• Title/Summary/Keyword: 역치하

Search Result 422, Processing Time 0.027 seconds

Study of threshold and opacity in three-dimensional CT volume rendering of oral and maxillofacial area (구강악안면영역의 3차원 CT 영상 재형성시 역치 및 불투명도에 대한 연구)

  • Choi, Mun-Kyung;Lee, Sam-Sun;Huh, Kyung-Hoe;Yi, Won-Jin;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.39 no.1
    • /
    • pp.13-18
    • /
    • 2009
  • Purpose: This study was designed to determine a proper threshold value and opacity in three-dimensional CT volume rendering of oral and maxillofacial area. Materials and Methods: Three-dimensional CT data obtained from 50 persons who were done orthognatic surgery in department of oral and maxillofacial radiology of Seoul National University retrospectively. 12 volume rendering post-processing protocols of combination of threshold(100HU, 150HU, 221HU, 270HU) and opacity (58%, 80%, 90%) were applied. Five observers independently evaluated image quality using a five-point range scale. The results were analyzed by receiver operating characteristic curves, ANOVA and Kappa value. And three oromaxillofacial surgeons chose the all images that they thought proper clinically in the all of images. Results: Analysis using ROC curves revealed the area under each curve which indicated a diagnostic accuracy. The highest diagnostic accuracy appear with 100HU and 58% opacity. and the lowest diagnostic accuracy appear with 221HU and 58% opacity that are being used protocol in department of oral and maxillofacial radiology of Seoul National University. But, no statistically significant difference was noted between any of the protocols. And the number of proper images clinically that chosen by three oromaxillofacial surgeons is the largest in the cases of protocol 8 (221HU, opacity 80%) and protocol 11 (270HU, opacity 80%) in one after the other. Conclusion: Threshold and opacity in volume rendering can be controled easily and these can be causes of making an diagnostic accuracy. So we need to select proper values of these factors.

  • PDF

Diagnosis of Ictal Hyperperfusion Using Subtraction Image of Ictal and Interictal Brain Perfusion SPECT (발작기와 발작간기 뇌 관류 SPECT 감산영상을 이용한 간질원인 병소 진단)

  • Lee, Dong Soo;Seo, Jong-Mo;Lee, Jae Sung;Lee, Sang-Kun;Kim, Hyun Jip;Chung, June-Key;Lee, Myung Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.1
    • /
    • pp.20-31
    • /
    • 1998
  • A robust algorithm to disclose and display the difference of ictal and interictal perfusion may facilitate the detection of ictal hyperfusion foci. Diagnostic performance of localizing epileptogenic zones with subtracted SPECT images was compared with the visual diagnosis using ictal and interictal SPECT, MR, or PET. Ietal and interictal Tc-99m-HMPAO cerebral perfusion SPECT images of 48 patients(pts) were processed to get parametric subtracted images. Epileptogenic foci of all pts were diagnosed by seizure free state after resection of epileptogenic zones. In subtraction SPECT, we used normalized difference ratio of pixel counts(ictal-interictal)/interictal ${\times}100%$) after correcting coordinates of ictal and interictal SPECT in semi-automatized 3-dimensional fashion. We found epileptogenic zones in subtraction SPECT and compared the performance with visual diagnosis of ictal and interictal SPECT, MR and PET using post-surgical diagnosis as gold standard. The concordance of subtraction SPECT and ictal-interictal SPECT was moderately good(kappa=0.49). The sensitivity of ictal-interictal SPECT was 73% and that of subtraction SPECT 58%. Positive predictive value of ictal-interictal SPECT was 76% and that of subtraction SPECT was 64%. There was no statistical difference between sensitivity or positive predictive values of subtraction SPECT and ictal-interictal SPECT, MR or PET. Such was also the case when we divided patients into temporal lobe epilepsy and neocortical epilepsy. We conclude that subtraction SPECT we produced had equivalent diagnostic performance compared with ictal-interictal SPECT in localizing epileptogenic zones. Additional value of these subtraction SPECT in clinical interpretation of ictal and interictal SPECT should be further evaluated.

