• Title/Summary/Keyword: 업무용건축물

Search Result 47, Processing Time 0.024 seconds

Proposal for Evacuee Guidance of Cloud-based Elevator System in Emergency Situation (클라우드 기반 비상탈출 시 피난유도 승강기시스템 제안)

  • Choi, Jun-Ho;Shin, Seung-Jung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.1
    • /
    • pp.25-28
    • /
    • 2015
  • Lifts are used as an essential means of transportation within the building in an emergency situation, when used as a means of escape, so expect a lot of research has been conducted high effect. Number of stories in the Seoul-rise building guidelines underground 7th floor, 53 ground floor, floor area $6,800m^2$, floor area $127,050m^2$, use is cultural and convention facilities and sales facilities, business facilities and accommodation (hotel), the construction of public housing (apartments) hagieneun not efficient to install elevators for evacuation mothada was determined separately in designing the lift is designed according to the standards of passenger lifts installed under a judgment as to use for evacuation. However, this does not include detailed design guidelines so far.[1] We propose the Evacuee Guidance of Elevator System that can be used as entering air equipment, sprinkler and smart phone evacuation system.

A Study on Establishing Urban Spatial Structure through Central Hierarchy Analysis: Focus on Daejeon (중심지 위계 분석을 통한 대전시 도시공간구조 설정에 관한 연구)

  • RYU, KYUNG-SOO;PARK, SOUNG-EUN
    • Journal of the Korean Regional Science Association
    • /
    • v.40 no.2
    • /
    • pp.57-73
    • /
    • 2024
  • The purpose of this study is to establish the central hierarchy and urban spatial structure of Daejeon in 2040 using differentiated analysis indicators. In order to establish a central hierarchy in the future urban space of Daejeon City, three indicators were derived: population density, use of buildings (commercial, office, residential, etc.) and traffic volume data(KTDB). The results of analyzing the center hierarchy using indicators are as follows. First, the primary centers responsible for urban (core) functions are set in three areas, including Dunsan downtown, the original downtown (Daejeon Station area, designated as a special urban convergence zone), and Doan New Town, and the secondary centers corresponding to sub-city centers (regional bases). was set at 9, 10 tertiary centers corresponding to regional centers (living area centers), and a center hierarchy was established with 5 new specialized bases. Second, new secondary and tertiary centers emerged that were different from the center hierarchy in the 2030 Daejeon Urban Basic Plan. The three indicators used in this study yielded meaningful results in establishing urban spatial structure and central hierarchy that can secure urban competitiveness.

Research on the Construction of an Automation Model for Maintenance Managers Based on Smart Devices (스마트 디바이스 기반 유지보수 관리자용 자동화 모델 구축에 관한 연구)

  • Park, Jihwan;Chung, Suwan;Lee, Seojoon;Song, Jinwoo;Kwon, Soonwook
    • Korean Journal of Construction Engineering and Management
    • /
    • v.22 no.1
    • /
    • pp.72-80
    • /
    • 2021
  • Based on the previous year's statistics, 37% of buildings in South Korea are aged over 30 years. As the number of the aging buildings increases, so does the need for maintenance. Building maintenance involves a significant number of works; the work of 'maintenance manager' accounting for the largest part. Currently, the maintenance history record is mostly in drawing or handwritten form which makes reviewing the data highly time consuming. Therefore, to improve the convenience of maintenance works and optimize historical data management, the existing maintenance process was analyzed. Problems were derived and a smart device-based automation model was established. In order to establish a smart device-based automation model, ① general flow of facility management process was analyzed and related articles were reviewed, ② current maintenance process was optimized, ③ functional block diagram of BIM Data, COBie Data, IoT, and AR-based automated maintenance management model was created, ④ a smart device-based automated maintenance management model was constructed, ⑤ finally, the above system was verified by testing the aforementioned model in the field site, evaluating the time required for the maintenance process and reviewing maintenance history data against the current one.

