• Title/Summary/Keyword: 에어로졸 입자

Search Result 446, Processing Time 0.021 seconds

The performance of Bio-aerosol Detection System (BDS) with 405 nm laser diode (405 nm 광원을 이용한 생물입자탐지기의 에어로졸 분석성능)

  • Jeong, Young-Su;Chong, Eugene;Lee, Jong-Min;Choi, Kibong
    • Particle and aerosol research
    • /
    • v.13 no.1
    • /
    • pp.25-31
    • /
    • 2017
  • This paper offer the characteristics for the detection and classification of biological and non-biological aerosol particles in the air by using laser-induced-fluorescence (LIF) based Bio-aerosol Detection System (BDS). The BDS is mainly consist of an optical chamber, in-outlet nozzle system, 405 nm diode laser, an avalanche photo detector (APD) for scattering signal and photomultiplier tubes (PMT) for fluorescence signals in two different wavelength range ; F1, 510-600 nm and F2, 435-470 nm. The detection characteristics, especially ratio of fluorescence signal intensity were examined using well-known components : polystylene latex (PSL), fluorescence PSL, $2{\mu}m$ of SiO2 micro sphere, dried yeast, NADH, ovalbumin, fungicide powder and standard dust. The results indicated that the 405 nm diode laser-based LIF instrument can be a useful bio-aerosol detection system for unexpected biological threaten alter in real-time to apply for dual-use technology in military and civilian fields.

Synthesis of Polymer-Carbon Nanotubes Composite Nanoparticles and Their Applications into Forming Hybrid Composite Thin Films (폴리머-탄소나노튜브 복합체 에어로졸 입자의 생성 및 이를 이용한 하이브리드 복합체 박막 제조)

  • Kim, Whi-Dong;Ahn, Ji-Young;Kim, Soo Hyung
    • Particle and aerosol research
    • /
    • v.6 no.2
    • /
    • pp.61-67
    • /
    • 2010
  • In this paper, we describe a new method to form polymer thin films, in which carbon nanotubes (CNTs) are homogeneously distributed so that they can strengthen the mechanical property of resulting polymer film. To do so, we first homogeneously mixed CNTs with polymer in a DMF solvent. With the assistance of ultrasonic nebulizer, the polymer/CNT solution was then aerosolized into micro-sized droplets and finally turned into solidified polymer/CNT composite particles by gas-phase drying process. As the results of SEM and TEM analysis, CNTs were found to be homogeneously immobilized in the polymer matrix particles due to rapid drying process in the gas phase. For comparison purpose, (i) the polymer/CNTs composite particles prepared by aerosol processing method and (ii) polymer/CNTs sheets prepared by simple solution-evaporation method were employed to form polymer/CNTs composite thin films using a hot press. As the result, the aerosol processing of composite particles was found to be a much more effective method to form homogeneously distributed-CNTs in the polymer matrix thin film.

Development of Aerosol-LIBS (Laser Induced Breakdown Spectroscopy) for Real-time Monitoring of Process-induced Particles (공정 중 발생 오염입자 실시간 모니터링을 위한 에어로졸-레이저 유도 플라즈마 분광분석 시스템 개발)

  • Kim, Gibaek;Kim, Kyoungtae;Maeng, Hyunok;Lee, Hae Bum;Park, Kihong
    • Particle and aerosol research
    • /
    • v.12 no.3
    • /
    • pp.57-63
    • /
    • 2016
  • The laser-induced breakdown spectroscopy (LIBS) has been used for rapid detection of elemental compositions of various materials in multi-media (solid, liquid, gas, and aerosols). In this study, the aerosol-LIBS has been developed for real-time monitoring of process-induced particles produced during the semiconductor manufacturing. The developed aerosol-LIBS mainly consists of laser, optics, spectrometer, and aerosol chamber. A new aerosol chamber was constructed for the aerosol-LIBS to be applied for various semiconductor manufacturing process, including exhaust tubes, and low pressure and high temperature chamber. The aerosol-LIBS was evaluated by using laboratory generated aerosols for detection of various elements. As a result, P, Fe, Mg, Cu, Co, Ni, Ca, Na, and K emission lines were successfully detected by the aerosol-LIBS. Further evaluation of the aerosol-LIBS is being conducted.

