• 제목/요약/키워드: 여과집진기

검색결과 37건 처리시간 0.022초

사각형 여과집진기 충격기류 시스템의 최적탈진조건에 관한 실험적 연구 (Experimental study on the optimum pulse jet cleaning conditions of a rectangular bag-filter system)

  • 박승욱;김태형;이효우;하현철;정재훈
    • 한국산업보건학회지
    • /
    • 제18권3호
    • /
    • pp.189-203
    • /
    • 2008
  • Cylindrical bag filter system with pulse jet cleaning has been the most common device to control particle laden exhaust gas from the various industrial processes. But, it has many shortcomings due to particle reattachment and frequent bag rupture. In recent years, rectangular type bag filter system has been developed to overcome the problems associated with the cylindrical system. However, not many studies about the rectangular system were not done, compared to the cylindrical system. In this study, the optimum pulse jet cleaning conditions were thus tested by the series of experiments. The factors tested in this study are pulse distance, pulse pressure, pulse duration, the number of holes for pulsing and bag materials. A single bag ($1,500mmL{\times}50mmW{\times}300mmH$) system and a multi-bags (3 bags in a row) were tested separately. The highest removal efficiency with a single bag system was found at the conditions with pulse distance of 10cm, pulse pressure of $3kg/cm^2$, pulse duration of 0.3s, pulse jet number of 6 and Polyester bag. With the multi-bags system, the best cleaning conditions were found at the bag interval of 20cm with the simultaneous pulsing and the bag interval of 15cm with the serial pulsing.

여과집진기의 탈진 거동 개선에 관한 연구 (A study on the improvement of cleaning performance in bag-filter)

  • 홍성길;금영호;손병현
    • 한국산학기술학회논문지
    • /
    • 제16권2호
    • /
    • pp.1571-1578
    • /
    • 2015
  • 전산유체역학(CFD)을 이용하여 산업체에 널리 적용되고 있는 충격기류형 탈진시스템의 탈진 특성을 규명하고, 그 성능을 향상시키기 위해 탈진부 유니트(unit) 형상을 개조한 경우의 탈진 성능을 비교하였다. 탈진부 각 형상에 대해 검토한 결과, 블로우 튜브에 노즐을 설치한 경우(Case 3)와 벤츄리에 이중 유입관을 설치한 경우(Case4, 5)가 현재 현장에서 널리 적용되고 있는 구조(Case 1)에 비해 우수한 것으로 예측되었다. 또한 최적 형상의 벤츄리를 설계하고, 이 벤츄리를 pilot plant에서 실험하여 현장 적용성을 분석하였다. 블로우 튜브와 본 연구에서 제안한 벤츄리를 조합한 시스템의 경우, 기존 시스템(블로 튜브만 사용한 경우와 블로 튜브와 벤츄리를 조합한 경우)에 비해 탈진 기류를 집중시키는데 매우 효과적인 것으로 나타났다. 또한 본 연구에서 제안한 벤츄리를 장착하여 테스트한 결과, 산업 현장에서 사용 중인 상용 벤츄리를 사용한 경우 보다 탈진횟수 및 탈진시간이 많이 향상되는 결과를 보였다.

고효율 호흡보호구의 나노물질 입경별 제거 효율 (Fractional efficiency of Nanomaterials for the High efficiency respiratory filters)

