• Title/Summary/Keyword: 연구초심자

Search Result 27, Processing Time 0.019 seconds

Development of Universal Graphic User Interface Design for MS Windows for Elderly Users (고령사용자를 위한 MS Windows유니버설 GUI디자인 개발)

  • Kim, Mi-Young;Kim, Hyun-Jeong
    • Archives of design research
    • /
    • v.19 no.1 s.63
    • /
    • pp.15-26
    • /
    • 2006
  • As the interest and use of computer have been increased among elderly users according to the entry to the aging society, the issue of universal design for computer usability was brought forward. Especially, it is widely recognized that universal UI(User Interlace) design on MS windows is important. The objective of this study is to conceptualize Universal GUI design on MS windows which can be used more easily and intuitively by novice users such as elderly and housewives. Especially, the solution for Universal GUI design on MS windows was developed by reflecting elderly users' needs because elderly users is the group with more difficulties than other user groups in learning and using MS windows. First, elderly user's needs was collected by participant observation as a teaching assistant in computer dass for elderly people for 4 weeks. Secondly, the experimental test and in-depth interview was implemented to find difficulties factors and needs in addition to participant observation. Based on the findings, the new GUI design solution was suggested. The design solution consists of ideas in several categories such as setting default, simplification of function for easy conceptual model making, customization of function and working environment, and intuitive GUI in interaction process. The new MS windows GUI design can be accessed by novice mode when user login in window XP. This study has the significance in finding elderly users detailed needs through in-depth and long term participant observation. However, the usability of the suggested prototype needs to be verified to various user groups besides elderly users in the future.

  • PDF

The Effect of indoor illuminance depends on direction of the side windows lighting (측창채광의 방향에 따른 실내조도의 영향)

  • Cho, Shee-Man;Kim, Won-Joong;Jang, Woo-Jin
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.253-260
    • /
    • 2004
  • 실내의 조명은 자연채광방식과 인공조명으로 나누어지는데 자연형 채광방식에서도 측창채광과 천창채광, 정 측창채광 그리고 반사 채광방식이 있다. 측창채광은 벽면에 대하여 일반적으로 연직인 창에 의한 채광을 말한다. 측창채광의 방향에 따라 실내조도는 영향을 많이 받는다. 따라서 본 연구는 측창채광의 동서남북의 방향에 따라 봄, 여름, 가을, 겨울의 계절에 따라 아침, 점심, 저녁시간대에 따라 변화되는 실내조도를 알아보았다. 실험방법은, 조명시뮬레이션 프로그램인 Lightscape V3.2를 사용하여 교실공간의 치수와 작업면의 높이를 가로 5.8[m], 세로 10.8[m], 높이 3[m], 작업면의 높이 0.75[m]로 정하였고, 각 시설물의 반사율[p]은 벽 80%, 창문 12%, 출입문 13%, 바닥 20%, 천장 85%로 지정하였으며 창문의 투과율은 88%로 설정하였다. 본 연구에서 측정하고자 하는 변수 값은 계절은 여름을 6월20일, 겨울은 1월20일 기준으로 하고 시간대는 09시, 13시, 18시로 하였으며 창측방위는 동, 서, 남, 북으로 정하였으며 계절과 시간은 가장 차이가 많이 나는 값을 선택하였다. 결론으로 창이 남쪽일 때 평균조도가 9,100[lx]로 가장 높았고, 시간별로는 점심에 19,590[lx]로 조도가 가장 높은 것을 알 수 있었고 조도 균제도는 창이 동쪽일 때 겨울에 가장 높았다. 창이 북쪽일 때는 여름이 겨울보다 평균조도가 약간 높았고, 시간별로는 아침에 조도가 약간 높은 것을 알 수 있었고 전체적으로 북쪽 창에서 실내조도가 현저하게 떨어지는 것을 알 수 있었다. 이와 같은 결과로 측창의 브라인드를 현재 사용하고 있는 수직 브라인드 대신에 수평 브라인드를 사용하여 주광의 범위를 넓게 조절하여 사용하게 하고, 점등제어를 현재 측창면과 수직으로 되어있는 배열을 수평으로 한다면 자연채광의 효과를 배가 할 수 있으리라고 사료된다. 미백 전, 미백후, 재광화 후 미세경도 변화 양상이 미백을 하지 않은 대조군과 차이를 보이지 않았으며 (p > 0.05) 미백 전과 미백 후의 미세경도의 차이 미백후와 재광화 후의 미세경도의 차이도 유의할 만한 차이가 없었다 (p > 0.05). 따라서 시중에 판매되고 있는 whitening strip과 미백 젤은 14일 동안의 통상적인 미백과정 동안 법랑질의 미세경도에 영향을 미치지 않는 것으로 사료된다.able pitch와 helical angle보다는 근본적으로 radial land가 screw-in effect의 예방에 더 큰 역할을 하는 것으로 추정될 수 있다 따라서 NiTi file의 사용 경험이 없는 초심자의 경우 근단부 폭경의 유지능력이 좋은 ProFile$^{(R)}$의 사용이 추천된다.)되었다.였으나 강남콩군 외에는 단백질의 소화 흡수율 및 효율은 크게 향상되지 않아 단백질의 소화 흡수율을 떨어뜨리는 요인에 관한 연구가 집중적 으로 이루어져야 하리라고 생각된다.면 바로 위 지점의 풍속을 측정하였다. 각 Seeding 물질에 대해 팬을 켜지 않았을 때, 즉 바람의 영향이 없을 때 측정한 표면유속을 바람의 세기가 변한 경우의 기준 표면유속으로 이용하였다. 본 연구의 결과 비중이 0.01 내외인 Ecofoam과 white polystyrene에 비해 비중이 0.92인 black polypropylene은 대부분이 물속에 잠겨 있어 흐름과 거의 일치하여 움직임을 알 수 있었다. 또한 흐름의 평균유속이 0.165 m/s의 저유속에서 바람이 tracers에 미치는 영향이 평균유속 0.558m/s인 경우보다 커서, 바람의 세기의 증가에 따라 표면유속 측정값이 급속히 감소되었다. 흐름의 평균유속이 큰 경우에는 바람이 tracer에 마치는 영향이 현격히 줄어듬을 보이고 있다. 결론적으로 유속이 증가함에 따라 바람의 영향은 감소하나, 바

