• Title/Summary/Keyword: 에코

Search Result 1,085, Processing Time 0.029 seconds

Granulosa Cell Tumor of Ovary in a Yorkshire terrier Dog (요크셔테리어에서 발생한 난소의 Granulosa cell tumor)

  • Sung, Ju-Heon;Yoo, Jong-Hyun;Kang, Byeong-Tack;Park, Chul;Jung, Dong-In;Park, Jong-Im;Park, Hee-Myung
    • Journal of Veterinary Clinics
    • /
    • v.24 no.1
    • /
    • pp.38-41
    • /
    • 2007
  • A 12-year-old, intact female Yorkshire terrier was presented with progressive abdominal distention. On radiographic and ultrasonographic evaluation, a large mass was detected in right upper abdomen and it had several discrete anechoic follicles and large cysts. The mass was removed by complete ovariohysterectomy and the resected specimen was histopathologically examined. Based on the gross and histopathologic findings, the mass was definitely diagnosed as malignant granulosa cell tumor (GCT). Until now, the dog has been successfully managed more than a year without complications.

Imaging Diagnosis: Biphasic Synovial Sarcoma in a Dog (개에서 발생한 이상성 활막육종 증례)

  • Eom, Ki-Dong;Sung, Yun-Sang;Park, Jong-Im;Park, Hee-Myung;Jung, Soon-Wuk;Kim, Jae-Hoon
    • Journal of Veterinary Clinics
    • /
    • v.24 no.1
    • /
    • pp.26-28
    • /
    • 2007
  • An 11-year-old castrated male, Shih-tzu dog was admitted for progressive weight-bearing lameness and mass on the right hindlimb. Radiography and ultrasonography revealed a large well-marginated multinodular mass with mixed echogenicity. On T1 and T2-weighted magnetic resonance imaging (MRI), the mass has a heterogenous signal intensity similar to or higher than muscle. The masses were extended to the pelvic cavi쇼 through obturator foramen and displaced the rectum dorsally. It was diagnosed as synovial sarcoma which was composed with mesenchymal and epithelial elements on histopathological findings of the multifocal biopsied specimen. MRI was helpful to determine the definitive margin for surgical resection of the mass. The mass was recurred at the 6th month after surgery. On the 10th month, the patient was euthanasiuzed by owner's request.

Imaging Diagnosis: Heartbase Tumor in a Dog (개의 심기저부 종양의 영상진단학적 특징)

  • Chang, Jin-Hwa;Jung, Joo-Hyun;Yoon, Jung-Hee;Choi, Min-Cheol
    • Journal of Veterinary Clinics
    • /
    • v.25 no.1
    • /
    • pp.48-51
    • /
    • 2008
  • A ten-year-old Yorkshire Terrier developed serious abdominal distension and respiratory distress. Radiography and ultrasonography revealed a hyperechoic mass around the aorta that was contiguous with the right atrium and main pulmonary artery. It was resulted in failure of the right side of the heart including tricuspid regurgitation, hepatomegaly with dilation of the hepatic vein and severe ascites due to a large, expansile mass. Computed tomography(CT) identified a large mass originating at the cardiac hilar region and spanning from the cranial vena cava to the caudal vena cava. The tumor had invaded the cranial vena cava, caudal vena cava, heart and pleural wall. A tentative diagnosis of chemodectoma was assigned to the tumor through a fine needle aspiration. This report focuses on the typical features of imaging diagnosis of heartbase tumors by radiography, ultrasonography and CT.

