• Title/Summary/Keyword: 연소가스 농도

Search Result 354, Processing Time 0.029 seconds

Development of Direct DME Synthesis Process (DME 직접 합성공정 기술개발)

  • Mo, Yong-Gi;Cho, Won-Jun;Baek, Young-Soon
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.3
    • /
    • pp.41-45
    • /
    • 2010
  • The physical properties of DME(Dimethyl Ether) are very similar to LPG and well-mixed. As cetane number of DME is similar to diesel fuel that can replace diesel fuel and alternative energy. DME is a clean energy source that can be manufactured from various raw materials such as natural gas, CBM(Coal Bed Methane) and biomass. DME has no carbon-carbon bond in its molecular structure and its combustion essentially generates no soot as well as no SOx. The development of DME process in KOGAS have 4 section. First, syngas section can be manufactured various syngas ratio. This completes the tri-reforming process for the synthesis gas ratio of approximately 4.0 to 1.0 range can be adjusted. Second, $CO_2$ is removed from the $CO_2$ removal section of about 92~99%, so the maximum concentration of $CO_2$ entering the DME synthesis reactor should not exceed 8%. Third, in the DME synthesis section, if the temperature of DME reactor increases, the activity of DME catalyst increased. but for the long-term activity is desirable to maintain the proper temperature. Finally, the purity of DME in the DME purification section is over 99.6%.

Effect of fuel component on nitrous oxide emission characteristics in diesel engine (디젤엔진에 있어서 연료의 성분이 아산화질소 배출에 미치는 영향)

  • Yoo, Dong-Hoon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.9
    • /
    • pp.1045-1050
    • /
    • 2014
  • $N_2O$(Nitrous Oxide) is known as the third major GHG(Green House Gas) following $CO_2$(Carbon Oxide) and $CH_4$(Methane). The GWP(Global Warming Potential) factor of $N_2O$ is 310 times as large as that of $CO_2$ because $N_2O$ in the atmosphere is very stable, and it becomes a source of secondary contamination after photo-degradation in the stratosphere. Investigation on the cause of the $N_2O$ formation have been continuously reported by several researchers on power sources with continuous combustion form, such as a boiler. However, in the diesel engine, research on $N_2O$ generation which has effected from fuel components has not been conducted. Therefore, in this research, author has investigated about $N_2O$ emission rates which was changed by nitrogen and sulfur concentration in fuel on the diesel engine. The test engine was a 4-stroke direct injection diesel engine with maximum output of 12 kW at 2600rpm, and operating condition of that was set up at a 75% load. Nitrogen and sulfur concentrations in fuel were raised by using six additives : nitrogen additives were Pyridine, Indole, Quinoline, Pyrrol and Propionitrile and sulfur additive was Di-tert-butyl-disulfide. In conclusion, diesel fuels containing nitrogen elements less than 0.5% did not affect $N_2O$ emissions in the all concentrations and kinds of the additive agent in the fuel. However, increasing of the sulfur additive in fuel increased $N_2O$ emission in exhaust gas.

A Numerical Study for Fire Safety Evaluation of the Multi-story Residential Buildings -The Effects of the Openings of Stairwell on Fire Characteristics- (다세대주택의 화재안전평가에 대한 수치해석 연구 -계단실 개구부의 개폐가 화재특성에 미치는 영향-)

  • Jeon, Heung-Kyun;Choi, Young-Sang;Choo, Hong-Lok
    • Fire Science and Engineering
    • /
    • v.21 no.3
    • /
    • pp.15-23
    • /
    • 2007
  • In the events of a fire in the residential building, highly flammable polyurethane foam sofa produce toxic smokes. In this type of fire, the residents of the building can be gotten into the difficulties of evacuating from the fire places or may be to death due to a lot of hot toxic gases. In this study, CFD simulations were carried out to study the effects of the openings of stairwell on the fire characteristics of fire room and stairwell. Also, analysis of fire hazard based on the tenability limits of fire and FED(fractional effective dose) was performed to evaluate the life safety of the residents of the building. In the fire room, maximum temperature was about $290^{\circ}C$, maximum CO concentration was about 4,740 ppm, and the time to incapacitation of residents in fire room was about t=144 s. In the stairwell, temperature and CO concentration in the condition of openings to be open were even lower than those in it to be closed. Time to the tenability limit with respect to smoke visibility in the stairwell with openings, which was open, was shorter than that of it without openings to be open. It has been shown from this study that opening the stairwell openings is able to decrease the fire hazards to the life safety in the multi-story residential building fire.

