• Title/Summary/Keyword: 에너지변환장치

Search Result 497, Processing Time 0.04 seconds

A Study of energy conversion by the penetration control in the skin (에너지변환을 이용한 피부의 투과조절에 관한 연구)

  • Kim, Jeong-Lae;Kim, Hye-Ju
    • The Journal of the Convergence on Culture Technology
    • /
    • v.3 no.1
    • /
    • pp.43-48
    • /
    • 2017
  • We are confirmed to the variation of the transfer condition and the functional penetration by the permitted conversion energy on the skin. The given conversion energy is consist of the flow level of penetration control and go to the processing transfer in the skin that is to create the modeling for algorithm. The energy level of control processing was achieved effectively modeling system that was the composition of auto and local control level in the epidermis-dermis layer. Their penetration pulse control system was consisted of conversion energy with reference of fixing situation and recreation of designed apparatus for the energy control function that was converted to capacity by the size, form and combination. Also, the system was shown accurately distribution of conversion at the depth of skin correction. Therefore, conversion modeling was established effectively to separate the division parts for conversion system. We will be possible to progress the improvement effectiveness of the skin and to consist of the continuous penetration control system for functional energy on the skin.

Application of 3D Picture Control to the Simulator to Visualize the Field Demonstration Data (실증 Data 시각화를 위한 풍력시스템 Simulator 3D 시각화 작업 구현)

  • Choi, Hyojin;Kim, Young Chan;Chun, Chinwha
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.187-187
    • /
    • 2010
  • 풍력을 이용한 풍력발전기의 전력변환 시스템을 연구개발하기 위해서는 바람의 특성을 실내에서 구현할 수 있는 모의시험장치인 시뮬레이터가 요구된다. 모의시험장치는 바람을 받아 회전하는 블레이드 대신 풍속 값을 입력하여 전동기가 발전기에 토오크(torque)를 공급하게 된다. POSTECH 풍력에너지연구소는 2003년 750kW급 KBP-750D 풍력발전기용 모의시험장치에 이어, 2007년 2MW Gearless형 풍력발전기(KBP-2000M)의 400:1 축소모델인 5.83kW 모의시험 장치를 제작 완료하였다. (주)플라스포사는 모의시험장치를 이용하여 고효율의 전력변환장치 설계와 인버터 시스템 제어 알고리즘을 개발하였고, (주)유니슨은 2MW 풍력발전기용 통합연동제어 시스템을 제작 완료하여 2009년부터 대관령 실증단지에 초도품을 설치하고 실증운영 중에 있다. 본 논문은 대관령 실증단지에서 실시한 2MW 풍력시스템 실증과정에서 획득한 풍향과 풍속 데이터를 시각적으로 쉽게 보고 이해할 수 있도록 3D모델 처리방안을 적용하여 모의시험 장치에 구현한 내용이다. 풍력발전기 개발은 현재 대형화 추세에 있으며 연구개발 단계에서 풍력발전기의 발전 및 제어부분의 기능적 안정성 확보와 효율성 증대를 위한 적절한 시험은 필수적이다. 그러나 풍력발전기의 특성상 타워를 건설하고 회전자 블레이드를 사용하여 시험한다는 것은 설치 공간과 비용의 제약이 따른다. KBP-2000M (2MW) 모의시험장치는 풍력발전기와 같은 대형장비를 연구 개발하는데 필수적이며, 실증을 통해 획득한 Data를 적용함으로서 재품의 문제점을 찾아내고 성능향상을 도모하는데 필요하다. 실증 Data를 시각적으로 3D로 표현함으로서 현장의 풍속/풍향 변화를 사실감 있게 느끼게 되었다. 앞으로도 풍력발전기를 연구개발하거나 성능향상을 위해서는 적절한 제어와 안전을 위한 연동장치를 갖춘 스케일 다운된 모의시험장치 구축이 요구될 것이다. 풍력발전기의 실증과정에서 획득한 데이터를 모의시험장치에 적용(Feedback)하여 지속적인 성능향상을 높여나갈 것이다.

