• Title/Summary/Keyword: 연구장비 활용

Search Result 2,305, Processing Time 0.036 seconds

Changes and Improvements of the Standardized Eddy Covariance Data Processing in KoFlux (표준화된 KoFlux 에디 공분산 자료 처리 방법의 변화와 개선)

  • Kang, Minseok;Kim, Joon;Lee, Seung-Hoon;Kim, Jongho;Chun, Jung-Hwa;Cho, Sungsik
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.20 no.1
    • /
    • pp.5-17
    • /
    • 2018
  • The standardized eddy covariance flux data processing in KoFlux has been updated, and its database has been amended accordingly. KoFlux data users have not been informed properly regarding these changes and the likely impacts on their analyses. In this paper, we have documented how the current structure of data processing in KoFlux has been established through the changes and improvements to ensure transparency, reliability and usability of the KoFlux database. Due to increasing diversity and complexity of flux site instrumentation and organization, we have re-implemented the previously ignored or simplified procedures in data processing (e.g., frequency response correction, stationarity test), and added new methods for $CH_4$ flux gap-filling and $CO_2$ flux correction and partitioning. To evaluate the effects of the changes, we processed the data measured at a flat and homogeneous paddy field (i.e., HPK) and a deciduous forest in complex and heterogeneous topography (i.e., GDK), and quantified the differences. Based on the results from our overall assessment, it is confirmed that (1) the frequency response correction (HPK: 11~18% of biases for annually integrated values, GDK: 6~10%) and the stationarity test (HPK: 4~19% of biases for annually integrated values, GDK: 9~23%) are important for quality control and (2) the minimization of the missing data and the choice of the appropriate driver (rather than the choice of the gap-filling method) are important to reduce the uncertainty in gap-filled fluxes. These results suggest the future directions for the data processing technology development to ensure the continuity of the long-term KoFlux database.

Investigation of the Condition of the Operation of the Livestock Liquid Manure Bin and Assessment of Malodorant Emissions (축분뇨 액비 저장조의 운영실태 및 악취 물질 발생량 조사)

  • Kim T. I.;Song J. I.;Joung S.;Jeong J. W.;Chung E. S.;Barroga A. J.;Yoo Y. H.;Yang C. B.;Kim M. K.
    • Journal of Animal Environmental Science
    • /
    • v.11 no.3
    • /
    • pp.189-196
    • /
    • 2005
  • This study was carried out to determine the acceptability of liquid manure bin among livestock farmers and agricultural farmers, and quantify its malodorous compounds. The results were as follows; 1. The size of the manure bins owned by $93\%$ of 60 farmers surveyed was 200 M/T and were all in normal operation. Around $57\%$ of the normally operated bins were processed under aerobic condition. 2. Filly percent of the respondents utilized their liquid manure bin twice a year while $64\%$ used commercial microbial products to enhance maturity of their liquid manure and abatement of malodorous emissions. On the other hand, $43\%$ mentioned problems on the labor requirement, mechanical maintenance and lending cost of liquid manure processing and utilization, and the price of the commercial microbial products. 3. Malodorants emitted from livestock liquid manure bins and their boundary bin depended upon the livestock liquid manure processing condition. Within bin under the aerobic processing condition, Iso-valeric and propionic acid were ranged 0.012 to 0.07ppm and 0.17 to 2.85ppm, respectively. Within bin under the anoxic processing condition, n-butyric, n-valeric acid, and acetaldehyde were ranged 1.5 to 2.3ppm, 1.3 to 1.8ppm, and 0.8 to 2.1ppm, respectively. Malodorants emitted from the boundary of livestock liquid manure bins under the anoxic processing condition were detected the range of 0.4 to 0.9 ppm, more than the concentration of law regulation, as an acetaldehyde, but under the aerobic processing condition, they did not any detection.