  • 이광재;지준호;김원근;육세진;김종규;김정호
    • 한국입자에어로졸학회지
    • /
    • 제12권3호
    • /
    • pp.95-102
    • /
    • 2016
  • 본 연구에서는 호흡용 보호구 필터의 나노물질에 대한 여과특성을 측정하기 위해서 소금(NaCl)과 은나노입자(Ag)를 대상으로 입경별 집진효율을 평가하였다. 호흡용 보호구 필터는 특급 방진마스크와 1급 방진마스크의 두 가지 안면부 여과식 방진마스크인 사용하였고, 마스크의 배기밸브 부분을 제외한 필터 여재 부분을 직경 47 mm로 잘라내어 필터홀더에 부착하여 입경별 입자제거효율을 시험하였다. 시험입자는 일반적으로 시험 입자로 사용되는 소금입자는 분무형 입자발생장치를 사용하여 발생하였고 중화기를 통과시켜 입자의 하전특성을 볼츠만 분포로 만들어 공급하였다. 은나노입자의 경우, 기화-응축 방법을 이용한 금속나노입자 생성방법인 ISO10801 방법을 사용하였다. 작업장의 은나노입자의 고농도 노출을 모사하기 위해, 중화기를 통과하지 않은 나노입자를 시험입자로 사용하였다. 은나노입자의 경우 소금입자로 만들기 어려운 20nm 이하의 입자를 안정적으로 효과적으로 만들어 시험에 적용하였고, 나노 크기에서도 매우 안정적인 데이터를 확보할 수 있었다. 1급 마스크 필터와 특급 마스크 필터에 대한 소금입자의 평가에서, 입경별 최소효율이 30~50nm 사이에서 나타나는 특성은 기존 연구와 비슷한 결과를 얻었다. 반면, 은나노입자의 경우 1급 마스크 필터와 특급 마스크 필터 모두에서 비슷한 크기의 소금 입자와 비교할 때 높은 효율을 나타냈다. 이것은 소금 입자의 경우 중화기를 통과시켜 시험입자로 사 용한 반면, 은나노입자의 경우 중화기를 통과시키지 않았기 때문이다. 본 연구에서는 작업장에서 은나노 입자가 고농도로 노출될 경우를 모사하여, 기화-응축에 의한 방법의 은나노입자 발생장치를 사용하였는데, 이 때 상대적으로 높게 대전된 입자들이 많이 만들어진다(Jung et al., 2006). 이로 인해, 정전필터인 마스크 필터의 포집 효과가 상대적으로 크기 때문에, 입경별 효율이 높아진 것으로 생각된다. 본 연구에서 평가한 1급 및 특급 방진마스크 여재의 최소 포집효율은 유럽 EN 149 기준인 95 LPM 유량 기준을 만족하는 것으로 나타났지만, 이것은 여재에 대한 평가 결과로, 실제 마스크에 대해서는 여재의 구조적인 불균일성이나 마스크를 착용하는 과정에서 밀착이 되지 않아 누출될 가능성은 마스크 사용에 고려되어야 한다. 불시에 발생할 수 있는 작업장 내 안전사고의 예방을 위하여 적절한 보호구의 선택과 올바른 착용 및 유지관리가 필요할 것으로 생각된다.

사각형 여과 집진기 충격기류 탈진시스템의 기초 연구 (The Fundamental Study on Pulse Jet Cleaning of Rectangular Bag-Filter System)

  • 박승욱;김태형;양준호;이효우;하현철;정재훈
    • 한국산업보건학회지
    • /
    • 제18권2호
    • /
    • pp.149-160
    • /
    • 2008
  • Bag-filter system has been widely used in industrial field to remove the particulate matters from the exhaust gas. The cylindrical type of bag-filter has been generally used. But it has many shortcomings. The reattachment of separated particles on the surface of bags could result in high pressure drop of bag-filter system and subsequent decrease of air flow rate since the cylindrical type bag-filter system should have the upward flow pattern. In addition, the supply of very high pressure pulse air jet to remove particulate matters on the surface of filter could result in a frequent rupture of bags. To overcome these shortcomings of the cylindrical type, the rectangular type was developed in the developed countries and imported to Korea. But, there was not many design data available to understand the mechanisms. Thus, the fundamental experiments were conducted in this study to get some ideas about the pulse jet cleaning of rectangular type bag filter system. The experimental factors are as follows; pulse distance, pulse duration, pulse interval, pulse pressure and pulse nozzle type. Experiments followed the factorial design method. With the shorter pulse distance, the distribution of pressure drops was relatively not uniform while the particulate removal efficiency was higher. With the longer duration of pulsing and the more number of pulse nozzle, the removal efficiency was higher and the pressure drop distribution was more uniform.

