• Title/Summary/Keyword: 어태치먼트

Search Result 55, Processing Time 0.026 seconds

Effect of prosthetic designs and alveolar bone conditions on stress distribution in fixed partial dentures with pier abutments (중간 지대치가 존재하는 고정성 국소의치에서 보철물 설계 및 치조골 상태가 응력분포에 미치는 영향)

  • Cho, Wook;Kim, Chang-Seop;Jeon, Young-Chan;Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.328-334
    • /
    • 2009
  • Statement of problem: Pier abutments act as a Class I fulcrum lever system when the teeth are incorporated in a fixed partial denture with rigid connectors. Therefore non-rigid connector incorporated into the fixed partial denture might reduce the stresses created by the leverage. Purpose: The purpose of this study was to evaluate, by means of finite element method, the effects of non-rigid connectors and supporting alveolar bone level on stress distribution for fixed partial dentures with pier abutments. Material and methods: A 2-dimensional finite element model simulating a 5-unit metal ceramic fixed partial denture with a pier abutment with rigid or non-rigid designs, the connector was located at the distal region of the second premolar, was developed. In the model, the lower canine, second premolar, and second molar served as abutments. Four types of alveolar bone condition were employed. One was normal bone condition and others were supporting bone reduced 20% height at one abutment. Two different loading conditions, each 150 N on 1st premolar and 1st molar and 300N on 1st molar, were used. Results: Two types of FPD were displaced apically. The amount of displacement decreased in an almost linear slope away from the loaded point. Non-rigid design tended to cause the higher stresses in supporting bone of premolar and molar abutments and the lower stresses in that of canine than rigid design. Alveolar bone loss increased the stresses in supporting bone of corresponding abutment. Conclusion: Careful evaluation of the retentive capacity of retainers and the periodontal condition of abutments may be required for the prosthetic design of fixed partial denture with a pier abutment.

OVERDENTURES AND OSSEOINTEGRATED IMPANTS (오버덴춰와 골융합성 임프란트)

  • Shin Sang-Wan;Suh Kyu-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.3
    • /
    • pp.197-203
    • /
    • 1991
  • 저작압을 골에 직접 분산시키고 의치를 직접 골에 부착시켜 의치의 안정성을 증진시키는 가능성을 실현하는 것이 오랫동안 보철과의사들의 목표였다. 수십년 동안 골과 티타늄 임프란트가 결합(적합)되는 골융합성 술식이 발전되어 왔으며 이 임프란트의 상부구조물로 고정식 보철물이 받아들여져 왔다. 현재까지 가장 흔한 상부구조는 고정식 보철물이다. 요즈음 골융합성 임프란트에 지지를 받는 오버 덴춰의 술식이 고정식 보철물과 다른 하나의 방법으로 간주되어질 수 있게 되었다. 오버덴춰 술식이 심미적 경제적 이유 그리고 다양하게 적용할 수 있기 때문에 최근에 확대되는 경향이 있다. 골융합성 임프란트에 의한 고정식 보철물에 대한 광범위한 장기 결과들이 있는데 반하여 여러 어태치먼트를 이용한 오버덴춰 술식은 임상결과나 적용에 과한 지식들이 거의 발표되지 않았으며, 현재까지 임프란트 오버덴춰를 가진 환자의 구강기능에 대한 단지 몇개의 연구들만이 발표되었다. 우리는 장기 임상평가에 의해서 임프란트 오버덴춰를 아주 조심스럽게 평가해야 한다.

  • PDF

Maxillar implant-retained overdenture using CAD/CAM milled zirconia bar with PEKK sleeve: a case report (상악 무치악 환자에서 가공 지르코니아 바와 PEKK 슬리브를 이용한 임플란트 피개의치 증례)

  • Ju, Jin-Seok;Cho, Jin-Hyun;Lee, Cheong-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.4
    • /
    • pp.307-313
    • /
    • 2017
  • The object of this case report is to introduce milled zirconia bar and PEKK female part made by CAD/CAM technology for bar attachment implant supported overdenture in maxillary edentulous patients. For over 2 years, in terms of function and esthetics, satisfactory result was obtained. Esthetically and functionally satisfactory results were obtained in periodic follow up check.