  • PDF

A Survey of Perceptions of Elementary School Teachers on the Small-Scale Chemistry (미량화학(Small-Scale Chemistry)에 대한 초등학교 교사들의 인식)

  • Kim, Sung-Kyu;Kong, Young-Tae
    • Journal of Science Education
    • /
    • v.34 no.2
    • /
    • pp.291-305
    • /
    • 2010
  • The aim of this study was to survey the perceptions of the elementary school teachers on the smallscale chemistry(SSC) following its training session. The teachers participating in the survey were 266 teachers in the Gyeongnam province. They were given a questionnaire that focused on the nine areas of the SSC: Needs for the teacher training and its application, its benefits, issues of safety and danger as well as treatment of environmental pollution, its economic efficiency and the development of investigative skills. The designed questionnaire was checked by an authority, and the responses to each question were tallied and analyzed. The results are as follows. The biggest problems of the traditional experimental methods as rated by the teachers were, in the order of importance, the preparation time, the legal liability of teachers for the safety and accidents, financial issues, disposal of the experimental wastes and the lack of relevant data. Since most of the teachers had not experienced the SSC lab programs in the field, they responded positively to the questions of need for its introduction and training. The implementation of the experimental SSC lab programs should proceed in the following order: introduction into the textbook, teacher training program, after-school education and the invitation of instructors. The most useful materials for the SSC program were CDs, videos, books and various printed materials, in that order. The responses regarding benefits of the SSC program included its simplicity, convenience, time savings, diversity, qualitative and quantitative aspects, integration into the regular class and use of toys. In particular, the teachers mentioned the increased safety due to the small amount of experimental reagents needed and the durability of plastic instruments. The familarity from the use of everyday tools as well as easy access to and the low-cost of the instruments were other important benefits. The teachers in general rated the educational content of the program highly, but many also found it to be average. Some pointed out the lack of sufficient discussion due to the individual or pair groupings as a potential shortcoming. The potential for development of problem solving ability and improvement of skills was rated positively. The number of teacher who rated the development of creativity positively was just over the half. As for the area of improving investigative skills, many found its assessment difficult and confusing because of the lack of its systemic definition and categorization. Based on the findings of this study, I would like to recommend the application and a wider dissemination of the small-scale chemistry lab program into the elementary school science curriculum.

  • PDF

Quantitative Analysis of GBCA Reaction by Mol Concentration Change on MRI Sequence (MRI sequence에 따른 GBCA 몰농도별 반응에 대한 정량적 분석)

  • Jeong, Hyun Keun;Jeong, Hyun Do;Kim, Ho Chul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.2
    • /
    • pp.182-192
    • /
    • 2015
  • In this paper, we introduce how to change the reaction rate as mol concentration when we scan enhanced MRI with GBCA(Gadolinium Based Contrast Agent), Also show the changing patterns depending on diverse MRI sequences which are made by different physical principle. For this study, we made MRI phantom ourselves. We mixed 500 mmol Gadoteridol with Saline in each 28 different containers from 500 to 0 mmol. After that, MR phantom was scanned by physically different MRI sequences which are T1 SE, T2 FLAIR, T1 FLAIR, 3D FLASH, T1 3D SPACE and 3D SPCIR in 1.5T bore. The results were as follows : *T1 Spin echo's Total SI(Signal Intensity) was 15608.7, Max peak was 1352.6 in 1 mmol. *T2 FLAIR's Total SI was 9106.4, Max peak was 0.4 1721.6 in 1 mmol. *T1 FLAIR's Total SI was 20972.5, Max peak was 1604.9 in 1 mmol. *3D FLASH's Total SI was 20924.0, Max peak was 1425.7 in 40 mmol. *3D SPACE 1mm's Total SI was 6399.0, Max peak was 528.3 in 3 mmol. *3D SPACE 5mm's Total SI was 6276.5, Max peak was 514.6 in 2 mmol. *3D SPCIR's Total SI was 1778.8, Max peak was 383.8 in 0.4 mmol. In most sequences, High signal intensity was shown in diluted lower concentration rather than high concentration, And also graph's max peak and pattern had difference value according to the each different sequence. Through this paper which have quantitative result of GBCA's reaction rate depending on sequence, We expect that practical enhanced MR protocol can be performed in clinical field.