Primary Renal Hemangiosarcoma Complicated with Hematuria and Hemoperitoneum in a Dog (개에서 발생한 혈뇨와 복강 내 출혈을 동반한 신장원성 혈관육종)

  • Yeo, Jung-Jin;Sur, Jung-Hyang;Eom, Ki-Dong;Park, Hee-Myung
    • Journal of Veterinary Clinics
    • /
    • v.29 no.2
    • /
    • pp.165-168
    • /
    • 2012
  • A 14-year-old intact male Siberian Husky was presented with hematuria, lethargy, and anorexia of 1-month duration. The physical examination revealed mild abdominal distension and pain. The hematology and serum chemistry revealed anemia and severe azotemia. The radiographic examination revealed renomegaly and the ultrasonographic examination, indistinct cortico-medullary junction, increased renal cortex echogenicity, and irregular margination. The urinalysis showed proteinuria and hematuria. The differential diagnosis included renal failure, cystitis, pyelonephritis, and neoplasia. The patient's condition continued to deteriorate, and the dog eventually died. The gross findings from the necropsy revealed hemoperitoneum and a bilateral renal mass. HSA was diagnosed by histopathological examination. This case report describes primary bilateral renal hemangiosarcoma (HSA), which is uncommon in dogs.

Pancreatic Exocrine Adenocarcinoma in a Cat (고양이에서 발생한 췌장 외분비 선암종 1례)

  • Park, Noh-Won;Lee, Seung-Yeoun;Lee, So-Yun;Song, Sun-Hye;Choi, Yang-Kyu;Eom, Ki-Dong
    • Journal of Veterinary Clinics
    • /
    • v.30 no.3
    • /
    • pp.189-192
    • /
    • 2013
  • An 8-year-old, neutered female Korean short hair cat was referred with severe vomiting and anorexia. Abdominal mass effect was seen in the cranial abdomen on radiographs, and a mass with a heterogeneous echogenic pattern was observed medial to the right kidney on ultrasonography. On computed tomography, a large mass with soft tissue attenuation and a contrast-enhanced capsule was seen. In histopathological findings, the acinar structures were lined with irregular cuboidal cells that have pale eosinophilic cytoplasm and round to oval nuclei. Based on these diagnostic imaging and histopathological findings, the mass was diagnosed as pancreatic exocrine adenocarcinoma.

High Quality Audio Watermarking using Spread Spectrum and Psychoacoustic Model (대역확산과 심리음향 모델을 이용한 고음질 오디오 워터마킹)

  • Noh Jin-Soo;Rhee Kang-Hyeon
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.43 no.5 s.311
    • /
    • pp.48-56
    • /
    • 2006
  • In this paper, we proposed the high quality audio watermarking algorithm using MDCT/IMDCT (Modified DCT/Inverse Modified DCT) with psychoacoustic model. Generally, a digital audio watermark is embedding the frequency domain after frequency transform of the digital audio data but the digital audio quality is affected by watermarking. In our scheme, the digital audio data is spread with PN((Pseudo Noise) code and then audio watermark is embedded in MDCT processing that refers psychoacoustic model. In MDCT processing, according to the shape of filter bank output, the block switching selects a window sequence that has 256, 1,024 or 2,048 points interval for high quality audio. The author confirm that when watermark weight ${\alpha}$ is 2.5 below, the detection ratio of watermark is a satisfied to SDMI's(Secure Digital Music Initiative) recommendation 50% above and SM is $50{\sim}68dB$ range with mainly 4 kind of attacks(Compression, Cropping, FFT and Echo).

Conversational Quality Measurement System for Mobile VoIP Speech Communication (모바일 VoIP 음성통신을 위한 대화음질 측정 시스템)

  • Cho, Jae-Man;Kim, Hyoung-Gook
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.10 no.4
    • /
    • pp.71-77
    • /
    • 2011
  • In this paper, we propose a conversational quality measurement (CQM) system for providing the objective QoS of high quality mobile VoIP voice telecommunication. For measuring the conversational quality, the VoIP telecommunication system is implemented in two smart phones connected with VoIP. The VoIP telecommunication system consists of echo cancellation, noise reduction, speech encoding/decoding, packet generation with RTP (Real-Time Protocol), jitter buffer control and POS (Play-out Schedule) with LC (loss Concealment). The CQM system is connected to a microphone and a speaker of each smart phone. The voice signal of each speaker is recorded and used to measure CE (Conversational Efficiency), CS (Conversational Symmetry), PESQ (Perceptual Evaluation of Speech Quality) and CE-CS-PESQ correlation. We prove the CQM system by measuring CE, CS and PESQ under various SNR, delay and loss due to IP network environment.

