• Title/Summary/Keyword: 열적

Search Result 4,283, Processing Time 0.03 seconds

Measurement of Reynolds Number Effects on Cavitation Performance in a Turbopump Inducer (레이놀즈 수가 터보펌프 인듀서 캐비테이션 성능에 미치는 영향 측정)

  • Kim, Junho;Song, Seung Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.820-823
    • /
    • 2017
  • This study experimentally investigate how the Reynolds number affect cavitation performance in a turbopump inducer using water. Cavitation performance has been determined by the static pressure measured at the inlet of the inducer. Reynolds number has been varied by varying water temperature and inducer rotational speed to maintain constant non-dimensional thermal parameter. At low non-dimensional thermal parameter, the critical cavitation number is insensitive to Reynolds number. However, at high non-dimensional thermal parameter, the critical cavitation number increased as Reynolds number increases. Thus, cavitation performance is deteriorated as Reynolds number increases when thermal effect exists.

  • PDF

Postbuckling and Vibration Analysis of Cylindrical Composite Panel subject to Thermal Loads (열하중을 받는 복합적층 원통형 패널의 좌굴후 거동 및 진동해석)

  • Oh, Il-Kwon;Lee, In
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.2 no.2
    • /
    • pp.148-156
    • /
    • 1999
  • The thermal postbuckling and vibration characteristics of cylindrical composite panel subject to thermal loads are analyzed using finite elements. The von-Karman nonlinear displacement-strain relation based on the layerwise theory is applied to consider large deflections due to thermal loads. Cylindrical arc-length method is used to take into account the snapping phenomena. Thermal snapping and vibration characteristics are investigated for various structural parameters such as thickness ratio, shallowness angle and boundary conditions. The present results show that thermal snapping changes the mode shapes as well as static deformations.

  • PDF

Nanoindentation 분석을 통한 W-C-N 박막의 열적 안정성 연구

  • Kim, Su-In;Choe, Seong-Ho;Kim, Ju-Yeong;Lee, Chang-U
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.228-228
    • /
    • 2010
  • 반도체 집적도의 비약적인 발전으로 각 박막 층간의 두께는 더욱 줄어들었고 이는 각 박막 층간의 확산에 대한 문제를 간과할 수 없게 하였다. 따라서 각 층간의 확산을 방지하기위한 확산방지막의 연구에 대한 관심도는 증가하게 되었다. 또한 본 연구에서 분석을 위하여 사용된 Nanoindenter는 박막 표면에 다이아몬드 팁을 이용하여 압입을 실시하여 이때 시표의 반응에 의한 팁의 위치(Z-축)를 in-situ로 측정하여 인가력과 팁의 위치에 대한 연속 압입곡선을 측정하게 된다. 이를 통하여 박막의 hardness와 elastin modulus를 측정하게 되고, 연속 압입곡선 분석을 통하여 박막의 표면응력 변화를 측정한다. 이 논문에서는 반도체의 기판으로 사용되는 Si 기판과 금속배선 물질인 Cu와의 확산을 효과적으로 방지하기 위한 W-C-N 확산방지막을 제시하였고, 시료 증착을 위하여 rf magnetron sputter를 사용하여 동일한 증착 조건에서 질소(N)의 비율을 다르게 하여 박막내 질소 비율에 따른 확산방지막을 제작하였다. 이후 시료의 열적 안정성 측정을 위하여 상온에서 $900^{\circ}C$ 까지 질소 분위기에서 30분간 열처리 과정을 실시하여 열적 손상을 인가하였고, 고온에서 확산방지막의 열적인 안정성을 Nanoindentation 분석을 이용하여 측정하였다. 측정 결과 박막내 질소 불포함된 박막의 경우 표면 강도는 9.01 GPa에서 194.01 GPa의 급격한 변화를 보였고, 질소가 포함된 박막은 9.41 GPa에서 43.01 GPa으로 상대적으로 적은 차이를 보였다. X-ray 분석 결과에서도 박막내 질소가 포함된 박막이 고온에서도 더 안정된 특성을 보이는 것을 확인하였다.