A Study on Establishment of Safety Training Center Based on Virtual Reality and Augmented Reality Technology for Military Safety and Suicide Accident Prevention (가상현실(VR/AR) 기술 기반으로 군 안전 및 자살사고 예방을 위한 안전체험훈련장 구축 방안에 관한 연구)

  • Choi, Sung-oh;Min, Yong-sik;Kim, Sung-Il;Ghoi, Jong-geun
    • Journal of Internet Computing and Services
    • /
    • v.21 no.2
    • /
    • pp.139-148
    • /
    • 2020
  • Due to change in circumstances in the 2000s such as severe birthrate decline and shortened military service period, the armed forces of the Republic of Korea is currently turning to technologies and equipments from manpower, developing it to become high-tech, high-speed, and complex, resulting in an environment in which a single mistake could cause a mass mortality crisis.It is also evident that, considering aspects such as safety training curriculums and achievements of advanced countries and private education, hands-on training is a must in preventing suicides and accidents in the military, and establishing safety training centers is crucial for systematic and effective hands-on training.Soldiers who are joining the army as of now have experienced the Internet ever since they were born and easily use both virtual and augmented reality, and the current level of science and technology has developed to the point where most of the public safety experience centers are able to be replaced by virtual and augmented reality (VR/AR). Therefore, considering the aspects such as installation space, construction costs, maintenance costs, user characteristics, and education effects, other than for those trainings where real models and objects are more effective such as first aid training, it is with a strong recommendation that establishing military safety training facilities with VR/AR (Virtual and augmented reality) is a must in the coming future. We have derived the need for hands-on training by considering the development of virtual and augmented reality (VR/AR), analysis of operation status of the public safety experience centers, characteristics of military units, installation and maintenance costs, and proposed plan to establish safety training centers where effective training performance can be achieved at a lower cost than the public safety experience center. In addition, we suggested the scale of the required safety training center and the composition of the experience rooms considering the number of trainees and the environment of each military units. Given this analysis it will contribute to the prevention of military safety and suicide by building a safety training center in the future.

A Comparison of Discriminating Powers Between 14 Microsatellite markers and 60 SNP Markers Applicable to the Cattle Identification Test (소 동일성 검사에 적용 가능한 14 Microsatellite marker와 60 Single Nucleotide Polymorphism marker 간의 판별 효율성 비교)

  • Lim, Hyun-Tae;Seo, Bo-Yeong;Jung, Eun-Ji;Yoo, Chae-Kyoung;Yoon, Du-Hak;Jeon, Jin-Tae
    • Journal of Animal Science and Technology
    • /
    • v.51 no.5
    • /
    • pp.353-360
    • /
    • 2009
  • When 14 microsatellite (MS) markers were applied in the identifying test for 480 Hanwoo, the discriminating power was estimated as $3.43{\times}10^{-27}$ based on the assumption of a random mating group (PI). This rate is 1,000 times higher than that of 60 single nucleotide polymorphism (SNP) markers. On the other hand, the power of the 60 SNP markers was estimated as $4.69{\times}10^{-20}$ and $8.02{\times}10^{-12}$ on the assumption of a half-sib mating group ($PI_{half-sibs}$) and a full-sib mating group ($PI_{sibs}$), respectively. These powers were 10 times and 10,000 times higher than those of the 14 MS markers. The results indicated that the total number of alleles (MS vs SNP = 146 vs 120) acted as a key factor for the discriminating power in a random mating population, and the total number of markers (MS vs SNP = 14 vs 60) was a dominant influence on the power in half-sib and full-sib populations. In the Hanwoo population, in which it was assumed that the entire population is the enormous half-sib group formed by the absolute genetic contribution of a few nuclear bulls, there will be only a 10 times difference in the discriminating power between the 14 MS markers and the 60 SNP makers. However, the probability of not excluding a candidate parent pair from the parentage of an arbitrary offspring, given that only the genotype of the offspring ($PNE_{pp}$) was 1,000 times higher as shown by the 14 MS markers than that by the 60 SNP markers. The strong points of SNP makers are the stability of the variation (low mutation rate) and automation of high-throughput genotyping. In order to apply these merits for the practical and constant Hanwoo identity test, research and development are required to set a cost-effective platform and produce a homemade apparatus for SNP genotyping.

