• Title/Summary/Keyword: 열량값

Search Result 203, Processing Time 0.022 seconds

Change of Heating Value of Cow Manure According to Pre-treatment (전처리 방법 적용에 의한 우분의 열량값 변화)

  • Jeong, Kwang-Hwa;Kim, Jung-Kon;Lee, Dong-Jun;Lee, Dong-Hyun;Cho, Won-Mo
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.23 no.4
    • /
    • pp.63-73
    • /
    • 2015
  • This study was carried out to evaluate the change of heating value of cow manure by applying pre-treatment process. Three types of treatment precess; Composting, Dry anaerobic digestion and Physical compression were applied as a pre-treatment method. Composting and anaerobic digestion of cow manure were cause of caloric value reduction of the cow manure. The heating value of cured compost was 5% lower than that of initial composting material. The heating value of dry anaerobic digestion residue was 25.7% lower than that of fresh cow manure. By physical compression of cow manure, heating value and VS/TS ratio (Volatile solids/Total solids ratio) of compressed cow manure were higher than that of fresh cow manure. On the other hand, heating value and VS/TS ratio of leachate generated by compression process were lower than those of fresh cow manure.

Air-Fuel ratio Control Technology Corresponding to High Heating Value Variation for Aluminum Melting Furnace (알루미늄 용해로의 열량변동대응 공연비제어기술)

  • Lee, Joongsung;You, Hyunseok;Han, Jeongok
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.131-134
    • /
    • 2015
  • 국내 천연가스 열량제도를 현행 표준 열량제 $10,400kcal/Nm^3(43.54MJ/Nm^3)$에서 중간 조정기간을 두고 2012.07.01부터는 최저 $10,100kcal/Nm^3(42.28MJ/Nm^3)$을 유지하고 2015년 이후 $9,800(41.1MJ/Nm^3){\sim}10,600kcal/Nm^3(44.4MJ/Nm^3)$ 열량범위제도로 변경 추진되고 있다. 산업현장에서 열량변동을 측정하여 공연비 제어기술을 개발하고자 60ton Al 용해로에 열량대응기술 개발을 위한 내용으로 열량측정시스템설치 및 열량 값과 연계하여 공연비 제어기술개발연구 내용으로 결과는 다음과 같다. 단순히 표준열량으로 에 맞춰 프로그램된 제어로직에 열량변동에서 검출된 신호를 이용하여 연료보정 값을 추가한 로직을 재구성할 필요가 있다. 이 혀장의 경우는 용탕의 온도가 목표온도 근처까지 올리기가 어려워진 상황으로 주로 공급열량 저열량화에 따른 과잉공기영향으로 온도상승이 어려워 보이며 적절한 공연비로 최적화 되면 이러한 문제가 개선되리라 생각된다.

  • PDF

Digital Calori-Meter Auto-Testing System Design (디지털열량계 자동검사시스템 설계)

  • 박재삼
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 2000.11a
    • /
    • pp.729-736
    • /
    • 2000
  • 본 논문은, PC의 프린터 포트에 연결하여, 디지털적산열량계의 정확한 작동여부를 검사함으로써 생산된 디지털열량계의 품질을 테스트 할 수 있도록 하는 장치 설계에 관하여 연구한 것으로, 본 논문에서 설계된 장치를 사용하면 일시에 최대 13개의 디지털 열량계를 테스트할 수 있다. 본 장치는 열량계연산부, 열량계지시부, 제어부, PC로 구성되어 있으며, 본 장치를 이용하면 열량계의 송류온도, 환류온도, 온도차등이 정확하게 측정되고 있는가를 테스트 할 수 있고, 열량계의 연산부가 열량을 오차범위 내에서 연산하는가를 테스트하여 열량계의 합격/불합격을 판정할 수 있으며, 열량계가 불합격 판정을 나타낼 경우, 연산부의 측정값을 읽어 불합격의 원인을 추적할 수 있고, 테스트한 결과를 데이터베이스화하여 파일로 저장할 수 있으므로, 테스트결과 보관, 프린트 등이 가능하다.