Maxillary removable partial overdenture within Locator Root Attachment in a retained root: a case report (소수 잔존 치근에 Locator Root Attachment를 활용한 상악 가철성 국소의치 증례)

  • Shin, Jin-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.3
    • /
    • pp.199-206
    • /
    • 2017
  • If maintaining oral few retained root when planning the removable prosthesis, it is possible to obtain a more comfortable and functional result. In this case report, 'Locator Root Attachment' was used to maxillary removable overdenture in patients with a few teeth and retained root. A functionally proper clinical result from attachment after clinical and radiographic analysis was observed in this case.

Maxillary implant-retained overdenture using CAD/CAM milled titanium bar with Locator® attachment: a case report (CAD/CAM으로 제작된 milled titanium bar와 Locator®를 이용한 상악 임플란트 유지 피개의치: 증례보고)

  • Kim, Min-Jeong;Oh, Sang-Chun;Huh, Yoon-Hyuk
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.1
    • /
    • pp.64-70
    • /
    • 2014
  • The purpose of this case report is to introduce milled titanium bar with Locator$^{(R)}$ that made by CAD/CAM for implant supported overdenture in maxillary edentulous patients. For over 2 years, in terms of function and esthetics, satisfactory result was obtained.

Analysis of a Circular Microstrip Patch Antenna with Dielectric Superstrate using the Rigorous Probe Feed Model (정확한 급전 구조를 고려한 레이돔 원형 패치 안테나 해석)

  • 최동혁;박경빈;박성욱
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.6
    • /
    • pp.859-867
    • /
    • 2000
  • In order to analyze the effect of a cover layer or radome for an antenna, the moment method is applied to the analysis of the circular microstrip patch antenna with dielectric superstrate fed by coaxial probe. The probe feed is modeled as a attachment mode method which can solve more exact analysis. In case of a ideal probe feed modeling, the probe self-impedance as well as the rapidly-varying patch current at the vicinity of the feed point was neglected. But a rigorous probe feed model which overcomes these deficiencies are developed, and used in the analysis of isolated circular patches. Measurements were performed to validate the numerical results. These are good agreement with each other.

  • PDF

A Study on Motion Control and Kinematics Analysis of Articulated Manipulator Attachment for Excavator (포크레인용 다관절 매니퓰레이터 어태치먼트 운동학 해석 및 모션제어)

  • Kim, Hee-Jin;Kim, Sang-Hyun;Jang, Ki-Won;Han, Sung-Hyun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.6
    • /
    • pp.807-819
    • /
    • 2019
  • In this paper, it is proposed a new approach to motion control and kinematics analysis of articulated manipulator attachment with five degree of freedom for excavator. Unlike the well-established theory for the control of linear systems, there is little general control theory relatively for a robust control of nonlinear systems. The control technique is essential for providing a stable and robust performance for application of articulated manipulator control. The proposed control algorithm is one of robust control methods based on error informations of the position and velocity error informations using stability analysis of dynamic model. Through simulation test, the proposed control scheme is illustrated to be a efficient control technique for real-time control.

Photoelastic stress analysis of the mandibular unilateral free-end removable partial dentures according to the design (하악 편측 유리단 가철성 국소의치의 설계에 따른 광탄성 응력 분석)