Levels of Persistent Organic Pollutants in Waste Paper and Waste Lumber and Evaluation of their Sources (폐지와 폐목재에서의 잔류성 유기오염물질의 농도 및 배출원 추정)

  • Hwang, In-Kyu;Lee, In-Seok;Oh, Kwang-Joong;Kim, Ji-Won;Park, Hung-Suck;Oh, Jeong-Eun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.9
    • /
    • pp.870-878
    • /
    • 2010
  • We investigated the concentration and the sources of ubiquitous persistent organic pollutants [i.e., 17 toxic polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), 12 coplanar polychlorinated biphenyls (Co-PCBs), and 16 priority polycyclic aromatic hydrocarbons (PAHs)] in waste papers and lumbers from industrial complexes. The total concentrations in waste papers and lumbers ranged from 9.69~176.77 pg/g-dry and 0.14~0.25 pg/g-dry for 17 PCDD/Fs, 109.95~4097.25 pg/g-dry and 28.23~59.88 pg/g-dry for 12 Co-PCBs and 9.30~52.18 ng/g-dry and 0.82~1.82 ng/g-dry for 16 PAHs respectively. Generally, the concentration of these pollutants in waste papers was higher than those in waste lumbers. OCDD was dominant in waste papers and lumbers and the PCDD/F patterns of these samples were similar with that of stack gas. The distribution patterns of Co-PCBs in wastes were related with commercial PCB products, indicating the effect of commercial PCB products on ubiquitous environment. The diagnostic ratios of several PAH compounds in waste paper showed that they were related with pyrogenic sources.

퇴적 마그네슘의 승온속도와 열분해특성

  • Han, U-Seop;Lee, Su-Hui
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.116-116
    • /
    • 2013
  • 마그네슘은 스마트폰, 전자기기 케이스, 내화벽돌과 아크용접봉 제조시의 첨가물 등으로 사용되고 있는데, 최근에는 재활용을 위한 마그네슘 용해로를 취급하거나 가공하는 사업장이 증가하고 있어 사고위험성이 높아지고 있다. 금속분을 취급하는 사업장에서의 금속분진은 저장이나 축적 등과 같이 주로 퇴적물로서 존재한다. 퇴적분진의 발화온도는 퇴적물 형상과 두께, 입경, 분위기 가스의 유속, 산소농도, 부유분진의 농도, 퇴적밀도, 수분 등의 많은 영향인자가 관여하기 때문에 이론적 예측이 힘들고 실험적인 측정에 의존할 수 밖에 없는 것이 현실이다. 본 연구에서는 연소성이 높고 화재폭발사고사례가 많은 마그네슘(Mg) 분진을 사용하여 승온속도 변화에 따른 열분해특성을 조사하였다. 퇴적분진의 열적특성을 조사하기 위하여 METTLER TOLEDO의 TGA/DSC1를 사용하였으며, Mg 시료의 평균입경은 38, $142{\mu}m$이다. 입경 $38{\mu}m$의 Mg 시료의 열중량분석 결과, 중량증가는 $400{\sim}500^{\circ}C$의 범위에서 시작되며 $550^{\circ}C$에서 급격하게 중량이 증가하고 있으며, 증량증가개시온도(Temperature of weight gain)는 $460^{\circ}C$에서 시작하여 $900{\sim}950^{\circ}C$ 범위에서 중량 증가 포화값에 도달하였다. 입경 $142{\mu}m$의 Mg에 대하여 공기중 승온속도를 5, 10, $20^{\circ}C/min$으로 변화시키면서 실온에서 $900^{\circ}C$까지 가열 시키는 경우의 시료의 중량 변화에 따른 열분해 특성은 승온속도가 증가할수록 2단계의 S자 곡선은 완만하게 상승을 나타내며 중량증가개시온도가 높아지는 경향을 보이고 있다. 중량증가개시온도가 승온속도에 따라 변화하는 결과를 나타내고는 있지만, 시료량의 증가에 따른 영향을 열중량분석 실험방법의 제약으로 인하여 확인할 수 가 없었다. 그러나 만일 시료량이 크게 증가하는 경우에는 동일한 승온조건에서 중량증가 개시온도는 낮아질 가능성이 있다. 중량증가는 시료의 산화반응에 의한 것이므로 시료량의 증가는 시료 내부에의 열의 축적을 용이하게 하여 보다 낮은 온도에서도 산화반응이 충분히 일어나는 조건이 형성되기 때문이다. 승온속도가 증가할수록 산화 반응한 괴상형태의 연소입자가 크게 증가하고 있는 것을 알 수 있다. 승온속도에 따른 중량개시온도 곡선을 보면 [그림 24]와 같으며 승온속도 5, 10, $20^{\circ}C/min$의 증가에 따라 중량개시온도는 각각 490, 510, $530^{\circ}C$가 얻어졌으며 승온속도의 증가에 따라 중량개시온도가 증가하는 경향을 보이고 있다.