  • PDF

CdTe/ZnTe 다층 양자점의 결합에 따른 광학적 특성

  • Im, Gi-Hong;Kim, Beom-Jin;Jin, Seong-Hwan;Choe, Jin-Cheol;Lee, Hong-Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.277.2-277.2
    • /
    • 2016
  • 현재 화합물 반도체 나노구조는 광학적, 전기적 특성을 기반으로 하는 단전자 트랜지스터, 적외선 검출기, 레이저, 태양전지와 같은 분야에 응용하기 위한 많은 연구가 진행되고 있다. 특히 양자점은 3차원으로 구속되어 있는 상태 밀도를 갖고 있어 레이저 응용 시 낮은 문턱 전류 밀도, 높은 이득, 높은 열적 안정성을 기대되고 있지만 양자점의 운반자 수집과 열적 안정성의 한계가 여전히 존재한다. 이러한 문제를 해결하기 위해 다양한 방법이 연구되고 있으며, 그 중 단층 양자점에 비해 운반자 수집과 열적 안정성이 뛰어난 다층 양자점이 결합된 구조에 대한 연구가 활발히 이루어지고, 다층으로 성장된 양자점 구조는 양자점의 크기 분포 조절이 용이하고 양자점 층간의 전기적 결합력이 강한 특성이 있다. 본 연구에서는 분자 선속 에피 성장법(Molecular Beam Epitaxy; MBE)과 원자 층 교대 성장법(Atomic Layer Epitaxy; ALE)으로 CdTe/ZnTe 다층 양자점을 ZnTe 장벽층의 두께를 변화하면서 성장 후 광학적 특성을 연구하였다. 저온 광루미네센스 측정(Photoluminescence; PL)을 통하여 ZnTe 장벽층 두께가 증가할수록 양자점의 PL 피크가 높은 에너지로 이동함을 알 수 있었는데, 이는 ZnTe 장벽층의 두께가 증가할수록 양자점 층간의 결합력이 감소하면서 양자점의 크기가 작아졌기 때문이다. 그리고 ZnTe 장벽층의 두께가 증가할수록 PL 세기가 커지는 것을 알 수 있었는데, 이는 ZnTe 장벽층의 두께가 증가할수록 더 많은 운반자가 양자점으로 구속되기 때문이다. 또한 온도 의존 광루미네센스 측정 결과 ZnTe 장벽층의 두께가 증가할수록 열적 활성화 에너지가 커지는 것을 관찰하였고, 시분해 광루미네센스 측정을 통해 ZnTe 장벽층의 두께에 따른 운반자 동역학에 대해 연구하였다. 이와 같은 결과 CdTe/ZnTe 다층 양자점 구조에서 장벽층의 두께에 따른 광학적 특성에 대해 이해 할 수 있었다.

  • PDF

A Numerical Study on the Thermal Behavior Evaluation of Bentonite Buffer (벤토나이트 완충재의 열적 거동 평가에 관한 수치해석적 연구)

  • Yoon, Chan-Hoon;Choi, Young-Chul;Choi, Heui-Joo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.13 no.2
    • /
    • pp.99-112
    • /
    • 2015
  • In this study, laboratory test equipment was designed and installed to evaluate the thermal behavior of bentonite, which is used as a buffer in high-level waste disposal systems. The thermal analysis was conducted to verify the test results using ABAQUS, a finite element analysis code. In view of the seasonal changes seen during the test, the thermal behavior of bentonite with a temperature of outside air was evaluated. Of the cases examined, the results of the analysis model using stainless steel (Case 3) approximates to the test results, showing an error of about 1℃. The results of the thermal analysis into seasonal temperature distributions are consistent with trends seen in lab-test results. These analyses show that the effects of the thermal conductivity of the material surrounding the buffer and outside air temperature, are very important factors in the thermal behavior of bentonite. In the future, it is expected that a moisture saturation test of a bentonite buffer containing a heat source will be carried out. Therefore, the development of a numerical analysis model is required for the prediction and verification of the laboratory test results.

The Correlation of Sweating of Oil/wax Structure and Thermal Property (오일/왁스 구조의 열적 특성과 Sweating과의 상관관계)

  • Yun, Seiyoung;Kim, Jungil
    • Applied Chemistry for Engineering
    • /
    • v.24 no.2
    • /
    • pp.144-147
    • /
    • 2013
  • Sweating, which is the excretion of oil on the surface of a solid product containing several kinds of pigments in oil and is also solidified with wax, is a unique phenomenon often observed on the surface of cover make-up or lipstick. The cause of sweating is an imbalanced formula. Many studies have been conducted to decrease the symptoms of sweating in the field of cosmetics. Differential scanning calorimetry (DSC) is a thermo-analytical technique that measures the amount of heat required to increase the temperature of a sample as a function of temperature or time under certain conditions. DSC has been used to determine the thermal properties of oil/wax structures. This study investigates how the thermal characteristics correlate with the sweating symptoms. An oil/wax formulation with an optimal melting point was studied in an attempt to make a stable product by considering the thermal properties that represent minimal structural changes with temperature variation. In addition, the sweating of the oil/wax formulation was observed over a various temperature range. As a result, it was found that sweating was minimized when the structure remained static or little bit changed over a variety of temperatures.

