• Title/Summary/Keyword: 에너지 스팩트럼

Search Result 11, Processing Time 0.027 seconds

Performance of Battery-less Backscatter Sensor Networks Based on Good Channel Sensing (채널 센싱 기반의 무전원 백스케터 센서 네트워크의 성능)

  • Hong, Seung Gwan;Sim, Isaac;Hwang, Yu Min;Kim, Jin Young
    • Journal of Satellite, Information and Communications
    • /
    • v.11 no.3
    • /
    • pp.6-11
    • /
    • 2016
  • In this paper, we studied a spectrum sensing algorithm for the efficient use of available spectrum in RF energy harvesting system combined with backscatter communication. We first looked for white spaces and then, selected low fading channel among white spaces using spectrum sensing algorithm at a transmitter. The transmitter employing the algorithm alleviates signal interference and improves the received signal strength indication through signals transmitted by low fading channel. The proposed RF energy harvesting system combined with backscatter communication is used the transmitter employing the algorithm. As a result of computer simulations, we can find the performance improvements of RF energy harvesting, BER of backscatter communication, and the received signal strength per distance of backscatter tag.

A study on the identification of turquoise by FT-IR (FT-IR을 이용한 터키석의 감별에 관한 연구)

  • Kim Young-Chool
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.14 no.6
    • /
    • pp.272-276
    • /
    • 2004
  • Inorganic materials, including gemstones, also have characteristic vibrational energies in the infrared that can be used for identification. For infrared spectroscopy, absorptions associated with the vibrations of the crystal structure (lattice vibrations) are characteristic of the given combination of atoms constituting the gemstone. Natural turquoise $CuAl_6(PO_4)_4\cdot(OH)_8\cdot 5H_2O$ can be distinguished easily from its common substitutes in the infrared range 2000~450$\textrm{cm}^{-1}$ by features in the mid-infrared. Gilson turquoise, which is a synthetic, exhibits a significantly smoother pattern when compared with natural turquoise, because of a different state of aggregation. Also, because the natural turquoise and gibbsite are so different chemically, their patterns are very different. The technique, which is infrared spectroscopy, is nondestructive and, with Fourier transform instrumentation, extremely rapid.

Response of the Wave Spectrum to Turning Winds (풍향 변화에 대한 파랑 스펙트럼의 반응)

  • 윤종태
    • Journal of Ocean Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.111-121
    • /
    • 1997
  • The spectral energy balance model is composed and the nonlinear interaction is approximated by the discrete interaction parameterization as in WAM model. The numerical results of durational limited growth test agree very well with those of the exact model, EXACT-NL. The response of a wave spectrum to a change in wind direction is investigated numerically for a sequence of direction changes 30$^{\circ}$ , 45$^{\circ}$ , 60$^{\circ}$ , 90$^{\circ}$ . The high frequency components relax more repidly to the new wind direction than the low frequency components and the relaxation process also depends on the wave age. For wind direction changes less than 60$^{\circ}$ , the coupling by nonlinear interaction is so strong that the secondary peak in input source distribution is counteracted by the negative lobe of the nonlinear interaction. For wind direction changes grater than 60$^{\circ}$ , a second independent wind-sea spectrum is generated in the new wind direction, while the old spectrum gradually decays as swell.

  • PDF

Cancellation of MRI Artifact due to Planar Respiratory Motion (호흡운동에 기인한 MRI 아티팩트의 제거)

  • 김응규;김규헌
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2003.04c
    • /
    • pp.172-174
    • /
    • 2003
  • 화상평면내 미지호흡운동에 기인한 MRI 아티팩트를 제거하기 위한 후처리방법을 제안한다. 본 연구에서 호흡운동은 2차원의 선형확대축소운동으로 모델화 된다. 신체조직을 비압축성 유체모양의 물질로 가정할때, 화상위에서의 단위체적당 푸로톤 밀도는 일정하다고 가정한다. 사용한 모델에 따르면 호흡운동은 위상 오차와 비균일표본화 및 왜곡된 진폭변조를 MR 데이터에 부여한다. 운동 파라메타가 이미 알려져 있거나 추정 가능하다고 할 때, MRI 아티팩트를 제거하기 위하여 중첩법에 기초를 둔 재구성 알고리즘을 이용한다. 운동 파라매타가 미지인 경우 스팩트럼 이동법을 적용해서 호흡변동함수와 x 방향 확대계수 및 x 방향 확대중심을 추정한다. 다음으로 에너지 최소법을 이용해서 y 방향 확대계수 및 y 방향 확대중심을 추정한다. 시뮬레이션을 통해서 제안한 방법의 유효성을 확인한다.