  • PDF

Development of Signal Processing Modules for Double-sided Silicon Strip Detector of Gamma Vertex Imaging for Proton Beam Dose Verification (양성자 빔 선량 분포 검증을 위한 감마 꼭지점 영상 장치의 양면 실리콘 스트립 검출기 신호처리 모듈 개발)

  • Lee, Han Rim;Park, Jong Hoon;Kim, Jae Hyeon;Jung, Won Gyun;Kim, Chan Hyeong
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.2
    • /
    • pp.81-88
    • /
    • 2014
  • Recently, a new imaging method, gamma vertex imaging (GVI), was proposed for the verification of in-vivo proton dose distribution. In GVI, the vertices of prompt gammas generated by proton induced nuclear interaction were determined by tracking the Compton-recoiled electrons. The GVI system is composed of a beryllium electron converter for converting gamma to electron, two double-sided silicon strip detectors (DSSDs) for the electron tracking, and a scintillation detector for the energy determination of the electron. In the present study, the modules of a charge sensitive preamplifier (CSP) and a shaping amplifier for the analog signal processing of DSSD were developed and the performances were evaluated by comparing the energy resolutions with those of the commercial products. Based on the results, it was confirmed that the energy resolution of the developed CSP module was a little lower than that of the CR-113 (Cremat, Inc., MA), and the resolution of the shaping amplifier was similar to that of the CR-200 (Cremat, Inc., MA). The value of $V_{rms}$ representing the magnitude of noise of the developed system was estimated as 6.48 keV and it was confirmed that the trajectory of the electron can be measured by the developed system considering the minimum energy deposition ( > ~51 keV) of Compton-recoiled electron in 145-${\mu}m$-thick DSSD.

DC Link Voltage Control based on Battery SOC of Hybrid Energy Storage System (하이브리드 에너지 저장장치의 배터리 SOC를 고려한 DC Link 전압 제어)

  • Chung, Gyo-Bum
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.74-75
    • /
    • 2013
  • 본 연구는 Back-to-back 구조의 삼상인버터와 양방향 DC/DC 컨버터로 구성된 전력변환기를 이용하여 신재생에너지 발생원을 효과적으로 계통에 연계하여 스마트 그리드의 강인성을 제고하기 위한 슈퍼캐패시터와 배터리로 구성된 하이브리드 에너지 저장장치의 SOC를 고려한 DC Link 전압 제어를 수행하여 스마트그리드의 최적운영 개념을 제안하고, 타당성 검증을 위해 소프트웨어 시뮬레이션 모델을 개발하여 특성을 연구하였다.

  • PDF

Review of Dual Active Bridge Converter Applied to PV-ESS Hybrid System (태양광-ESS 하이브리드 시스템에 적용되는 DAB 컨버터 리뷰)

  • Lee, HanWoo;Lee, KyungSoo
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.385-386
    • /
    • 2020
  • 최근, 에너지저장장치를 활용하여 태양광-ESS 하이브리드 시스템이 도입되고 있다. 태양광-ESS 하이브리드 시스템은 구성방식에 따라 다양한 전력변환장치를 활용한다. 그중 DAB 컨버터는 절연형이며, 양방향 전력전달이 가능하므로 스위칭 기법, 토폴로지 개발 등 연구가 활발히 진행되고 있다. 본 논문에서는 태양광-ESS 하이브리드 시스템에 적용되는 대표적인 벅-부스트 컨버터와 DAB 컨버터에 대해 리뷰한다.

  • PDF

Effective Transmission Method using Energy Efficient Adaptive Modulation (에너지 효율과 적응변조를 이용한 이동통신 시스템의 효율적인 데이터 전송방법)

  • Oh, Eyu-Kyo
    • Journal of Digital Convergence
    • /
    • v.10 no.9
    • /
    • pp.369-374
    • /
    • 2012
  • In this paper, the effective transmission method is proposed to save the energy and to increase the throughput of the communication system using adaptive modulation. Traditionally, adaptive modulation has been used to improve the throughput using the power margin of the system design. Considering the instantaneous energy during the modulation method changing duration, the effective transmission method is proposed. By the simulation, the performance and effectiveness is validated.

