• Title/Summary/Keyword: 여성 인체모형

Search Result 11, Processing Time 0.024 seconds

Application of Human Engineering Design Approach in Female Garments (여성의류에 있어 인간공학응용사례)

  • 이승경;윤창규
    • Journal of the Ergonomics Society of Korea
    • /
    • v.1 no.1
    • /
    • pp.12-16
    • /
    • 1982
  • 한국여성의 체위에 맞는 의류를 개발하기 위하여 인체계측과 Moire 사진촬영법을 이용하여 체위와 체형조사를 실시하였으며 몸매에 대한 의식조사를 통하여 한국여성이 이상적으로 생각하는 몸매를 조사하였다. 이러한 결과를 바탕으로 연령과 체형에 따른 B.P (beautiful proportion)을 구할수 있었으며 b.P에 따른 인체모형(dummy)를 제작하여 실제생산에 사용하고 있다. 아울러 새로운 형태의 크기 (size) 표시방법을 개발함으로써 소비자가 좀더 쉽게 자기 몸에 맞는 의류를 선택 할 수있도록 하였다.

  • PDF

A Study on Protection of Rear Submarine of 5th percentile Female Dummy (5th%ile 여성 인체모형 뒷좌석 서브마린 방지에 대한 연구)

  • Kim, Hong Gyu;Yum, Sun Ill;Jin, Wook
    • Journal of Auto-vehicle Safety Association
    • /
    • v.9 no.3
    • /
    • pp.13-18
    • /
    • 2017
  • Since 2015, Euro-NCAP and C-NCAP have enhanced regulation on submarine of rear female passenger. This submarine regulation is a big obstacle to achieve the highest level crash performance. So the objective of this study is to develop new technical way to protect rear female passenger against submarine. In this study, we figured out how design factors of seatbelt affect submarine of rear female passenger by sled test. And we verified that rear passenger submarine can be improved by increasing intersection angle of seatbelt anchor and rotation amount of seatbelt buckle. Based on these results, this paper proposes a new invention of seatbelt buckle and anchor that can improve rear passenger submarine. One is seatbelt buckle that can be detached from stopper to prevent rotation and the other is seatbelt anchor that can be changed the structure so as to incline forward during crash. Finally we proved that submarine of rear female passenger can be improved by the effectiveness of new inventions.

Development of Bodice Dress Forms by Body Types for Women in Thirties Applying 3D Body Scan Data (3D 인체 스캔 데이터를 활용한 체형별 인대모형 개발에 관한 연구)

  • Suh, Dong-Ae;Oh, Seol-Yong
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.9
    • /
    • pp.136-145
    • /
    • 2012
  • This research proposes a pattern making method for women's bodice by the characters of body types and develops bodice dress forms on their body shapes applying 3D body scan data. 515 women's body scan data was collected and analyzed factor and cluster analysis. Three body types were characterized in normal, obese, and slim group. In each group, 10 subjects were selected. 20 parts in 3D anthropometric data were measured using Autocad program. The amount of waist dart was calculated and three types of basic bodice pattern were developed using the calculated darts data. The amount and the position of front dart and side dart were different at obese group in comparison of normal and thin group. The three types of basic bodice model were made by the basic bodice pattern, and each model was scanned by 3D scanner to make 3D bodice dress forms. Three types of bodice dress forms were rendered using 3D max program. Bodice dress forms had the dart lines and were useful to draft patterns to fit their body shape.

Statistical Review for USNCAP Front Crash Test Results in MY2011 (2011년 모델에 대한 정면 미국신차안전도평가 결과에 대한 통계적 분석)

