• Title/Summary/Keyword: 에너지방출율

Search Result 109, Processing Time 0.024 seconds

Optimal Control of steady Incompressible Navier-Stokes Flows (Navier-Stokes 유체의 최적 제어)

  • Bark, Jai-Hyeong;Hong, Soon-Jo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.15 no.4
    • /
    • pp.661-674
    • /
    • 2002
  • The objective of this study is to develop efficient numerical method to enable solution of optimal control problems of Navier-Stokes flows and to apply these technique to the problem of viscous drag minimization on a bluff body by controlling boundary velocities on the surface of the body. In addition to the industrial importance of the drag reduction problem, it serves as a model for other more complex flow optimization settings, and allows us to study, modify, and improve the behavior of the optimal control methods proposed here. The control is affected by the suction or injection of fluid on portions of the boundary, and the objective function represents the rate at which energy is dissipated in the fluid. This study shows how reduced Hessian successive quadratic programming method, which avoid converging the flow equations at each iteration, can be tailored to these problems.

Analysis on the Electrode Kinetic Parameters at the Pd/LiOH Electrolyte Interface using the Phase-shift Method (위상이동 방법에 의한 Pd/LiOH 전해질 계면의 전극속도론적 패러미터 해설)

  • Chun Jang Ho;Mun Kyeong Hyeon;Cho Sung Chil;Son Kwang Chul
    • Journal of the Korean Electrochemical Society
    • /
    • v.2 no.2
    • /
    • pp.70-74
    • /
    • 1999
  • The electrode kinetic parameters at the Pd/0.5 M LiOH electrolyte interface have been qualitatively studied using the phase-shift method. The phase shift $(\phi)$ depends on both the cathode potential (E>0) and frequency (f), and $\theta$ is inversely proportional to the fractional surface coverage $\theta$. At an intermediate frequency (10 Hz), the phase-shift profile $(\phi\;vs.\;E)$ can be related to the fractional surface coverage $(\theta\;vs.\;E)$. The phase-shift method can be used to estimate or plot the Frumkin adsorption isotherm. The rate (r) of change of the free energy of adsorption with $({\theta})$ is 22.3 kJ/mol. The equilibrium constant (K) for adsorption and the standard free energy $({\Delta}G_{\theta})$ of the adsorbed hydrogen atom $(H_{ads})$ are $3.7\times10^{-3}{\Delta}G_{\theta}>-8.4kJ/mol$, respectively. For 1$0.38>\theta>0$, the energy liberation or the exothermic reaction for hydrogen adsorption at the Pd cathode can be occurred. The electrode kinetic parameters $(r,\;K,\;{\Delta}G_{\theta}$ depend on the fractional surface coverage $({\theta})$ or the phase shift $(\phi)$.

Calculation of the Air-Scattering Dose Rate by the Single Scattering Approximation (단일산란근사법(單一散亂近似法)에 의한 공기중(空氣中) 산란방사선량(散亂放射線量)의 계산(計算))

  • Yook, Chong-Chul;Ha, Chung-Woo;Lee, Jai-Ki;Moon, Philip S.
    • Journal of Radiation Protection and Research
    • /
    • v.4 no.1
    • /
    • pp.21-28
    • /
    • 1979
  • A calculation is presented of air-scattered gamma rays using the modified single-scattering approximation. The air-scattered tissue dose rates are calculated for a general purpose taking into account (a) the buildup and exponential attenuation, (b) the energy spectrum at the position of question and (c) the geometrical scattering volume in three dimensions. These calculations have been further modified to render them applicable to a typical field irradiation facility which is surrounded by a shield wall and in which the source is fitted with a beam collimating device. The results of the calculation include the energy spectra, angular distribution and tissue does rates at source-receiver separation distances of from 35m to 300m. The comparison shows that the present method developed may be generally adequate for the gamma-ray air-scattering problems in field irradiation facilities if energy and angular distribution at the shield are unimportant.

