• Title/Summary/Keyword: 역률1

Search Result 162, Processing Time 0.036 seconds

Harmonic Reduction in Three-Phase Boost Converter with Sixth Order Harmonic Injected PWM (6고조파 주입 PWM을 이용한 3상 승압형 컨버터 고조파저감)

  • 이정호;김재문;이정훈;원충연;김영석;최세완
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.2
    • /
    • pp.176-183
    • /
    • 2000
  • In this paper, sixth order hannonic injected PWM for improving‘ input CWTent distortion of single switch t three phase boost converter is presented. Peliodic sixth order hmmonic ${\gamma}$oltage is inj<:ded in the control circuit t to var${\gamma}$ the duty ratio of the converter switch within one switching cycle. In the result, the input phase c currents are forced to track the input voltage and an 해most unity power factor is obtained. Expelimental r results are verified by converter operating at 400V /6kW with three phase 140V ~220V input and by C02 arc w welding machine which was nonlinear load with 3 $\phi$ 220V input.

  • PDF

A Divece for Reducing the Zero phaze Harmonics of Neutral Line of Power Facility (전기수용설비의 중성선 영상분고조파전류저감장치)

  • Kang, Chang-Won;Choi, Gil-Soo;Han, Sung-Bae;Kim, Bum-Soo;Chung, Yeon-Hae;Lee, Ki-Cheol
    • Electric Engineers Magazine
    • /
    • v.228 no.8
    • /
    • pp.43-48
    • /
    • 2001
  • Wide use of non-linear loads such as personal computers, monitors, laser printers, variable speed drives, UPS systems and other electronic equipment have led to harmonics becoming #1 issue in the electrical industry today. Commercial and Industrial building power distribution systems, designed for the old, linear-style loads especially when found in high densities. Some common power system problems include overloaded neutral conductors, overheated distribution transfOlmers, high neutral-to-ground voltage, poor power factor and distortion of the voltage waveform supplying these loads. The power quality problems, particularly high voltage distortion, have been known to cause equipment downtime due to malfunctions and component failure.

  • PDF

Performance Verification of Anti-Islanding of Reactive Power Variation Method using Positive Feedback (정궤환을 이용한 무효전력 변동기반의 단독운전 방지 성능 검증)

  • Jo, Jongmin;An, Hyunsung;Park, Jiho;Cha, Hanju
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.141-143
    • /
    • 2018
  • 본 논문은 계통연계형 인버터의 단독운전 방지를 위해 정궤환을 이용한 무효전력 변동기법을 제안하였으며, 구현 및 실험을 통해 단독운전 방지 성능을 검증하였다. PCC 지점에는 양호도($Q_f$) 2.5의 특성을 갖는 3상 RLC 부하가 연결되며, 부하 공진주파수는 60Hz로 설정하였다. 무효전력 변동기법은 일정 크기로 주입되는 무효분과 주파수 편차를 이용한 정궤환으로부터 공급되는 무효분으로 구성된다. 계통연계 운전 시에는 일정한 무효전력 성분만이 공급되며 역률은 0.9975이다. 단독운전 발생 시, 일정 무효전력 때문에 변화된 PCC 주파수와 계통 정격주파수 간의 편차는 정궤환 성분을 활성화하고, 증가된 무효전력에 의한 PCC 주파수 변화를 검출하여 단독운전을 판단한다. 1.7kW 3레벨 T-타입 인버터를 통해 단독운전 방지 성능을 실험하였으며, 검출시간은 각각 53ms, 150ms로써 우수한 성능을 검증하였다.

  • PDF

Modeling and Development of control algorithm for Grid-Connected MW ESS (계통연계형 MW급 ESS의 모델링 및 제어알고리즘 개발)

  • Jung, Se-Hyung;Kim, Joo-Ha;Jung, Ah-Jin;Yang, Seok-Hyun;Park, Sung-Youl;Choi, Se-Wan;Kang, Byung-Kwan;Lee, Chung-Woo;Yoo, An-No;Kim, Hee-Jung
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.65-66
    • /
    • 2014
  • 본 논문에서는 부하평준화를 통한 전기요금 절감효과, 무효전력 보상을 통한 역률 개선 및 비상부하 전원공급을 위한 독립운전 기능을 갖는 MW급 ESS에서 PCS뿐 아니라 배터리, 변압기, 각종부하 및 디젤발전기 등 계통 내 구성 요소들을 실제 사양 및 데이터를 기반으로 모델링하였다. 또한 1MW PCS를 위한 유 무효전력, CC-CV 충전 및 독립운전 제어알고리즘을 개발하였으며 시뮬레이션 및 축소시험을 통해 본 논문의 타당성을 검증하였다.

  • PDF

A study on the haromnic attenuation of the BF Converter (BF 컨버터의 고조파 감쇠에 관한 연구)

  • 최태섭;안인수;임승하;사공석진
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.4
    • /
    • pp.8-15
    • /
    • 2000
  • In this paper, we realize the active PFC(Power Factor Correction) system of BF(Boost Forward) converter with PWM-PFM(Pulse Width Modulation-Pulse Frequency Modulation) control technique to control DC output voltage, to remove the noise like harmonics at output voltage, and to control the input current with sinusoidal wave synchronized by the source voltage.To achieve the desired load voltage and improved PFC, we first implement current shaping control at the inverting stage and make the converted output DC voltage with forward converter. After making the ratio of output voltage to current as 50V/1A and the duty ratio greater than 0.5. When input voltage is 30V and boost inductance is 1.1mH. we control the voltage changing rate according to the variation of load resistance using a PWM-PFM control technique. And finally we prove experimentally, we attenuated its harmonics and improved PF up to 0.96 using the current shaping technique.

