• Title/Summary/Keyword: 열원분포

Search Result 96, Processing Time 0.026 seconds

A Study on Heat Source Model to Creep Feed Grinding (크?피드 연삭에서 열원 모델에 관한 연구)

  • Jeong, Jong-Dal;Jeong, Hae-Do;Choe, Heon-Jong;Kim, Nam-Gyeong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.2
    • /
    • pp.171-176
    • /
    • 2001
  • This study focuses on the energy partition and heat flux distribution in creep-feed grinding. From the measurements of transient grinding temperature in the workpiece which the thermocouple was embedded, the overall energy partition to the workpiece was estimated with moving heat source theory using the developed scalene triangle heat model. The energy partition was calculated as 3.75% in down grinding smaller than 5.3% in up grinding. Also, the scalene triangle heat model was confirmed as the most optional heat model in correspond to the experimental data. Then, the heat flux distribution was calculated from temperature responses. The heat flux is negative behind the grinding zone where fluid was applied. In this experimental result, the total heat flow to the workpiece per unit width obtained by integrating the positive heat flux was 0,7W/mm for down grinding.

  • PDF

Transient heat conduction in rock mass around arch shape cold storage cavern and estimation of in-situ thermal properties (아치형 냉동저장공동 주위암반의 비정상상태 열전도 특성 및 열물성 평가)

  • Synn, Joong-Ho;Park, Yeon-Jun;Kim, Ho-Yeong;Park, Chan
    • Tunnel and Underground Space
    • /
    • v.9 no.1
    • /
    • pp.27-35
    • /
    • 1999
  • The characteristics of heat conduction for the heat source boundary like an arch shape cavern are different from those for the semi-infinite or circular boundary which can be driven theoretically. A new form of transient heat conduction equation in rock mass around the arch shape cavern is evaluated with analyzing the pattern of the rock temperature distribution measured at the cold storage pilot plant. The new equation, which is driven by adopting a shape function, $SF=\sqrt{logx_0/log(x_0+x)}$ to the solution for a semi-infinite boundary, has the semi-radial form of temperature variation with distance. And, thermal properties of rock mass are estimated by comparing the rock temperature distributions by this equation with those by measurement. Thermal conductivity and specific heat of rock mass are estimated as giving the difference of 20~25% compared to those of laboratory scale. This difference seems to be caused by discontinuity like joint and water content in rock mass.

  • PDF

Characteristics of Atmospheric Circulation and Heat Source related to Winter Cold Surge in Korea (한반도 겨울철 한파와 관련된 대기 순환과 열원의 특성)

  • Kim Maeng-Ki;Shin Sung-Chul;Lee Woo-Seop
    • Journal of the Korean earth science society
    • /
    • v.26 no.6
    • /
    • pp.560-572
    • /
    • 2005
  • This study investigates the characteristics of atmospheric circulation and the heat source $(Q_1)$ related to the winter cold surge in Korea from 1979 to 1999. The occurrence frequency of cold surge is about one event per year and $60\%$ of the total events occurred during the former period, before 1989. During the cold surge, the pressure pattern shows more dominant east-west dipole circulation pattern in the lower troposphere and the effect of upper level trough is stronger than normal cases. Temperature falling pattern over Korea shows that the pattern opposite to the temperature structure over Lake Baikal and temperature change has opposite signs between the low-middle level and upper level, with the boundary at 400 hPa. The analysis of heat source shows that atmospheric cooling by cold advection during the cold surge is balanced by adiabatic warming due to downward motion, indicating that the movement path of cold core is associated with that of heat sink. Therefore, the movement mechanism of the heat source and sink should be well known for understanding the maintenance mechanism of cold surge and predicting cold surges.

Study on Temperature Distribution for Various Conditions of Moving Heating Source During Line Heating Process (선상가열시 이동열원 조건에 따른 가열 판재의 온도분포에 관한 연구)

  • Choi, Yoon-Hwan;Lee, Yeon-Won;Choi, Kwang
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.5
    • /
    • pp.617-624
    • /
    • 2010
  • Line heating is a manufacture method, which was widely used to machining a curved surface in the ship construction. The qualities using by line heating are very difference compare to the proficiency level of the engineer. So it's mainly depend on the automation equipment instead of the proficiency level engineer. In this study, it would be investigate the temperature distribution of the heating plate, which was used by the automation equipment according to line heating. The main factors are the moving velocity of the heating source, strength and the heating method separately, in temperature distribution while line heating. In this paper, it was investigated the temperature change with the vary of each three variables. The numerical result showed that peak temperature decrease if the moving velocity of the heating source increased. It can also calculate the change quantitatively that the peak temperature and temperature distribution changed linearly with the vary of the heating source.

Development of the Dryer with a Heat Source of Carbon Nanofibers (탄소나노섬유를 열원으로 적용한 세탁물 건조기의 개발)

  • Lee, Jung-Hwan;Won, Sang-Yeon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.23 no.3
    • /
    • pp.25-34
    • /
    • 2018
  • This paper presents a heating source of carbon nanofibers for the efficiency and the drying performance of laundry dryer, and focuses on the applicability-evaluation of its source. To design the proposed heating module, experiments were conducted in terms of surface temperature and surface temperature distribution characteristics of carbon nanofiber lamps. The surface temperature of the lamps increased linearly with increment of a current to flow a lamp and revealing the increasing pattern as the length of the ramps is shorter. The proposed heating source was evaluated based on drying efficiency, moisture evaporation rate at laundry, and internal temperature of a drum during drying process. The drying efficiency satisfied a 45% which is specified in KS C 9319. The moisture evaporation rate and the internal temperature of the drum were respectively 98.88% and $61.1^{\circ}C$, which are similar to that of S's company dryer. From the evaluation and actual drying test results, the proposed carbon nanofiber lamp heating module is considered to be applicable as a heat source for laundry dryer in terms of drying efficiency and drying performance. it is possible to obtain a heat source at a high temperature, an excellent calorific value, an improvement in drying performance, and an effect of sterilizing laundry due to the emission of far-infrared rays. In addition to the applicability, the difference of the drying efficiency between the dryers was analyzed in detail based on the power consumption of the heat sources.