  • PDF

투명전극용 박막의 제작과 전기적인 특성에 대한 연구

  • O, Teresa
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.10a
    • /
    • pp.42.1-42.1
    • /
    • 2011
  • 박막형 디스플레이구서에 있어서 투명전극은 필수적이다. 투명전극은 정보를 표시하기 위해 빛을 외부로 방출시키거나 태양광 등을 소자 내부로 입사시켜야 한다. 또한 전극을 형성하는 박막은 높은 광투과율과 ${\sim}10-4{\Omega}cm$ 정도의 낮은 전기비저항을 가져야 한다. 가장 널리 사용되는 투명전극으로 ITO (Indium Tin Oxide)는 인듐의 독성, 저온증착의 어려움, 스퍼터링시 음이온 충격에 의한 막 손상으로 저항의 증가 및 액정디스플레이의 투명전극으로 사용될 경우 $400^{\circ}C$정도의 높은 온도와 수소플라즈마 분위기에서 장시간 노출시 열화로 인한 광학적 특성변화가 문제로 지적된다. 이러한 문제 해결의 대안으로 ZnO 산화물 반도체가 있는데 ITO 박막에 비해 비저항이 높기 때문에 도핑을 이용한 비저항을 ${\sim}10-4{\Omega}cm$ 정도로 낮추어야 한다. 투명전도막으로는 ITO, FTO 등과 더블어 체적 저항율은 다소 높으나 환원성 분위기에 대한 내성, 가시광 영역에서의 높은 광투과율과 저렴한 가격 등의 장점 등으로 AZO 박막이 주목 받고 있다. ZnO는 ITO 나 FTO에 비해서 700 kJ/mol의 큰 분해에너지를 가지므로 코팅 때 발생하는 전도도 및 투과율이 나빠지는 현상이 발생하지 않는 특징이 있으며, 위의 두 재료에 비해 밴드갭도 가장 낮아서 자외선 투과율이 낮다. 그러나 내습성이 약하기 때문에 이를 보완하기 위하여 내습성향상과 전도성 향상을 위해서 3족 원소인 B, In, Al, Ga 등을 도핑한 ZnO 투명전도막의 연구가 진행되고 있다. 이러한 원소들 중에서 Al로 도핑했을 때 가장 낮은 비저항을 얻을 수 있다고 알려져 있다. 본 연구에서는 SiOC 박막위에 AZO 박막을 제조하기 위하여 RF 마그네트론 스퍼터링법을 이용하여 박막을 성장시켰으며, 박막의 전기적 및 광학적 특성을 조사하였다. AZO 박막은 rf power가 5~200 W인 RF 마그네트론 스퍼터 방법에 의해서 제작되었다. SiOC 박막은 산소와 DMDMOS 전구체의 유량비를 다르게 하여 플라즈마 발생 화학적 기상 증착방법으로 증착되었다. 증착된 SiOC박막은 UV visible spectroscopy에 의해서 분석하였다. 투명전극의 비저항은 rf 전력이 작을 수록 낮았으며, SiOC 절연막 위에 AZO를 증착시킨 후 반사률은 반대로 바뀌는 것을 확인하였다.

  • PDF

Aluminum, Copper and Lead as Shielding Materials in 6 MeV Electron Therapy (6 MeV 전자선 치료 시 차폐물질로서 알루미늄, 구리, 납)

  • Lee, Seung-Hoon;Cha, Seok-Yong;Lee, Sun-Young
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.2
    • /
    • pp.457-466
    • /
    • 2014
  • During irradiation of lesions in cancer treatment with high energy electrons, normal tissue and critical organs are protected by the shielding material. Scattered radiation that generated the shielding materials affect the depth dose and atomic number. Therefore, we want to examine secondary particles and the scattered photons through calculation and its associated analysis, and compare the measurement for the aluminum, copper, and lead shielding substance of which thickness has 95% charge reduction. Dose change rate which effected scattering radiation was found to be +0.88% for material thickness, +0.43% for atomic number, and +19.70%, +15.20%, +12.40% for measurement, +25.00%, +15.10%, +13.70% for calculation on the aluminum, copper, and lead materials of which thickness has 95% charge reduction, respectively, As a result, we found that scattering rate was dependent on thickness than atomic number. In the dose increasing rate, scattered electrons are more important than scattered photon. For the above mentioned reasons, I think that high atomic number materials should be applied to reduce scattered radiation that generated with thickness effect.

The reliability of the cephalogram generated from cone-beam CT (Cone-beam CT로부터 제작된 측모 두부계측방사선사진의 정확도 평가)

  • Kang, Ji-Young;Kim, Kwang-Won;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.37 no.6
    • /
    • pp.391-399
    • /
    • 2007
  • Three-dimensional approaches for the diagnosis and analysis of the dentofacial area are becoming more popular in accordance with the development of cone-beam CT (CBCT). The purposes of this study were to evaluate the reliability of cephalometric measurements of lateral cephalograms generated from a CBCT image by making comparisons with the traditional digital lateral cephalogram, and to evaluate the possibility of the clinical application of CBCT generated cephalogram images. Methods: Twenty patients whose external auditory meatus could be identified in the CBCT image were selected, and both CBCT and digital cephalograms were taken. Differences between the measurements of both cephalograms were tested by paired t-test. Results: Among the 22 measurements used, only U1-FH, Mx6 to PTV, and maxillomandibular difference showed statistically significant differences between the CBCT generated cephalogram and the digital cephalogram. Conclusions: The results suggest that the CBCT generated cephalogram can be used for some cephalometric measurements not requiring porion, PTV, condylion as a landmark (SNA, SNB, U1 to SN, IMPA, interincisal angle, etc.).