Brownian Coagulation of Fractal Agglomerates in the Free-molecule Regime (자유분자영역에서 프랙탈 입자의 브라운 응집에 관한 연구)

  • 박성훈;이규원
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2001.11a
    • /
    • pp.395-396
    • /
    • 2001
  • 고온의 산업공정에서 발생하는 에어로졸 입자들은 많은 기본입자(primary particle)들로 이루어진 불규칙한 사슬구조를 가진다 (Matsoukas and Friedlander, 1991). 이러한 비구형 프랙탈 입자들의 거동은 구형 입자들과 비교할 때 큰 차이를 보인다. 프랙탈 입자들의 부피는 충돌반경의 거듭제곱으로 나타낼 수 있으며, 프랙탈 차원이라 불리는 그 지수는 1에서 3 사이의 값을 가진다. 자유분자영역에서의 브라운 응집에 대한 해석해는 Lee et al.(1990)에 의해 제시된 바 있으나, 이는 구형입자를 가정한 결과였고, 비구형 프랙탈 입자의 거동을 해석하려 할 때는 이로 인한 오차가 발생하게 된다. (중략)

  • PDF

Development of stratospheric Lidar for observation of volcano aerosols in the stratosphere over Korea (한반도 성층권 에어로졸 관측을 위한 성층권 라이다 개발)

  • Shin, Dong Ho;Noh, Young Min;Lee, Kwon H.;Jang, Eun Suk;Shin, Sung Kyun;Kim, Young J.
    • Korean Journal of Remote Sensing
    • /
    • v.29 no.5
    • /
    • pp.581-588
    • /
    • 2013
  • We developed the three channel lidar system to measure stratospheric aerosols at the Gwangju Institute for Science and Technology (GIST), a suburban site in Republic of Korea. The system provides backscatter coefficient (${\beta}$) at 532 and 1064 nm as well as depolarization ratios (${\delta}$) at 532 nm ($2{\beta}+1{\delta}$) using the doubled Nd:YAG laser wavelength at 532 and 1064 nm. The lidar system is optimized to measure stratospheric aerosols such as volcanic ashes. This paper describes the details of the optical setup, data acquisition system, and analysis method. This study shows an example of measuring stratospheric aerosols emitted by the volcanic eruption which occurred in Mt. Nabro ($13.37^{\circ}$ N, $41.70^{\circ}$ E).

Generation of Bi-modal Particles for Performance Evaluation of Air Cleaning Devices for Submicron Aerosols (나노/서브마이크론 에어로졸의 집진성능평가를 위한 이중모드 입자의 발생)

  • 지준호;황정호
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.97-98
    • /
    • 2003
  • 나노/서브마이크론 크기의 입자는 최근 유해 입자상 물질 제거 및 오염 제어나 물질 제조 등의 분야에서 관심이 높아지고 있다. 보통 환경 입자상 물질로 불리는 0.1~l $\mu\textrm{m}$ 범위의 서브마이크론 입자는 자동차, 공장, 발전소, 소각로 등의 연소 과정에서 발생되어 상당량이 대기로 배출되는데, 인체에 유입되면 호흡기 장애나 암을 유발하는 등의 나쁜 영향을 미친다. 특히, 관성력과 확산력에 의한 영향이 적고 하전 입자의 전기적인 이동도도 낮기 때문에 집진장치나 공기청정장치에서 집진효율이 가장 낮은 크기 범위이다. (중략)

  • PDF

Effects of coarse mode aerosol on the size distribution by coagulation and condensation processes (응집 및 응축과정에 의한 대기 에어로졸 크기 분포에서의 coarse mode의 영향)