Real-time Interactive Control of Magnetic Resonance Imaging System Using High-speed Digital Signal Processors (고속 DSP를 이용한 실시간 자기공명영상시스템 제어)

  • 안창범;김휴정;이흥규
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.40 no.5
    • /
    • pp.341-349
    • /
    • 2003
  • A real time interactive controller (spectrometer) for magnetic resonance imaging (MRI) system has been developed using high speed digital signal processors (DSP). The controller generates radio frequency (rf) waveforms and audio frequency gradient waveforms and controls multiple receivers for data acquisition. By employing DSPs having high computational power (e.g., TMS320C670l) real time generation of complicated gradient waveforms and interactive control of selection planes are possible, which are important features in real-time imaging of moving organs, e.g., cardiac imaging. The spectrometer was successfully implemented at a 1.5 Tesla whole body MRI system for clinical application. Performance of the spectrometer is verified by various experiments including high- speed imaging such as fast spin echo (FSE) and echo planar imaging (EPI). These high-speed imaging techniques reduce measurement time, however, usually intensify artifact if there is any systematic phase error or jitter in the synchronization between the transmitter, receiver, and gradients.

Compressive Strength and Ecological Characteristics of Mortars Using Expanded Vermiculite Absorbing Bacteria (박테리아를 흡착한 팽창질석 기반의 친생태 모르타르 개발)

  • Yoon, Hyun-Sub;Jung, Seung-Bae;Yang, Keun-Hyeok;Lee, Sang-Seob;Lee, Jae-Young
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.2
    • /
    • pp.165-171
    • /
    • 2016
  • The objective of this study is to evaluate the compressive strength development and ecological characteristics of mortars using expanded vermiculite absorbing bacteria as a fundamental investigation to develop precast eco-concrete products. For bacterial growth under the high-alkalinity and high-dried environments within hardened mortars and for creating plant growth function to mortars, Bacillus alcalophilus and Rhodoblastus acidophilus were separated and cultured. The cultured bacteria were absorbed into expanded vermiculite selected for bacteria shelter. The expanded vermiculite absorbing bacteria was then added into mortar mixture as a volumetric replacement of fine aggregate. Test results showed that the developed technology is very effective in enhancing the plant growth onto the hardened mortars and reducing the COD and T-N concentration in raw water. The optimum replacement level of expanded vermiculite absorbing bacteria can be recommended to be less than 10% considering the compressive strength development and cost of mortars along with the ecological effectiveness.

A Study on the Effect of strength improvement and $CO_2$ reduction by using Eco-concrete in construction site (에코콘크리트 현장 적용에 따른 강도 상승 효과 및 이산화탄소 절감 효과에 관한 연구)

  • Kim, Jeong-Jin;Hwang, Yin-Seong;Lee, Sang-Hyun;We, Joon-Woo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.1
    • /
    • pp.80-87
    • /
    • 2011
  • Blast furnance slag cement is a cement manufactured with using industrial by-product and it can reduce $CO_2$ by replacing cement when same uit volume concrete is produced. But Blast furnance slag has a short point that early strength of concrete is not good in winter season and it can be used. So, in this study, as long as replacement ratio of Blast furnance slag to original portland cement is under 30%, developed cement, ecoment, improve early strength of concrete and it applied to constructoin site. As a result, it improves 37% in terms of 1-day strength, it reduces 6.7% in terms of $CO_2$ emission when $1m^3$ concrete was produced. The importance and applicability of study wll be expected to increase cosidering global effort and green growth-strategy in country for reducing greenhouse gases.

  • PDF