A Study on Fire Characteristics of Solid Combustible Materials Based on Real Scale Fire Test (실규모 실험에 의한 고체가연물의 화재특성 연구)

  • Kim, Sung-Chan
    • Fire Science and Engineering
    • /
    • v.25 no.5
    • /
    • pp.62-68
    • /
    • 2011
  • A series of fire tests involving realistic solid combustible materials was conducted to quantify the heat release rate and investigate the fire growth characteristics during the initial fire growth stage. For these tests, single/double wood cribs, urethane cushion having polypropylene covers and wood crib on nylon carpet with urethane carpet padding were used as a fuel source. The fire growth coefficient of the solid combustible materials was quantified and the fire growth characteristics were compared with the $t^2$ fire scenario. The mean effective heat of combustion was evaluated by the total mass loss of fuel and total energy release concept and examined the effect of the ventilation and fire condition. The present study provides the practical information on the fire growth characteristics of solid combustible material to design to a set of fire scenarios for the fire risk analysis.

Inclined Edge Crack in a Piezoelectric Material Under Antiplane Loads (압전재료에 대한 면외하중하의 모서리 경사 균열)

  • Choi, Sung Ryul;Sah, Jong Youb;Jeong, Jae Tack
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.6
    • /
    • pp.589-596
    • /
    • 2015
  • The occurrence of an inclined edge crack in transversely piezoelectric material is analyzed. Concentrated antiplane mechanical and inplane electrical loads are applied at the boundary and crack surface, respectively. The crack surfaces are assumed to be impermeable to the electric field. Using the Mellin transform with the introduction of a generalized displacement vector, the problem is formulated, and the Wiener-Hopf equation is derived. By solving the equation, the solution is obtained in a closed form. The intensity factors of the stress, the electric displacement, and the energy release rate are obtained for any crack length and inclination angle. These solutions can be used as fundamental solutions and can be superimposed to represent any arbitrary electromechanical loading.

Wear Characteristic of Diamond Burs in Dentistry (치과용 다이아몬드 버의 마멸 특성)

  • 이근상;임영호;권동호;최만용;김교한;최영윤
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.80-84
    • /
    • 1996
  • This paper aims at reviewing the Possibility application over normal or abnormal, detection used by AE and the wear characteristics of grinding process. In this study, when diamond bur in dentistry with chosen grinding conditions were tuned at grinding. The variation of grinding resistance and hE signal is detected by the use of AE measuring system. The tests are carried out in accordance with diamond burs and workpiece; arcyl and bovine. According to the experiment results, the following can be expected; AE has the possibility to detect the state normality and abnormality. However, the grinding resistance measuring can find it difficult to detect it. It can be accurately excerpted from AE occurrence pattern in contact start point of diamond bur and bovine, grinding condition and derailment point. It is known that AE$\_$rms/ is well compatible with grinding resistance. According to the increase of the material removal rate, the specific energy of the diamond bur is inclined to decrease and the grinding resistance has a tendency to increase.

  • PDF

A study of mixed-mode interlaminar fracture toughness of graphite/epoxy composite (炭素纖維强化 複合材料의 혼합모우드 層間破壞靭性値에 대한 硏究)

  • 윤성호;홍창선
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.2
    • /
    • pp.198-207
    • /
    • 1986
  • This study investigates interlaminar fracture characteristics of Graphite/Epoxy composite (HFG Graphite/Epoxy) under mode I (opening mode), mode II (sliding mode) and mixed mode loading conditions. The effects on interlaminar fracture toughness due to different fiber orientations on the crack surface are also investigated. The antisymmetric test fixture proposed by M. Arcan is used for this test. Both critical stress intensity foctors and critical energy release rates were determined and several mixed mode fracture criteria were compared to the experimental data. Also fracture surfaces were investigaed to obtain informations on the fracture behaviors of Graphite/Epoxy composite by means of a scanning electron microscope(SEM).