• Title/Summary/Keyword: 에너지 기여도 평가

Search Result 1,100, Processing Time 0.034 seconds

The Study of Muscle Strength and Dietary Quality of the Korean Elderly: Based on the 2014-2018 Korea National Health and Nutrition Examination Survey (한국 노인의 근력과 식사의 질에 대한 연구: 2014-2018년 국민건강영양조사 자료를 이용하여)

  • Kim, Jin-A;Lee, Sim-Yeol
    • Journal of Korean Home Economics Education Association
    • /
    • v.34 no.1
    • /
    • pp.113-129
    • /
    • 2022
  • This study evaluated the dietary habits and dietary quality of the Korean elderly according to muscle strength status. This study was conducted on the elderly aged over 65 years who participated in the 2014-2018 Korea National Health and Nutrition Examination Survey. Subjects were classified into the normal muscle strength group(n=2,000) and the low muscle strength group(n=1,273) according to the handgrip strength. There was a significant difference in general characteristics, diet habits, and health behavior according to the muscle strength status. The normal muscle strength group had a higher total score of KHEI and a subtotal score of 「adequacy」 items. But there was not significant difference in the 「moderation」 items. For the 「balance of energy intake」 items, the normal muscle strength group had a higher subtotal score than the low muscle strength group only in among women. The prevalence of low muscle strength decreased in the highest quartile of the adjusted KHEI total score(p for trend=0.08). As a result of this study, it was found that KHEI was significantly associated with muscle strength. This study result can be used to provide dietary guidelines for the improvement of muscle strength in the elderly based on each item of KHEI and sex.

Application of PLA/PBAT Composite Films Containing Calcined Oyster Shell Powder for Antimicrobial Packaging (소성 처리된 굴 패각을 활용한 PLA/PBAT 복합필름의 항균 포장재 적용 연구)

  • Yena Oh;Kitae Park;Jongchul Seo
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.29 no.2
    • /
    • pp.79-86
    • /
    • 2023
  • In this study, poly(lactic acid) (PLA) and Poly(butylene-adipate-co-terephthalate) (PBAT) composite films containing calcined oyster shell powder (OSP) were evaluated for the applicability of antimicrobial packaging. PLA/PBAT-OSP composite films were prepared using twin-screw extruder. The OSP composite was incorporated into PLA/PBAT blend with different ratios (0, 1, 3, 5 and 10%) and the effect of OSP in the PLA/PBAT matrix was evaluated. The PLA/PBAT-OSP composite films were evaluated for properties using FT-IR, SEM, TGA, DSC, UTM, UV-vis, and Contact angle, as well as antimicrobial property was examined according to ISO 22196 - Antimicrobial Plastic Test. As OSP was added, it showed high antimicrobial activities for both Gram-positive (Staphylococcus aureus) and Gram-negative (Escherichia coli) bacteria. On the other hand, it was found that mechanical properties decreased as OSP was added. For the application of PLA/PBAT-OSP composite films as an antimicrobial packaging material, it is necessary to improve the dispersibility of OSP in the PLA/PBAT composite films and their physical properties at the same time.

Naturopathic Effects of Arthritis, Frozen Shoulder and Lumbago Using the Qi-Therapy (관절염, 오십견 및 요통에 대한 기(氣)치유 효과)

  • Kim, Munki;Lee, Hyung Hoan
    • Journal of Naturopathy
    • /
    • v.8 no.2
    • /
    • pp.53-62
    • /
    • 2019
  • Purpose: To investigate the healing effect of 21 patients with chronic back pain, shoulder pain, and knee arthritis by a Qigong. Methods: The study performed by hand injection of a Soojung Qi-therapy. Results: Ten patients (47.6%) had low back pain, eight (38%) had frozen shoulders, and three (14.3%) had knee arthritis. Satisfaction after five times of the Qi-healing was 72% in those who returned to normal and 14% in those who improved. When the maximum pain level set at 5.0, the difference between before and after healing was 3.33 in arthritis subjects, 3.75 in fifty shoulder subjects, and 3.80 in low back pain. In general, the degree of pain decreased as the number of healings increased. In particular, even after the first healing, the pain reduction of the subjects was high in arthritis, frozen shoulders, and low back pain. That is, there was a possibility of controlling pain with only one Qi-healing. Conclusions: Soojung Qi-therapy is one of the natural healing treatments because it reduces fast pains and accessible to handling anytime and anywhere. Conclusions: With Qi-therapy, arthritis, frozen shoulder, and lumbago patients almost recovered to their original shape. Therefore, Qi-therapy regarded as one of the useful natural healing therapies.

