• Title/Summary/Keyword: 여과장치

Search Result 384, Processing Time 0.03 seconds

A Study of Sewage Treatment with a Self-Cleaning Filtration Unit (자기세정 여과 반응장치를 이용한 하수처리에 관한 연구)

  • Mo, Sung-Young;Lee, Pul-Eip;Kim, Bum-Su;Lee, Tae-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.6
    • /
    • pp.309-316
    • /
    • 2016
  • In this study, sewage was fed with up flow direction into a reactor equipped with a screw to circulate media that had lower specific gravity than water. It was observed that the media in the reactor could be circulated by a screw with reverse flow of the sewage feeding from the top to the bottom direction. Under these conditions, concentrations of inflow and outflow pollutants were measured at the filtration unit. Experimental results revealed stable circulation of the media with a screw in the reactor. Circulation of the media in the reactor showed more efficiency in removing the pollutants (particulate matters and organics) than no circulation. The maximum removal efficiencies of suspended solid (SS), chemical oxygen demand (CODmn), and total phosphorus (T-P) were 96%, 72% and 65%, respectively. Improvements for SS, CODmn and T-P removals with circulation of media were 52.38%, 43.14% and 118.12% respectively, compared to those without circulation.

A Study on the Flow Characteristic of the Diesel Engine DPF (디젤엔진용 매연여과장치 내부유동 특성 연구)

  • Go, Hyun-Sun;Jung, Chan-Gyu;Lee, Heang-Nam
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.1
    • /
    • pp.109-117
    • /
    • 2012
  • This paper addresses influence on the flow field by varying the length of DPF Inlet pipe in 5 ways. Numerical analysis is carried out by using PIV and commercial code and as a result, PIV and commercial code shows correlation correspond to 87%. Furthermore, in the same velocity condition, as stable and high pressure value is shown when the Inlet pipe length is 20mm, particulate filtering rate can be increased.

A Study on the Flow Characteristics according to the Change of Structure in Filtration Using the Numerical Model (수치모형을 이용한 여과기 내 구조 변경에 따른 유동특성 연구)

  • Kim, Taewon;Song, Sooho;Choi, Changhyung;Park, Youngjin;Kim, Jiho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.285-285
    • /
    • 2017
  • 최근 전 세계적으로 심각해지는 물 부족 현상과 수질오염으로 대량의 원수를 빠른 시간 내에 여과하기 위한 여과장치의 개발 및 효율성 향상을 위한 연구의 필요성이 증가되고 있다. 특히 여과필터의 내부구조에 의해 유동이 편중되는 현상이 발생하면 여과효율 및 여과필터 유지관리에 문제가 발생되기 때문에 최적의 여과필터를 설계하는 것이 중요하다. 이에 본 연구에서는 수리모형실험으로 검토하기에 어려움이 있는 여과기 내부구조에 대한 유동특성을 수치해석을 이용하여 검토하였다. 수치해석은 유한요소법 기반의 수치모형으로 여과기 내부를 상세하게 모의할 수 없기 때문에 유한체적법 기반인 ANSYS CFX 모형을 이용하였다. 여과기 내 여과필터는 두께 2.0 mm, 공극율 25%로 가정하고 다공성 기법(porous media)을 적용하였다. 검토를 위한 경계조건은 유입부에 목표 취수량, 유출부에 대기압 조건을 적용하였으며, 여과기에 비해 매우 작게 구성된 여과필터 내부의 유동특성을 검토하기 위해 여과기는 최소 3.0 mm, 여과필터는 1.0 mm의 격자를 적용하였다. 현재 실제 여과시설에 적용되고 있는 여과기 제품 형상을 기준으로 여과기 내부 흐름공간의 크기 및 각도 조정에 따른 유동특성을 검토하여 여과효율을 비교하였으며 통과유량, 유속, 유속벡터 등을 검토하여 균등한 유량과 유속이 발생되는 최적의 여과장치 구조를 도출하였다. 본 연구에서 여과기 내부 구조 변경에 따른 유동특성 검토를 통해 도출된 최적의 여과기 내부크기 및 각도에 대한 설계인자는 여과기 내 여과필터의 효율을 증가시킬 뿐만 아니라 내구성 증진에 도움이 될 것으로 예상된다.