  • PDF

이온빔 보조 증착으로 제조된 카본 박막의 특성 연구

  • 손민규;박형국;손영호;박노길;정재인
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.132-132
    • /
    • 1999
  • 카본 박막은 내마모성, 내산성, 윤활성 및 높은 경도를 가지고 있어, 경질 박막 및 기능성 박막으로 주목을 받고 있으며 그 응용 분야가 매우 크다. 본 연구는 전자빔(Electron Beam)을 카본 grain을 증발시킴과 동시에 아르곤 보조 이온빔을 조사시켜 이온에너지에 따른 박막의 물성변화를 관찰하였다. 특히 본 연구에서 이용한 이온빔 증착 장치의 장점은 이온 충돌 에너지의 조절이 가능하다는 것이다. 카본 박막의 제조는 이온빔이 증착된 고진공 증착 장치를 이용하였고 이원빔원으로는 Oxford Applied Research 사의 RF 방전형 이온빔을 이용하였다. 배기장치는 유회전펌프와 터보펌프를 사용하였다. 기판은 홀더에 장착하기 전에 전처리를 거친 후 용기 내에서 이온빔에 의해 2차 청정을 하였다. 빔전압이 500V, 빔 전류는 4mA/cm2 및 RF power를 400W로 하여 기판 청정을 거친 후 전자빔을 이용하여 흑연을 증발시켜 박막을 제조하였다. 이때 이온빔 전압을 100~500V, RF power를 400~550W 으로 조절하였다. 카본 grain을 Si 및 Slide Glass 기판위에 1$\AA$/sec의 증착율을 유지하면서 증착하였다. 카본 박막의 박막은 평균두께는 0.3~0.4$\mu\textrm{m}$이며 SEM을 이용하여 단면을 관찰하였다. 라만 분광분석을 통하여 비정질 카본 박막의 결합특성을 조사하였고 scratch tester를 이용하여 박막의 밀착력을 관찰하였다. 그리고 카본 박막의 전도도 특성을 알고자 비저항을 측정하였으며, 박막의 성분 분석을 위한 AES 분석을 하였다. 1)AES 결과:표면에서와 박막 내부에서는 불순물인 산소나 질소의 함량이 거의 존재하지 않음을 관찰하였다. 2)경도:1,000~1,400kg/mm2 3)라만 분광 분석:300V의 이온 에너지를 분기로 박막 구조의 변화에 의한 스팩트럼의 변화를 보였다. 4)비저항:10-2~10-1$\Omega$.cm

  • PDF

Measurement of OH radical spectrum in counterflow burner using degenerate four wave mixing (DFWM(degenerate four wave mixing)을 이용한 대향류버너 화염내의 OH 라디칼 스펙트럼 측정)

  • 이은성;한재원
    • Korean Journal of Optics and Photonics
    • /
    • v.7 no.2
    • /
    • pp.142-149
    • /
    • 1996
  • In non-saturation region, we measured the degenerate four wave mixing spectra of $X^2\;{\Pi}(v=0){\to}A^2{\Sigma}^+(v'=0)$ transition for OH in counterflow burner, which exists transiently in combustion reaction. We used forward box type geometry for phase matching. Calculating the population of each rotational level from the line intensities of R$_1$band and comparing it with Boltzmann distributions, we could obtain the temperatures of the flame at several points. Corrected for the absorption of incident laser fields, the final temperatures coincided with those measured by coherent anti-Stokes Raman Scattering within error $\pm$60 K near 2000 K. We also measured the concentration distribution of OH radical and it was compared to that measured by laser induced fluorescence.

  • PDF

Compare the Clinical Tissue Dose Distributions to the Derived from the Energy Spectrum of 15 MV X Rays Linear Accelerator by Using the Transmitted Dose of Lead Filter (연(鉛)필터의 투과선량을 이용한 15 MV X선의 에너지스펙트럼 결정과 조직선량 비교)

  • Choi, Tae-Jin;Kim, Jin-Hee;Kim, Ok-Bae
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.80-88
    • /
    • 2008
  • Recent radiotherapy dose planning system (RTPS) generally adapted the kernel beam using the convolution method for computation of tissue dose. To get a depth and profile dose in a given depth concerened a given photon beam, the energy spectrum was reconstructed from the attenuation dose of transmission of filter through iterative numerical analysis. The experiments were performed with 15 MV X rays (Oncor, Siemens) and ionization chamber (0.125 cc, PTW) for measurements of filter transmitted dose. The energy spectrum of 15MV X-rays was determined from attenuated dose of lead filter transmission from 0.51 cm to 8.04 cm with energy interval 0.25 MeV. In the results, the peak flux revealed at 3.75 MeV and mean energy of 15 MV X rays was 4.639 MeV in this experiments. The results of transmitted dose of lead filter showed within 0.6% in average but maximum 2.5% discrepancy in a 5 cm thickness of lead filter. Since the tissue dose is highly depend on the its energy, the lateral dose are delivered from the lateral spread of energy fluence through flattening filter shape as tangent 0.075 and 0.125 which showed 4.211 MeV and 3.906 MeV. In this experiments, analyzed the energy spectrum has applied to obtain the percent depth dose of RTPS (XiO, Version 4.3.1, CMS). The generated percent depth dose from $6{\times}6cm^2$ of field to $30{\times}30cm^2$ showed very close to that of experimental measurement within 1 % discrepancy in average. The computed dose profile were within 1% discrepancy to measurement in field size $10{\times}10cm$, however, the large field sizes were obtained within 2% uncertainty. The resulting algorithm produced x-ray spectrum that match both quality and quantity with small discrepancy in this experiments.

