• Title/Summary/Keyword: 연소배가스

Search Result 86, Processing Time 0.03 seconds

Combustive Characteristic and Toxic Gases Generation of Interior Materials -The focus for resist-carpet, resist-after-tretment plywood, sofa leather- (내장재의 연소 및 독성가스 발생 특성 -방염 카페트, 방염 후처리 합판, 쇼파 내자를 중심으로-)

  • 김일수;류경옥
    • Fire Science and Engineering
    • /
    • v.12 no.2
    • /
    • pp.43-59
    • /
    • 1998
  • It was studied a compared estimation of the fire risk of the three kinds of the interior materials, such as a resist carpet, a resist-after-treatment plywood and sofa leather. Toxic gases, CO, CO2, NOx, SO2, HCN, HCI were detected during the combustion of the samples. A resist-carpet was more combustible than the resist-after-treatment plywood and sofa leather in the combustion characteristics and has a blow-up-combustion of combustion in all the samples. The generation of CO reached the lethal doses in minute after the combustion was begun. NOx and So2 were detected not more than each of the lethal doses, while HCN was detected in the carpet 20.6 times than the sofa leather, and 4.6 times than the resist-after-treatment plywood. HCI was detected in the carpet 4.48 times than the sofa leather and 2.47 times than the resist-after-treatment plywood. It is conclusion that the carpet was the highest in the fire risk among the three kinds of the interior materials.

  • PDF

Biological Removal of Nitrogen Oxides from Combustion Flue Gases (연소배가스 중 질소산화물(NOx) 제거를 위한 생물학적 기술)

  • Lee, Ki-Say
    • Applied Chemistry for Engineering
    • /
    • v.21 no.3
    • /
    • pp.243-251
    • /
    • 2010
  • Nitrogen oxides (NOx) in combustion flue gas are currently mitigated by chemical processes such as catalytic reduction, absorption and adsorption. However, development of environmentally sustainable biological processes is necessary in the near future. In this paper, the up-to-dated R&D trend of biological methodologies regarding NOx removal was reviewed, and their advantages and disadvantages were discussed. The principles and applications of bacterial system including nitrification and denitrification and photosynthetic microalgae system were compared. In order to enhance biological treatment rate and performance, the insoluble nitric oxide (NO) should be first absorbed using a proper solubilization agent, and then microbial degradation or fixation is to be followed. The use of microalgal system has a good prospect because it can fix $CO_2$ and NOx simultaneously and requires no additional carbon for energy source.

Application of high temperature air combustion for improvement of thermal efficiency of oxide furnace (산화로의 열효율 향상을 위한 고온공기 연소 적용연구)

  • 이현찬;유현석;이중성
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2002.11a
    • /
    • pp.3-7
    • /
    • 2002
  • 보일러 분야에 비해 요ㆍ로 분야는 로내 온도분포, 피가열물의 물리적 특성, 고열에 의한 열처리 등으로 인해 상대적으로 공정개선, 폐열회수율 등이 떨어지는 설비이다. 이에 일본, 미국, 유럽 등 선진국에서는 90년 초부터 연소배가스의 폐열을 적극적으로 회수하여 연소시키는 고온공기연소기술을 개발하여 상용화하였다.(중략)

  • PDF

A Study on the Combustion Flow Characteristics of a Exhaust Gas Recirculation Burner with the Change of Outlet Opening Position (배기가스 재순환 버너에서 연소가스 출구 위치에 따른 연소 유동 특성에 관한 연구)

  • Ha, Ji-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.8
    • /
    • pp.8-13
    • /
    • 2018
  • Nitrogen oxides (NOx) have recently been very influential in the generation of ultrafine dust, which is of great social interest in terms of improving the atmospheric environment. Nitrogen oxides are generated mainly by the reaction of nitrogen and oxygen in air in a combustion gas atmosphere of high temperature in a combustion apparatus such as thermal power generation. Recently, research has been conducted on the combustion that recirculates the exhaust gas to the cylindrical burner by using a piping using a Coanda nozzle. In this study, three types of burners were carried out through computational fluid analysis. Case 1 burner with the outlet of the combustion gas to the right, Case 2 burner with both sides as gas exit, Case 3 burner with left side gas exit. The pressure, flow, temperature, combustion reaction rate and distribution characteristics of nitrogen oxides were compared and analyzed. The combustion reaction occurred in Case 1 and Case 2 burner in the right direction with combustion gas recirculation inlet and Case 3 burner in the vicinity of mixed gas inlet. The temperature at the outlet was about $100^{\circ}C$ lower than that of the other burners as the Case 2 burner was exhausted to both sides. The NOx concentration of Case 1 burner at the exit was about 20 times larger than that of the other burners. From the present study, it could be seen that it is effective for the NOx reduction to exhaust the exhaust gas to both side gas exits or to exhaust the exhaust gas to the opposite direction of inlet of recirculation gas.