  • PDF

Performance and Emission Characteristics of a CNG Engine Under Different Natural Gas Compositions (천연가스 조성 변화에 따른 CNG 엔진 성능 및 배기가스 특성)

  • Ha, Young-Cheol;Lee, Seong-Min;Kim, Bong-Gyu;Lee, Chang-Jun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.7
    • /
    • pp.749-755
    • /
    • 2011
  • The performance and emission characteristics of a CNG (compressed natural gas) engine were experimentally investigated under different natural gas compositions. The engine specifications were as follows: 6606 cc, turbo, lean-burn-type; its ignition timing was fixed for the fuel gas with a HHV (higher heating value) of 10454 kcal/$Nm^3$. The experimental results showed that when the HHV of the fuel gas was changed from 10454 kcal/$Nm^3$ to 9811 kcal/$Nm^3$ and 9523 kcal/$Nm^3$, the average power reductions were 3.2 % and 3.4 % (1.5 % and 2.1 %, respectively, with A/F control switched off), respectively, and the average thermal-efficiency reductions were 1.1 % and 1.5 % (1.5 % and 2.1%, respectively, with A/F control switched off), respectively. The emissions of $CO_2$, CO, and $NO_x$ decreased as the HHV of the fuel gas was lowered. On the other hand, the emissions of THC (total hydrocarbon) were not consistent, and the extent of change in their emissions was small.

The Risk Assessment of Carbon Monoxide Poisoning by Gas Boiler Exhaust System and Development of Fundamental Preventive Technology (가스보일러 CO중독 위험성 예측 및 근원적 예방기술 개발)

  • Park, Chan Il;Yoo, Kee-Youn
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.3
    • /
    • pp.27-38
    • /
    • 2021
  • We devised the system to automatically shutdown the boiler and to fundamentally block the harmful gases, including carbon monoxide, into the indoor when the exhaust system swerves: (1) The discharge pressure of the exhaust gas decreases when the exhaust pipe is disconnected. The monitoring system of the exhaust pipe is implemented by measuring the output voltage of APS(Air Pressure Sensor) installed to control the amount of combustion air. (2) The operating software was modified so that when the system recognizes the fault condition of a flue pipe, the boiler control unit displays the fault status on the indoor regulator while shutting down the boiler. In accordance with the ventilation facility standards in the "Rules for Building Equipment Standards" by the Ministry of Land, Infrastructure and Transport, experiments were conducted to ventilate indoor air. When carbon monoxide leaked in worst-case scenario, it was possible to prevent poisoning accidents. However, since 2013, the number of indoor air exchange times has been mitigated from 0.7 to 0.5 times per hour. We observed the concentration exceeding TWA 30 ppm occasionally and thus recommend to reinforce this criterion. In conclusion, if the flue pipe fault detection and the indoor air ventilation system are introduced, carbon monoxide poisoning accidents are expected to decrease significantly. Also when the manufacturing and inspection steps, the correct installation and repair are supplemented with the user's attention in missing flue, it will be served to prevent human casualties from carbon monoxide poisoning.