Electric power facility status and analysis of operation results for Korea Superconducting Tokamak Advanced Research (KSTAR 대전력 설비 현황 및 운전결과 분석)

  • Kong, Jong-Dae;Hong, Seong-Lok;Hwang, In-Seong;Kim, Yaung-Soo;Eom, Dae-Young
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.85_86
    • /
    • 2009
  • 핵융합반응은 초고온의 플라즈마 상태에서 가벼운 원자핵들이 융합하여 무거운 원자핵으로 바뀌는 현상으로, 이 과정에서 감소된 질량이 막대한 에너지로 변환되는데 이를 핵융합에너지라고 한다. 핵융합에너지는 인류의 에너지 위기를 극복할 수 있는 최적의 대체에너지이며, 무한, 청정, 고효율에너지이다. 이에 국가핵융합연구소(NFRI)는 Green Energy 의 개발과 핵융합에너지 상용화 기술을 개발하기 위해 핵융합연구장치인 KSTAR(Korea Superconducting Tokamak Adavanced Research)를 제작하여 장치의 운전연구 및 기술 확보에 힘을 쏟고 있다. 또한 핵융합 관련 파생기술을 활용한 첨단 신사업 창출에 기여하고 있다. 본 논문에서는 KSTAR 1st Plasma 실험 시 KSTAR 장치에 전력을 공급하기 위한 전력설비 현황, 전력품질분석, 전력사용량 분석을 통해 향후 KSTAR 장치 운전을 위해 필요한 수전설비 증설, 무효전력보상장치 증설 등과 같은 전력계통의 효율화와 안정화를 위한 개선사항에 대해 기술하였다.

  • PDF

A Consideration on the Superconductivity Energy Storage Technology (초전도 에너지 저장 기술에 대한 고찰)

  • Ko, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.6
    • /
    • pp.691-698
    • /
    • 2015
  • Recently, the power industry has a great interest in the superconducting energy storage device as a way to maximize energy efficiency to cope with global warming. A superconducting energy storage device can archive maximization of electric energy use efficiency by storing in the form of a magnetic field energy or a kinetic energy without loss a large amount of electrical energy at the non-peak load and then converting it again into electric energy at the peak load. Therefore, in this study, such as the concept of the superconducting energy storage technologies, the present state of its research and development and its applications are surveyed and analyzed to establish methodology applying the superconducting energy storage technologies to power system.

Development of a 10kw stand-alone power processing unit for SOFC (고체산화물형 연료전지를 위한 10㎾급 독립전력변환장치의 개발)

  • 이진희;조진상;장민수;최세완;한수빈
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.6
    • /
    • pp.551-560
    • /
    • 2003
  • This paper summarizes development of a 10KW stand-alone power processing unit for 5KW SOFC-low voltage battery hybrid fuel cell power generation system. The power processing unit Includes three parts a high frequency DC-DC converter boosts low fuel cell voltage, a DC-AC inverter converts a dc voltage into a regulated ac voltage and a bidirectional DC-DC converter charges or discharges the battery. The converter topology, design, control method, and experimental result arc presented to meet the specifications such as efficiency of 90% and cost of $40/KW laid down for the "2003 Future Energy Challenge Competition" organized by the U.S. Department of Energy and IEEE. and IEEE.

A Basic Experimental Study on Vibration Power Generator for A Green Traffic Network (녹색교통망을 위한 진동력 발전 기초 실험연구)

  • Jo, Byung-Wan;Lee, Yun-Sung;Kim, Young-Ji;Park, Jung-Hoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.6D
    • /
    • pp.675-683
    • /
    • 2009
  • A Basic experimental study for the development of vibration-power generation system from the vibration energy of urban infrastructure, such as a railroad, highway, and bridges, was carried out to harvest electricity from moving vehicles. Starting with the proposal of vibration power generator which converts vibration energy to an electric power by using self-induction technology, the research explains the basic concept of self-induction technology and the dynamic characteristics of a ibration power generator. Also, in order to analyze the correlation of an electromotive force from vibration power generator which depends on external force and vibration speeds, many indoor experiments with various variables were achieved. Based on the experimental results, a vibration power generator system's ability were analyzed. With those results, basic data of vibration power generator system to acquire the maximum available power was confirmed.