Engineering-scale Validation Test for the T-H-M Behaviors of a HLW Disposal System (고준위폐기물 처분시스템의 열적-수리적-역학적 거동 규명을 위한 공학적 규모의 실증시험)

  • Lee Jae-Owan;Park Jeong-Hwa;Cho Won-Jin
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.2
    • /
    • pp.197-207
    • /
    • 2006
  • The engineering performance of a high level waste repository is significantly dependent upon the T-H-M behavior in the engineered barrier system. An engineering-scale test facility (KENTEX) was set up to validate the T-H-M behaviors in the buffer of a reference disposal system developed in the 2002. The validation tests started on May 31, 2005 and is now in progress. The KENTEX facility and validation test programme are introduced, and pre-operation calculations are also presented to give information on the sensitive location of sensors and operational conditions. This test will provide information (e.g., large-scale apparatus, sensors, monitoring system etc.) needed for 'in-situ' tests, make the validation of a T-H-M model for the T-H-M performance assessment of the reference disposal system, and demonstrate the engineering feasibility of fabricating and emplacing the buffer of a repository.

  • PDF

A Study on Evaluation of Thermal Environment using Heat Stress Indices for Deep Coal Mine in Korea (열적지표를 적용한 국내 고심도 석탄광산의 열환경 평가 연구)

  • Park, Seon-Oh;Roh, Jang-Hoon;Kim, Jin
    • Tunnel and Underground Space
    • /
    • v.24 no.2
    • /
    • pp.166-175
    • /
    • 2014
  • In this study, the thermal environment in a large scale coal mine located in Taebaek, Gangwondo was assessed by a field survey. In order to estimate the thermal environment, various heat stress indices such as WBGT, HSI, ESI, KATA index and effective temperature were investigated. Correlation analysis was also conducted. It was found that the thermal environment in most workplace was high. In particular, the correlation coefficient between HSI reflected in physiological fatigue characteristic and the maximum sweat evaporation heat was -0.834. This shows that the correlation coefficient have the most influence on HSI index. The factor which has the most influence on the maximum sweat evaporation heat is velocity of air. The thermal environment of high-depth coal mines is likely to be improved by installing a structure that enables the maximum prevention of extended digging, air doors, or the leakage of the inflow of air in the first shaft.

A Study on the Thermal Behaviors of Disk Brake and Pad by Friction Heat (디스크 브레이크와 패드의 마찰열에 의한 열적거동에 관한 연구)

  • Han, Seung-chul
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.12
    • /
    • pp.287-292
    • /
    • 2019
  • This paper analyzes the thermal behaviors of genuine discs used in automobiles and discs coming out of tuning products through FEM analysis. Modeling with genuine disk modeling and tuning disks Model-1, Model-2, Model-3 and analyzing the disk rotation speed was set to 1000rpm. When the brake is operated, the thermal behavior of the disk surface, such as the operating temperature caused by the disk and pad contact, the friction surface temperature after the disk stop, and the thermal deformation, were analyzed. When the brake was activated (0-4.5 seconds), the tuning disk showed 34℃ higher than the original disk, and after the disk stopped (40.5 seconds), the tuning disk was analyzed 18℃ lowe, deformation due to the disk heat was deformed by 0.3mm for the tuning disk. Although there is an effect to reduce the fading phenomenon due to the thermal behavior of the pure disk and the tuning disk, it can be observed that there is no significant change in the thermal behavior due to the hole processing and the disk surface processing of the tuning disk.

A Study on Application of Remote Sensing for Thermal Plume Analysis (온배수 확산분석을 위한 Remote Sensing 활용에 관한 연구)

  • Yeu, Bock-Mo;Cho, Gi-Sung
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.1 no.2 s.2
    • /
    • pp.185-194
    • /
    • 1993
  • In this research, the image obtained by TM platformed in the LANDSAT-5 and the terrestrial infrared image obtained by the Thermo Tracer were employed in order to search the distribution of industrial thermal plume discharged into seas. Sea surface temperature distributions were deduced based on the infrared band 6 in the TM image of the LANDSAT by employing the transformal formula provided by the CSFC of the NASA and post-calibration values. The temperature distributions were also obtained with the processing mode of the TH1100 series from the terrestrial thermal image or the Thermo tracer. According to the results of the image analyses with this methods, it was found that sea surface temperatures in shallow coastal area largely affected by the temperatures of the freshwater and inland and that the range and the area of distribution of the thermal plume can be visualized quantitatively. Furthermore, when the terrestrial thermal infrared scanner is used, the more details of the distribution range can be obtained, and the image results are comparable to those obtained from the LNADSTA.

  • PDF