  • Beom, Hyen-Kyun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.5
    • /
    • pp.81-87
    • /
    • 2012
  • New car assessment program (NCAP) originated from USNCAP in 1979 has been implemented in several countries or markets, for instance USA, Europe, Korea, Japan, China and Australia. NCAP has contributed greatly to reduce accidental tolls. But recently, NCAP performance has no distinction between cars because manufacturer have been continuously developed to improve NCAP performance. Therefore, NHTSA announced new USNCAP protocol becoming effective from MY2011. NHTSA had carried out many NCAP tests based on the new test protocol and announced these test results. In this paper, USNCAP test results were reviewed by statistical method. This review was focused on passenger cars and frontal crash test results in order to investigate effect of changes in new NCAP protocol. There are two key changes, one is sited female dummy in passenger position, the other is enlarged to 4 scoring body regions in each dummy. Results of this review were summarized as followings. Performance in Passenger (12.5%) is lower than Driver's (50%) for number of 5 star vehicle. Neck injury criterion is dominant to NCAP star rating for both dummies in the mean sense. For standard deviation, chest deflection is showed largest value in driver dummy but neck injury criterion is showed for passenger's. DKAB and PKAB were equipped 28.1% and 6.2%, respectively. Consequently, the countermeasure for new USNCAP frontal crash test is essential to control well dummy kinematics with some safety features including KAB to reduce neck injuries.

Comparison on the Quality and fatigue of hands-Only CPR According to the Presence or Absence of Verbal counting by Some Middle-aged Women (일부 중년 여성에서 구령 유무에 따른 가슴압박소생술의 질과 피로도 비교)

  • Kim, Geon-Nam;Choi, Sung-Soo;Choi, Seong-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.3
    • /
    • pp.1320-1329
    • /
    • 2013
  • According to the comparing the quality and fatigue of Hands-only CPR with counting by middle-aged women who is most likely to witness the cardiac arrest. This paper wants to provide the basic data to establish a CPR education program for the role of the first responders. After conducted three hours of basic life support training, it divided into two 45-persons groups by assignment of probability. 2-minutes research conducted with dummy by dividing into Group-A that counting the number loudly during the Hands-Only CPR, And Group-B that does not counting the number during the Hands-Only CPR. Between the two groups, the quality of Hands-Only CPR does not showed its difference clearly and the downtime of Hands-Only CPR was reduced, Depending on the over time, the frequency that reduces the depth of Hands-Only CPR was also significantly lower. And after the Hands-Only CPR, the fatigability who felt themselves was also significantly lower.

Analysis of Lower Somatotype on Adult Women and Appearance Analysis of Flare Skirts by using the Image Processing (성인 여성의 하반신 체형분석과 염상처리를 이용한 플레어 스커트의 외관분석)

  • Lee, Soo-Jung;Hong, Jeong-Min
    • Fashion & Textile Research Journal
    • /
    • v.1 no.3
    • /
    • pp.252-258
    • /
    • 1999
  • The aims of this study is to classify the lower somatotype of adult women and appearance analysis on the shape of flare skirts by using the image processing. Also We have made skirts in order to analyze the various types of appearance of flare skirts by using the image processing. The subjects for our wear test lower somatotype, who were controlled in their waist, abdomen and hip shapes. The flare skirts used for wear test were 112 types(combinated 14 fabric type and 8 lower somatotype). The effect of lower somatotype on the shape of flare skirts was determined by the horizontally hem line section shape and the silhouette of flare skirts with image processing. The data were analyzed by using analysis of variance and Turkey, Duncan multiple range test. The results obtained are summarized as follows: It is shown that the fabric weight elongation differs in fabrics properties, in direction of textures. The shape horizontal section of flare skirt hem line has differed with the number of nodes, wave-height of nodes and breadth of silhouette by fabrics properties and lower somatotype. It is noticed that the breadth of flare skirts by the silhouette has high correlation with the drape ability of fabrics and lower somatotype. Results for our flare skirts show changes in amplitude and mean with fabrics, somatotype. Therefore we can say that gray-level histograms are correlated with changes in appearance, differences in drape spacing and related fabric properties and their somatotype.

