• Title/Summary/Keyword: 연기발생량

Search Result 125, Processing Time 0.029 seconds

Experimental and Numerical Studies on Heat/Smoke Behavior due to a Fire on Underground Subway Platform (II) - Numerical Approach - (지하철 역사 승강장 화재발생시 열/연기 거동 분석을 위한 실험 및 수치 연구(II) - 수치적 접근 -)

  • Chang, Hee-Chul;Kim, Tae-Kuk;Park, Won-Hee;Kim, Dong-Hyeon
    • Fire Science and Engineering
    • /
    • v.20 no.3 s.63
    • /
    • pp.15-20
    • /
    • 2006
  • In this study the flow characteristics of smoke and heat on a bank type platform of the underground subway station are studied numerically by considering two different emergency operation modes. Effects of the natural flow through the tunnel and the stair ways are considered in the numerical simulations by using the measured velocities presented in Part I as the boundary condition. Distributions of heat, smoke, visible range and toxic gas on the platform are analysed for different smoke extraction flowrates corresponding to the two different emergency operation modes. The numerical results show that the extraction flowrate affects the smoke control performance significantly by improving the smoke removal performance as the extraction flowrate is increased.

Evacuation Simulation of High-Rise Building Fires Considering Temperature and Smoke (열화와 연기를 고려한 고층 건물 화재시의 대피 시뮬레이션)

  • Lee, Bum-Jong;Park, Jong-Seung;Rie, Dong-Ho
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.703-707
    • /
    • 2008
  • This paper proposes a method of design and implementation a simulation system in which humans can plan their evacuation paths in a high-rise building considering damages from high temperature and smoke in case of fire. Humans in evacuation search the nearest exit and follow a path to the exit. When humans are evacuating toward an exit, they are going to move with their highest speeds. However, many environmental factors prohibit their fast movements. In this paper, we calculate the evacuation speed of each human considering temperature damage and smoke damage. We restrict the number of humans that can be evacuated per second according to the actual size of the exit door. Experimental results showed that the evacuation speed is affected by the temperature condition and the smoke density.

  • PDF

Primary Fire Behavior of Compounded Multiplex Theater with Various Fire Conditions (조합형 복합상영관에서의 화재조건에 따른 초기화재 거동해석)

  • Park, Yong-Hwan
    • Fire Science and Engineering
    • /
    • v.21 no.1 s.65
    • /
    • pp.1-6
    • /
    • 2007
  • This paper investigated the fire and smoke behavior in the compounded multiplex theater using FDS with various spacial and boundary conditions to ensure the fire safety of the multiplex. The results showed that more rapid temperature increase and smoke can be induced near the exit door for the lower fire load duo to the horizontal smoke movement. The overuse of fire resistants can generate more smoke while delaying combustion rate, which can give adverse effect to the evacuation. The mal-function of the exhaust fan would obstruct smoke exhaust but also retard the function of sprinkler head.

An Experimental Study of Smoke Control in Tunnel Fires with Jet Fan (터널화재시 제트팬에 의한 연기제어에 관한 실험적 연구)

  • 이성룡;김충익;유홍선;방기영
    • Tunnel and Underground Space
    • /
    • v.12 no.2
    • /
    • pp.92-98
    • /
    • 2002
  • In this study reduced-scale experiments were conducted to analyze smoke movement in tunnel fire with jet fan, The 1/20 scale experiments were carried out under the froude scaling using gasoline pool fire range from 6.6 to 12.5 cm in diameter with total heat release rate from 0.714 to 4.77 kW. In the case of fires under the 2.5kW, backlaying was reduced about 40cm and smoke was effectively controled in downstream of the fan when operating the fan. The smoke layer was moved down and the ceiling temperature was decreased compared to that of without fan case in upstream of the fan, but the temperature in the lower part of the tunnel was increased.

