• Title/Summary/Keyword: 에너지소산능력

Search Result 225, Processing Time 0.021 seconds

Seismic Performance Evaluation of R/C Different Floor Type Interior Beam-Column Joints in the Middle and High-rise Mixed-use Residential Building (중.고층 주상복합 R/C 건축물의 단차형 내부 보-기둥 접합부 내진성능평가)

  • Ha, Gee-Joo;Shin, Jong-Hak;Huh, Mean-Haeng;Hong, Kun-Ho;Ha, Jae-Hoon;Nam, Young-Sik
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.453-454
    • /
    • 2009
  • In this dissertation, experimental program was carried out to study the hysteretic behavior of the reinforced different floor type interior beam-column joint repeated cyclic loads under seismic actions. The test results was as follow. The reinforced interior beam-column joint, designed by the different floor type, was increased energy dissipation capacity and maximum load carrying capacity according to the increase of different floor in comparison to standard specimen. And it was also dissimilar to failure mode adjacent to joint region. energy dissipation capacity of each specimen, designed by the different floor type, was increased 1.1${\sim}$1.35 times in comparison to standard specimen.

  • PDF

An Experimental Study on the Seismic Performance of RC Frames with Steel Dampers (강재댐퍼로 보강된 철근콘크리트 골조의 내진성능 실험 연구)

  • Park, Ji-Young
    • Land and Housing Review
    • /
    • v.1 no.1
    • /
    • pp.43-50
    • /
    • 2010
  • In this study, the influences of steel dampers on the behavior of RC frames were investigated using the experimental approach to suggest the installation methods of steel dampers using K-barces. The performances of RC frames with dampers can be evaluated by superposition the load-displacement curves of RC frames and steel dampers with regard to the influences of K-braces. Three specimens are tested to investigate the cyclic behavior of RC frames with dampers. The performances of RC frames with dampers with respect to strength, rigidity, and hysteretic performance are examined. It was found that test results demonstrates the effect of seismic retrofit on RC frames with steel dampers(D-RCF-KBSF, D-RCF-KBSP) compared with RC frames(N-RCF). An approximate design curves may not be good agreement with those of the tests, it is conservative enough so that you can design of RC frames with steel damper with regard to the influences of K-braces.

Optimal Seismic Design Method Based on Genetic Algorithms to Induce a Beam-Hinge Mechanism in Reinforced Concrete Moment Frames (철근콘크리트 모멘트골조의 보-힌지 붕괴모드를 유도하는 유전자알고리즘 기반 최적내진설계기법)

  • Se-Woon Choi
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.36 no.6
    • /
    • pp.399-405
    • /
    • 2023
  • This study presents an optimal seismic design method based on genetic algorithms to induce beam-hinge collapse mechanisms in reinforced concrete moment frames. Two objective functions are used. The first minimizes the cost of the structure and the second maximizes the energy dissipation capacity of the structure. Constraints include strength conditions of columns and beams, minimum conditions for column-to-beam flexural strength ratio, and conditions for preventing plastic hinge occurrence of columns. Linear static analysis is performed to evaluate the strength of members, whereas nonlinear static analysis is carried out to evaluate energy dissipation capacity and occurrence of plastic hinges. The proposed method was applied to a four-story example structure, and it was confirmed that solutions for inducing a beam-hinge collapse mechanism are obtained. The value of the column-beam flexural strength ratio of the obtained design was found to be larger than the value suggested by existing seismic codes. A more robust strategy is needed to induce a beam-hinge collapse mode.

Seismic Performance of Internally Confined Hollow RC Column with Corrugated Steel Tube (파형강관 내부 구속 중공 철근 콘크리트 기둥의 내진 성능)

  • Han, Taek-Hee;Kim, Jong-Min;Kang, Jun-Suk;Kang, Young-Jong
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.2
    • /
    • pp.31-38
    • /
    • 2008
  • A column test was performed far a new-type column with a quasi static test. An internally confined hollow reinforced concrete column with a corrugated steel tube (ICH RC-CT column) was tested to evaluate its seismic performance. And also, a general solid RC column was tested fur the comparison. The test was performed as planned drift levels. The lateral displacements and the lateral loads of column specimens were measured during tests. From the test results, the ICH RC-CT column showed smaller energy absorbing capacity than a solid RC column but showed the almost equal energy ductility and equivalent viscous damping ratio to those of the solid RC column.

A Protection Capacity Evaluation of Vessel Protective Structures by Quasi-Static Collision Analysis (준정적 충돌해석을 통한 선박충돌방공호의 방호능력평가)

  • Lee, Gye-Hee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.6
    • /
    • pp.691-697
    • /
    • 2011
  • In this study, the vessel collision protective structure and the vessel were modeled numerically and the quasi-static collision analysis was performed to evaluate the maximum protection capacity. In the modeling process of protective structure, the nonlinear behaviors of structure and the supporting conditions of ground including pull-out action were considered. In that of collision vessel, the bow of vessel was modeled precisely, because of the nonlinear behaviors were concentrated on it. For the efficient analysis, the mass scaling scheme was applied, also. To evaluate the differences and efficiency, the dynamic analyses were performed for the same model, additionally. Based on the obtained energy dissipation curves of the structure and the vessel, the moment that the collision force affected to the bridge substructures was determined and the maximum allowable collision velocity was evaluated. Because of the energy dissipation bound can be recognized clearly, this scheme can be used efficient in engineering work.

