• Title/Summary/Keyword: 어레이센서

Search Result 234, Processing Time 0.025 seconds

A Design of Signal Transport System with High Reliability in an Underwater Sensor Array (수중 센서 어레이에서 고 신뢰성을 고려한 신호 전송 시스템 설계)

  • Son Dong-Hwan;Chung Hyun-Ju
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.7 no.4 s.19
    • /
    • pp.13-19
    • /
    • 2004
  • A system for detecting underwater target demands a high operational reliability because of the difficulty of maintenance and repair when the system has a few troubles during long operating period. Therefore, in this paper, we have proposed a signal transport system with a high reliability in an underwater sensor array system composed of magnetic and acoustic sensors. In this system, the nodes for signal transport are connected dually each other with single-hop construction and a magnetic sensor is connected to a couple of neighboring nodes. This enables the output signal to transport from a node to the next node and the next but one node. Also, the signal from a magnetic sensor can be transported to two nodes at the same time. Thus, the system with this construction makes possible to transport sensor data to another node which works normally when a transport node or cable have some faults and will operate normally although it happens some problems in a few signal transport nodes and connection cables.

Design and Implementation of the Diseases Diagnosis System Using The Cantilever Micro-Arrays (박막 캔틸레버 어레이 센서를 이용한 질병 진단기 설계 및 구현)

  • Jung, Seung-Pyo;Choi, Jun-Kyu;Lee, Jung-Hoon;Park, Ju-Sung
    • Journal of IKEEE
    • /
    • v.19 no.1
    • /
    • pp.52-57
    • /
    • 2015
  • The disease diagnosis system has been developed using the thin nitride(Si3N4) cantilever arrays which can measure the difference of capacitances between sensor and reference. The system consists of 32-bits RISC(Reduced Instruction Set Computer), RAM/Flash, bus, communication IP's, ADC(Analog Digital Converter) board, and LCD display. The marker selection method, which give us the good accuracy from reasonal numbers of markers, is suggested. The developed system has the resolution under 1fF and can detect 10nM concentration of Thrombin.

Design and fabrication of wafer scale microlens array for image sensor using UV-imprinting (UV 임프린팅을 이용한 이미지 센서용 웨이퍼 스케일 마이크로렌즈 어레이 설계 및 제작)

  • Kim, Ho-Kwan;Kim, Seok-Min;Lim, Ji-Seok;Kang, Shin-Ill
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2007.10a
    • /
    • pp.100-103
    • /
    • 2007
  • A microlens array has been required to improve light conversion efficiency in image sensors. A microlens array can be usually fabricated by photoresist reflow, hot-embossing, micro injection molding, and UV-imprinting. Among these processes, a UV-imprinting, which is operated at room temperature with relatively low applied pressure, can be a desirable process to integrate microlens array on image sensors, because this process provides the components with low thermal expansion, enhanced stability, and low birefringence, furthermore, it is more suitable for mass production of high quality microlens array. In this study, to analyze the optical properties of the wafer scale microlens array integrated image sensor, another wafer scale simulated image sensor chip array was designed and fabricated. An aspherical square microlens was designed and integrated on a simulated image sensor chip array using a UV-imprinting process. Finally, the optical performances were measured and analyzed.

  • PDF

Adaptive Microphone Array System with Self-Delay Estimator (지연 추정 기능을 갖는 적응 마이크로폰 어레이 알고리즘)

  • Jung Yang-Won;Kang Hong-Goo;Lee Chungyong;Youn Dae Hee
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.1C
    • /
    • pp.54-60
    • /
    • 2005
  • In this Paper, an adaptive microphone array system with self-delay estimator is proposed. By showing that the adaptive blocking matrix (ABM) of the generalized sidelobe canceller (GSC) can estimate the relative time delay between each sensor, the proposed system utilizes the ABM not only for blocking target components in the blocked signal path, but also for estimating the relative time delay. Therefore, the proposed system requires only the GSC structure while maintaining the system performance similar to the conventional system using an additional time delay estimator as a preprocessor. Simulation results show that the performance of the proposed system is identical to the conventional system that uses an additional time delay estimation module.

