Search Result 112, Processing Time 0.028 seconds

Experiments on Performance of Fan used in Pressure Differential System for Smoke Management (급기가압 제연시스템의 송풍기에 대한 실규모 성능평가 실험)

  • Kim, Jung-Yup
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.458-462
    • /
    • 2008
  • The fact that the major cases of life casualties are from smoke in the fire accidents and the expected steep increase of skyscrapers, huge spaces, multiplexes and huge scaled underground spaces demand establishment of efficient smoke countermeasure. The core technology for development of smoke management system is analysis tool of fan used in pressure differential system. The experiments on performance of sirroco-typed fan are carried out to evaluate the features of fan and present the experimental data for numerical analysis.

  • PDF

Numerical Analysis on Features of Airflow through Open Door in Pressure Differential System (급기가압 제연시스템의 방연풍속 형성특성에 대한 수치해석적 분석)

  • Kim, Jung-Yup;Rie, Dong-Ho;Kim, Ha-Young
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.463-468
    • /
    • 2008
  • The fact that the major cases of life casualties are from smoke in the fire accidents and the expected steep increase of skyscrapers, huge spaces, multiplexes and huge scaled underground spaces demand establishment of efficient smoke countermeasure. In pressure differential systems for smoke management, the speed of airflow through open door between accommodation and lobby should be maintained over 0.5m/s on the whole area of door to prevent smoke from infiltrate into evacuation root when the door is open for refuge. The numerical analysis on features of airflow through open door are carried out and the results are presented.

  • PDF

큰 개구부가 있는 지하공간의 화재와 제연에 관한 수치적 연구

  • Park, Oe-Chul;Ko, Kyung-Chan;Park, Jun
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2003.05a
    • /
    • pp.121-128
    • /
    • 2003
  • 화재가 발생했을 때 많은 사람이 연기에 질식하여 사망하는 피해가 거의 해마다 일어나고 있다. 특히 올해 2월18일 190여명이 사망한 대구 지하철 중앙로역 화재참사에서는 다량의 유독성 가스를 효과적으로 배출하지 못해 더 많은 사망자가 발생하였다. 당시 지하철역에는 화재가 발생하면 환기용 배기장치가 급기장치로 전환되는 급기방식의 제연설비가 설치되어 있었고, 시계 불량으로 피난 표지판과 유도등이 잘 보이지 않은 것으로 밝혀졌다.(중략)

  • PDF

Study of the Smoke Control Characteristics for Fire Near Jet Fans (Jet fan 근접 화재 발생 시 제연 특성 연구)

  • Kim, Jong-Yoon;Seo, Tae-Beom;Lim, Kyung-Bum;Yoo, Ji-Oh;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.21 no.1 s.65
    • /
    • pp.82-89
    • /
    • 2007
  • In this research, we conducted a PIV-visualization experiment to smoke control from fires by using a neighboring Jet fan at minimum distance. We also compared our experiment results with FDS numerical analysis ones. As a result of quantitative data analysis of smoke control modes against fires in tunnel, we concluded that a neighboring Jet fan should be placed at least 25 m away from its fire source in order to produce satisfactory smoke control results. Jet fan showed the best smoke-controlling performance, if placed 50 m away from its fire source. It tended to show an overspeed around the center of tunnel when it is placed more than 75 away from its fire source.

A Numerical Simulation of Smoke Control in Daegu Subway Stations II. Air Flowrate of Extraction System (대구 지하철역 제연의 문제점과 대책 II. 배기방식 제연설비의 풍량)

    • Fire Science and Engineering
    • /
    • v.17 no.4
    • /
    • pp.105-110
    • /
    • 2003
  • In Part II, the temperature and smoke particle distributions of the extraction system, which yielded the best smoke removal performance among the three smoke control systems in Part I, for extraction flowrates of 0.6∼2.4 ㎥/s and two fire sizes of 200 ㎾ and 2 ㎿ were presented. The same numerical method was utilized to the same computational domain and configurations as Part I. It was shown that the extraction flowrate affects the smoke control performance significantly, and that a similar trend in improving the smoke removal performance with the increasing extraction flowrate between the two fire sizes. An extraction flowrate of 2.4 ㎥/s or higher was required for the temperature in the escape route less than $^{\circ}C$ for the given situations.