Effect of Low-intensity Resistance Training with Blood Flow Restriction on Muscle Volume and Strength in Elderly Women (저강도의 저항성 운동 시 혈류제한 적용이 노인여성의 근 비대와 근력 향상에 미치는 영향)

  • Yeo, Hyo-Seong;Kim, Hyo-Jeong
    • 한국체육학회지인문사회과학편
    • /
    • v.54 no.1
    • /
    • pp.535-544
    • /
    • 2015
  • This study was performed to determine the effect of low-intensity resistance training with blood flow restriction (BFR) on muscle volume and strength in elderly women. Sixteen elderly women (70.9±4.6 years) were divided into low (30% 1RM) and high (75% 1RM) intense resistance training groups. Tourniquet cuff (Zimmer, Germany) for BFR was applied only to the right leg during the training period. All subjects performed unilateral leg press, leg extension and leg curl (3 sets×12 repetitions) for 10 weeks (2d/wk). Blood pressure was increased from 110 to 240 mmHg during the training period at the most proximal region of exercised leg. Muscle volume and cross-sectional area (CSA) were measured by MRI and body composition was monitored by dual-energy X-ray absorptiometry (DEXA) and isokinetic muscular strength were analyzed in both legs. The quadriceps CSA (15.2%, p<.001) and muscle volume (13.8%, p<.001) were increased in high-intense trained leg with BFR and the increased rate was highest among groups. The quadriceps CSA (9.8%, p<.001) and muscle volume (6.9%, p<.001) were increased in low-intensity training group with BFR and their increased rates were higher than control groups. The strength by exercise training was significantly improved in all groups and tended to be higher in BFR groups. These results demonstrate low-intensity resistance training with blood flow restriction could be an effective way to improve muscle volume and strength in elderly women.

Generalization of an Evaluation Formula for Bearing Pressures on the Rubble Mound of Gravity-Based Harbor Structures (중력식 항만구조물의 사석마운드 지반반력 평가식의 일반화)

  • Woo-Sun Park
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.35 no.6
    • /
    • pp.128-137
    • /
    • 2023
  • In this study, the bearing pressure on the rubble mound of a gravity-based harbor structure with an arbitrarily shaped bottom was targeted. Assuming that the bottom of the structure is a rigid body, the rubble mound was modeled as a linear spring uniformly distributed on the bottom that resists compression only, and the bearing pressure evaluation formula was derived. It was confirmed that there were no errors in the derivation process by showing that when the bottom was square, the derived equation was converted to the equation used in the design. In addition, the validity of the derived equation was proven by examining the behavior and convergence value of the bearing pressure when an arbitrarily shaped bottom converges into a square one. In order to examine the adequacy of the method used in the current design, the end bearing pressure for the pre-designed breakwater cross-section was calculated and compared with the values in the design document. As a result, it was shown that the method used for design was not appropriate as it gave unsafe results. In particular, the difference was larger when the eccentricity of the vertical load was large, such as in the case of extreme design conditions.

Recent Progress in Micro In-Mold Process Technologies and Their Applications (마이크로 인몰드 공정기술 기반 전자소자 제조 및 응용)

  • Sung Hyun Kim;Young Woo Kwon;Suck Won Hong
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.30 no.2
    • /
    • pp.1-12
    • /
    • 2023
  • In the current era of the global mobile smart device revolution, electronic devices are required in all spaces that people interact with. The establishment of the internet of things (IoT) among smart devices has been recognized as a crucial objective to advance towards creating a comfortable and sustainable future society. In-mold electronic (IME) processes have gained significant industrial significance due to their ability to utilize conventional high-volume methods, which involve printing functional inks on 2D substrates, thermoforming them into 3D shapes, and injection-molded, manufacturing low-cost, lightweight, and functional components or devices. In this article, we provide an overview of IME and its latest advances in application. We review biomimetic nanomaterials for constructing self-supporting biosensor electronic materials on the body, energy storage devices, self-powered devices, and bio-monitoring technology from the perspective of in-mold electronic devices. We anticipate that IME device technology will play a critical role in establishing a human-machine interface (HMI) by converging with the rapidly growing flexible printed electronics technology, which is an integral component of the fourth industrial revolution.

