• Title/Summary/Keyword: 연결 열부하

Search Result 25, Processing Time 0.035 seconds

Heat Consumption Pattern Analysis by the Component Ratio of District Heating Users (지역난방 사용자 구성비에 따른 열소비 패턴 분석)

  • Lee, Hoon;Lee, Min-Kyun;Kim, Lae Hyun
    • Journal of Energy Engineering
    • /
    • v.22 no.2
    • /
    • pp.211-225
    • /
    • 2013
  • To run an optimal operation of Integrated energy supply facilities, we need to analyze heat consumption patterns of District heating users and derive optimum and maximum load ratio of heat production facilities unit. This study selects three District heat production facilities. It also classifies District heating users into residential apartment buildings and eight non-residential buildings and analyzes heat consumption results for an year. Finally it carries out the analysis of how the ratio change of each type affects maximum load ratio, facility utilization ratio, heat supply range. According to this study, three different District heat facilities of residential apartment building show similar daily and annual heat consumption patterns. Annual average load ratio, maximum load ratio and annual heat demand increase as outdoor temperatures decrease. Non-residential buildings in urban District focused on apartment buildings display similar by the daily and annual heat consumption patterns. Yet their daily and annual maximum load ratio differ according to outdoor temperature, District, building types and their composition ratio. In the case of urban District focused on apartment buildings reach optimum and maximum load ratio when apartment buildings reaches 60-70% of the total. At that point heat supply range becomes maximized and the most economic efficiency is obtained.

A Load Balancing Control Method For Parallel Connected Power Converter (병렬 연결형 전력 컨버터의 부하 균등제어 방법)

  • Kim, Chan-in;LEE, Chan-Kyo;Yoo, Hyo-Yol;Cho, Jung-Goo
    • Proceedings of the KIPE Conference
    • /
    • 2018.11a
    • /
    • pp.219-220
    • /
    • 2018
  • 대용량 전력 컨버터 시스템의 경우 전력 컨버터의 출력을 공통으로 연결하여 병렬로 전력을 공급한다. 그런데 이러한 병렬 연결형 전력 컨버터 시스템에서 별도의 부하 균등 제어방법을 사용하지 않을 경우 부하가 컨버터에 균등하게 분배되지 않기 때문에 많은 부하를 감당하는 컨버터의 경우 수명이 저하와 고장 또한 전체 시스템의 효율을 감소 시킨다. 때문에 보통의 병렬 연결 시스템의 경우 패시브한 방법으로 출력에 저항을 연결하여 저항 값을 조정하는 방법과 엑티브한 방법으로 마스터와 슬레이브를 구별하여 마스터가 출력 전류를 균등하게 보장하는 방법이 있다. 그러나 패시브한 방법의 경우 전력손실이 발생하고 엑티브한 방법의 경우 마스터와 슬레이브를 구별하여 생산하고 또한 마스터 고장의 경우 운영할 수 없게 된다. 본 논문에서는 전압센서의 게인을 기준 전압센서 값에 실시간으로 보정함으로써 적은 손실과 별도의 마스터 슬레이브의 구별없는 방법을 제안한다.

  • PDF

A Load Balancing Control Method Verification Test For Light weigh electric railway Using Wireless Power Transfer System (무선전력전송시스템을 적용한 경량전철의 부하균등제어방법 실증 시험)

  • Kim, Chan-in;Lee, Chan-Gyo;O, Yeong-Seok;Yoo, Hyo-Yol;Cho, Jung-Goo
    • Proceedings of the KIPE Conference
    • /
    • 2019.11a
    • /
    • pp.156-157
    • /
    • 2019
  • 경량전철과 같은 대용량 전력 시스템에 무선전력전송 기술을 적용할 때 전력변환장치의 병렬 운전은 필수적이다. 병렬 연결된 전력변환장치의 경우 출력이 공통으로 연결되어 전력을 공급하게 되는데, 이 때 집전 컨버터의 부하균등제어는 각각의 집전 컨버터의 부하 불균형을 막아줌으로써 집전 컨버터의 수명과 효율이 감소하는 것을 막아준다. 본 논문에서는 부하균등제어방법을 적용한 무선 경량전철 시스템을 통해 기존에 제안된 제어기법을 적용하여 검증하였다. 실증시험의 경우 경산에 위치한 한국철도기술연구원 경량전철시험선의 시험용 경량전철을 두 개의 역사를 반복하여 셔틀 운행하여 최대 400kW의 전력을 두 개의 집전 장치가 전력을 균등하게 공급하는 것을 확인 및 분석하여 논문의 타당성을 검증하였다.