  • PDF

System Implementation for Fair Automatic Heating Operation Based on Spatial Distributing and Zonal Calorie Measuring (공간분활 및 영역열량측정에 의한 공평 자동난방운영시스템 구현)

  • Han, Sang Cheol;Ryu, Kwang Ryol
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.8
    • /
    • pp.910-916
    • /
    • 2019
  • This paper describes the system implementation of the heating operation based on spatial distributing and zonal calorie measuring and analyzing of houses to calculate the fair amount of the heating meterage automatically. The heating space is distributed into 4 zones, which the flow rate and calories are checked by one meter respectively. The system is composed of a heating sources, adjuster of thermostat, valve controller, PC converter and total monitering. The returning temperature in the spatial zones is measured for the heating calorie to calculate the zonal calories according to the rooms temperature. The proposed system results in error by 1% or less in comparing with the dedicated experimental equipment, and reduces energy cost by 7% from conventional system. The fair checking system will be enhanced with building energy management system in the future.

Study on Characteristics of Change in Calorific Value and Carbon Emission Factor of Domestic Petroleum Energy Source (국내 석유계 에너지원의 열량 및 탄소배출계수 변화 특성 연구)

  • Doe, Jin-woo;Lim, Wan-gyu;Kang, Hyung-kyu;Hwang, In-ha;Ha, Jong-han;Na, Byung-ki
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.1046-1057
    • /
    • 2017
  • Country-specific emission factors should be developed and used instead of IPCC defaults to improve national GHG inventories to Tier 2 and above. Since the country-specific emission factors depend on the type of energy source, energy process, and time trend, identifying the value of each energy source is an important part of building an accurate inventory. In this study, calorific value and carbon emission factor for petroleum energy sources on the basis of calorific value conversion standard for energy source, which are notified in Korea, are collected by 2013 and 2016, and calorific value, carbon content and carbon emission factor And a comparative analysis was conducted. In addition, net calorific values and carbon emission factors calculated for each petroleum based energy source are compared with those shown in 2006 IPCC Guideline.

A Study on fire investigation & calorie analysis of main trees in Go-sung wildfire land (고성산불지역에서의 화재조사와 주요수목의 열량분석에 관한 연구)

  • 김동현;고재선;최세환;김광일
    • Fire Science and Engineering
    • /
    • v.13 no.1
    • /
    • pp.31-36
    • /
    • 1999
  • This paper contained an actual investigation of a wildfire which broke out on 23 April R 1996 in Go-sung Kun, Kang-won Do examined the calories and the total calories of the m main trees which were Quercus variabillis and Pinus densiflora. There were three important f fire spread factors which were weather condition, fuel condition and terrain. The weather c condition was the most dangerous alarm level. The fuel condition having a high calory v value, Pinus densiflora made up 63% of the forest. Terrain of the forest were mostly c covered by steep slopes and complicated line construction. This experimental calorie study a about Pinus densiflora and Quercus variabillis showed that Pinus densiflora had 13,34kcal/g a and Quercus variabillis had 9.64kcal/g. In the case of weight loss of pyrolysis, Pinus densiflora had a higher percentage rated 35.71~10.05% than Quercus variabillis. Accordingly, Pinus densiflora showed lower than Quercus variabillis in heat resistance.

  • PDF

The Applicable Investigation of Response Surface Methodology(RSM) for the Prediction of the Ignition Time, the Heat Release Rate and the Maximum Flame Height of the Interior Materials (내장재의 발화시간, 열방출율 및 최대화염 높이의 예측을 위한 반응표면방법론의 활용성 고찰)

  • Ha, Dong-Myeong
    • Fire Science and Engineering
    • /
    • v.20 no.2 s.62
    • /
    • pp.14-20
    • /
    • 2006
  • The aim of this study is to predict the ignition times and the HRR(heat release rate) for building interior materials. By using the literature data and RSM(response surface methodology), the new equations for predicting the ignition time and the HRR of building interior materials are proposed. The A.A.P.E.(average absolute percent error) and the A.A.D.(average absolute deviation) of the reported and the calculated ignition times by means of the thickness and the density were 4.35 sec and 1.57 sec, and the correlation coefficient was 0.987. The correlation coefficient of the reported and the calculated the net HRR by means of burner width and power was 0.983. Also the correlation coefficient of the reported and the calculated the total HHR by means of burner width and power was 0.999. The correlation coefficient of the reported and the calculated the maximum flame height by means of burner width and power was 0.999. The values calculated by the proposed equations were in good agreement with the literature data.