Development and Characterization of Hafnium-Doped BaTiO3 Nanoparticle-Based Flexible Piezoelectric Devices (Hf 도핑된 BaTiO3 나노입자 기반의 플렉서블 압전 소자 개발 및 특성평가)

  • HakSu Jang;Hyeon Jun Park;Gwang Hyeon Kim;Gyoung-Ja Lee;Jae-Hoon Ji;Donghun Lee;Young Hwa Jung;Min-Ku Lee;Changyeon Baek;Kwi-Il Park
    • Journal of Sensor Science and Technology
    • /
    • v.33 no.1
    • /
    • pp.34-39
    • /
    • 2024
  • Energy harvesting technology that converts the wasted energy resources into electrical energy is emerging as a semipermanent power source for self-powered electronics and wireless low-power sensor systems. Among the various energy conversion techniques, flexible piezoelectric energy harvesters (f-PEHs), using materials with piezoelectric effects, have attracted significant interest because they can harvest a small mechanical energy into electrical signals without constraints of time and space in various environments. In this study, we used a flexible piezoelectric composite film fabricated by dispersing BaHfxTi(1-x)O3 (x = 0, 0.01, 0.05, 0.1) piezoelectric powders inside a polymeric matrix to facilitate f-PEHs. The fabricated f-PEH with optimal Hf contents (x = 0.05) generated a maximum output voltage of 0.95 V and current signal of 130 nA with stable electrical/mechanical disabilities under periodically bending deformations. In addition, we demonstrated a cantilever-type f-PEH and investigated its potential as a sensor by characterizing the output performance under mechanical vibrations at various frequencies. This study provides the breakthrough for realizing self-powered energy harvesting and sensing systems by adopting the lead-free piezoelectric composites under vibrational environments.

Comparison of using CBCT with CT Simulator for Radiation dose of Treatment Planning (CBCT와 Simulation CT를 이용한 치료계획의 선량비교)

  • Kim, Dae-Young;Choi, Ji-Won;Cho, Jung-Keun
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.742-749
    • /
    • 2009
  • The use of cone-beam computed tomography(CBCT) has been proposed for guiding the delivery of radiation therapy. A kilovoltage imaging system capable of radiography, fluoroscopy, and cone-beam computed tomography(CT) has been integrated with a medical linear accelerator. A standard clinical linear accelerator, operating in arc therapy mode, and an amorphous-silicon (a-Si) with an on-board electronic portal imager can be used to treat palliative patient and verify the patient's position prior to treatment. On-board CBCT images are used to generate patient geometric models to assist patient setup. The image data can also, potentially, be used for dose reconstruction in combination with the fluence maps from treatment plan. In this study, the accuracy of Hounsfield Units of CBCT images as well as the accuracy of dose calculations based on CBCT images of a phantom and compared the results with those of using CT simulator images. Phantom and patient studies were carried out to evaluate the achievable accuracy in using CBCT and CT stimulator for dose calculation. Relative electron density as a function of HU was obtained for both planning CT stimulator and CBCT using a Catphan-600 (The Phantom Laboratory, USA) calibration phantom. A clinical treatment planning system was employed for CT stimulator and CBCT based dose calculations and subsequent comparisons. The dosimetric consequence as the result of HU variation in CBCT was evaluated by comparing MU/cCy. The differences were about 2.7% (3-4MU/100cGy) in phantom and 2.5% (1-3MU/100cGy) in patients. The difference in HU values in Catphan was small. However, the magnitude of scatter and artifacts in CBCT images are affected by limitation of detector's FOV and patient's involuntary motions. CBCT images included scatters and artifacts due to In addition to guide the patient setup process, CBCT data acquired prior to the treatment be used to recalculate or verify the treatment plan based on the patient anatomy of the treatment area. And the CBCT has potential to become a very useful tool for on-line ART.)

