• Title/Summary/Keyword: 열성형

Search Result 202, Processing Time 0.028 seconds

Development of a Cooling System for a Concentrating Photovoltaic Module (고집광 태양전지 모듈의 냉각시스템 개발)

  • Kim, Tae-Hoon;Do, Kyu-Hyung;Choi, Byung-Il;Han, Yong-Shik;Kim, Myung-Bae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.6
    • /
    • pp.551-560
    • /
    • 2011
  • In this paper, a cooling system that includes a heat spreader and a natural convective heat sink is proposed for the cooling of a concentrating photovoltaic (CPV) module. The heat spreader and the natural convective heat sink are designed on the basis of previous analytical investigations. In order to evaluate the proposed cooling system, we conducted experimental investigations varying the heat rate and the inclined angle of the cooling system. From the experimental results, it is found that the proposed cooling system satisfies the design constraints for good operation of the CPV module. Finally, a correlation is suggested for estimating the effects of the heat rate and the inclined angle on the thermal performance of the natural convective heat sink is suggested.

Inherited metabolic diseases in the urine organic acid analysis of complex febrile seizure patients (복합 열성경련 환자의 소변 유기산 분석에서 나타난 유전대사질환)

  • Cheong, Hee Jeong;Kim, Hye Rim;Lee, Seong Soo;Bae, Eun Joo;Park, Won Il;Lee, Hong Jin;Choi, Hui Chul
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.2
    • /
    • pp.199-204
    • /
    • 2009
  • Purpose : Seizure associated with fever may indicate the presence of underlying inherited metabolic diseases. The present study was performed to investigate the presence of underlying metabolic diseases in patients with complex febrile seizures, using analyses of urine organic acids. Method : We retrospectively analyzed and compared the results of urine organic acid analysis with routine laboratory findings in 278 patients referred for complex febrile seizure. Results : Of 278 patients, 132 had no abnormal laboratory findings, and 146 patients had at least one of the following abnormal laboratory findings: acidosis (n=58), hyperammonemia (n=55), hypoglycemia (n=21), ketosis (n=12). Twenty-six (19.7 %) of the 132 patients with no abnormal findings and 104 (71.2%) of the 146 patients with statistically significant abnormalities showed abnormalities on the organic acid analysis (P<0.05). Mitochondrial respiratory chain disorders (n=23) were the most common diseases found in the normal routine laboratory group, followed by PDH deficiency (n=2) and ketolytic defect (n=1). In the abnormal routine laboratory group, mitochondrial respiratory chain disorder (n=29) was the most common disease, followed by ketolytic defects (n=27), PDH deficiency (n=9), glutaric aciduria type II (n=9), 3-methylglutaconic aciduria type III (n=6), biotinidase deficiency (n=5), propionic acidemia (n=4), methylmalonic acidemia (n=2), 3-hydroxyisobutyric aciduria (n=2), orotic aciduria (n=2), fatty acid oxidation disorders (n=2), 2-methylbranched chain acyl CoA dehydrogenase deficiency (n=2), 3-methylglutaconic aciduria type I (n=1), maple syrup urine disease (n=1), isovaleric acidemia (n=1), HMG-CoA lyase deficiency (n=1), L-2-hydroxyglutaric aciduria (n=1), and pyruvate carboxylase deficiency (n=1). Conclusion : These findings suggest that urine organic acid analysis should be performed in all patients with complex febrile seizure and other risk factors for early detection of inherited metabolic diseases.

A Research on the Actual Condition of Passive Solar Post Offices (자연형 태양열 우체국사 실태 조사연구)

  • Lim, Sang-Hoon;Auh, P.Chung-Moo;Jeon, Hong-Seok
    • Solar Energy
    • /
    • v.10 no.1
    • /
    • pp.80-91
    • /
    • 1990
  • The purpose of this study is to provide materials necessary for planning and designing of passive solar post offices by comparing and analyzing the satisfaction degree on old passive solar post office environment characteristics according to the post office pattern. In conclusion, passive solar systems are effective and economical when they are applied to post offices for heating systems.

  • PDF

A Study on the Reduction of Temperature Damage in Concrete Pavement (콘크리트 포장에서 발생하는 온도피해 저감에 관한 연구)

  • Jae-Don Kim;Il-Young Jang
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.2
    • /
    • pp.305-312
    • /
    • 2023
  • Purpose: Although the damage caused by abnormal temperatures is extensive, blow-up or black ice is typical in concrete structures. In this study, PCM with high phase change energy was mixed with concrete to reduce temperature damage to concrete pavement. Method: In order to reduce temperature damage to low temperatures and high temperatures, capsule-type PCM with phase change temperatures of 4.5℃ and 44℃ was replaced by 10%, 30%, and 50%, and thermal performance experiments and compressive strength experiments were conducted using thermocouples and variable chambers. Result: As a result of the thermal performance experiment, it was found that the incorporation of PCM improves temperature resistance by up to 25% or more, and increases thermal resistance at all temperatures with high specific heat when substituted in large amounts. As a result of the compression strength experiment, a substitution of 30% or more resulted in a decrease in the compression strength, and a large strength difference was shown based on the phase change temperature of the PCM. Conclusion: The incorporation of PCMs has been shown to increase the thermal performance of concrete, with the greatest increase in thermal performance near the phase change temperature of PCM. In addition, a small strength reduction of 10% to 20% occurs at the highest substitution rate of 50% substitution, so there is no significant problem with usability, and additional PCM substitution is expected to improve thermal performance.