Seismic Performance Evaluation of Welded Beam-Column Connections abricated with SHN Steel Sections (SHN 형강 보-기둥 접합부의 내진성능 평가)

  • Kim, Tae Jin;Park, JongWon;Cho, Jeong Hyuk;Kim, Hee Dong
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.6
    • /
    • pp.829-838
    • /
    • 2008
  • In this study, cyclic tests of beam-column connections composed with members applicable to the domestic low-middle rise steel buildings were conducted to develop seismic connection details and its evaluation. Connection types and material properties of the steel were testing variables and the difference between the newly developed seismic rolled section (SHN490) and existing rolled section (SM490) was also investigated. Distributions of the yield strength and the ultimate strength of the SHN490 rolled section were relatively uniform comparing to those of the SM490 rolled section Brittle fracture in the weldments of the test specimens was not observed. Instead, fracture occurred at heat-affected zones or the stress-concentrated point near the weld access hole of the beam flanges. In the case of identical rolled-section specimens, the rotational capacity and dissipated energy of the WUF-W connection was larger than those of the WUF-B connection. In the case of identical connection types, the rotational capacity and dissipated energy of the SHN490 section connection was larger than those of the WUF-B section connection.

Seismic Performance of Precast Concrete Beam-Column Connections Using Ductile Rod (연성 강봉을 사용한 프리캐스트 콘크리트 보-기둥 접합부의 내진성능)

  • Lee, Sang-Jin;Hong, Sung-Gul;Lim, Woo-Young
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.6
    • /
    • pp.695-705
    • /
    • 2014
  • Precast concrete (PC) beam-column connections using ductile rods are proposed for earthquake zone. An existing beam-column connection, two PC specimens designed by considering failure modes and a conventional RC specimen were tested under cyclic loading to evaluate the seismic performance. The specimens were designed to satisfy the requirements of current design code. The variables are the yield strength of longitudinal reinforcing bars of PC beams. The test results showed that the proposed system applying smaller yield strength of the longitudinal reinforcing bars at the PC beams than the ductile rods was satisfied with seismic criteria. The deformation capacity and energy dissipation capacity of the proposed PC beam-column connections were greater than those of the existing DDC system.

Strengthening Effects of RC Column using Fiber Reinforced Polymer (섬유보강재를 이용한 RC 기둥의 보강 효과)

  • Lee, Hyun-Ho;Kim, Jin-Ho;Rho, Kwamg-Geun
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.4
    • /
    • pp.473-480
    • /
    • 2012
  • In order to develop an effecive seismic strengthening metghod for existing concrete structure, structural tests of aramid FRP reinforced RC columns are performed. The test variables were strengthening methods of aramid sheet and strip. The test results were evaluated by comparing strength and energy dissipation capacities of non-reinforced and reinforced specimens. The test result comparison showed that aramid sheet reinforcement on RC column was evaluated as the most efficient way to increase strength and energy dissipation capacity.

Calculation of Optimum Damping Ratio of Viscous Dampers Using Capacity Spectrum Method (능력스펙트럼법을 이용한 점성 감쇠기의 적정 감쇠비 산정)

  • 김진구;최현훈
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.1
    • /
    • pp.45-52
    • /
    • 2001
  • 에너지 소산장치가 설치된 건무의 비선형 시간이력해석은 복잡하고 많은 시간이 소모된다. 본 연구에서는 비선형 정적해석법인 능력 스펙트럼을 이용하여 구조물의 주어긴 거동 한계를 만족할 수 있는 감쇠기의 양을 산정하는 방법에 관하여 연구하였다. 먼저 능력스펙트럼법을 이용하여 건물의 비선형 정적응답을 구하고 건물의 응답과 목표변위의 차이를 이용하여 유효감쇠비를 구하고 이러한 유효 감쇠비를 이용하여 필용한 점성 감쇠기의 양을 구하였다. 본 연구에서는 단자 유도계에서 건물의 주기, 요구되는 탄성강도에 대한 항복강도의 비, 항복 후 강성비 등을 변수로 하여 연구를 수행하였다. 제안된 방법에 따라 설계된 점성 감쇠기를 설치한 예제 구조물의 시간이력 해석에 의한 최대 응답은 설계의 초기단계에서 사용한 목표변위와 잘 일치하였다.

  • PDF

Structural Behavior of Joints between the Hysteretic Steel Damper Connector and RC Wall Depending on Connection Details (강재판형 이력댐퍼 연결부재와 RC벽체의 접합상세에 따른 구조거동)

  • Kang, In-Seok;Hur, Moo-Won
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.6
    • /
    • pp.737-744
    • /
    • 2012
  • Hysteretic steel damper has been applied mainly to steel buildings. However, the usage in RC buildings is rapidly increasing recently. In order to apply the steel hysteretic damper in RC buildings, supporting elements of the damper should have sufficient strength and stiffness suitable for transferring damper forces to beams and walls. But due to the inevitable damage in reinforced concrete elements due to cracking, identification of the load transfer mechanism from damper to supporting element and hysteretic characteristics of the supporting element are extremely important in evaluating the damper behavior. Experiments were carried out on connection details between RC walls and supporting elements of the steel plate typed damper such as EaSy damper. The test results showed that fracture patterns of all specimens were almost identical except in the crack number and pattern associated with shear loading condition. Among the specimens, HD-3 shoed a well distributed cracks patterns along with good performance with respect to energy dissipation capacity, stiffness deterioration, and strength degradation.