The Clinical Usefulness Measurement of the Whole Body Percent Fat Calculated by the Part Bone Mineral Density Measurement (부분골밀도 측정을 통해 산출되는 체지방률의 임상적 유용성에 대한 평가)

  • Kang, Young-Eun;Kim, Eun-Hye;Kim, Ho-Sung;Choi, Jong-Sook;Choi, Woo-Jun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.3-9
    • /
    • 2011
  • Purpose: Generally dual energy X-ray absorptiometry has been used for the purpose of evaluation of osteoporosis and treatment. Recently the interest of obesity came to be high and body percent fat test is increasing. Existing measure of body fat have to scan the whole body can be evaluated, but only lumbar spine and hip measurements was assumed to be whole body fat as well as improving the software. It tries to check whether the part measured value not being whole body measurement has the validity or not compared with the value calculated with the method that it is different, it forgives through a correlation with a (BIA) and (BMI). Materials and Methods: In 2010, the body percent fat was measured among the examinee coming to the Asan Medical Center public health care center from March till August against 90 females more than 40 years old through (DXA) and BIA. BMI utilized the value which wrote an hight and weight measured through the body measuring instrument in the examinee information and is automatically calculated. In addition, it classified as the low weight ($13-18.5kg/m^2$), normal ($18.5-25kg/m^2$), and corpulence ($25-30kg/m^2$) based on BMI and so that it could check whether there was the difference according to the weight or not BMI and BIA and correlation between DXA were analyzed in each group. The statistical program for the analysis used SPSS 12.0. Results: The comparison of DXA at 3 which it divides into the low weight and normal and corpulence groups and BIA did not show the difference noted statistically in all groups and the between group comparison was exposed to do not have a meaning. The body percent fat measured by the correlation analysis result DXA at the state that it doesn't divide into the group showed the high correlation (r=0.908, p0.01) noted statistically compared with BMI and showed the high correlation noted statistically in a comparison with BIA (r=0.927, p0.01). Conclusion: It confirmed that the whole body percent fat presumed from the part bone density measurement showed the excel correlation compared with BIA and BMI and information is high. There is still no clear standard about the presumed whole body percent fat and it is difficult to evaluate the fat evaluation by the bone mineral density measurement. However, it is determined that the information offering which is more objective through the comparative study with the body percent fat which is very efficient and in that it can obtain till the information about a fat as well as diagnosis of the osteoporosis through the bone density checkup is measured by the afterward telegraph bone density checkup and is clinically useful is possible.

  • PDF

A Study of the Change of Breast Uptake in Menstrual Cycle on $^{18}F$-FDG PET/CT (월경 주기에 따른 $^{18}F$-FDG PET/CT에서의 유방 섭취 변화에 관한 고찰)

  • Park, Min-Soo;Park, Hoon-Hee;Kim, Jung-Yul;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.39-44
    • /
    • 2011
  • Purpose: $^{18}F$-FDG PET/CT has been known a useful modality to diagnose high-glucose-using cells such as cancer cells by glucose metabolism of FDG. Mainly, FDG takes on cancer and inflammatory cells; However, There have been FDG uptakes on normal tissues by individual physiological characteristics, occasionally. Especially, in fertile females, unusual FDG uptake of breast changes as the menstrual cycle, and disturb diagnosis. Therefore, the study aimed to evaluate the change of breast FDG uptake in menstrual cycle on $^{18}F$-FDG PET/CT. Materials and Methods: 160 females ($34{\pm}3.5$ years old) who do not undergo a gynecologic anamnesis and have regular menstrual cycle over the previous 6 months were examined, from March 2009 to February 2010. They were divided 4 groups (each 40 patients) as flow phase, proliferative phase, ovulatory phase and secretory phase using Pregnancy Calculator 0.14. and history taking. Discovery Ste (GE Healthcare, Milwaukee, Mi, USA) was used as PET/CT. We analyzed SUVs on accumulated region on breast, and 3 nuclear medicine specialists did the Blind test. Results: SUVs on the Breast were flow phase ($1.64{\pm}0.25$), proliferative phase ($0.93{\pm}0.28$), ovulatory phase ($1.66{\pm}0.26$) and secretory phase ($1.77{\pm}0.28$). It showed high uptake value in secretory, flow phase and ovulatory phase (p<0.05). In gross analysis, the accumulation of breast was divided into 3 grades as comparing with lung and liver. The breast's uptake was equal to lung (Grade I); between lung and liver (Grade II); equal to or greater than liver (Grade III). The results showed high uptake value in secretory, flow phase and ovulatory phase (p<0.05). Conclusion: In fertile females, FDG uptake of breast changed as menstrual cycle, and it available to diagnose breast disease. Therefore, we consider reducing false-negative finding of breast disease, by doing examination on appropriate period through history taking about individual menstrual cycle.