  • PDF

Analysis on the Heat load Pattern According to Ratio of the Heat Consumers in District Heating (지역난방 열사용자 비율별 열부하 패턴변화 분석: 공동주택과 건물)

  • Lee, Hoon;Lee, Yoon-Pyo;Kim, Lae-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.3
    • /
    • pp.123-129
    • /
    • 2010
  • The district heating users can be generally classified into two groups such as apartments and buildings. In consideration that the time zone of the maximum heat load for apartments is different from those of buildings during a day, the maximum heat supply range is presented. In case of the investigated area, the maximum heat supply is occurred at the ratio between apartments and buildings that is 65%:35%. Thus the heat supply range is increased as much as 15% if the time zone when the maximum heat load is occurred is considered.

Analysis of Condenser Thermal Distribution by the Variance of Voltage & Frequency (전압 및 주파수 변동에 따른 콘덴서 열 분포 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.33-36
    • /
    • 2009
  • 콘덴서는 유도성 부하의 늦은 역률 보상으로도 사용되며, 비선형 부하에서 발생하는 고조파를 저감하기 위해 리액터에 직렬로 연결하여 사용되기도 한다. 콘덴서는 전압이 증가할 경우 전류도 함께 증가하고, 주파수가 증가할 경우 콘덴서에 흐르는 전류가 증가하기 때문에 전류의 증가는 바로 열의 증가로 콘덴서 절연에 스트레스로 작용하여 고장의 원인을 제공할 수 있다. 본 연구에서는 콘덴서에 인가되는 전압의 크기와 주파수를 변화시킬 경우 콘덴서에서 발생하는 열을 열화상 카메라로 측정하여 외부 및 내부에서의 온도분포를 분석하였다. 측정결과 전압과 주파수가 증가할 경우 콘덴서에서 열이 매우 높게 분포함을 확인할 수 있었다.

  • PDF

Analysis for Thermal Distribution of Low-voltage Condenser by the Variance of Voltage & Frequency (전압 및 주파수 변화에 따른 저압 콘덴서 열 분포 해석)

  • Kim, Jong-Gyeum
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.4
    • /
    • pp.43-49
    • /
    • 2010
  • Power capacitor has been used to compensate for the low power factor of inductive load and to reduce harmonics generated by the power conversion device with reactor. The increase of voltage and current and thermal generation are extremely hard on the life of condenser. Current will be increased, provided that voltage and frequency of condenser increase also. The increase of voltage and frequency justly extends thermal generation. Both act on insulation stress and can afford to premature fault In this paper, we measured thermal distribution of condenser with infrared rays camera in case of variance of voltage and frequency. We were assured that the increase of voltage and frequency produces high heat and exceedingly shortens the life of condenser.

Experimental Verification of Heat Sink for FPGA Thermal Control (FPGA 열제어용 히트싱크 효과의 실험적 검증)

  • Park, Jin-Han;Kim, Hyeon-Soo;Ko, Hyun-Suk;Jin, Bong-Cheol;Seo, Hak-Keum
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.9
    • /
    • pp.789-794
    • /
    • 2014
  • The FPGA is used to the high speed digital satellite communication on the Digital Signal Process Unit of the next generation GEO communication satellite. The high capacity FPGA has the high power dissipation and it is difficult to satisfy the derating requirement of temperature. This matter is the major factor to degrade the equipment life and reliability. The thermal control at the equipment level has been worked through thermal conduction in the space environment. The FPGA of CCGA or BGA package type was mounted on printed circuit board, but the PCB has low efficient to the thermal control. For the FPGA heat dissipation, the heat sink was applied between part lid and housing of equipment and the performance of heat sink was confirmed via thermal vacuum test under the condition of space qualification level. The FPGA of high power dissipation has been difficult to apply for space application, but FPGA with heat sink could be used to space application with the derating temperature margin.