  • PDF

Design and Application of PFC Direct Drive Inverter for LCD-TV (LCD-TV용 PFC Direct 구동 인버터의 설계와 응용)

  • Ko, Tae-Seok;Jung, Yong-Joon;Hong, Sung-Soo;Han, Sang-Kyu;Jang, Byung-Jun;Jang, Young-Su;Han, Seung-Ho;Roh, Chung-Wook
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.52-59
    • /
    • 2010
  • The conventional CCFL (Cold Cathode Fluorescent Lamp) inverter used in the backlight unit for LCD-TV, composed of the three power stage, can degrade the whole power conversion efficiency. In this paper, a novel scheme to drive the CCFL, composed only of the two power stage without using a dc/dc power stage, is proposed to enhance the whole power conversion efficiency. By adopting the proposed "4-in-1 Transformer", the current balance and the simultaneous ignition among the four CCFL lamp are assured with the one inverter circuit. The proposed scheme features the simple circuit structure, which can save the volume and the cost in the LCD backlight unit. Design considerations are discussed and design procedures are derived. Experimental results of the proposed scheme for 40" LCD-TV are presented to confirm the theoretical analysis.

Effect of Harmonic Generation and Countermeasures (고조파발생에 따른 영향과 대책 연구)

  • Baek, Dong-Hyun
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.91-97
    • /
    • 2015
  • Skyscrapers, large business buildings, and IT consumers use many appliances, and the electrical power stems can cause fires by overheating. This can result in damaged capacitors, lost data, rising ground potential, and communication obstacles from linear or nonlinear high frequency. To make sure of that we investigated 7 spots of a building, among which 6-spots were fair but the other one needed high frequency control. Spots 3, 6, and 7 needed diagnostic workup, and spots 2, 3, and 5 considered 5 high frequency currents. A phase is all of good but the high frequency current is greater than the standard level except for spot 1. As a result, a zigzag transformer or active filter needs to be installed, and the efficiency needs to be upgraded by investigating load unbalance factors and power factors.

Single-stage Power Factor Corrected AC-to-DC Converter for sustain/reset Driving Power Supply of PDP TV (PDP TV의 sustain/reset 구동전원 공급을 위한 1단방식의 역률보상형 AC-to-DC 컨버터)

  • Kang, Feel-Soon;Park, Jin-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.2
    • /
    • pp.282-289
    • /
    • 2008
  • To improve the efficiency of PDP TV, it should minimize the power losses transpired during AC-to-DC power conversion and PDP driving process. Generally the input power supply for PDP driving employes a two-stage power factor corrected converter, and it needs additional DC-to-DC converters to supply driving power for reset circuit ed sustain driver, which has high power consumption. However, such a circuit configuration has a difficulty for the PDP market requires low cost. To alleviate this problem, a new circuit composition is presented. It integrates input power supply with reset and sustain driver in a single power stack The input power supply of the proposed circuit has a single-stage structure to minimize power conversion loss, and it directly supplies power to the sustain driver so as to reduce the system size and cost.

A Research into a Device for Measuring the Electric Power Quality and the Harmonic Frequency (전력 품질 및 전력 고조파 측정 장치에 관한 연구)

  • Oh, Kyutae;Yoo, Youngkil
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.10
    • /
    • pp.233-239
    • /
    • 2012
  • The harmonic frequency occurred in a power system causes errors and failures of equipments such as motors, and an unnecessary power consumption. The fundamental countermeasure for the harmonic frequency is to eliminate the cause of the harmonic frequency. This paper describes about making the device to figure out the cause in real time, verifying the operation of the device, and utilizing it to various power quality measurements. The power usually has the line frequency between 45Hz and 66Hz. In this research, the number of the harmonic frequencies which can be analysed inside the 2.8kHz bandwidth, the filter bandwidth of ADE7880, is 2800/f, and the maximum is 2800/45 = 63. The maximum order of the harmonic frequency in Korea, which has the line frequency of 60Hz, was measured as 2800/60 = 46th. Also, the accuracy of the voltage, current, and power measurement had the error within 0.1%, confirming that it is very precise.

Boost $1\Psi$ converter of high efficiency by partial resonant switching using lossless snubber (무손실 스너버를 이용한 부분공진 스위칭에 의한 고효율 승압형 단상 컨버터)

  • 서기영;곽동걸;전중함;이현우
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.4
    • /
    • pp.315-322
    • /
    • 1998
  • Power conversion system must increase switching frequency in order to achieve small size, light weight and low noise. However, the switches of converter are subject to high switching power losses and switching stresses. As a result, the power system has a lower efficiency. In this paper, the authors propose an AC-DC boost converter of high efficiency by partial resonant switching mode. The switching devices in the proposed circuit are operated with soft switching and the control technique of those is simplified for switch to drive in constant duty cycle. The partial resonant circuit makes use of a inductor using step up and a condenser of loss-less snubber. Besides, by regenerating energy, that is charged in a loss less snubber condenser of a snubber adopted to a common circuit, toward an input source part, this circuit can get increased efficiency. as merit. The result is that the switching loss is very low, the efficiency and power factor of system is high. The proposed converter is deemed the most suitable for high power applications where the power switching devices are used.

  • PDF