  • PDF

Effects of Non-ionic Surfactant Tween 80 on the in vitro Gas Production, Dry Matter Digestibility, Enzyme Activity and Microbial Growth Rate by Rumen Mixed Microorganisms (비이온성 계면활성제 Tween 80의 첨가가 반추위 혼합 미생물에 의한 in vitro 가스발생량, 건물소화율, 효소활력 및 미생물 성장율에 미치는 영향)

  • Lee, Shin-Ja;Kim, Wan-Young;Moon, Yea-Hwang;Kim, Hyeon-Shup;Kim, Kyoung-Hoon;Ha, Jong-Kyu;Lee, Sung-Sil
    • Journal of Life Science
    • /
    • v.17 no.12
    • /
    • pp.1660-1668
    • /
    • 2007
  • The non-ionic surfactant (NIS) Tween 80 was evaluated for its ability to influence invitro cumulative gas production, dry matter digestibility, cellulolytic enzyme activities, anaerobic microbial growth rates, and adhesion to substrates by mixed rumen microorganisms on rice straw, alfalfa hay, cellulose filter paper and tall fescue hay. The addition of NIS Tween 80 at a level of 0.05% increased significantly (P<0.05) in vitro DM digestibility, cumulative gas production, microbial growth rate and cellulolytic enzyme activity from all of substrates used in this study. In vitro cumulative gas production from the NIS-treated substrates; rice straw, alfalfa hay, filter paper and tall fescue hay was significantly (P<0.05) improved by 274.8, 235.2, 231.1 and 719.5% compared with the control, when substrates were incubated for 48 hr in vitro. The addition of 0.05% NIS Tween 80 to cultures growing on alfalfa hay resulted in a significant increase in CMCase (38.1%), xylanase (121.4%), Avicelase (not changed) and amylase (38.2%) activities after 36 h incubation. These results indicated that the addition of 0.05% Tween 80 could greatly stimulate the release of some kinds of cellulolytic enzymes without decreasing cell growth rate in contrast to trends reported with aerobic microorganism. Our SEM observation showed that NIS Tween. 80 did not influence the microbial adhesion to substrates used in the study. Present data clearly show that improved gas production, DM digestibility and cellulolytic enzyme activity by Tween 80 is not due to increased bacterial adhesion on the substrates.

Nanoscale Pattern Formation of Li2CO3 for Lithium-Ion Battery Anode Material by Pattern Transfer Printing (패턴전사 프린팅을 활용한 리튬이온 배터리 양극 기초소재 Li2CO3의 나노스케일 패턴화 방법)

  • Kang, Young Lim;Park, Tae Wan;Park, Eun-Soo;Lee, Junghoon;Wang, Jei-Pil;Park, Woon Ik
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.27 no.4
    • /
    • pp.83-89
    • /
    • 2020
  • For the past few decades, as part of efforts to protect the environment where fossil fuels, which have been a key energy resource for mankind, are becoming increasingly depleted and pollution due to industrial development, ecofriendly secondary batteries, hydrogen generating energy devices, energy storage systems, and many other new energy technologies are being developed. Among them, the lithium-ion battery (LIB) is considered to be a next-generation energy device suitable for application as a large-capacity battery and capable of industrial application due to its high energy density and long lifespan. However, considering the growing battery market such as eco-friendly electric vehicles and drones, it is expected that a large amount of battery waste will spill out from some point due to the end of life. In order to prepare for this situation, development of a process for recovering lithium and various valuable metals from waste batteries is required, and at the same time, a plan to recycle them is socially required. In this study, we introduce a nanoscale pattern transfer printing (NTP) process of Li2CO3, a representative anode material for lithium ion batteries, one of the strategic materials for recycling waste batteries. First, Li2CO3 powder was formed by pressing in a vacuum, and a 3-inch sputter target for very pure Li2CO3 thin film deposition was successfully produced through high-temperature sintering. The target was mounted on a sputtering device, and a well-ordered Li2CO3 line pattern with a width of 250 nm was successfully obtained on the Si substrate using the NTP process. In addition, based on the nTP method, the periodic Li2CO3 line patterns were formed on the surfaces of metal, glass, flexible polymer substrates, and even curved goggles. These results are expected to be applied to the thin films of various functional materials used in battery devices in the future, and is also expected to be particularly helpful in improving the performance of lithium-ion battery devices on various substrates.