  • PDF

Development of Expert System for Designing Power Transmission Gears (II) (동력전달용 치차설계 전문가 시스템 개발연구 II)

  • 정태형;변준형;이동형
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.1
    • /
    • pp.122-131
    • /
    • 1992
  • An expert system is developed which can design the power transmission involute cylindrical gears on the basis of strength and durability. Bending strength, surface durability, scoring, and wear probability are considered as the basis. The basic components of the expert system are knowledge base, inference engine, and working memory. The knowledges in knowledge base are classified hierarchically into the knowledges used in selection of gear type, selection of materials, and determination of K factor and are represented by rules. In the inference engine two inference methods are implemented with the depth first search method. For-ward chaining method is introduced in the selection of gear type and materials and in the determination of K factor. Backward chaining method is introduced in the detailed design of module and face width in accordance with the validation of strength. And inference efficiency is achieved by constructing the part needing a lot of numerical calculations in strength estimation separately from inference mechanism. The working memory is established to save the results during inference temporarily. In addition, design database of past design results is built for consultation during design and knowledge acquisition facility, explanation facility, and user interface are included for the usefulness of user. This expert system is written with the PROLOG programming language and the FORTRAN language in numerical calculation part which interfaced with PROLOG and can also be executed on IBM-PC compatible computer operated by MS-DOS alone.

Categorizing Canadian Students' Cognition Type on Korean Food Consumption: Focused on Q-methodology (캐나다 대학생의 한국음식 소비유형분류: Q방법론을 중심으로)

  • Kim, Jin-Kang;Lee, Chun-Su
    • International Commerce and Information Review
    • /
    • v.13 no.2
    • /
    • pp.75-94
    • /
    • 2011
  • This study is designed to expand 'Q-Methodology' into the global marketing realm in attempt to find out how Canadian consumers will perceive Korean food. The ultimate aim of this thesis is to lay a basic foundation to globalize Korean food and heighten the potential and quality of Korean food. Korean food, well-known as slow diet, jumps on the bandwagon of the Korean Wave and spreads at a rapid pace. At this point, most Korean food becomes widespread under the influence of the boom of not just the Korean Wave but also the growing desire for health food. Hence, it is the most important to analyze consumers' types in order to learn how each individual nation perceives Korean Food. This can be used as the basic research and study to enhance the national competitiveness of Korean food. Q-methodology is adopted in this study to reveal the critical dimensions and characteristics of the target market and/or consumers for Korean Food using the Canadian respondents' subjective attributes. Three categories (pragmatic trend type, traditional culture seeking type, a beginner type) of Canadian consumer behavior regarding Korean Food are found and suggested in this study. The objective attributes of Korean food are not considered here, but the Canadian consumers' subjective behavioral attributes are.