Characteristics of the Air Heat Exchanger for the Improvement of the Heat Pump COP (열펌프 성능향상을 위한 공기 열교환기 특성)

  • 노정근;송현갑;박용규
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.151-157
    • /
    • 2002
  • 화석에너지에 대한 경제적 부담과 환경오염문제를 줄이기 위하여 열펌프의 성능계수향상을 위하여 냉온 공기열교환기(HEEVA)를 고안하였고, 이 열교환기의 열특성과 성능계수향상에 미치는 영향을 분석하기 위하여 냉.난방 실험을 수행하였다. HEEVA에 의한 찬 공기와 더운 공기의 온도변화, 전열량 및 냉온 공기열교환기 효율, 총열전달계수등을 측정분석하였고, 냉난방시 외기온에 따른 열펌프의 성능계수, 소비전력, 응축기.증발기 출구 공기토출 온도 변화를 측정 분석함으로서 다음과 같은 결과를 얻을 수 있었다. 1. 외기온이 -4~11$^{\circ}C$로 변할 때 열펌프의 난방과정에서 HEEVA 찬공기 입출구 온도차는 4.5$^{\circ}C$에서 9.$0^{\circ}C$로 증가하였으며, HEEVA에 의한 영향으로 2~6$^{\circ}C$상승된 공기가 증발기 입구로 유입되어 냉매증발을 촉진하였다. 2. 실온이 4~22$^{\circ}C$일 때 HEEVA 더운공기 입출구 온도차는 3$^{\circ}C$에서 7$^{\circ}C$로 증가하였으며, 응축기에 유입되는 공기온도를 3~8$^{\circ}C$낮게 함으로서 압축기 소모전력을 감소시켜 COP 상승 효과를 나타냈다. 3. 외기온과 실온변화에 따라 풍량 346m$^3$/hr의 찬 공기가 받은 열량과 풍량 747m$^3$/hr의 더운 공기가 준 열량간의 차는 50~150kcal/hr로 나타났으며, 더운 공기가 준열량과 찬 공기가 받은 열량의 비가 83~98% 이었으므로 HEEVA의 열 교환율은 91% 을 보였다. 4. 총합열전달계수는 이론값이 실험 값보다 1~3W/m$^2$K 크게 나타났으며, 이 결과는 두 값 사이에 10% 내.외의 편차로서 Nusselt수를 구하기 위한 Petukhov상관식의 자체오차 15%에 비해 크지 않은 오차범주에 속하며, 이론상의 총합열전달계수 유도식의 타당성을 입증한 것이라 하겠다. 5. HEEVA를 작동함으로서 난방시 COP가 HEEVA를 작동하지 않았을 경우보다 0.3~0.5 향상된 것으로 나타났다. 이것은 HEEVA가 겨울철 난방에 효율을 높일수 있는 것으로 판단된다.

