• Title/Summary/Keyword: 역률1

Search Result 162, Processing Time 0.019 seconds

Small-Signal Model for Controlled On-Time Boost Power Factor Correction Circuit (연속-불연속 경계모드에서 동작하는 역률보상회로를 위한 소신호 모델)

  • Kang, Yong-Han;Seo, Bo-Hyeok
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.141-143
    • /
    • 1998
  • A new small-signal model for the controlled on-time boost Power factor correction (PFC) circuit is Presented. The proposed small-signal model is valid up to high frequencies ever 1kHz. IF to remove the low-frequency ripple from the output a 120Hz notch filter is used the proposed model can be used for the control design of the PFC circuit to improve the dynamics of the output voltage. The accuracy of the model is confirmed by comparing the experimental results with the simulational result.

  • PDF

A Current Sensor-less Bridgeless CCM Single-Stage PFC Converter with Semi-Active Rectifier (Semi-Active Rectifier를 적용한 센서리스 단일단 브리지리스 PFC 컨버터)

  • Naradhipa, Adhistira M.;Kang, Suhan;Hai, Tran;Sagpazar, Nur Banu;Choi, Sewan
    • Proceedings of the KIPE Conference
    • /
    • 2018.11a
    • /
    • pp.59-61
    • /
    • 2018
  • 본 논문에서는 입력전류를 센싱 받지 않아도 역률 보상을 하는 새로운 단일단 브리지리스 AC-DC컨버터를 제안한다. 제안하는 컨버터의 스위치는 전구간에서 ZVS(Zero Voltage Switching) 턴 온을 성취하며, 다이오드는 전구간에서 ZCS(Zero Current Switching) 턴 오프를 성취한다. 제안하는 컨버터의 넓은 범위의 출력전압 제어와 간단한 전력 제어를 위해 SDAB(Semi-Dual Active Bridge)기반의 모듈레이션 기법을 적용하였다. 1kW급 50kHz의 스위칭 주파수를 갖는 시작품을 통해 본 논문의 타당성을 검증하였다.

  • PDF

A Study on T5 28W Fluorescent Lamp Ballast Using a Piezoelectric Transformer and One-chip Microcontroller (One Chip Microcontroller와 압전변압기를 이용한 T5 28W 형광등용 전자식 안정기에 관한 연구)

  • 황락훈;류주현;장은성;조문택;안익수;홍재일
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.1
    • /
    • pp.70-79
    • /
    • 2003
  • In this paper, T5 28-watt fluorescent lamp ballast using a piezoelectric transformer is fabricated and its characteristic is investigated. Developed electronic ballast is composed of basic circuits and blocks, such as rectifier part, active power factor corrector part, frequency oscillation part using microcontroller and feedback control, piezoelectric transformer and resonant half bridge inverters. The fabricated ballast uses to variable frequency methode in external so exciting that the frequency of piezoelectric transformer could be generated by voltage control oscillator using microcontroller(AT90S4433). The current of fluorescent lamp is detected by feedback control circuit. The signal of inverter output is received using Piezoelectric transformer, and then its output transmitted to fluorescent lamp. Traditional electromagnetic ballasts operated at 50-60Hz have been suffered from noticeable flicker, high loss, large crest factor and heavy weight. A new electronic ballast is operated at high frequency about 75kHz, and then Input power factor, distortion of total harmonic and lamp current crest factor are measured about 0.9!35, 12H and 1.5, respectively Accordingly, the traditional ballast is by fabricated electronic ballast using piezoelectric transformer and voltage control oscillator because of its lighter weight, high efficiency, economic merit and saving energy.