  • 정창훈;김용표;이규원
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.04a
    • /
    • pp.158-159
    • /
    • 2000
  • 내기중의 입자 (aerosol)는 크게 직경이 0.01-0.1 $\mu\textrm{m}$ 대의 Aitken mode와 0.1-1 $\mu\textrm{m}$ 부근의 accumulation mode, 그리고 1 $\mu\textrm{m}$ 이상의 coarse mode로 분류할 수 있으며 대기 중에서 부유하여 서로응집(coagulation) 과 응축(condensation)풍의 과정을 겪으며 변화한다. 일반적으로 Aitken mode 의 입자들은 nucleation 둥에 의해 발생된 입자이며, accumulation mode는 Aitken mode입자간의 응집, 인위적인 배출 둥에 의하여 생성된 입자이다. Coarse mode는 주로 자연적으로 생성된 입자이며 주로 침적에 의해 제거된다. (중략)

  • PDF

Design and Performance Evaluation of Low Pressure Impactor (저압 임팩터의 설계 및 성능평가)

  • 임경수;권순박;이규원;배귀남
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.11a
    • /
    • pp.119-120
    • /
    • 2000
  • 일반적으로 다단 임팩터는 대기 에어로졸의 입경별 질량농도분포를 측정하는데 많이 사용되고 있다. 임팩터는 입자의 관성을 이용하여 기류로부터 입자를 분리하므로, 0.4 $\mu\textrm{m}$ 이하인 미세 입자의 경우 관성력이 작아 보통의 임팩터로는 입자를 분리하는데 어려움이 있다. 미세 입자에 대한 관심이 높아짐에 따라 저압(low pressure)이나 미세 오리피스(micro-orifice)를 사용하여 미세 입자를 분류할 수 있는 임팩터가 개발되어 사용되고 있다. (중략)

  • PDF

Modified Virtual Cyclone as a Particle Concentrator (싸이클론을 이용한 에어로졸 입자의 농축)

  • 임경수;김현수;이규원
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.11a
    • /
    • pp.483-484
    • /
    • 2003
  • 일반적으로 싸이클론은 여러 산업공정에서 입자의 분리/제어를 위해서나 대기 중의 입자상 물질을 측정하기 위해서 많이 쓰여 왔다. 하지만 싸이클론은 작은 입자에 대해서는 효율이 낮고, 완만한 포집 효율 곡선을 가지고 있기 때문에, 고효율을 얻거나 이상적인 효율 곡선을 얻는 방법에 대해서 많은 연구가 집중되었다. 최근에는 입자를 분리/포집하기 위해서 싸이클론을 사용하는 것뿐만 아니라, 일정 크기의 입자를 분리하고 농축하기 위해서 가상 싸이클론(virtual cyclone)을 사용하는 연구가 진행되고 있다. (중략)

  • PDF

Particle Emission Characteristics and Measurement of Ultrafine Particles from Laser Printer (사무용기기에서 발생되는 미세입자 측정 및 분석방법 연구)

  • Lee, Kyung Hwan;Kim, Sun Man;Ahn, Kang-Ho
    • Particle and aerosol research
    • /
    • v.6 no.3
    • /
    • pp.123-129
    • /
    • 2010
  • As the indoor activity increases in recent years, the indoor air quality becomes more important. One of the major contaminants in office space is the copy machines and the laser based printers. These devices usually emit nano-particles and chemical species that may give some health effect. The amount of particles generated by the printers and copy machines depend on printer models, printing speed, toners, papers, humidity and so on. To evaluate the emission rate of nano-particles from Laser Printers, the mass concentration measurement method has been used (BAM, 2004). However, the mass concentration measurement method for nano-particles is tedious and time consuming. Therefore, for the development of a new nano-particle counting method, the nano-particle emission characteristics and size distributions are evaluated.