A study on the electric power recovery in generator load test (부하 시험 발전기 전력회수에 관한 연구)

  • Lee, Myoungho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.4
    • /
    • pp.403-408
    • /
    • 2014
  • Lots of electric power has been wasted through the load bank usually in the container boxes during the generator load test of the ship and offshore plant in the new ship building. Therefore in this research, the quantity of wasted electric power through generator load test under construction was investigated on big shipbuilding yard and quantity of electric power that can be recovered is analyzed when produced electric power during the generator load test is connected to KEPCO Grid, according to laboratory's experiment result where recovers electric power produced from small generator connected to KEPCO Grid.

A channel-coding based SS-PLC system using new measured impluse noise model (새로운 실측 임펄스 잡음 모델을 반영한 채널코딩 기반의 대역확산 전력선 통신시스템)

  • Moon, K.H.;Shin, M.C.;Lee, J.J.;Choi, S.Y.;Park, K.W.;Cha, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.72-74
    • /
    • 2005
  • 전력선통신은 현재 홈 네트워크 및 검침기술과 같은 다양한 분야에서 활발하게 응용이 되고 있는 기술이다. 이러한 전력선 통신을 위한 전송선로는 통신을 위한 정보데이터를 전송하는 기능과 더불어 선로상의 전력 부하들을 위한 전력 공급용으로서의 용도도 가지고 있다. 그러므로 선로상의 부하변동은 다양한 형태의 임 펄스 잡음을 야기 시키고 이러한 임펄스성 잡음은 전송 데이터에 군집에러를 발생시킴으로써 통신성능을 크게 열화 시키는 요인이 되고 있다. 따라서 효율적인 전력선 통신시스템을 위해서는 전력 선로상의 임펄스 잡음의 특성을 명확히 분석하고, 그에 따른 에러제거기법을 적용하는 것이 필수적이라고 할 수 있다. 이러한 관점에서 본 논문에서는 새롭게 가정의 전력 선로에 연결되는 부하들의 동작 및 변동에 따른 임펄스 잡음 특성을 다양한 부하의 유형별로 디지털 하드웨어를 이용하여 실측 및 분류한 후, 새롭게 도출한 임펄스 잡음 모델을 기반으로 순방향 오류정정방식(FEC;Forward Error Correction)인 컨벌루션 부호화(Convolution Coding) 및 인터리빙(Interleaving) 방식을 가미하여 시스템의 비트오율 개선효과를 확인하였다. 본 논문에서 수행된 새로운 실측기반의 임펄스 잡음이 반영된 채널부호화 방식에 의한 성능평가 결과는 향후 홈네트워크기반의 전력선 통신시스템의 실질적인 참고데이터로서 유용하게 활용되리라 기대된다.

  • PDF

Development of Heat Dissipation Measuring System for 1.2-kW BLDC Motor (1.2kW 급 BLDC 모터의 열 발산 측정 시스템 개발)

  • Lee, Injun;Ye, Jungwoo;Lee, Daehun;Hwang, Pyung;Shim, Jaesool
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.11
    • /
    • pp.1423-1428
    • /
    • 2013
  • In this study, a heat dissipation measurement system is developed to analyze a 1.2-kW BLDC motor. It is important to check the temperature of the motor because an increase in temperature causes problems in the motor insulations, which in turn influences the motor life. A generator for a vehicle is installed to set up a load. We changed the load from 165 to 495 W. While the rpm varies from 2000 to 4000 under various load conditions, the changes in temperature were measured for the operating period by using a thermocouple. The results of experiments conducted under natural convection conditions suggest that the temperature was not stationary with the rpm, load, and coil of the motor and it kept increasing over $120^{\circ}C$. However, under forced convection conditions, the temperature stationarily reached $84^{\circ}C$ after 4000 s. The difference between the maximum and the minimum temperatures was $10-26^{\circ}C$ with an increase in the rpm and load. The orders of high temperature were as follows: motor coil (Ch#1), side of motor surface (Ch#5), inside of motor cap (Ch#2), upper side of motor surface (Ch#4), and inner wall of the motor (Ch#3).