  • PDF

Development of Dress Forms for the Aged Women Based on Their Body Shapes Applying 3D Body Scan Data (3차원 인체 형상을 이용한 실버 여성 패션 산업용 인대 모형 개발)

  • Kim, Soo-A;Choi, Hei-Sun
    • The Research Journal of the Costume Culture
    • /
    • v.18 no.1
    • /
    • pp.80-92
    • /
    • 2010
  • This research aims at developing the dress form for the aged women based on their body shapes using the three-dimensional body scan data with the body shape categorization(according to the previous research). To accomplish this goal, the sample group of representative body shape of the 50% of median was selected by using the high frequency proportion range of each type of body shape of the aged women, and the sample group of representative body shape of each type was averaged in a three-dimensional way by using the morphing method of a three-dimension reverse-engineered software. RP in the form of torso was produced based on the shape data of the final model and the data was formed into an actual object, by which an aged women's dress form model was drawn out. The differences of the girth of the bust, hip and waist between the developed dress form model and the existing dress form model were examined. The result showed that the developed dress form had a bigger size of waist girth than that of bust and hip girth, compared to the existing dress form, which shows that it reflects the aged women's tendency of abdomen obesity, so it's expected to be more proper for the human bodies of the targeted age group than the existing dress form. These research results may help design the clothing suitable for the body shape of the aged women so that their demand for the clothing of good fit will be satisfied in the future.

A Study on Absorbed Dose in the Breast Tissue using Geant4 simulation for Mammography (유방촬영에서 Geant4 시뮬레이션를 이용한 유방조직내 흡수선량에 관한 연구)

  • Lee, Sang-Ho;Lee, Jong-Seok;Han, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.345-352
    • /
    • 2012
  • As the breast cancer rate is increasing fast in Korean women, people pay more attention to mammography and number of mammography have been increasing dramatically over the last few years. Mammography is the only means to diagnose breast cancer early, but harms caused by radiation exposure shouldn't be overlooked. Therefore, it is important to calculate the radiation dose being absorbed into the breast tissue during the process of mammography for a protective measure against radiation exposure. Because it is impossible to directly measure the radiation dose being absorbed into the human body, statistical calculation methods are commonly used, and most of them are supposed to simulate the interaction between radiation and matter by describing the human body internal structure with anthropomorphic phantoms. However, a simulation using Geant4 Code of Monte Carlo Method, which is well-known as most accurate in calculating the absorbed dose inside the human body, helps calculate exact dose by recreating the anatomical human body structure as it is through the DICOM file of CT. To calculate the absorbed dose in the breast tissue, therefore, this study carried out a simulation using Geant4 Code, and by using the DICOM converted file provided by Geant4, this study changed the human body structure expressed on the CT image data into geometry needed for this simulation. Besides, this study attempted to verify if the dose calculation of Geant4 interlocking with the DICOM file is useful, by comparing the calculated dose provided by this simulation and the measured dose provided by the PTW ion chamber. As a result, under the condition of 28kVp/190mAs, the Difference(%) between the measured dose and the calculated dose was found to be 0.08 %~0.33 %, and at 28 kVp/70 mAs, the Difference(%) of dose was 0.01 %~0.16 %, both of which showed results within 2%, the effective difference range. Therefore, this study found out that calculation of the absorbed dose using Geant4 Simulation is useful in measuring the absorbed dose in the breast tissue for mammography.

Evaluation of Ovary Dose for woman of Childbearing age Woman with Breast cancer in tomotherapy (가임기 여성의 유방암 토모치료 시 난소선량 평가비교)