  • PDF

An analysis on satisfaction level of clinicians on implant surgical guidance system based on computed tomography (컴퓨터 단층 촬영을 기반으로 한 임플란트 가이드 시스템에 대한 임상가의 만족도 분석)

  • Hong, Min-ho;Jin, Ming-Xu;Lee, Du-Hyeong;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.3
    • /
    • pp.178-185
    • /
    • 2015
  • Purpose: The purpose of this study was to conduct a comparative assessment on the satisfaction level for the two interfaces of surgical guide system (SimPlant and R2GATE), the design and convenience of manufactured surgical guides and the importance of using the surgical guides thereof by means of survey. Materials and Methods: Hereupon, they simulated the implant surgical process by mounting the two manufactured systems of surgical guide on a dental mold, respectively. The study subjects were instructed to complete the questionnaire as to the satisfaction level upon completion of the simulated surgery. This study summarized the data of each question after collecting the completed questionnaires. Then, this study analyzed the summarized data by utilizing statistical program SPSS 20.0 (IBM). Results: R2GATE had a higher value of the satisfaction level on the design and convenience of manufactures surgical guides. R2GATE group ($7.33{\pm}1.26$) was found to have a higher value in terms of the overall satisfaction level compared to SimPlant group ($6.67{\pm}1.26$) (${\alpha}$ = 0.05). Conclusion: The user satisfaction level on the surgical guide manufactured for R2GATE system was to such an extent as it can be widely used in clinical environment. Moreover, the surgical guide manufactured as R2GATE system can guide both the length and direction of a drill simultaneously. As a result, it is highly recommended for those beginners who do not have a lot of experience in implant placement.

Relative efficacy of three Ni-Ti file systems used by undergraduates (학생들이 사용한 세 종류 Ni-Ti file systems의 근관성형 효율 비교)

  • Kim, Hyeon-Cheol;Park, Jeong-Kil;Hur, Bock
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.1
    • /
    • pp.38-48
    • /
    • 2005
  • The purpose of this study was to compare and evaluate the shaping ability of the three different Ni-Ti file systems used by undergraduate students. Fifty undergraduate students prepared 150 simulated curved root canals in resin blocks with three Ni-Ti file systems - $ProFile^{(R)}$ (PF), Manual $ProTaper^{(R)}$ (MPT), Rotary $ProTaper^{(R)}$ (RPT). Every student prepared 3 simulated root canals with each system respectively. After root canal preparation, the Ni-Ti files were evaluated for distortion or breakage Assessments were made according to the presence of various types of canal aberrations. The pre- and post-instrumented canal images were attained and superimposed. The instrumented root canal width were measured and calculated for the net transportation (deviation) and the centering ratio. Under the condition of this study, both $ProTaper^{(R)}$ systems allowed significantly more removal of root canal wall than the $ProFile^{(R)}$ system. In the important other aspects such as the centering ratio, there was no significant differences between the systems. Novice dental students were able to prepare curved root canals with any kinds of Ni-Ti file systems with little aberration and great conservation of tooth structure. Students want to learn effective methods and at the same time simple rotary procedures. The rotary $ProTaper^{(R)}$ systems were one of the most compatible to these students from the point of view of cutting ability The $ProFile^{(R)}$ system was also compatible in safe and gentle shaping.

Comparison of screw-in effect of three NiTi file systems used by undergraduates (학생들이 사용한 세 종류 NiTi file systems의 screw-in effect 비교)

  • Oh, Seung-Hei;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.6
    • /
    • pp.477-484
    • /
    • 2006
  • The purposes of this study were to compare the apical terminus width of simulated curved root canal prepared with three NiTi file systems used by undergraduates for evaluation the effects of flute angle and pitch or radial land on reducing screw-in effect and to determine more safe NiTi file system for inexperienced operators. Fifty inexperienced undergraduate students prepared 150 simulated curved root canals in resin blocks with three NiTi file systems ; ProFile$^{(R)}$, Hero Shaper$^{(R)}$, K3$^{TM}$. The electric motor set at a speed of 300 rpm and torque of 30 in a 16 : 1 reduction handpiece was used. The simulated root canal was prepared to ISO #25 sizes with each file system. The scanned images of pre- and post-instrumented canal of resin block were superimposed. To evaluate the screw-in effect of three NiTi file systems, apical terminus width of root canal was measured from superimposed images and statistical analysis was performed. There were significant differences in three NiTi flle systems. ProFile$^{(R)}$ had significantly smaller width than Hero Shaper$^{(R)}$ and K3$^{TM}$"" (P < 0.05), but no significant difference was observed between K3$^{TM}$ and Hero Shaper$^{(R)}$. Under the condition of this study, active file system (Hero SHaper$^{(R)}$, K3$^{TM}$) with variable pitch and helical angle had more screw-in effect than passive file system (ProFile$^{(R)}$) with constant pitch and helical angle. It seems that the radial lands play more important role in reducing screw-in effect.