupled Heat Pump System Operated by an Engine(III) - Operating Characteristics of a Vapour Compression type Heat Pump Using Alternate Refrigerant -)

  • 김영복;이승규;김성태;송대빈;강호철
    • Journal of Biosystems Engineering
    • /
    • 제24권6호
    • /
    • pp.513-522
    • /
    • 1999
  • This study was performed to get the optimal operating conditions of an water-air compact heat pump system using R-134a. The experiments was done for three elvels of the air mass flow rate and the compressor driving speed during air-heating process. The temperature of the air at the condenser inlet and outlet was 17~23$^{\circ}C$, 36~44$^{\circ}C$, respectively. The average temperature of the refrigerant at the evaporator and condenser was 1$0^{\circ}C$, 6$0^{\circ}C$, respectively. The temperature of the refrigerant was not depending on the air mass flow rate and the compressor driving speed. The pressure of the refrigerant at the condenser inlet and outlet was ranged of 10~18.5kg/$\textrm{cm}^2$ and that at the evaporator was ranged of 3.1~3.3kg/$\textrm{cm}^2$. The pressure drop at the condenser and evaporator was about 1.5, 1.2 kg/$\textrm{cm}^2$, respectively. The performance of coefficient for air heating was about 3.3~4.0.

  • PDF

R744와 R22를 적용한 태양열 하이브리드 열펌프의 성능 시뮬레이션 비교 분석 (Simulation Analysis on Performance Comparison between R744 and R22 Solar Hybrid Heat Pump)

  • 강변;조홍현
    • 한국태양에너지학회 논문집
    • /
    • 제33권2호
    • /
    • pp.1-10
    • /
    • 2013
  • Simulation study of a solar hybrid heat pump using R744 and R22 for residential applications was carried out according to heat pump operating temperature, outdoor temperature and solar radiation. As a result, when the heat pump operating temperature increases from $40^{\circ}C$ to $48^{\circ}C$, the COP of a R744 and R22 heat pump system decrease from 2.15 to 1.7 and from 3.09 to 2.69, respectively. Besides, as the outdoor temperature rises from $3^{\circ}C$ to $11^{\circ}C$, the COP of R744 and R22 heat pump system increase from 1.73 to 2.12 and from 2.73 to 3.02. When the solar radiation increases from 10 to 20 $MJ/m^2$, the collector operating time and collector efficiency of R744 heat pump increase 10.3 times and 50.7%, respectively. The performance of R744 solar hybird heat pump is more sensitive to operation condition compared to that of R22. Besides, the solar heating system is more effective to the R744 heat pump system.

섬유벨트 열재생 시스템을 부착한 공기 열원 열펌프의 난방 성능 특성 (Performance of Air Source Heat Pump with a Fiber Belt Heat Regeneration System)

  • 유영선;장진택;김영중;강금춘;윤진하;이건중
    • Journal of Biosystems Engineering
    • /
    • 제25권5호
    • /
    • pp.385-390
    • /
    • 2000
  • The heat pump is one of heating and cooling systems driven by electricity using natural energy as a heat source. The heat pump system was mainly adopted to a cooling system or a refrigeration system. In regions with a large amount of electricity, it is used as a heating system or a heating and cooling system of houses, buildings and agricultural facilities. During cold weather, air source heat pumps do not work well because of some technical problems, such as frosting on evaporator coil when outside air temperature is below -5$^{\circ}C$. In this research, the heat regenerative technology was employed to eliminate the frosting on evaporator coil and improve the COP of the heat pump system. This fiber belt heat regeneration system(FBHRS) has very simple structure consisting of a geared motor and a porous fiber belt passing through alternatively between cold and warm air duct. The laboratory test showed that the heat pump system with a FBHRS yielded an impressive COP higher than 3.5 at the outside air temperature of -7$^{\circ}C$ in heating mode.

  • PDF

메탄올-글리세린계를 작동유체로 하는 흡수열펌프에서 흡수기 연구 (A Study on Absorber in Absorption Heat Pump with Methanol-Glycerine System as a Working Fluid)

  • 민병훈
    • 공업화학
    • /
    • 제17권1호
    • /
    • pp.111-117
    • /
    • 2006
  • 냉 난방 수요에서 일어나는 환경오염의 최소화와 화석연료 소비를 감소시키기 위해서 에너지보존을 개선시키는 것은 필수적이다. 이러한 점에서 흡수식 열펌프기술은 에너지 절약을 위해서 많은 가능성을 가지고 있다. 흡수식 열펌프는 에너지를 주입하지 않고 폐열의 이용을 높일 수 있는 방법이다. 흡수식 열펌프는 흡수기에서 흡수된 양의 증가가 매우 중요하기 때문에 흡수기 성능이 매우 중요하다. 본 연구에서는 흡수기의 성능을 개선시키기 위해서 메탄올과 글리세린을 작동유체로 하는 두 종류의 흡수기에 관한 연구를 수행하였다. 전자는 흡수기 내에 액상을 접선방향으로 공급하는 것이고 후자는 흡수기 내벽에 나선형 관을 설치하여 액상을 접선방향으로 공급하는 것이다. 실험 결과 후자가 흡수기에서 발생하는 열 및 물질전달이 향상되어 흡수성능이 증가되었음을 알 수 있었다.