  • PDF

Change of Skin Temperature of Workers Using Vibrating Tools in Anthracite Mines (진동공구 사용근로자의 피부온도 변화)

  • Roh, Jae-Hoon;Moon, Young-Hahn;Shin, Dong-Chun;Cha, Bong-uk;Cho, Soo-Nam
    • Journal of Preventive Medicine and Public Health
    • /
    • v.21 no.2 s.24
    • /
    • pp.357-364
    • /
    • 1988
  • By implementing epoch-making policies for industrial promotion, the national economy has made a remarkable development. As a result of such economic growth, industrial accidents and occupational diseases have become a serious problem in Korean society. In the presidential order for the execution of the Korean Labor Standard Law, neuritis and other diseases stemming from health impairments due to vibrations in industrial processes are designated to be dealt with as vibration diseases. In the case of vibration disease, industrial accident compensation is not effectively paid. In order to investigate the vibration hazards of rock-drill operation, the authors studied the subjective symptoms and performed physical function tests on a total of 79 persons (vibration exposed group) who used rock-drills, and 39 persons (control group) who did not use rock-drills at anthracite mines. The results of the physical function test were as follosws : 1. The right hand was more affected by white finger than the left hand. 2. Independent variables such as duration of rock-drill operation, age, drinking and smoking were indentified as statistically significant factors for the occurrence of white finger. 3. In the pain sense threshold, the group with Raynaud's phenomenon showed a statistically higher level than that of the control group. 4. The skin temperature of the group with Raynaud's phenomenon was lower than that of the control group. The recovery time of skin temperature aftr cooling was delayed compared with the value of the control group.

  • PDF

Fragrance, Chemical Composition and Toxicity of the Essential Oil in Erect Bur-marigold (Bidens tripartita L.) (가막사리 (Bidens tripartita L.) 정유의 향취, 화학성분 및 세포독성)

  • Yun, Mi-Sun;Yeon, Bo-Ram;Cho, Hae-Me;Lee, Sa-Eun;Jhoo, Jin-Woo;Jung, Ji-Wook;Park, Yu-Hwa;Kim, Song-Mun
    • Korean Journal of Weed Science
    • /
    • v.32 no.3
    • /
    • pp.195-203
    • /
    • 2012
  • The essential oil was extracted by steam distillation from the aerial part of erect bur-marigold (Bidens tripartita L.), one of the noxious weed in paddy field. The composition of the essential oil was analyzed by gas chromatography-mass spectrometry. The fragrance of the essential oil was green, herbal, oily, spicy. There were 42 constituents in the essential oil:17 hydrocarbons, 6 alcohols, 6 acetates, 5 N-containing compounds, 3 ethers, 3 ketones, 1 lactone and 1 S-containing compound. Major constituents were ${\alpha}$-phellandrene (22.50%), ${\alpha}$-pinene (22.21%), 2,4-dimethyl (2,5-dimethylphenyl) methyl ester benzoic acid (15.11%), limonene (10.66%), ${\beta}$-pinene (35.43%), and ${\beta}$-cubebene (5.27%). The $IC_{50}$ value in MTT assay using HaCaT keratinocyte cell line was 0.018%. However, attachment of patch with 0.1% of the erect bur-marigold essential oil for 24 hr did not show any skin toxicity. Overall results of this study suggest that the essential oil of erect bur-marigold could be used as a source for the development of perfumery industrial products.

A Study on the Characteristics of Smartphone Camera as a Medical Radiation Detector (의료 방사선 검출기로써 스마트폰 카메라의 특성에 관한 연구)

  • Kang, Han Gyu;Kim, Ho Chul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.5
    • /
    • pp.143-151
    • /
    • 2016
  • The aim of this study is to investigate the optimal algorithm to extract medical radiation induced pixel signal from complementary metal-oxide semiconductor (CMOS) sensors of smartphones camera. The pixel intensity and pixel number of smartphone camera were measured as the X-ray dose was increased. The front camera of the smartphone camera has low noise property and excellent dose response as compared to the back camera of the smartphone. The indirect method which uses scintillation crystal in front of the smartphone camera, couldn't improve the X-ray detection efficiency as compared to the direct method which does not use any scintillator in front of the smartphone camera. When we used the algorithm which employing threshold level on the pixel intensity and pixel number, the dose linearity was more higher for the pixel intensity rather for the pixel number. The use of pixel intensity of Y color component which represents the grey scale, would be efficient in terms of the radiation detection efficiency and reducing the complexity of the image processing. We expect that the radiation dose monitoring can be managed effectively and systematically by using the proposed radiation detection algorithm, thus eventually will contribute to the public healthcare.