  • PDF

A Hybrid Dust Collector(Hi-Filter) for Reducing Dust Load (먼지부하 저감형 하이브리드 여과집진장치(Hi-filter))

  • 최호경;박석주;임정환;김상도;박현설;박영옥
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2002.05a
    • /
    • pp.223-226
    • /
    • 2002
  • 본 연구에서는 전기집진 기술과 여과집진 기술의 조합에 의한 먼지입자의 포집성능 상승효과를 최대한 높일 수 있는 먼지부하 저감형 하이브리드 집진장치(Hi-Filter)를 개발하기 위해 실험실 규모의 장치를 이용한 실험을 통하여 장치의 최적 형상을 결정하고 그 성능을 검증하였다.(중략)

  • PDF

Seismic Analysis of Traveling Sea Water Screen (해수여과장치의 내진해석)

  • Kim, Heung-Tae;Lee, Young-Shin;Park, Young-Moon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.3
    • /
    • pp.289-294
    • /
    • 2011
  • In this study, the seismic analysis of traveling sea water screen for nuclear power plant was performed using finite element model. For qualification of traveling sea water screen, the response spectrum analysis was performed using the given operating basis earthquake(OBE) and safe shutdown earthquake(SSE) floor response spectrum. Dynamic analysis of water sea traveling screen was performed using finite element method. The analytical maximum displacements of traveling sea water screen were 2.5 mm under OBE condition and 4.6 mm under SSE condition. The maximum stresses of traveling sea water screen were 24 MPa under OBE condition and 44 MPa under SSE condition, that this results were 18 %, 27% of yield strength of material. Thus, it can shown that the structural integrity of traveling sea water screen has a stable structure for seismic load conditions.

Influence of Flocculants During Vacuum Dewatering of Radioactive Slurry Waste (방사성 슬러리 폐액의 탈수에서 응집제 효과)

  • 정경환;이동규;정기정
    • Journal of Energy Engineering
    • /
    • v.10 no.2
    • /
    • pp.114-119
    • /
    • 2001
  • TRIGA Mark-II&III 연구로서의 운영과정에서 발생된 방사성 슬러리 함유 폐액에 대하여 음이온, 앙이온, 그리고 비이온 응집제를 첨가하였을 때의 여과 효과를 실험실 규모의 진공여과 장치로 연구하였다. 여과 실험 자료를 이용하여 Darcy’s Law에서 유도된 여과 케익 저항 값을 산출하였다. 응집제 사용으로 응집제를 사용하지 않은 경우롸 비교하여 케익 저항값의 개선은 있었지만, 수분함량은 증가하였다. 각각의 응집제 사용에 따른 침전율, 여과 케익의 수분함량, 그리고 여과 케익 저항 값을 비교한 결과 음이온 응집제 12~16ppm/$\ell$ waste를 사용하였을 경우가 가장 효과적인 것으로 나타났다.

  • PDF

Study on Algae and Turbidity Removal by Floating-media and Sand Filter (부상여재 및 모래 여과장치에 의한 조류와 탁도 제거에 관한 연구)

  • Kwon, Dae-Young;Kwon, Jae-Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.5
    • /
    • pp.659-668
    • /
    • 2012
  • In Korea, almost every water treatment plant suffers from seasonal problem of algae and turbidity which result from eutrophication and heavy rainfall. To relieve this problem, experimental investigation was performed to study the applicability of a floating-media and sand filter to preliminary water treatment in terms of algae and turbidity removal. Experimental results using pure-cultured algae influent showed that the shape of algae species as well as filtration velocity affects the removal efficiency. From the experiments using natural river water, it was concluded that algae removal is more sensitive to floating-media depth but turbidity more sensitive to sand depth. As the filtration velocity increased, the removal of turbidity decreased but that of algae was not affected. The floating-media and sand filter removed more than 30 % of TP, TN, turbidity, Chl-a and CODcr, and less than 20 % of DOC and $UV_{254}$.

Characteristics of Hybrid Precipitator Combined With Impaction Porous Plate (임팩션 다공성 Plate가 결합된 Hybrid 집진 시스템의 특성)

  • 조용수;여석준
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.395-396
    • /
    • 2003
  • 최근, 고효율 집진장치로 새롭게 부각되고 있는 hybrid 집진 시스템은 2가지 이상의 집진 메카니즘을 1기의 단일 시스템에 결합시킴으로써, 시스템의 고성능화와 장치의 규모 및 설치비를 줄일 수 있는 중요한 장점을 지니고 있다. 본 연구에서는 전기력, 원심력 및 impaction 메카니즘(시스템 내부에 임팩션 효과를 유발시키는 impaction porous plate의 설치)을 결합하여 99% 이상의 집진효율을 기대할 수 있는 hybrid 집진 시스템의 특성을 연구하였다. 이는 99%의 고효율을 유지하는 기존 여과집진장치의 문제점인 낮은 여과속도(즉, 장치의 대형화), filter의 유지ㆍ관리 및 탈진 공정에 의한 연속 조업의 어려움 등을 동시에 해결할 수 있는 집진 시스템으로 이에 대한 연구가 수행되면 기존 가장 광범위하게 사용되지만, 많은 문제점을 지니고 있는 여과집진기를 대체할 수 있는 새로운 개념의 집진 시스템이 개발될 수 있을 것으로 생각된다. (중략)

  • PDF