Numerical Analysis of Smoke Control for high-rise Building Considering with the Enthalpy Equation (Enthalpy Equation을 이용한 고층 건물의 제연해석)

  • Bae, Sung-Ryong;Ro, Kyoung-Chul;Ko, Gwon-Hyun;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.27-32
    • /
    • 2010
  • Recently, increases of population density due to the industrialization in the metropolitan cities has caused the high-density and integration of life environment. Then various high-rise buildings are constructed for accommodation. However, high-rise building fires can cause high casualties due to increases of smoke spread velocity through the vertical shaft. In this study, the new program based on the enthalpy conservation for analysis of energy transfer for smoke control system, CAU_ESCAP, was developed. CAU_ESCAP was validated by comparing with the result of ASCOS. The characteristic of smoke control was analysed by using CAU_ESCAP for high-rise building fires.

Basic Study on the Auto Closing System Development of Door at Smoke Control Zone (제연구역 출입문의 자동폐쇄장치 개발에 관한 기초 연구)

  • Lee, Dong-Myung;Yu, Byung-Ku
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.333-339
    • /
    • 2010
  • 본 연구는 제연구역 출입문의 자동폐쇄장치를 개발하기 위한 기초 연구로서, 자동폐쇄장치의 프로세스와 자동폐쇄조절장치의 기구학적 메커니즘 정립 및 기구 모델링을 바탕으로 자동폐쇄장치의 해석이론을 정립하였고, 해석이론을 바탕으로 한 운동해석 시뮬레이션을 통해 폐쇄력 장치를 선정하고 자동폐쇄조절장치의 각 요소를 개발할 수 있는 엔지니어링 데이터 구축과 원천기술을 확립하였다. 자동폐쇄장치의 개발에 유연성과 탄력성을 줄 수 있고, 자동폐쇄장치의 개발로 인해 연기의 제어수단과 기술적 대책마련과 제연시스템의 높은 신뢰성과 안정성을 확보할 수 있을 것으로 본다.

  • PDF

공동주택에 설치된 소화 및 제연시스템에 관한 화재연동 실태분석

  • Gang, Won-Seon;Son, Bong-Se;Jeong, Jong-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.11a
    • /
    • pp.161-162
    • /
    • 2013
  • 최근에 신축되는 주상복합건축물이나 대단위 아파트단지는 지상층에서 보면 각각이 독립되어 있는 별도의 소방대상물로 보이지만, 실제로는 지하층을 통하여 연결된 하나의 소방대상물이다. 이러한 건물의 지하층에서 화재가 발생하면 열이나 연기가 다른 동으로 확산되어 피해가 커질 수 있으며, 특정동의 소방펌프에서 고장이 발생하거나 우발적인 선로합선 등으로 인하여 수신기에 이상이 발생하면 전체 동에 설치된 소방시설이 정상적으로 작동되지 않는 경우가 발생하게 된다. 화재감지기의 신호에 따라 작동되는 제연댐퍼, 준비작동식 스프링 클러설비 등이 수신기에서 연동되는 과정을 인천송도에 위치한 글로벌주상복합 단지를 토대로 하여 소화 및 제연설비의 연동실태를 분석하였다.

  • PDF

Analysis of Smoke Spread Effect Due to The Ventilation Capability in Underground Subway-Station (대심도 역사의 제연팬 용량에 따른 연기확산 영향 분석)

  • Koo, In-Hyuk;Jang, Yong-Jun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.424-427
    • /
    • 2012
  • 본 연구에서는 최근 증가하고 있는 대심도역사의 제연팬 용량에 따른 연기확산영향에 대하여 분석하였다. 시뮬레이션모델은 신금호 역사(5호선, 깊이 46m)를 대상으로 하였으며, 제연팬 용량에 따른 연기확산 영향을 분석 하였다. 현장조사 및 실측을 통하여 계측된 실제 역사의 제연팬에 관한 데이터를 화재시뮬레이션 조건으로 적용하였다. 역사전체를 해석 대상으로 하여 총 400만개의 격자를 사용하였으며, 제연팬 용량에 따른 연기확산 영향 비교를 위하여 화재 시나리오를 작성하여 Case별로 화재해석을 수행하였다. 계산 효율을 높이기 위하여 MPI병렬처리기법을 사용하였으며 해석코드는 LES(large eddy simulation) 기법을 주로 사용하는 FDS5 code를 사용하였다.