The Effect of Eco-friendly Characteristics on the Price of Office Buildings (친환경 특성이 오피스 빌딩 가격에 미치는 영향)

  • So, Soung Kue;Cho, Joo Hyun
    • Korea Real Estate Review
    • /
    • v.28 no.2
    • /
    • pp.49-64
    • /
    • 2018
  • The purpose of this study is to analyze the effect of eco-friendly building certification grade on the price and cost of office in Seoul office building. For this purpose, multiple regression analysis is used to examine the prices of buildings. In order to identify the effect of environmental cost reduction of buildings with high eco-friendly certification, we also performed LCC (Life Cycle Cost) + LCA (Life Cycle Assessment) analysis. Results of our analysis show that office buildings with a higher level of eco-friendly certification are priced significantly higher. Through LCC analysis, it was also found that buildings with high levels of eco-friendly certification cost less than those with lower-level certification. Furthermore, it was confirmed that office buildings with higher-level environmental certification have total lower environmental load costs (TCA = LCC+LCA) than buildings without certification. According to the TCA analysis, buildings with a high level eco-certification generated lower social costs than buildings with lower-level or no certification.

Interior heating effect in an office building according to heat properties of light fixture (업무용 건축물의 실내 조명기구 특성에 따른 발열 효과에 관한 연구)

  • Lee, Yoon-Jin;Ahn, Byung-Lip;Kim, Jong-Hun;Jeong, Hak-Geun;Jang, Cheol-Yong;Kim, Tae-Yeon
    • KIEAE Journal
    • /
    • v.15 no.2
    • /
    • pp.117-122
    • /
    • 2015
  • Purpose: Generally, 30% of the total energy consumption in office building is used for artificial indoor lightings, and almost 75-85% of electric power in fluorescent and Light-Emitting Diode (LED) lightings can be dissipated as a form of heat into indoor environment. The heat generated by indoor lightings can cause the increase of cooling load in office buildings. Thus, it its important to consider indoor lightings as a heat and light source, simultaneously. Method: In this study, we installed two kinds of indoor lightings including fluorescent and LED lightings and measured surface temperature of both indoor lightings. In addition, we obtained ambient temperature of indoor space and finally calculated total heat dissipated from plenum area and surface of lightings. Result: Total indoor heat gain was 87.17Wh and 201.36Wh in cases of six 40W-LED lightings and 64W-fluorescent lightings, respectively.

A Study on the Reference Building based on the Building Design Trends for Non-residential Buildings (건축물 설계현황 분석을 통한 국내 비주거용 표준건물의 설정에 관한 연구)

  • Jeong, Young-Sun;Jung, Hae-Kwon;Jang, Hee-Kyung;Yu, Ki-Hyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.1-11
    • /
    • 2014
  • The Korean government plans to introduce the building energy performance standard which regulates the annual energy consumption of buildings. This paper aimed to set up the reference building from database based on the building design trends for non-residential buildings. We surveyed the design data of 435 non-residential buildings which were granted building permission from 2007 to 2011. And we conducted estimation on the heating & cooling load and the energy consumption of the reference building using ECO2 program. From results, the reference building of non-residential buildings was office building which had a total 7 floors and $20,838m^2$ gross floor area. And it suggests the design reference data of building envelope, HAVC, heat source equipment and lighting system for the reference building. The total annual energy use of the reference building was $151.9kWh/m^2yr$.

A Study on the Evacuation Performance Review for the Office Buildings (업무용 빌딩의 피난 성능 검토에 관한 연구)

  • 오혁진;백승태;김우석;이수경
    • Fire Science and Engineering
    • /
    • v.17 no.3
    • /
    • pp.1-6
    • /
    • 2003
  • In this study, it reviewed about evacuation performance of a specified Office Building. assessment tools is FAST 3.1.7 (Estimation of Flash Over, Estimation of Layer Height Down Flow Time), SIMULEX 32-bit (Estimation of Evacuation Time), JASMINE 3.25d. (Smoke Flow Assessment of a specified time) Result from Fire Scenario # 1, Flash Over is not generated in Compartment. Evacuation Time is estimated 25.2 sec by SIMULEX 32-bit. layer height until this time (25.2 sec) was estimated 2.4 m by FAST 3.1.7. After ignition until this time (25.2 sec), smoke was not release to the a corridor. In consequence, We concluded that people in building are completing the safe evacuation without the damage of smoke. Result from Fire Scenario # 1, Flash Over generated 6 min 33.2 sec in Compartment. Evacuation Time is estimated 1 min 25.5 sec by SIMULEX 32-bit. layer height down flow time is 1 min 40.8 sec by FAST 3.1.7 and 5 min 23 sec by theoretical calculation. Also, total building evacuation time was estimated 2 min 26.6 sec. After ignition until this time (2 min 26.6 sec), smoke released to the a corridor but it amount was few little. Therefore, generated smoke in compartment not effected to the people in buildings.