Experimental Study on the Effect of the Area Ratio between Shaft and Tunnel and Heat Release Rate on the Plug-holing Phenomena in Shallow Underground Tunnels (저심도 도로터널에서 터널과 수직환기구의 단면적 비와 열방출률이 Plug-holing 현상에 미치는 영향에 관한 실험연구)

  • Hong, Kibea;Na, Junyoung;Ryou, Hong Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.4
    • /
    • pp.619-625
    • /
    • 2019
  • It is difficult to design because of the plug-holing phenomenon in which the amount of smoke discharged from the vertical vent is smaller than the designed amount of smoke. In this study, the effect of cross-sectional area ratio of tunnel and natural ventilation and heat release rate of fire source on plug-holing phenomenon occurring in natural ventilation system was experimentally analyzed. In the experiment model reduced to 1/20 size, the aspect ratio of the tunnel and the vertical vent was fixed, and the influence on the plug-holing phenomenon was confirmed by varying the sectional area ratio of the tunnel and the vertical vent. Experimental results show that the plug-holing phenomenon is caused by the comparison of the smoke boundary layer temperature with the temperature in the vertical vents, and the flow and temperature distribution characteristics under the vertical vents are changed as the cross-sectional area ratio of the tunnel and vertical vents increases. The plug-holing phenomenon is affected by the cross-sectional area ratio between the tunnel and the vertical ventilation. The greater the cross-sectional area ratio, the greater the probability of plug-holing.

A Study on the Effects of Flame Retardants in Unsaturated Isophthalic Acid Polyester Resin (불포화 이소프탈산 폴리에스터 수지의 난연제 첨가 효과 연구)

  • 최원종
    • Fire Science and Engineering
    • /
    • v.12 no.4
    • /
    • pp.41-49
    • /
    • 1998
  • In this study, the thermal improvement of an isophthalic acid polyester resin by the incorporation of flame retardants has been investigated. Aluminium hydroxide, antimony oxide and alumina powder were used to formulate the flame retardant systems. The improvement of an isophthalic resin by incorporating aluminium hydroxide is dramatic(burning rate and smoke emission are reduced), although the mechanical property is decreased significantly. The addition of small amount(2.5 phr) of antimony oxide produces high char yield(31%) which acts as a protective layer on the surface of the resin.

  • PDF

Study of Smoke Behavior and Differential Pressure in the Refuge Safety Area According to Damper Capacity of Smoke Control (제연댐퍼 송풍량에 따른 피난 안전 구역 차압 및 연기 거동 특성 연구)

  • Lee, Jae-Bin;Moon, Joo-Hyun;Lee, Seong-Hyuk;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.25 no.4
    • /
    • pp.103-109
    • /
    • 2011
  • In this study, we calculated the smoke movement at the fire area of the refuge floor which has the refuge safety area in case of fire in the high rise building by using a computational fluid dynamics (CFD) code of FLUENT (ver. 13.0). The buoyancy plume was applied using the temperature and flow velocity which represent 10 MW heat release rate in order to describe the fire, and the smoke movement was predicted using a species conservation equation. The pressurization system of smoke control was adopted with smoke control damper in refuge safety area, at the result, it is confirmed that the damper capacity was enough to smoke control in which the flow rate of supply was applied 25 $m^3/s$ in the case of the door at fire area opened only, and 50 $m^3/s$ in the doors at the fire area and lobby both opened case. They were satisfied in NFSC 501-A. Even though the door of fire area closed, there were smoke leakages at the gap between the door and wall. In addition, the refugee could be isolated in the fire area when the door of fire area closed during smoke control in the case of using the high damper flow rate of supply, 50 $m^3/s$. Therefore the proper damper flow rate of supply are needed in order to prevent the damage of refugee and this study proposes the suitable condition of damper capacity according to refuge scenario.

