• Title/Summary/Keyword: 연속벽

Search Result 116, Processing Time 0.024 seconds

Approximate Analysis of Shear Wall-Frame Structure For Seismic Design (전단벽-골조 시스템의 내진설계를 위한 근사해석법)

  • Yoo, Suk-Hyung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.2
    • /
    • pp.99-106
    • /
    • 2019
  • A wall-frame structure resists horizontal load by the interaction between the flexural mode of the shear wall and the shear mode of the frame, which implies that the frame deflects only by reverse bending of the columns and girders, and that the columns are axially rigid. However, as the height of frame increases the shear mode of frame changes to flexural mode, which is due to the extension and shortening of the columns. An approximate hand method for estimating horizontal deflection and member forces in high-rise shear wall-frame structures subjected to horizontal loading is presented. The method is developed from the continuous medium theory for coupled walls and expressed in non-dimensional structural parameters. It accounts for bending deformations in all individual members as well as axial deformations in the columns. The deformations calculated from the presented approximate method and matrix analysis by computer program are compared. The presented approximate method is more accurate for the taller structures.

Shear Resistance Performance of Vertical Construction Joints in Slurry Walls Using Concrete Shear Keys (콘크리트 전단키에 의한 지하연속벽 수직시공이음부의 전단저항 성능)

  • Lee, Jeong-Young;Kim, Seung-Weon;Kim, Doo-Kie
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.399-400
    • /
    • 2023
  • Current building structural standards require the shear strength and rigidity in the design of vertical construction joints in a slurry wall. This paper proposes a shear key resistance method for shear connection of vertical construction joints, and compares its structural performance with the currently prevalent method of shear friction rebar. The study found the structural performance of the shear key resistance method was significantly better than that of the shear friction rebar method.

  • PDF

Construction Method for Forming Concrete Shear Keys at Vertical Construction Joints of Slurry Walls (지하연속벽 수직시공이음부에 콘크리트 전단키를 형성하는 시공기술)

  • Lee, Jeong-Young;Kim, Seung-Weon;Kim, Doo-Kie
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.401-402
    • /
    • 2023
  • The shear connection of the vertical construction joint of a slurry wall by the concrete shear key has excellent structural performance and is economical and eco-friendly. However, technology for forming concrete shear keys in the underground is still underdeveloped. This paper proposes the development of the construction technology required to form a concrete shear key at the vertical construction joint of the slurry wall.

  • PDF

Engineering Properties of CB Cut-off Walls Mixed with GGBS (고로슬래그 미분말을 혼합한 CB 차수벽의 공학적 특성)

  • Kim, Taeyeon;Lee, Bongjik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.23 no.5
    • /
    • pp.33-39
    • /
    • 2022
  • For a slag-cement-bentonite (slag-CB) cut-off wall, GGBS replaces a part of the cement mixed to build a CB cut-off wall, which is used to block the flow and leakage of pollutants or groundwater; prevent seawater infiltration; and repair or reinforcement an aged embankments. Slag-CB cut-off walls are used in various applications in different fields where groundwater control is required due to its excellent characteristics. Such properties include high strength, low permeability, high durability and chemical resistance. However, despite these advantages, slag-CB cut-off walls are not extensively studied in Korea and thus are not applied in many cases. Particularly, GGBS, which replaces cement in a mixture, has different properties depending on its country of production. Consequently, it is necessary to perform various studies on slag-CB cut-off walls that use GGBS produced in Korea in order to increase its usability. This study has evaluated the bleeding rate, setting time, strength, and permeability in relation to the cement replacement rate of GGBS produced in Korea for slag-CB cut-off walls, with the aim to increase its usability. The evaluation found that slag-CB cut-off walls, made of a mixture containing GGBS produced in Korea, have a lower bleeding rate and permeability, and higher strengththan CB cut-off walls. It was also analyzed that such improved performance is more effective with a higher cement replacement rate of GGBS.

Repair of Left Ventricular Free Wall Rupture after Acute Myocardial Infarction: Application of Pericardial Patch Covering and Fibrin Glue Compression A case report (급성심근경색 후 발생한 좌심실벽 파열에서 소심낭과 Fibrin Glue 압박을 이용한 치험 - 1예 보고 -)

  • 김상익;금동윤;원경준;오상준
    • Journal of Chest Surgery
    • /
    • v.36 no.5
    • /
    • pp.363-366
    • /
    • 2003
  • Background: Left ventricular rupture after acute myocardial infarction is a serious complication with high mortality. Emergency operation is usually the only available treatment. A 76-year-old female with persistent chest pain and syncopal attacks was admitted. Transthoracic echocardiography showed the pericardial effusion and generalized hypokinesia of the inferolateral wall of left ventricle. Coronary angiography revealed a total occlusion of the first diagonal branch. After percutaneous transluminal coronary angioplasty with coronary stent and insertion of intraaortic balloon pump, emergency operation was performed. Under cardiopulmonary bypass and cardiac arrest with cold blood cardioplegia, coronary artery bypass graft with saphenous vein, pericardial patch covering on the rupture area with 6-0 polypropylene running sutures, and fibrin glue compression under the patch were performed. We present a case of left ventricular (free wall) rupture after acute myocardial infarction.