A Study on the Non-residential Building Envelope Remodeling for Energy Efficiency (비주거용 건물의 외피 리모델링을 통한 에너지성능향상 방안에 관한 연구)

  • Jang, Hyun-Sook;Lee, Sang-Ho
    • Korean Journal of Construction Engineering and Management
    • /
    • v.13 no.6
    • /
    • pp.3-12
    • /
    • 2012
  • The slowdown of private building industry resulted in growth of remodeling market as a way to improve energy performance. Remodeling is considered more cost-effective and eco-friendly approach for energy efficient building than new construction. Since 2008, Seoul has promoted Building Retrofit Project (BRP) preponderantly to attract energy-saving renovation by supporting building owners to switch building system into energy-saving system when they remodel their old buildings. According to 2012 press release, 254 Private sectors participated in this green building project and annually reduced 41000ton of greenhouse gas emission, 14000TOE, which also result in 7.5 billion won energy cost savings per year. The paper focuses on the building envelope remodeling as a way to improve energy efficiency. Different components of the building envelope such as wall insulation, window, and shading, were applied to the baseline model and the comparison was analyzed to come up with the ideal solution. This study only assesses the building envelope as to suggest the way to redesign the better energy performing building. Offering solution focusing on the architectural feature is essential because it will provide basic information and standard when remodeling a building for energy efficiency, especially, for the nonresidential buildings used as rental offices.

Development of Energy Optimized Geometry Using BIM for Super Tall Office Building in Early Design Stages (BIM을 이용한 건축물 초기 디자인 단계에서 초고층 업무용 건물의 최적 에너지 형태개발)

  • Ryu, Han-Soo;Kim, In-Han;Choo, Seung-Yeon
    • Korean Journal of Computational Design and Engineering
    • /
    • v.16 no.2
    • /
    • pp.83-91
    • /
    • 2011
  • There are many researches to make low-energy building. Lots of them focus on facility systems and insulation performance of building materials. However, not only systematic solutions but also approaches in early design stages are important to reduce energy consumption. Using BIM(Building Information Modelling) is considered as an effective and efficient way to simulate building energy and decide alternatives than traditional energy simulation because BIM based energy simulation makes to reduce much time for energy modeling. This study focuses on development of optimized geometry for super tall office buildings in Seoul, Korea. Specifically, length to width ratio and building orientation are main topics of this study because these two topics are the most basic and preceding factors deciding mass design. In this study, Revit MEP 2011 and Ecotect Analysis 2011 are used to make case models and calculate energy load in early design stages. Energy properties of material abide by Korean Standards for Energy Conservation in Building, Korean Guideline for Energy Conservation in Public Office and ASHRAE Standard in USA. This study presents best length to width ratio of plan and optimized orientation by evaluating the case models. Furthermore, this study suggests what should be considered for each case to decrease energy load.

Recommended Practice for a Reasonable Power Density end Analysis of Power Consumption Capacity for the year in Large-scale Buildings (대형 건물의 연간 전기에너지 사용총량 및 전력원단위 분석에 관한 연구)

  • Kim, Se-Doug;Yoo, Sang-Bong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.6
    • /
    • pp.85-88
    • /
    • 2009
  • This paper shows a reasonable power density, that was made by the systematic and statistical way considering actual conditions, such as investigated power consumption capacity for the year and peak power, contract power for the last 5 years of each customer for 23 general customers all data obtained by AMR. In this dissertation, it is necessary to analyze the key features from the investigated data. It made an analysis of the feature parameters, such as average, standard deviation, median, maximum, minimun and load factor.