  • Park, Cheol-Woo;Kay, Kee-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.206-214
    • /
    • 2009
  • Statement of problem: There are common clinical cases in which the mandibular first and second molars are missing unilaterally. Purpose: This study was designed to compare and evaluate the magnitude and distribution of stress produced by four kinds of mandibular unilateral free-end removable partial dentures that could be applied clinically in Kennedy class II cases. Material and methods: Four unilateral free-end removable partial dentures using clasp, Konus crown, resilient attachment, and flexible resin were fabricated on the photoelastic models of the Kennedy class II cases. The vertical load of 6㎏ was applied on the central fossa of the first molar of every removable partial denture in the stress freezing furnace and the photoelastic models were frozen according to the stress freezing cycle. After these models were sliced mesio-distally to a thickness of 6mm, the photoelastic isochromatic white and black lines of the sliced specimens were examined with the transparent photoelastic experiment device and photographs were taken with a digital camera. The fringe order numbers at eight measuring points in the photograph were measured with the naked eye. Results: The maximum fringe order number of each sliced specimen and the fringe order number at the residual ridge just below the loading point were in the decreasing order of the unilateral removable partial dentures using flexible resin followed by clasp, resilient attachment, and Konus crown. The fringe order number at the root apex of the second premolar was in the decreasing order of the unilateral removable partial dentures using clasp followed by flexible resin, Konus crown, and resilient attachment. Conclusion: The removable partial denture using Konus crown showed the most equalized stress distribution to the supporting alveolar bone of abutment teeth and residual ridge under the vertical loads. The removable partial denture using flexible resin can be applied to the case that has a better state of residual ridge than abutment teeth.

Comparison of the retentive characteristics of two additional attachment used with an implant bar attachment (임플란트 bar 어태치먼트에 사용하는 두 가지 부가적인 유지장 치의 유지력 특성 비교)

  • Choi, Jae-Won;Chae, Sung-Ki;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.2
    • /
    • pp.173-180
    • /
    • 2021
  • Purpose: The purpose of this study was to evaluate the retentive characteristics of the additional attachments used with implant bar attachment under repeated insertion/removal cycles. Materials and methods: The newly developed attachment and the commercially available attachment were investigated: ADD-Lock (AL), Locator blue (LB). Two fixtures were placed parallel to each other on the custom lower mounting, and patrix of each attachment was fixed to the fixture. Also, the matrix of each attachment was placed on the opposing upper mounting. A universal testing machine was used to measure the retentive force during initial, 100, 250, 500, 1000, 2000, and 2500 repeated insertion/removal cycles. Wear and deformation of the attachment s were observed by scanning electron microscopy (SEM). Mann-Whitney U test (α=.05) and wilcoxon signed-rank test (α=.05) were performed to compare retentive force between each group and before and after 2500 repeated insertion/removal cycles. Results: In terms of initial retentive force and retentive force after 2500 repeated insertion/removal cycles, the AL group (15.24 ± 1.46 N and 9.74 ± 1.16 N) showed significantly smaller values than the LB group (43.53 ± 12.39 N and 22.99 ± 4.77 N) (P<.05). Also, in the loss of retentive force, the AL group (5.50 ± 1.08 N, 36.08%) showed a smaller value than the LB group (20.54 ± 11.89 N, 47.19%) (P<.05). Based on SEM analysis, The AL group showed noticeable wear and deformation in the patrix and the LB group in the matrix. Conclusion: Locator showed a higher initial retentive force than newly developed attachment, while the loss of retentive force was also higher. Both additional attachments are considered to have sufficient retentive force after repeated insertion/removal cycles.

Full mouth rehabilitation with maxillary implant overdenture using prefabricated bar attachment system: a case report (기성품 바 어태치먼트 시스템인 SFI bar를 이용한 피개의치 전악수복 증례)

  • Shin, Eun-Jung;Joo, Han-Sung;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Lim, Hyun-Pil;Yun, Kwi-Dug
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.4
    • /
    • pp.331-337
    • /
    • 2014
  • In conventional bar- and clip-retained overdentures, all errors during impression making and cast fabrication result in non-passive fit of bars. SFI bar is prefabricated and assembled in the patient's mouth without the use of soldering, laser welding or conventional bonding techniques, thus reducing stress transmission to, bone loss around the implants and leading to fewer errors and lower costs. A clinical case will be presented below to demonstrate the use of the SFI Bar (Stress Free on Implant Bar) to restore an severe atrophy edentulous maxilla. In this case, no lateral stress could be applied to the implants due to the telescopic design of the bar joints. However, periodic recall check is necessary and long-term clinical results are required.