A Study of Acoustic Masking Effect from Formant Enhancement in Digital Hearing Aid (디지털 보청기에서의 포먼트 강조에 의한 마스킹 효과 연구)

  • Jeon, Yu-Yong;Kil, Se-Kee;Yoon, Kwang-Sub;Lee, Sang-Min
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.5
    • /
    • pp.13-20
    • /
    • 2008
  • Although digital hearing aid algorithms have been developed to compensate hearing loss and to help hearing impaired people to communicate with others, digital hearing aid user still complain about difficulty of hearing the speech. The reason could be the quality of speech through digital hearing aid is insufficient to understand the speech caused by feedback, residual noise and etc. And another thing is masking effect among formants that makes sound quality low. In this study, we measured the masking characteristics of normal listeners and hearing impaired listeners having presbyacusis to confirm masking effect in speech itself. The experiment is composed of 5 tests; pure tone test, speech reception threshold (SRT) test, word recognition score (WRS) test, puretone masking test and speech masking test. In speech masking test, there are 25 speeches in each speech set. And log likelihood ratio (LLR) is introduced to evaluate the distortion of each speech objectively. As a result, the speech perception became lower by increasing the quantity of formant enhancement. And each enhanced speech in a speech set has statistically similar LLR, however speech perception is not. It means that acoustic masking effect rather than distortion influences speech perception. In actuality, according to the result of frequency analysis of the speech that people can not answer correctly, level difference between first formant and second formant is about 35dB, and it is similar to result of pure tone masking test(normal hearing subject:36.36dB, hearing impaired subject:32.86dB). Characteristics of masking effect is not similar between normal listeners and hearing impaired listeners. So it is required to check the characteristics of masking effect before wearing a hearing aid and to apply this characteristics to fitting.

Enhancement of the Early/Precise Diagnosis Based on the Measurement of SUVs in F-18 FDG PET/CT Whole-body Image (F-18 FDG PET/CT 전신 영상에서 SUVs 측정에 기반한 조기/정밀 진단 연구)

  • Park, Jeong-Kyu;Kim, Sung Kyu;Cho, Ihn-Ho;Kong, Eun-Jung;Park, Myeong-Hwan;Cho, Bok-Yeon
    • Progress in Medical Physics
    • /
    • v.24 no.3
    • /
    • pp.176-182
    • /
    • 2013
  • Through this research, we measure the data for several SUVs such as SUVLBM, SUVBW, and SUVBSA using volume of interest in order to enhance the diagnostic level in whole-body image for healthy examinees via F-18 FDG PET/CT. Maximum value, mean value, standard deviation, and threshold value for each SUVs are shown. The measurement of SUVs are carried out with 31 examinees who have taken whole-body examination with F-18 FDG PET/CT from July, 2012 to August, 2012. To secure the preciseness of measurement, we selected 26 healthy examinees as a subject of measurement according to diagnostic view of a nuclear-medical doctor. We see from the measurement of SUVs of PET/CT that the value of SUVBW is hightest and followed by SUVLBM and SUVBSA in turn regardless of the use of contrast media. By comparing the SUVLBM-maximum data for the group used contrast media with those for the group used no contrast media, there found a trend that the measured values increase when the contrast media are used. Among them, liver, aorta, lumbar-5, and Cerebellum exhibit significant difference (p<0.05). We conclude that our data for SUVs would be basic references in overall image interpretation, and hope that the research using VOI would be active.