A Study on the Development of Ignition Trans applied to Gas Boiler (가스보일러에 적용되는 점화 트랜스 개발에 관한 연구)

  • Lee, Ho-kyun;Kim, Jang-Won;Park, Jung-cheul
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.6
    • /
    • pp.467-472
    • /
    • 2021
  • In this paper, the ignition trans used in the gas boiler was produced to measure current, power factor, and power consumption. As a result of measuring the power factor, the self-made ignition trans was higher than that of foreign products and the power consumption was lower. The ignition gap was fixed to 2 m, and when the ignition rod length was 30cm, 500cm, and 1000cm, it was measured as 3.45A, 14.5A, and 16.2A. When the ignition gap was fixed to 4mm and the ignition rod length was 30cm, 500cm, and 1000cm, it was measured as 2.8A, 10.1A, and 13.2A. When the ignition gap was fixed at 6mm and the ignition rod length was 30cm, 500cm, and 1000cm, it was measured as 2.73A, 10.2A, and 32.6A. When the ignition gap was fixed at 8 mm and the ignition rod length was 30 cm, 500cm, and 1000cm, it was measured as 3.13A, 9.37A, and 21.4. The ignition gap was fixed at 10 mm, and when the ignition rod length was 30cm, it was measured as 3.4A, 14.4 A, and 25.6A. In conclusion, as the length of the ignition rod increased, the current also increased.

Implementation of a High-Power-Factor Single-Stage Electronic Ballast for fluorescent lamps (단일전럭단을 갖는 고역율 형광등용 전자식 안정기 구현)

  • 서철식;박재욱;김해준;김동희
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.1
    • /
    • pp.1-9
    • /
    • 2003
  • In this paper, prototype of high-power-factor single-stage electronic ballast for fluorescent lamp is designed and implemented. A new low cost single stage high power factor electronic ballast for fluorescent lamps is based on integration of two-boost converter and LC type high frequency resonant inverter. The proposed ballast is combined by simple construction, because full bridge rectifier diode is eliminated and simple control circuit is applied. Boost converter operate in the voltage of positive and negative half cycle respectively at line frequency (60㎐), operation in discontinuous conduction mode performs high power factor. The experimental results show the good performance as PF 0.99, THD 15.4%, and CF 1.65 at output 63.5〔W〕.

A study on the power factor improvement of Wind Turbine Generation System at Haeng-Won in Jeju (제주 행원 풍력 발전 시스템의 역률 개선에 관한 연구)

  • Park S.G.;Kim J.W.;Kang G.B.;Kim E.H.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.375-378
    • /
    • 2003
  • This paper presents a study on the power factor improvement of the Wind turbine Generation System(WTGS) at Haeng-won wind farm in Jeju Island. Vestas WTGS named V47 as a model system is selected in this paper, and has 660 kW Power ratings. In this system, power factor correction is controlled by the conventional method with power condenor bank. So, model system at Haeng-won wind farm has very low power factor in the area of low wind speed, which is from 4 m/s to 6 m/s. This is caused by the power factor correction using power condenser bank To improve the power factor in the area of low wind speed, we used the static var compensator(SVC) using current controlled PWM power converter by IGBT switching device. finally, to verify the profosed method, the results of computer simulation using Psim program are presented to support the discussion.

  • PDF

Operation Algorithm of Battery Energy Storage System (BESS) for Saving Electric Charges (전기요금 절감 측면에서 에너지저장시스템의 운전알고리즘)

  • 김응상
    • Journal of Energy Engineering
    • /
    • v.8 no.4
    • /
    • pp.519-524
    • /
    • 1999
  • this paper proposes the operation algorithm of 1MW class Battery Energy Storage System(BESS) installed at the extra-high voltage customer. The objective of the proposed algorithm is to reduce electric charges during the operation of the BESS interconnected to power system. This paper simulates the electric charges in 1998 considering Season and Time of Use Rate and Power Factor in the assumption that electricity demand in 1998 is the same amount of that in 1997 and shows the saving of about 40 million won in the total electric charges. The results comparing the real electric charges of June. July and August in 1997 with that in 1998 show that the implementation of the proposed algorithm could significantly reduce electric charges during the operation the BESS.

  • PDF

Development of a 40kV, 300us, 200Hz Solid-State Pulsed Power Modulator (40kV, 300us, 200Hz 반도체 스위치 기반 펄스 전원 장치 개발)