  • PDF

일부 서울지역 대학교 급식 식단의 메뉴분석-직영급식 및 위탁급식 운영 형태별 비교

  • 김진아;박수정;이심열
    • Proceedings of the KSCN Conference
    • /
    • 2003.11a
    • /
    • pp.1083-1084
    • /
    • 2003
  • 사회생활 양식이 점차 복잡해지고 생활전반의 조직이 고도화됨에 따라 대규모 급식의 필요성이 점점 증가되고 있다. 그 동안 단체급식은 자체적으로 운영하는 경우가 많았으나, 최근 들어 위탁운영의 효율성에 대한 인식이 높아짐에 따라 위탁 운영률이 크게 높아지고 있다. 현재까지 대학급식에 관한 연구는 대학식당의 이용실태, 대학 식단의 만족도 평가, 대학급식 메뉴 관리 및 운영 등을 조사한 연구는 많았으나 운영형태에 따른 식단 분석 연구는 미흡한 실정이다. 이에 본 연구에는 서울 시내 일부 대학교의 구내에 있는 5개 식당 23가지 식단에 대하여 직영급식과 위탁급식으로 나누어 학생들에게 제공되는 메뉴를 영양가면과 다양성 면에서 평가하고, 제공된 메뉴를 학생들이 실제 섭취하는 실태를 조사하여 섭취한 식단의 영양가와 음식의 종류를 분석하였다. 본 조사에서 이용한 식단은 총 23가지였고, 그 중에서 직영급식 13가지, 위탁급식 10가지였다. 제공된 상용식단형태는 직영급식은$\ulcorner$밥+국+반찬2+김치1$\lrcorner$, 위탁급식은 $\ulcorner$한그릇+국+반찬1+김치1$\lrcorner$이었으며, 우리나라 전통의 기본패턴을 갖추고 있었다. 제공된 식단 중 한끼 영양소 함량을 평가해본 결과 여자의 경우 1/3 영양권장량을 제공하였으나, 남자의 경우는 부족하였다. 제공되는 식단의 음식군별 제공열량을 살펴보면 밥은 평균 399㎉, 한그릇음식은 425㎉로 한 그릇음식의 경우가 높은 열량을 제공하고 있었다. 반찬의 경우 1가지로부터 얻는 열량은 평균 107㎉였으며 김치의 경우는 9.84 ㎉였다. 직영급식과 위탁급식으로 나누어 살펴보면 한 그릇음식, 반찬, 김치의 제공열량이 위탁급식에서 약간 높은 경향을 보였다. 대상자의 음식의 평균 가짓수는 직영 5.5가지, 위탁 4.3가지였으며, 음식 및 반찬 가짓수가 증가할수록 섭취열량이 증가하였다. 대상자들의 섭취한 식단의 한끼당 섭취한 영양소 함량은 직영급식 524㎉, 위탁급식 494㎉였고, 단백질, 지질, 인, 철, 비타민A, 나이아신 등이 유의적으로 직영급식에서 높았다(p<0.001) 섭취한 식단의 영양소 함량은 인과 비타민C를 제외한 모든 영양소에서 권장량에 미달되었다. 섭취한 식단의 영양소적정섭취비는 대부분 0.4-0.9의 값을 보였고, 평균적정섭취비도 직영, 위탁 모두 0.68로 낮은 값을 보였다. 영양소 밀도의 경우 절대적 섭취에서 직영급식이 대부분의 영양소를 많이 섭취하고 있는 것과는 달리 위탁급식에서 철분의 밀도가 유의적으로 높았다(p<0.01). 총 대상자들이 식단에서 섭취한 열량을 살펴보면, 주식류의 경우 밥은 298㎉, 한 그릇음식은 386㎉로 한 그릇음식이 많은 열량을 제공하고 있었다. 반찬의 경우는 1가지로부터 얻는 열량은 78㎉, 김치는 8㎉였다. 이상의 결과로 볼 때, 제공량은 직영급식에서 많았으나 영양밀도 면에서는 큰 차이가 없는 것으로 보아 위탁급식의 제공량을 늘린다면 급식운영형태별 두 식단의 질적 차이가 크게 줄어들 것으로 보인다. 그러나 두 급식 형태 모두 제공식단의 영양소 함량은 다른 지역이나 연령에 비해 부족한 것으로 나타나 아침 결식 및 불규칙한 식사 등 영양상태가 좋지 못한 대학생들에게 교내 식당에서 질 높은 식사를 제공해야 할 것이다. 또한 식단 작성 시 학생들의 메뉴 기호도를 충분히 반영시키고 다양한 메뉴를 제공하는데 한계가 있다면 주.부식 외에 다양한 후식제공을 통하여 학교 급식에 대한 질을 향상시키는 노력을 해야 할 것이다.

  • PDF

고온 초전도선재의 Quench 특성 평가에 관한 연구

  • Gang, Hyeong-Gu;Lee, Eung-Ro;Go, Tae-Guk
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.308-310
    • /
    • 2000
  • 일반적으로 Bi계 고온초전도선재(HTS Tape)는 저온초전도선재(LTS Tape)에 비해서 비열이 수백 배 이상 크므로 열적으로 상당히 안정한 성격을 가진다. 그러므로 이러한 HTS Tape를 TQ(Thermal Quench)시켜주는 일은 매우 어렵게 되는데, 일반적으로 HTS Tape를 이용한 초전도응용 분야에서 TQ를 이용한 스위칭 동작이 매우 중요하므로, 응응에 앞서 이에 관한 연구가 반드시 이루어져야 할 것이다. 본 연구에서는 Bi-2223 Short Sample의 TQ 특성을 실험하여 온도특성과 전압특성 등을 비교하였으며, 또한 이론적으로 HTS Tape를 TQ시켜주기 위한 열량과 실제 실험에서 사용된 열량의 값을 비교하였다.

  • PDF