Browse > Article
http://dx.doi.org/10.14368/jdras.2017.33.4.307

Maxillar implant-retained overdenture using CAD/CAM milled zirconia bar with PEKK sleeve: a case report  

Ju, Jin-Seok (Department of Prosthodontics, School of Dentistry, Kyungpook National University)
Cho, Jin-Hyun (Department of Prosthodontics, School of Dentistry, Kyungpook National University)
Lee, Cheong-Hee (Department of Prosthodontics, School of Dentistry, Kyungpook National University)
Publication Information
Journal of Dental Rehabilitation and Applied Science / v.33, no.4, 2017 , pp. 307-313 More about this Journal
Abstract
The object of this case report is to introduce milled zirconia bar and PEKK female part made by CAD/CAM technology for bar attachment implant supported overdenture in maxillary edentulous patients. For over 2 years, in terms of function and esthetics, satisfactory result was obtained. Esthetically and functionally satisfactory results were obtained in periodic follow up check.
Keywords
maxillary edenturous; milled zirconia bar; PEKK sleeve; implant supported overdenture;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Zitzmann NU, Marinello CP. Treatment plan for restoring the edentulous maxilla with implantsupported restorations: removable overdenture versus fixed partial denture design. J Prosthet Dent 1999;82:188-96.   DOI
2 Zembic A, Wismeijer D. Patient-reported outcomes of maxillary implant-supported overdentures compared with conventional dentures. Clin Oral Implants Res 2014;25:441-50.
3 Sanna A, Nuytens P, Naert I, Quirynen M. Successful outcome of splinted implants supporting a 'planned' maxillary overdenture: a retrospective evaluation and comparison with fixed full dental restoration. Clin Oral Implants Res 2009;20:406-13.   DOI
4 Sadowsky SJ, Zitzmann NU. Protocols for the maxillary implant overdenture: a systematic review. Int J Oral Maxillofac Implants 2016;31 Suppl:s182-91.
5 Kim HY, Lee JY, Shin SW, Bryant SR. Attachment systems for mandibular implant overdentures: a systematic review. J Adv Prosthodont 2012;4:197-203.   DOI
6 Stoumpis C, Kohal RJ. To splint or not to splint oral implants in the implant-supported overdenture therapy? A systematic literature review. J Oral Rehabil 2011;38:857-69.   DOI
7 Murray MD, Darvell BW. The evolution of the complete denture base. Theories of complete denture retention - a review. Part 1. Aust Dent J 1993;38:216-9.   DOI
8 Petropoulos VC, Smith W, Kousvelari E. Comparison of retention and release periods for implant overdenture attachments. Int J Oral Maxillofac Implants 1997;12:176-85.
9 Sadowsky SJ. Treatment considerations for maxillary implant overdentures: a systematic review. J Prosthet Dent 2007;97:340-8.   DOI
10 van Kampen F, Cune M ,van der Bilt A, Bosman F. Retention and postinsertion maintenance of barclip, ball and magnet attachments in mandibular implant overdenture treatment: an in vivo comparison after 3 months of function. Clin Oral Implants Res 2003;14:720-6.   DOI
11 Mericske-Stern RD, Taylor TD, Belser U. Management of the edentulous patient. Clin Oral Implants Res 2000;11:108-25.   DOI
12 Katsoulis J, Mericske-Stern R, Yates DM, Izutani N, Enkling N, Blatz MB. In vitro precision of fit of computer-aided design and computer-aided manufacturing titanium and zirconium dioxide bars. Dent Mater 2013;29:945-53.   DOI
13 Najeeb S, Zafar MS, Khurshid Z, Siddiqui F. Applications of polyetheretherketone (PEEK) in oral implantology and prosthodontics. J Prosthodont Res 2016;60:12-9.   DOI
14 Park C, Jun DJ, Park SW, Lim HP. Use of polyaryletherketone (PAEK) based polymer for implantsupported telescopic overdenture: a case report. J Adv Prosthodont 2017;9:74-6.   DOI
15 Passia N, Ghazal M, Kern M. Long-term retention behaviour of resin matrix attachment systems for overdentures. J Mech Behav Biomed Mater 2016;57:88-94.   DOI