  • Yu, Chan Hun;Jang, Sung Roc;Kim, Hyoung Suk;Appiah, Gideon Nimo;Ryoo, Hong Je
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.167-168
    • /
    • 2016
  • 본 논문은 고효율 반도체 기반 펄스 전원 장치 개발에 대해 기술한다. 개발 된 펄스 전원장치는 출력 전압 1-40kV, 펄스 반복율 1-200Hz, 펄스폭 1-300us, 정격 출력 50kW의 사양을 가지고 있다. 제안하는 펄스 전원 장치는 크게 출력 커패시터를 충전하여 고전압을 만드는 충전기 부분과 48개의 IGBT가 직렬로 연결되어 펄스를 만들어 내는 펄스 제네레이터 부분으로 나누어져 있다. 펄스 제네레이터는 파워셀 기반으로 구성되어, IGBT간의 전압 밸런싱 및 IGBT의 동기구동 실패시에 신뢰성 있는 동작을 할 수 있다는 장점을 가지고 있다. 또한, 제안된 펄스 전원 장치는 새로운 게이트 구동회로를 사용하여 기존에 사용하던 풀다운 저항을 제거하고, 빠른 펄스 하강 시간을 달성 하였다. 개발된 펄스 전원장치로 실험을 수행한 결과, 커패시터 충전기는 최대 충전효율 95% 및 역률 96%를 나타냈으며, 펄스 제너레이터는 게이트 구동회로가 안정적으로 동작하며 최대 40kV, 300us의 펄스를 $2k{\Omega}$ 부하에 인가 가능함을 확인하였다.

  • PDF

Development of a Electrical Converter for Tidal-Current Power Plant with 1.2MW Doubly-fed Induction Generator (조류발전용 1.2MW 권선형유도발전기 제어를 위한 전력변환장치 개발)

  • Park Jungwoo;Lee Kiwook;Kim Dongwook;Yum Kidai;Lee Kwangsoo;Park Jinsoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.520-523
    • /
    • 2005
  • 국내에서 대체에너지 공급 비율을 보면 청정에너지로 분류할 수 있는 태양열에너지, 태양 광 에너지, 풍력에너지를 모두 합하여 대체에너지의 $10\%$이하이며, 대체에너지 비율의 $90\%$ 이상을 폐기물로부터 얻은 에너지가 차지하고 있는 실정이다. 신재생에너지원에는 여러 종류가 있지만 해양에너지원에 대해 대상을 설정하고 이에 대한 부존량을 살펴보면 진도 주변의 해역에서 조류발전 부존량이 약 362만 kW가 되며, 시화호와 새만금 등지에서의 조력발전 부존량이 650만 kW, 동해안 후포 연안을 비롯한 파력발전 부존량이 20만kW가 되는 것으로 알려져 있다. 이에 따라 해양에너지를 실용화하기 위한 연구가 국내외에서 연구되고 있다. 본 논문은 권선형유도발전기를 갖는 조류발전 시스템을 대상으로 연구한 결과로 권선형유도발전기를 제어하기 위한 전력변환장치 개발과 관련한 내용이다. 신재생에너지원이 발전 단가 측면에서 경제성을 갖기 위해서 발전기 용량은 5MW 급까지 대용량화되어 있는 단계이지만 국내에서는 아직 MW급 이상이 되는 권선형 유도발전기와 권선형 유도발전기를 제어하는 전력변환장치에 대한 연구 실적이 없는 상황이다 이에 본 논문에서는 1MW급의 권선형유도발전기에 대한 개발 사례를 소개하면서 유효전력제어, 역률제어, 계통연계방법, 그리고 운전 속도에 따라 변동되는 회전자측에서의 피상전력 특성 등을 제시하고자 한다.

  • PDF

Operation Characteristic of Single-phase PFC converter with 1-switch Voltage Doubler Strategy (단일 스위치 배전압 방식의 단상 PFC 컨버터의 동작 특성)

  • Ku, Dae-Kwan;Ji, Jun-Keun;Cha, Guee-Soo;Lim, Seung-Beom;Hong, Soon-Chan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.561-568
    • /
    • 2011
  • This paper describes the operation characteristic of a single-phase PFC converter with 1-switch voltage doubler strategy for single-phase double-conversion UPS. A single-phase PFC converter with 1-switch voltage doubler strategy needs a diode bridge and one bidirectional active switch. Thus it is possible to reduce the material cost. However, the study results of operation characteristic and controller design has not been known after the converter circuit was proposed. For the performance evaluation of PFC converter, single-phase 3kVA double-conversion UPS was tested. The performance of PFC converter is experimentally confirmed with followings - input current reference traking, input power factor correction.