Thermal Conductivity of Single-Walled Carbon Nanotube by Using Memory Function (메모리함수에 의한 단일 벽 탄소 나노튜브의 열전도도)

  • Park, Jung-Il;Cheong, Hai-Du
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.3
    • /
    • pp.144-149
    • /
    • 2013
  • We use Memory function to examine the thermal conductivity as a function of the temperature in single-walled carbon nanotube (SWNT). We determine the Umklapp, normal and SWNT-substrate phonon scattering rate from the computed inverse spin relaxation time. Thermal conductivity increased as the diameter increased when we assumed that the zigzag (10,0) transition was a more dominant phonon scattering than the (9,0) transition.

The Fluid Loss and Sealing Mechanisms in Slurry Trench Condition (I) : A Large Scale Test and Design Procedure (Slurry wall 공법에서 안정액의 역할 (I) : 대형모형실험과 설계절차)

  • Kim, Hak-Moon
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.4
    • /
    • pp.239-248
    • /
    • 2002
  • Bentonite slurries in a slurry wall construction must fulfill a stabilizing function by forming impermeable membrane (surface cake and penetrated cake) on the excavated soil faces. Thus problems are occurring in practice for the construction of diaphram walls and cut-off walls with a low permeability for wastes disposal areas in some deep excavations or different grounds. In this paper, the fundamental mechanics of fluid loss and filter cake formation in various soil beds are investigated using large scale laboratory apparatus. The sealing efficiency of filter cake from the large scale tests and the significance of fluid loss in a slurry trench are utilized for practical situation as a recommended design procedure.

Inspection of Underground Slurry Wall for LNG Storage Tank (LNG 저장 탱크 지중연속벽 품질시험)

  • Kim, Young-H.;Jo, Churl-Hyun;Lim, Seong-Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.2
    • /
    • pp.107-115
    • /
    • 2003
  • Nondestructive testing was carried out in order to evaluate the structural integrity and construction quality of the slurry wall of the underground LNG storage tank. 9 test points were selected, and the wall thickness, rebar spacing, and compressive strength of the slurry wall were evaluated by stress wave impact-resonance method, GPR, sonic velocity, and rebound testing, respectively. As results, the wall thickness, rebar sparing and estimated compressive strength satisfy the design criteria.

Multi-scale Simulation on the Mechanical Behavior of Multi-walled Carbon Nanotubes (다중벽 탄소나노튜브의 역학적 거동에 관한 멀티스케일 전산모사)

  • Park, Jong-Youn;Cho, Young-Sam;Kim, Sung-Youb;Im, Se-Young
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.400-403
    • /
    • 2004
  • We present a coarse-graining model to describe the mechanical behaviors of multi-walled carbon nanotubes. To find the atomic configuration in membrane-like nanostructure i.e. carbon nanotube, we employ interpolation functions and the associated element-variables that are defined in the subdivided region. Tersoff-Brenner potential is adopted for interaction of bonded atoms and also van der Waals force for non-bonded interaction. Moreover, we simulate the coarse-graining multi-walled carbon nanotubes with defects and its result is compared with that of perfect multi-walled carbon nanotubes.

  • PDF

Top-Down Method of Deep Basement Construction in Urban Area : a Comparison of Numerical Analysis and Field observation Data (도심지 지하굴착에 적용된 Top-Down 공법의 수치해석과 실측비교)

  • 김학문
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1991.10a
    • /
    • pp.312-331
    • /
    • 1991
  • Top-down Method of basement construction technique has been applied for building of the deep basement car park the close proximity of priceless historic buildings in LONDON. Numerical analysis for the prediction of ground movement of the surrounding buildings was performed in order to compare the field data at the various stages of excavation and support. The predicted results from the elasto-plastic analytical method were compared with the observed data and the agreement is very satisfactory. It may be concluded that the system of diaphragm wall supported by the permanent base slabs (Top-Down Method) was proved to be the most effective technique in terms of reducing any critical damage to the surrounding buildings.

  • PDF