Sensing Characteristics of $SnO_{2}$ type CO sensors for combustion exhaust gases monitoring (연소배가스 모니터링을 위한 $SnO_{2}$계 CO센서의 검지특성)

  • Kim, I.J.;Han, S.D.;Lim, H.J.;Son, Y.M.
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.5
    • /
    • pp.369-375
    • /
    • 1997
  • $V_{2}O_{5}/ThO_{2}/Pd$-doped $SnO_{2}$ sensor has a good selectivity and stability to CO at high sensor temperature of about $500^{\circ}C$, and shows rapid response. In particular, many kinds of interference gases, such as $NO_{x}$, $C_{3}H_{8}$, $CH_{4}$ and $SO_{2}$ have been found to give only a slight influence on the sensor selectivity to CO gas sensitivity by doped $V_{2}O_{5}$ (3.0 wt.%). For the sensor we used well-known thick film technological route with $V_{2}O_{5}$(3.0 wt.%), Pd(1.0 wt.%) and $ThO_{2}$(l.5 wt.%) as catalytic materials. In the case of mixed $NO_{x}$-CO gases, as combustion exhaust gas, only CO detection by $SnO_{2}$ type semiconductor sensor is generally very difficult because of $NO_{x}$ interference. The developed sensors can use to measure the exhausting gas of the automobile or the boiler for the Air-to-Fuel ratio control.

  • PDF

Development and Test of Gas Turbine Combustor for Ground Vehicle PPU(Primary Power Unit) (지상용 가스터빈 주동력장치(PPU) 연소기의 개발과 시험평가)

  • Lee, Dong-Hun;Lee, Kang-Yeop;Chen, Seung-Bae;Yang, Soo-Suk;Ko, Young-Sung;Choi, Seong-Man
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.8
    • /
    • pp.111-121
    • /
    • 2005
  • A 100kW class gas turbine combustor was developed and tested for PPU(Primary Power Unit) of ground vehicle. The combustor which employed annular-reverse type and pressure swirl atomizer was designed through 1-D analysis, 3-D thermal flow analysis and combustor performance was experimentally investigated on the combustor test rig. The test result was satisfactory. The developed combustor was also tested for environmental and endurance specification under engine adopted conditions and the application of a state-of-the-art gas turbine combustor to ground vehicle PPU turned out to be successful.

A Study on the Separation of $CO_2$from Flue Gas by Chemical Absorption (화학흡수법에 의한 연소폐가스 중 지구온난화 가스 $CO_2$분리에 관한 연구)

  • 안성우;김영국;송호철;박진원
    • Journal of Energy Engineering
    • /
    • v.6 no.2
    • /
    • pp.203-211
    • /
    • 1997
  • This study is on the separation of Global warming effect gas, CO$_2$by chemical absorption from mixture of CO$_2$-N$_2$which was modeled after flue gas of fire power plant. Investigation of optimum condition for absorbent was carried out by using sparged vessel apparatus. Through packed tower experiments, applicabilities of two absorption models were tested by comparing experimental results with theoretical values. Absorbent used in the experiments was Monoethanolamine (MEA) and gas mixture was made in the mole composition of 15% CO$_2$and 85% N$_2$. Through estimations of CO$_2$loading and CO$_2$removal efficiency, optimum concentration of absorbent was found in the range of 4-5 M. To find a rate of absorption, an enhancement factor was introduced. Values of rate of absorption were calculated by Film model and Higbie model, respectively. Higbie model showed good agreement with experimental results. Therefore, this models is considered to be applicable to the CO$_2$separation process for flue gas from fire power plant.