Comparison of using CBCT with CT simulator for radiation dose of treatment planning (CBCT와 Simulation CT를 이용한 치료계획의 선량비교)

  • Cho, jung-keun;Kim, dae-young;Han, tae-jong
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.1159-1166
    • /
    • 2009
  • The use of cone-beam computed tomography(CBCT) has been proposed for guiding the delivery of radiation therapy. A kilovoltage imaging system capable of radiography, fluoroscopy, and cone-beam computed tomography(CT) has been integrated with a medical linear accelerator. A standard clinical linear accelerator, operating in arc therapy mode, and an amorphous-silicon (a-Si) with an on-board electronic portal imager can be used to treat palliative patient and verify the patient's position prior to treatment. On-board CBCT images are used to generate patient geometric models to assist patient setup. The image data can also, potentially, be used for dose reconstruction in combination with the fluence maps from treatment plan. In this study, the accuracy of Hounsfield Units of CBCT images as well as the accuracy of dose calculations based on CBCT images of a phantom and compared the results with those of using CT simulator images. Phantom and patient studies were carried out to evaluate the achievable accuracy in using CBCT and CT stimulator for dose calculation. Relative electron density as a function of HU was obtained for both planning CT stimulator and CBCT using a Catphan-600 (The Phantom Laboratory, USA) calibration phantom. A clinical treatment planning system was employed for CT stimulator and CBCT based dose calculations and subsequent comparisons. The dosimetric consequence as the result of HU variation in CBCT was evaluated by comparing MU/cCy. The differences were about 2.7% (3-4MU/100cGy) in phantom and 2.5% (1-3MU/100cGy) in patients. The difference in HU values in Catphan was small. However, the magnitude of scatter and artifacts in CBCT images are affected by limitation of detector's FOV and patient's involuntary motions. CBCT images included scatters and artifacts due to In addition to guide the patient setup process, CBCT data acquired prior to the treatment be used to recalculate or verify the treatment plan based on the patient anatomy of the treatment area. And the CBCT has potential to become a very useful tool for on-line ART.)

  • PDF

Monte Carlo Study Using GEANT4 of Cyberknife Stereotactic Radiosurgery System (GEANT4를 이용한 정위적 사이버나이프 선량분포의 계산과 측정에 관한 연구)

  • Lee, Chung-Il;Shin, Jae-Won;Shin, Hun-Joo;Jung, Jae-Yong;Kim, Yon-Lae;Min, Jeong-Hwan;Hong, Seung-Woo;Chung, Su-Mi;Jung, Won-Gyun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.192-200
    • /
    • 2010
  • Cyberknife with small field size is more difficult and complex for dosimetry compared with conventional radiotherapy due to electronic disequilibrium, steep dose gradients and spectrum change of photons and electrons. The purpose of this study demonstrate the usefulness of Geant4 as verification tool of measurement dose for delivering accurate dose by comparing measurement data using the diode detector with results by Geant4 simulation. The development of Monte Carlo Model for Cyberknife was done through the two-step process. In the first step, the treatment head was simulated and Bremsstrahlung spectrum was calculated. Secondly, percent depth dose (PDD) was calculated for six cones with different size, i.e., 5 mm, 10 mm, 20 mm, 30 mm, 50 mm and 60 mm in the model of water phantom. The relative output factor was calculated about 12 fields from 5 mm to 60 mm and then it compared with measurement data by the diode detector. The beam profiles and depth profiles were calculated about different six cones and about each depth of 1.5 cm, 10 cm and 20 cm, respectively. The results about PDD were shown the error the less than 2% which means acceptable in clinical setting. For comparison of relative output factors, the difference was less than 3% in the cones lager than 7.5 mm. However, there was the difference of 6.91% in the 5 mm cone. Although beam profiles were shown the difference less than 2% in the cones larger than 20 mm, there was the error less than 3.5% in the cones smaller than 20 mm. From results, we could demonstrate the usefulness of Geant4 as dose verification tool.