Removal of Carbon Monoxide from Anthracite Flue Gas by Catalytic Oxidation (I) (촉매반응에 의한 연탄 연소가스로부터 일산화탄소의 제거 (제1보))

  • Chung Ki Ho;Lee, Won Kook
    • Journal of the Korean Chemical Society
    • /
    • v.20 no.5
    • /
    • pp.431-437
    • /
    • 1976
  • On the condition of adequate air supply, complete removal of carbon monoxide,occurred above $650^{\circ}C$. Using catalysts, the oxidation of carbon monoxide occurred at lower temperatures; on both $MnO_2 \;and\;30%\;MnO_2-70%\;CuO\;at\;250{\circ}C,\;on\;CuO\;at\;450{\circ}C,\;on\;50%\;MnO_2-50%\;CuO\;at\;200{\circ}C,\;and\;on\;70%\;MnO_2-30%\;CuO\;at\;180{\circ}C$. Manganese dioxide (p-type) showed higher activity than cupric oxide (n-type) and a catalyst consisting of 60% $MnO_2-40%$ CuO had the highest activity of all the $MnO_2$-CuO mixture. Over the range of transitional temperature, carbon monoxide removal efficiency decreased linearly with increasing inlet carbon monoxide concentration while temperature was fixed. Residence time of gases in the catalytic reactor, in the range of 0.9 to 1.8 seconds, gave no effect on carbon monoxide conversion.

  • PDF

Optimization for I-129 analytical method of radioactive waste sample using a high-temperature combustion tube furnace (고온연소로를 이용한 방사성 폐기물 내 I-129 정량 분석법 최적화 연구)

  • Chae-yeon, Lee;Jong-Myoung, Lim;Hyuncheol, Kim;Ji-Young, Park;Jin-Hong, Lee
    • Analytical Science and Technology
    • /
    • v.35 no.6
    • /
    • pp.256-266
    • /
    • 2022
  • It is important to determine the concentration of long-lived radionuclides (e.g., 129I) in nuclear waste to ensure safety when handling it. To analyze nuclides in a solid sample (e.g., concrete and soil), it is essential to effectively separate and purify the nuclides of interest in the sample. This study reports the comprehensive efforts made to validate the analytical procedure for 129I detection in solid samples, using a high-temperature combustion furnace. 129I volatilized from the sample collected in 0.01 M HNO3 solution with a reducing agent (e.g., NaHSO3) and was rapidly measured by ICP-MS. Analytical conditions, such as pyrolysis temperature and types of mobile phase gas, catalyst, and trapping solution, were optimized to obtain a high recovery rate of spiked 129I. Finally, the optimized method was applied for the simultaneous analysis of other volatile radionuclides, such as 3H and 14C. The performance test results for the optimized method confirmed that the LSC (for 3H and 14C) and ICP-MS (for 129I) measurements, with the separation of volatile nuclides using a high-temperature combustion furnace, were reliable.

Effects of Regeneration Parameters on Oxidation of Particulate in a Diesel Particulate Trap System (디젤 입자상물질 후처리 장치에서 입자상물질의 연소에 미치는 재생 인자의 영향)

  • Kim, J. U.;Cho, H.;Kim, H. U.;Park, D. S.;You, C.;Kim, E. S.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.2
    • /
    • pp.168-177
    • /
    • 1998
  • The effects of the regeneration parameters such as inlet gas temperature, space velocity, oxygen concentration of the exhaust gas, and initial particulate loading on the oxidation of the particulate inside ceramic cordierite filter have been investigated through an engine experiment. As the inlet gas temperature increases, the remarkable filter temperature occurs owing to the rapid combustion rate. Though the higher space velocity affirms the safe regeneration, it also requires much fuel consumption of the burner. For that reason, the space velocity should be compromised considering the fuel economy. The excessive accumulation of the particulate may cause undesirable regeneration temperatures inside filer even under the optimized regeneration condition. The inlet gas temperature should be selected to overcome the variation of the oxygen concentration which is inherent feature of the diesel engine. It is the most important factor in the regeneration control techniques.

  • PDF