  • PDF

Preprocessing of Transmitted Spectrum Data for Development of a Robust Non-destructive Sugar Prediction Model of Intact Fruits (과실의 비파괴 당도 예측 모델의 성능향상을 위한 투과스펙트럼의 전처리)

  • Noh, Sang-Ha;Ryu, Dong-Soo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.4
    • /
    • pp.361-368
    • /
    • 2002
  • The aim of this study was to investigate the effect of preprocessing the transmitted energy spectrum data on development of a robust model to predict the sugar content in intact apples. The spectrum data were measured from 120 Fuji apple samples conveying at the speed of 2 apples per second. Computer algorithms of preprocessing methods such as MSC, SNV, first derivative, OSC and their combinations were developed and applied to the raw spectrum data set. The results indicated that correlation coefficients between the transmitted energy values at each wavelength and sugar contents of apples were significantly improved by the preprocessing of MSC and SNV in particular as compared with those of no-preprocessing. SEPs of the prediction models showed great difference depending on the preprocessing method of the raw spectrum data, the largest of 1.265%brix and the smallest of 0.507% brix. Such a result means that an appropriate preprocessing method corresponding to the characteristics of the spectrum data set should be found or developed for minimizing the prediction errors. It was observed that MSC and SNV are closely related to prediction accuracy, OSC is to number of PLS factors and the first derivative resulted in decrease of the prediction accuracy. A robust calibration model could be d3eveloped by the combined preprocessing of MSC and OSC, which showed that SEP=0.507%brix, bias=0.0327 and R2=0.8823.

Readeveloping Turbulent Boundary Layer after Separation-Reattachment(I) (박리-재부착 이후의 재발달 난류경계층 I)

  • 백세진;유정열
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.4
    • /
    • pp.780-788
    • /
    • 1989
  • An experimental study has been performed to investigate the process from nonequilibrium state to equilibrium state in redeveloping turbulent boundary layer beyond separation-reattachment using pitot tube and hot-wire anemometer. The model sued in the experiment has the form of a backward facing step which is assembled by a two-dimensional 4:1 half elipse and a plate. Measurements are carried out up to a distance of about 50 step height downstream of the step, where the reattachment observed at about x/h=6.5. The profiles of the shape factor H the Clauser parameter G and the coefficient of friction $C^{f}$ exhibited the characteristics similar to those of the equilibrium turbulent boundary layer from x/h=25, and the profiles of the trubulent quantities did from x/h=35. However, the wake region of the boundary layer does not seem to recover the equilibrium turbulent boundary layer even at x/h=50. By considering the distributions of the intermittency factor it has been noted that the turbulence structure changes gradually from a mixing layer to a turbulent boundary layer along downstream direction after reattachment. This becomes clearer as we analyse the one-dimensional energy spectra and the dissipation energy spectra which are measured and caculated at various downstream positions after the backward facing step.p.

Evaluation of Filter Media for Use in Alpha Measurement of Radon Progeny (라돈 자핵종의 알파 측정용 여과지 매질의 평가)

  • Seo, Kyung-Won;Knutson Earl O.
    • Journal of Radiation Protection and Research
    • /
    • v.17 no.1
    • /
    • pp.31-41
    • /
    • 1992
  • A study for the evaluation of selected filter media that need further characterization particularily in the context of alpha measurements of radon progeny has been carried out by investigating physical characteristics and using the alpha spectroscopy. Physical characteristics was investigated by electrostatic charging and mechanical strength of filters, and then pressure drop before and after sampling was tested. Alpha spectroscopy was used to analyze the energy spectra from the deposition of radon progeny into filters. The results of the assessment showed that the newer filter types do not have a great advantage over the 'old standard' Millipore type AA. But Metricel DM-800 is recommended for those situations where electrostatic charging is a problem. Also this method will be used more effective for the evaluation of new developing filters in future.

  • PDF