Structural Behavior of Joints between the Hysteretic Steel Damper Connector and RC Wall Depending on Connection Details  

Kang, In-Seok (TOTAL ENC, Architecture Engineering, Hanyang University)
Hur, Moo-Won (Dept. of Architectural Engineering, Dan-kook University)
Publication Information
Journal of the Korea Concrete Institute / v.24, no.6, 2012 , pp. 737-744 More about this Journal
Abstract
Hysteretic steel damper has been applied mainly to steel buildings. However, the usage in RC buildings is rapidly increasing recently. In order to apply the steel hysteretic damper in RC buildings, supporting elements of the damper should have sufficient strength and stiffness suitable for transferring damper forces to beams and walls. But due to the inevitable damage in reinforced concrete elements due to cracking, identification of the load transfer mechanism from damper to supporting element and hysteretic characteristics of the supporting element are extremely important in evaluating the damper behavior. Experiments were carried out on connection details between RC walls and supporting elements of the steel plate typed damper such as EaSy damper. The test results showed that fracture patterns of all specimens were almost identical except in the crack number and pattern associated with shear loading condition. Among the specimens, HD-3 shoed a well distributed cracks patterns along with good performance with respect to energy dissipation capacity, stiffness deterioration, and strength degradation.
Keywords
hysteretic damper; energy dissipation; stiffness degradation; steel fiber reinforced concrete;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Lee, S. J, Park, J. S., and Oh, S. H., "A Study on the Earthquake Response Characteristics of Steel Frames with Metallic Damper," Journal of the Korean Association for Spatial Structures, Vol. 11, No. 2, 2011, pp. 119-127.   과학기술학회마을   DOI   ScienceOn
2 Matsuura, T., Inai, E., and Fujimoto, T., "A Study on Structural Performance Considering Connecting Condition of Pillar Type Hysteretic Dampers for R/C Buildings," The 14th World Conference on Earthquake Engineering, Beijing, China, 2008, ID 05-06-0053.
3 Lee, H. H., Kwon, Y. H., Hur, M. W., and Chun, Y. S., "Shear Capacity Evaluation of Steel Fiver Reinforced Concrete Beam without Stirrups Considering Material and Member Characteristic Strength," Journal of the Korea Institute for Structural Maintenance Inspection, Vol. 7, No. 2, 2003, pp. 245-250.
4 Chopra, A. K., Dynamics of Structures: Theory and Applications to Earthquake Engineering 2nd Edition, Prentice Hall, 2001, 844 pp.