A Research on the Actual Condition of Passive Solar School Buildings (자연형 태양열 학교의 실태 조사 연구)

  • Lim, S.H.;Jeon, H.S.;Auh, P.C.;Lee, N.H.
    • Solar Energy
    • /
    • v.10 no.3
    • /
    • pp.66-78
    • /
    • 1990
  • The purpose of this study is to provide materials necessary for planning and designing of passive solar school buildings by comparing and analyzing the satisfaction degree on old passive solar school building environment characteristics according to the school building pattern. In conclusion, passive solar systems are effective and economical when they are applied to school buildings for heating systems.

  • PDF

A Study of Parametric Effects on the Thermal Performance of Flat-Plate Liquid-Heating Solar Collectors (평판형 액체식 집열기 의 각종 변수 가 집열기 의 열성능 에 미치는 영향)

  • 전문헌;윤석범;추교명
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.8 no.2
    • /
    • pp.145-153
    • /
    • 1984
  • In the present work, a computer simulation is performed employing Hottel-Whillier-Bliss model for thermal performance of solar collectors. The major collector parameters examined in the computer simulation are: number of transparent glass covers(N), thermal emissivity of the absorbing plate surface (.epsilon.$_{P}$), absorptivity of absorber plate (.alpha.$_{p}$), flow rate per unit area of collector (G), $L_{b}$ / $k_{b}$ of insulation material, tilt angle of collector (S), and solar insolation(I). By varying numerical values of the major collector parameters around their typical values, the corresponding variations in thermal efficiency curves are examined. In addition, an experimental investigation has been carried out with a slightly modified KAIST collector test loop under a real sun condition in order to compare with the simulation results, examine the applicability of the mathematical model of the collector thermal performance, and study the effect of variation of flow rate (G) on thermal efficiency and the range of optimum flow rate.e.

Experimental Study on the Heat Transfer Characteristics of the Solar Hot Water Storage Tank (태양열 축열조 열전달 특성에 관한 실험적 연구)

  • 엄태인;강용혁;유창균;곽희열;문승현;윤현식;조재광;나은수
    • Journal of Energy Engineering
    • /
    • v.10 no.1
    • /
    • pp.24-32
    • /
    • 2001
  • 본 축열탱크 열전달에 관한 실험적 연구는 국내에서 개발하고 있는 태양열 온수기용으로 현재 널리 이용되고 있는 탱크-코일 방식의 문제점을 해결하면서 열전달 효율이 높은 2중 축열탱크를 개발하기 위한 것이다. 2중 축열탱크의 용량은 100리터로서 수평 및 수직형으로 설치하여 실험이 가능하도록 설계.제작하였고 탱크내부의 온도는 길이방향 및 반지름 방향으로 각각 등간격으로 설치하여 측정하였고 집열매체의 입.출구온도를 동시에 측정하였다. 실험결과는 (1) 축열탱크의 형태에 관계없이 축열탱크와 열교환을 하는 열매체의 유량이 증가할수록 열전달량은 증가한다. (2) 축열탱크의 형태에 따른 탱크내부 물의 온도 상승속도는 수직형(b)인 경우가 가장 크고, 그 다음 수직형(a), 수평형의 순으로 나타났다. 따라서 이중탱크형의 축열탱크는 수평형 보다 수직형이 동일한 용량의 축열매체 온도를 신속히 상승시킬 수 있다. 아울러 열성층화에 의하여 고온의 축열매체를 이용할 경우 수직형 축열탱크가 더욱 우수한 결과를 나타낸다. (3) 축열탱크 열전달계수(UA) 값은 ( $T_{in}$ - $T_{out}$)/$\Delta$ $T_{m}$ 의 크기에 좌우되며, 열전달계수를 설치방법에 따라 비교하면 수직형(b)>수직형(a)>수평형의 순서로 나타났다.다.

  • PDF

THE WIND VELOCITIES DRIVEN BY ALFVEN WAVES IN 31 CYG (Alfven Wave에 의한 31 Cyg의 Wind 속도)

  • 김경미;최규홍
    • Journal of Astronomy and Space Sciences
    • /
    • v.8 no.1
    • /
    • pp.63-72
    • /
    • 1991
  • 31Cyg는 Aur형의 장주기 쌍성으로, 확장된 대기를 갖는 초거성과 뜨거운 주계열성으로 이루어져 있다. 초거성의 wind는 질량 손실률이 크고, 차갑고, 낮은 terminal velocity를 갖는데, 일반적으로 Alfven wave가 wind mechanism으로 받어들여지고 있다. 이 논문에서는 31 Cyg에 대해 Alfven wave에 의한 모델을 적용하여 운동방정식을 직접 적분하였는데, 그 terminal velocity가 50∼80km/s로 관측값과 잘 들어 맞았다. 그리고 그 결과를 Kuin과 Ahmad(1989)의 경험적인 모델과 비교하였다.

  • PDF