  • Lee, Soo Hyeung;Park, Soo Yeun;Choi, Ji Min;Park, Ju Young;Kim, Jong Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.337-343
    • /
    • 2014
  • Purpose : The aim of this study is to evaluate unwanted scattered dose to ovary by scattering and leakage generated from treatment fields of Tomotherapy for childbearing woman with breast cancer. Materials and Methods : The radiation treatments plans for left breast cancer were established using Tomotherapy planning system (Tomotherapy, Inc, USA). They were generated by using helical and direct Tomotherapy methods for comparison. The CT images for the planning were scanned with 2.5 mm slice thickness using anthropomorphic phantom (Alderson-Rando phantom, The Phantom Laboratory, USA). The measurement points for the ovary dose were determined at the points laterally 30 cm apart from mid-point of treatment field of the pelvis. The measurements were repeated five times and averaged using glass dosimeters (1.5 mm diameter and 12 mm of length) equipped with low-energy correction filter. The measures dose values were also converted to Organ Equivalent Dose (OED) by the linear exponential dose-response model. Results : Scattered doses of ovary which were measured based on two methods of Tomo helical and Tomo direct showed average of $64.94{\pm}0.84mGy$ and $37.64{\pm}1.20mGy$ in left ovary part and average of $64.38{\pm}1.85mGy$ and $32.96{\pm}1.11mGy$ in right ovary part. This showed when executing Tomotherapy, measured scattered dose of Tomo Helical method which has relatively greater monitor units (MUs) and longer irradiation time are approximately 1.8 times higher than Tomo direct method. Conclusion : Scattered dose of left and right ovary of childbearing women is lower than ICRP recommended does which is not seriously worried level against the infertility and secondary cancer occurrence. However, as breast cancer occurrence ages become younger in the future and radiation therapy using high-precision image guidance equipment like Tomotherapy is developed, clinical follow-up studies about the ovary dose of childbearing women patients would be more required.

Evaluation of HalcyonTM Fast kV CBCT effectiveness in radiation therapy in cervical cancer patients of childbearing age who performed ovarian transposition (난소전위술을 시행한 가임기 여성의 자궁경부암 방사선치료 시 난소선량 감소를 위한 HalcyonTM Fast kV CBCT의 유용성 평가 : Phantom study)

  • Lee Sung Jae;Shin Chung Hun;Choi So Young;Lee Dong Hyeong;Yoo Soon Mi;Song Heung Gwon;Yoon In Ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.73-82
    • /
    • 2022
  • Purpose: The purpose of this study is to evaluate the effectiveness of reducing the absorbed dose to the ovaries and the quality of the CBCT image when using the HalcyonTM Fast kV CBCT of cervical cancer patients of child-bearing age who performed ovarian transposition Materials and Methods : Contouring of the cervix and ovaries required for measurement was performed on the computed tomography images of the human phantom (Alderson Rando Phantom, USA), and three Optically Stimulated Luminescence Dosimeter(OSLD) were attached to the selected organ cross-section, respectively. In order to measure the absorbed dose to the cervix and ovaries in the TruebeamTM pelvis mode (Hereinafter referred to as TP), The HalcyonTM Pelvis mode (Hereinafter referred to as HP) and The HalcyonTM Pelvis Fast mode (Hereinafter referred to as HPF), An image was taken with a scan range of 17.5 cm and also taken an image that reduced the Scan range to 12.5cm. A total of 10 cumulative doses were summed, It was replaced with a value of 23 Fx, the number of cervical cancer treatments, and compared In additon, uniformity, low contrast visibility, spatial resolution, and geometric distortion were compared and analyzed using Catphan 504 phantom to compare CBCT image quality between equipment. Each factor was repeatedly measured three times, and the average value was obtained by analysing with the Doselab (Mobius Medical Systems, LP. Versions: 6.8) program. Results: As a result of measuring absorbed dose by CBCT with OSLD, TP and HP did not obtain significant results under the same conditions. The mode showing the greatest reduction value was HPF versus TP. In HPF, the absorbed dose was reduced by 39.8% in the cervix and 19.8% in the ovary compared to the TP in the scan range of 17.5 cm. the scan range was reduced to 12.5 cm, absorbed dose was reduced by 34.2% in the cervix and 50.5% in the ovary. In addition, result of evaluating the quality of the image used in the above experiment, it complied with the equipment manufacturer's standards with Geometric Distortion within 1mm (SBRT standard), Uniformity HU, LCV within 2.0%, Spatial Resolution more than 3 lp/mm. Conclusion: According to the results of this experiment, HalcyonTM can select more various conditions than TruebeamTM in treatment of fertility woman who have undergone ovarian Transposition , because it is important to reduce the radiation dose by CBCT during radiation therapy. So finally we recommend HalcyonTM Fast kV CBCT which maintains image quality even at low mAs. However, it is consider that the additional exposure to low doses can be reduced by controlling the imaging range for patients who have undergone ovarian transposition in other treatment machines.