Efficacy of Lens Shielding Device to Prevent Cataract with Radiotherapy for Orbit or Ocular Adnexal Tumor (안와 및 안부속기 종양의 방사선치료에서 백내장의 예방을 위한 렌즈보호 장치의 효용성)

  • Cho, Jung-Keun;Cho, Hyun-Sang;Han, Tae-Jong
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.12
    • /
    • pp.139-144
    • /
    • 2007
  • Radiotherapy which is the most effective for orbit lymphoma has been used increasingly due to the increase of orbit or ocular adnexal tumor patients. Curative effects and convalescence have been being more satisfied thanks to remarkable development of cancer chemotherapy and medical treatments, but side effects such as cataract, dry eye and retinopathy still break out. Thus, in this study, a Lens Shielding Device (LSD hereafter) was designed to prevent occurring of cataract due to radiation therapy for orbit lymphoma and its efficacy through dosimetry were evaluated. And in this paper, its manufacturing process was also explained. LSD is composed of a cover body covering the lens and a side fixing part supporting the cover body. To measure radiation, the patient therapy conditions were simulated and the measurement of the radiation was conducted with Thermo Luminescence Detector (TLD) and Markus chamber. The average TLD value was 5.7% and the TLD value and Markus chamber value were acquired as 4.2% and 5.1% respectively at 6 mm depth where zero lens center was located. Only 1.5Gy ($300Gy{\times}\;5%$) or 5% of total 30Gy with 9 MeV electron beam is estimated to affect on patient's lens. That is smaller dose than the threshold value of cataract (2GY) or the value (5Gy) that was reported to cause cataract in clinical conditions. Thus, these findings suggest that LSD be very useful for prevention of cataract during radiotherapy for malignant lymphoma of orbit and ocular adnexa. Furthermore, it might be possible to reduce patient's discomfort caused by alien substances and to make it easier to fix the device with customized manufacturing manners.

The Function and Quantitative Somatosensory Correlation Analysis of Temporomendibular Joint according to Forward Head Posture (전방머리자세에 변화에 따른 턱관절 기능 및 정량적 체성감각의 상관분석)

  • Lee, Eun Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.645-651
    • /
    • 2019
  • This study examined the correlation between the forward head posture (FHP), temporomandibular joint disorder (TMD), and temporomandibular joint quantitative somatosensory sensation. This study examined the correlation between the temporomandibular joint function and somatosensory sensation according to the change in FHP after the intervention on the head posture in 62 subjects (22.15 ± 2.56 years) Biofeedback training was administered to the FHP, which was performed 12 times for a total of four weeks. To assess the FHP, the craneovertebral angle (CVA) was examined. The temporomandibular joint (TMJ) function was measured by the Therapeutic Range of Motion Scale and the left and right lateral deviation, and the sensation of vibration threshold was measured to confirm the change in somatic sensation. Multiple regression analysis was performed to confirm the influence of each variable and Pearson's correlation analysis was performed to assess the correlation. Changes in the temporal joint function (p<.001) and somatic sensation (p<.001) were correlated significantly with the changes in CVA. These results show that there is a significant correlation between the frontal head position, TMJ function, and somatosensory sensation. These results provide a new paradigm for the treatment of jaw joints for patients suffering from TMD and provide a basis for the future treatment of the temporomandibular joint.

Characterizing Information Processing in Visual Search According to Probability of Target Prevalence (표적 출현확률에 따른 시각탐색 정보처리 특성)

  • Park, Hyung-Bum;Son, Han-Gyeol;Hyun, Joo-Seok
    • Korean Journal of Cognitive Science
    • /
    • v.26 no.3
    • /
    • pp.357-375
    • /
    • 2015
  • In our daily life, the probability of target prevalence in visual search varies from very low to high. However, most laboratory studies of visual search used a fixed probability of target prevalence at 50%. The present study examined the properties of information processing during visual search where the probability of target prevalence was manipulated to vary from low (20%), medium (50%), to high (80%). The search items were made of simple shape stimuli, and search accuracy, signal detection measures, and reaction times (RTs) were analyzed for characterizing the effect of target prevalence on the information processing strategies for visual search. The analyses showed that the rates of misses increased whereas those of false alarms decreased in the search condition of low target prevalence, whereas the pattern was reversed in the high prevalence condition. Signal detection measures revealed that the target prevalence shifted response criterion (c) without affecting sensitivity (d'). In addition, RTs for correct rejection responses in the target-absent trials became delayed as the prevalence increased, whereas those for hits in the target-present trials were relatively constant regardless of the prevalence. The RT delay in the target-absent trials indicates that increased target prevalence made the 'quitting threshold' for search termination more conservative. These results support an account that the target prevalence effect in visual search arises from a shift of decision criteria and the subsequent changes in search information processing, while rejecting the account of a speed-accuracy tradeoff.