A study on the effective fire and smoke control in transverse oversized exhaust ventilation (횡류식 선택대배기환기에서의 배연특성에 관한 연구)

  • Han, Sang-Pil;Jeon, Yong-Han
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.13 no.6
    • /
    • pp.451-462
    • /
    • 2011
  • The smoke control system plays the most important role in securing evacuation environment when a fire occurs in road tunnels. Smoke control methods in road tunnels are classified into two categories which are longitudinal ventilation system and transverse ventilation system. In this study it is intended to review the characteristics of smoke behavior by performing numerical analysis for calculating the optimal smoke exhaust air volume with scaled-model and simulation when a fire occurs in tunnels in which transverse ventilation is applied, and for obtaining the basic data required for the design of smoke exhaust systems by deriving optimal smoke exhaust operational conditions for various conditions. As a result of this study, when the critical velocity in the tunnel is 1.75 m/s and 2.5 m/s, the optimal smoke exhaust air volume has to be more than $173m^3/s$, $236m^3/s$ for the distance of the smoke moving which can limit the distance to 250 m. In addition, in case of uniform exhaust the generated smoke is effectively taken away if the two exhaust holes near the fire region are opened at the same time.

A Study on the Effective Fire and Smoke Control in Road-Tunnel with Semi-Transverse Ventilation (Oversized Exhaust System) (도로터널 화재시 반횡류식 환기방식에서의 최적배연 연구(대배기구 방식))

  • Kim, Jong-Yoon;Jeon, Yong-Han
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.79-84
    • /
    • 2009
  • The smoke control system plays the most important role in securing evacuation environment when a fire occurs in road tunnels. Smoke control methods in road tunnels are classified into two categories which are longitudinal ventilation system and transverse ventilation system. In this study it is intended to review the characteristics of smoke behavior by performing numerical analysis for calculating the optimal smoke exhaust air volume when a fire occurs in tunnels in which transverse ventilation is applied, and for obtaining the basic data required for the design of smoke exhaust systems by deriving optimal smoke exhaust operational conditions for various conditions. As a result of this study, when the critical velocity in the tunnel is 1.75m/s and 2.5m/s, the optimal smoke exhaust air volume has to be more than $173m^3/s$, $236m^3/s$ for the distance of the smoke moving which can limit the distance to 250m. In addition, in case of uniform exhaust the generated smoke is effectively taken away if the two exhaust holes near the fire region are opened at the same time.

Numerical Improvement of Advection Term for Realistic Smoke Simulation (사실적인 연기 시뮬레이션을 위한 이류항 계산의 수치적 개선)

  • Chang, Mun-Hee;Park, Su-Wan;Kim, Eun-Ju;Ryu, Kwan-Woo
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2006.10a
    • /
    • pp.143-147
    • /
    • 2006
  • 자연 현상에서 나타나는 연기나 난류의 움직임을 사실적으로 시뮬레이션을 할 때 Navier-Stokes 방정식을 이용한다. 이 방정식을 이용한 구현은 방대한 연산량과 계산의 복잡성으로 인하여 실시간 시뮬레이션이 어렵다. 이 때문에 실시간 처리를 위하여 복잡한 수식을 근사화한다. 유체 시뮬레이션의 이류(advect) 과정에서 근사화를 위해 Semi-Lagrangian 방법을 이용할 때, 연기 시뮬레이션은 시간이 지남에 따라 밀도가 현저히 줄어들고 소규모의 소용돌이(small-scale vorticity) 현상이 급격히 감소하는 등의 수치적 소실이 발생한다. 본 논문에서는 이 문제를 해결하기 위해 이류항(advection term)을 계산할 때 새로운 수치적 방법을 제안한다. 본 논문에서는 이류항의 값을 구할 때, 현재 격자 주변의 값 중에서 다음 단계에 현재 격자의 위치로 오는 속도를 가진 격자를 찾아, 그 격자의 속도를 이류 속도 벡터로 활용한다. 이는 밀도와 소용돌이 현상의 수치적 소실을 줄여서 사실성을 높이고 실시간 처리도 가능하게 한다. 또한 본 논문에서는 GPU 구현을 통해 벡터 연산 등의 효율성을 높이며 시뮬레이션의 속도를 향상시킨다.

  • PDF