공기부유진내(空氣浮游塵內)의 Radon 붕괴생성물(崩壞生成物)의 농도측정(濃度測定) (Measurement of Radon Daughters in Airborne Dust)

  • 김필수;민덕기;노성기
    • Journal of Radiation Protection and Research
    • /
    • 제2권1호
    • /
    • pp.9-16
    • /
    • 1977
  • 공기부유진내(空氣浮游塵內)에 존재(存在)하는 라돈 붕괴생성물(崩壞生成物) 즉(卽) RaA, RaB및 RaC의 간단(簡單)한 농도측정법(濃度測定法)을 확립(確立)하였다. 이것은 단일집진장치(單一集塵裝置)로 membrane 여과지(濾過紙)(평균(平均) pore size=$0.8{\mu}m$)에 채취(採取)한 시료(試料)의 전(全)알파 방사능(放射能)을 시차별(時差別)로 측정(測定)하므로서 농도(濃度)를 결정(決定)하는 방법(方法)이다. 일연(一聯)의 예비실험(豫備實驗)으로써 이 방법(方法)을 이용(利用)하여 한국원자력연구소(韓國原子力硏究所) 구내(構內)에서 라돈 붕괴생성물(崩壞生成物)의 시간적(時間的) 농도변화(濃度變化)를 측정(測定)하였다. 이들 농도(濃度)의 시간적(時間的) 변화(變化)는 심(甚)하였는데 대개(大槪)의 경우(境遇) 최고치(最高値)는 대기(大氣)의 밀도(密度)가 비교적(比較的) 높은 아침에 나타났고 최고치(最高値)는 기(其) 반대(反對)인 오후(午後)에 나타났다.

  • PDF

선박 디젤엔진 배출 미세먼지 저감을 위한 정전 여과 매연 집진기 개발에 관한 연구 (An Electrostatic Diesel Particulate Filtration System for Removal of Fine Particulate Matters from Marine Diesel Engines)

  • 김영훈;이건희;홍기정;김용진;김학준;박인용;한방우
    • 한국입자에어로졸학회지
    • /
    • 제19권4호
    • /
    • pp.101-110
    • /
    • 2023
  • In order to reduce particulate matters (PM) from marine diesel engines, we developed novel electrostatic diesel particulate matter filtration system. Electrostatic diesel particulate filtration (DPF) system consists of electrostatic charger and filtration part. The electrostatic charger and filtration part are composed of a metal discharge electrode and a metal fiber filter (porosity: 68.1-86.1%), respectively. In the electrostatic charger part, diesel soot particles are reduced by electrostatic force. The filtration part after electrostatic charger part reduces diesel soot particles through inertial and diffusion forces. The filtration efficiency of electrostatic DPF system was examined through the experiments using engine dynamometer system (300 kW) and ship (200 kW). The PM reduction efficiencies due to inertial and electrostatic forces showed about 70-75% and 80-90%, respectively, according to the RPM of the engine. The differential pressure of the electrostatic DPF system applied to the ship was about 1-9 mbar, which was less than the allowable differential pressure for ship engines in South Korea (100 mbar). The results show that the electrostatic DPF system is suitable for application to the PM reduction emitted from ships.

여과집진기의 탈진 성능 향상을 위한 충격 기류 분사 시스템 최적화 설계에 관한 연구 (A study on the optimization design of pulse air jet system to improve bag-filter performance)

  • 홍성길;정유진;박기우;정문헌;임기혁;서혜민;손병현
    • 한국산학기술학회논문지
    • /
    • 제13권8호
    • /
    • pp.3792-3799
    • /
    • 2012
  • 본 연구에서는 전산유체역학(CFD)을 이용하여 산업체에 널리 적용되고 있는 충격기류형 탈진시스템의 탈진 특성을 규명하고, 그 성능을 향상시키기 위해 탈진부 유니트(unit) 형상을 개조한 경우의 탈진 성능을 비교하였다. 탈진부 각 형상별로 탈진 공기량과 기류 분포, 유입속도 분포 등을 검토한 결과, 블로우 튜브에 노즐을 설치한 경우(Case 3)와 벤츄리에 이중 유입관을 설치한 경우(Case4, 5)가 현재 현장에서 널리 적용되고 있는 구조(Case 1)에 비해 탈진 공기량의 증폭 효과 및 기류 폭의 확장 현상이 우수한 것으로 예측되었다. 선정된 Case-5를 상용 백필터의 사양(직경 150 mm)에 적용하기 위해 벤츄리 제원을 결정한 결과, 내측 유입관의 직경 50 mm, 외측 유입관의 직경 90 mm의 제원을 적용하면 탈진 공기량을 최대로 유지할 수 있을 것으로 판단된다.