Heating Performance of Ground source Heat Pump using Extruding Ground Water (유출지하수 열원 지열히트펌프시스템의 난방성능)

  • Park, Geun-Woo;Lee, Eung-Youl
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.460-465
    • /
    • 2007
  • 유출지하수는 지하공간이 깊고 넓게 분포하는 건물에서 자연적으로 유출되어 배출되는 낮은 심도의 지하수이다. 본 연구에서는 신축된 교회건물에서 유출되는 지하수를 열원으로 밀폐형태와 개방형태의 열교환기를 활용하여 각각 5RT급 히트펌프시스템을 난방모드로 운전한 결과를 정리하였다. 실험은 난방순환수의 온도를 $43{\sim}49$ $^{\cdot}C$ 범위에서 제어하면서 진행하였으며, 시스템 COP에 있어서 밀폐형은 $4.12{\sim}4.75$, 개방형은 $3.42{\sim}3.98$의 범위에서 측정되었다. 이는 기존의 지열히트펌프시스템의 COP와 대동 소이한 우수한 성능이라고 판단된다. 또한 펌프동력을 제외한 히트펌프 자체 난방COP에 있어서 밀폐형은 $4.69{\sim}5.81$, 개방형은 $4.38{\sim}5.43$의 범위에서 나타났다. 유출지하수의 온도가 겨울철에도 약 $12{\sim}14^{\cdot}C$를 유지하므로 히트펌프와 시스템전체의 COP가 매우 우수한 값을 나타내고 있음이 확인되었다.

  • PDF

Non-Fourier 열전달에 대한 소고

  • 김우승
    • Journal of the KSME
    • /
    • v.31 no.8
    • /
    • pp.735-744
    • /
    • 1991
  • 확산모델과 파모델의 결과에 있어 큰 차이가 일어나는 경우를 요약하면 다음과 같다. 1) 과도기 간이 짧다. 2) 작동온도가 아주 낮다. 3) 온도구배가 상당히 크다. 이때3)의 경우는 서로 다른 물질들이 접촉된 경우 또는 높은 열유속이 있는 경우 또는 얇은 표면층 등을 갖는 문제들의 공 통적인 특징이다. Non-Fourier 열전도 문제를 이용해 온도 분포를 예측해야 하는 실제적인 몇 가지 예를 살펴 보면 레이저 기술 또는 절대온도 영(zero)에 접근하는 온도에서의 액체 헬륨을 다루는 저온공학연구 또는 1/$10^{6}$Inch 정도의 표면조도가 관심사인 정밀공학 등을 들 수 있다. 또한 상당히 높은 강도의 열원이 작용될 때 고체에서의 크랙이나 보이드(void) 같은 국소 결함은 확산거동이 나타나기에 요구되는 시간보다 짧은 시간 구간에서 발생되어질 수 있으며, 크랙발생의 방향과 같은 것들은 hyperbolic 모델에의해 예측되어져야만 한다. 특히 움직이는 열원 또는 propagating crack tip을 갖는 경우에 그들 주위에서의 온도장을 규정짓는 가장 중요한 변 수는 열마하수 M이며, 아음속에서 초음속 영역으로 천이될 때 물리적 양들의 변화에 있어서 일어나는 현상들은 열충격의 형성에 기인하는데 이러한 현상들은 확산 모델로서는 예측될 수 없는 특징들이다. 이상에서 살펴볼 때 non-Fourier 모델에 대해 관심을 기울일 필요가 있다고 사료된다.

  • PDF

Analysis of temperature rises of three phase squirrel cage induction motor considering the nonuniform distribution of thermal sources (축방향으로의 열원분포 불균일을 고려한 3상 농형유도전동기의 온도상승 해석)

  • Jun, C.S.;Kim, B.K.;Kwon, B.I.;Park, S.C.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.34-37
    • /
    • 1997
  • The nonuniform thermal sources of a squirrel cage induction motor are obtained from the losses calculated by the nonlinear complex finite element analysis considering skew effects. Then, temperature rises of the motor are calculated using thermal equivalent network analysis and compared with some experimental values.

  • PDF

A Temperature Distribution Analysis of 2 MVA mold transformer for power distribution power system (2 MVA 배전용 몰드변압기의 온도분포 해석)

  • Chung, Hyun-Koo;Woo, Sung-Hyun;Kim, Young-Bae;Tang, Hyeong-Taek;Shin, Pan-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2009.04b
    • /
    • pp.44-45
    • /
    • 2009
  • 본 논문은 3상 22.9 kV/380 V, 2[MVA] 몰드변압기의 온도 분포를 FEM(FLUX2D)를 이용하여 수행하였다. 변압기의 코어 손실과 권선손실에 의한 열원을 계산하고, 그 결과를 이용하여 코어와 권선의 온도 분포를 해석하였다. 최종목적은 열의 분포를 균등화하여 변압기의 효율과 용량을 극대화 시키는 것이다.

  • PDF