  • PDF

Separation of Carbon Dioxide Using Pelletized Zeolite Adsorbent with Amine Impregration (아민 함침 성형 제올라이트 흡착제를 이용한 이산화탄소 분리)

  • Hong, Mi So;Pankaj, Sharma;Jung, Yun Ho;Park, Sung Youl;Park, So Jin;Baek, Il Hyun
    • Korean Chemical Engineering Research
    • /
    • v.50 no.2
    • /
    • pp.244-250
    • /
    • 2012
  • In order to separate of carbon dioxide in the combustion exhaust gas, monoethanolamine (MEA) and piperazine (PZ) impregnated zeolite 13X adsorbents were used. A series of adsorbents were synthesized by impregnating 30, 50 and 70 wt% of MEA and PZ respectively on zeolite 13X pellet. XRD, FT-IR and BET were used to characterize the properties of impregnated pelletized zeolite 13X absorbents. In order to investigate the separation characteristics of carbon dioxide, zeolite pellet, MEA impregnated zeolite and PZ impregnated zeolite pellet were investigated at 25, 50 and $75^{\circ}C$. Amine impregnated pelletized zeolite absorbent has shown that adsorption decreases with increasing temperature. Finally, the carbon dioxide adsorption capacity when emission temperature of the combustion exhaust gas, PZ impregnated zeolite pellet was 1.8 times than zeolite pellet as well as 20 times than MEA impregnated zeolite pellet.

A Study of Cold Flow Characteristics of a Flue Gas Recirculation Burner using Coanda Nozzles (코안다 노즐을 이용한 배기가스 재순환 버너의 냉간 유동 특성에 관한 연구)

  • Ha, Ji Soo;Park, Chan Hyuk;Shim, Sung Hun;Jung, Sang Hyun
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.152-158
    • /
    • 2016
  • Nitrogen oxide is generated by the chemical reaction of oxygen and nitrogen in higher temperature environment of combustion facilities. The NOx reduction equipment is generally used in the power plant or incineration plant and it causes enormous cost for the construction and maintenance. The flue gas recirculation method is commonly adopted for the reduction of NOx formation in the combustion facilities. In the present study, the computational fluid dynamic analysis was accomplished to elucidated the cold flow characteristics in the flue gas recirculation burner with coanda nozzles in the flue gas recirculation pipe. The inlet and outlet of flue gas recirculation pipes are directed toward the tangential direction of circular burner not toward the center of burner. The swirling flow is formed in the burner and it causes the reverse flow in the burner. The ratio of flue gas recirculation flow rate with the air flow rate was about 2.5 for the case with the coanda nozzle gap, 0.5mm and it was 1.5 for the case with the gap, 1.0mm. With the same coanda nozzle gap, the flue gas recirculation flow rate ratio had a little increase when the air flow rate changes from 1.1 to 2.2 times of ideal air flow rate.

Toxicity Evaluation of the Combustion Products from Synthetic Wood as Internal Finish (건축물 내부 마감재인 합성목재별 연소가스 독성평가)

  • Kim, Jong-Buk;Lee, Si-Young
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.7-18
    • /
    • 2016
  • This study evaluated the toxicity of the burning gas from the synthetic wood products used in housings or warehouses. The combustion products of five materials, viz. impregnated laminated board, MDF, Douglas fir plywood, core plywood, and Lauan retardant, were analyzed using SEM, FTIR and a Cone Calorimeter. For the Lauan retardant, 256,965 ppm of carbon dioxide ($CO_2$) and 1,475 ppm of sulfur dioxide ($SO_2$) were measured, which are 2.5 times and 3.6 times as high as their lethal concentrations of 100,000 ppm and 400 ppm, respectively. For the impregnated laminated board, 1,569 ppm of nitrogen dioxide ($NO_2$) was measured, which is 6 times as high as its lethal concentration of 250 ppm. For MDF, 795 ppm of ammonia ($NH_3$) was measured, which is higher than its lethal concentration of 750 ppm. As a result, most internal-finishes generated toxic combustion products at levels higher than their lethal concentrations, which underlines the importance of the selection and manufacturing of internal-finish materials.