A Dual Micro Gas Sensor Array with Nano Sized $SnO_2$ Thin Film (나노 박막을 이용한 듀얼 $SnO_2$ 마이크로 가스센서 어레이)

  • Chung Wan-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.9
    • /
    • pp.1641-1647
    • /
    • 2006
  • A dual micro gas sensor way for detecting reducing gas and bad order was fabricated using nano sized $SnO_2$ thin film fabrication method. To make nano-sized thin gas sensitive $SnO_2$ thin rilm, thin tin metal layer $2500{\AA}$ thick was oxidized between 600 and $800^{\circ}C$ by thermal oxidation. The gas sensing layers such as $SnO_2,\;SnO_2(+Pt)\;and\;SnO_2(+CuO)$ were patterned by metal shadow mask for simple fabrication process on the silicon substrate. The micro gas sensors with $SnO_2(Pt)$ and $SnO_2(+CuO)$ showed good selectivity to CO gas among reducing gases and good sensitivity to $H_2S$ that is main component of bad odor, separately.

Implementation of an Artificial Odour Recognition System with Unsupervised Clustering Methods (Unsupervised clustering 방법을 갖는 인공 냄새인식 시스템의 구현)

  • Choi, Chan-Seok;Kim, Jeong-Do;Byun, Hyung-Gi
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.6
    • /
    • pp.310-316
    • /
    • 2001
  • We have been designed and constructed an artificial odour recognition system(electronic nose system) using metal oxide type sensor array for recognizing and analyzing various odours. We proposed an unsupervised clustering method based on Euclidean distances in order for human observer to examine easily multi-dimensional data, which has been measured from an array of sensors. This is a combination of Principal Components Analysis(PCA) used as a starting point for Sammom Mapping Method(SMM). No prior assumptions are made of the classes in which odour belong, and the error due to dimensional reduction at the PCA can be minimized without the disadvantages of rotation of clusters when the order of data sets in a data base was changed in the SMM. An artificial odour recognition system with the proposed unsupervised clustering method was applied to assessment of odour differences of Volatile Organic Compounds(VOCs) and Korean whiskies respectively, and demonstrated the best performances throughout the experimental trails.

  • PDF

A Consideration on the DOA Estimation and Signal Copy for Multiple Moving Sources (시변 다중 신호원의 DOA 추정 및 신호 취득에 대한 고찰 예)

  • Kwon, S.;Lee, J.;Park, M.K.;Kim, S.J.;Kim, C.K.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.1811-1812
    • /
    • 2006
  • 본 논문은 공간상에서 움직이는 다중신호원의 신호 도달 방향 추정과 신호원이 보낸 신호를 다중 센서 어레이를 이용하여 판별하는 문제를 다룬다. 일반적으로 정지하고 있는 신호원의 방향 추정은 어레이에서의 출력 방정식의 방향 벡터들이 시불변인 상수이기 때문에 잡음환경 하에서도 샘플링된 벡터(Snapshot) 수가 늘어날수록 훨씬 정확하게 방향 추정이 가능하지만 신호원이 움직이는 경우에는 신호원의 방향이 변하게 되어 결국 어레이 방정식의 방향 벡터들이 시변이므로 추정값의 분산(variance)이 커지게 되어 정확한 추정이 어렵게 된다. 이러한 경우에 대한 정량적인 분석 예는 드물어 실제 여러 가지 추정 기법들의 특성이 어떻게 나타나는지 가늠하기가 어렵다. 따라서 본 논문에서는 이러한 경우에 대한 시나리오 예를 설정한 후 이 시나리오에 따른 랜덤 가우시안 잡음 하에서의 수치 데이터 모델을 생성하여 수신기에서는 미지의 값인 이 데이터에 대해 기존의 DOA 추정 기법을 이용하여 추정을 수행하여 그 정량적인 결과들을 계산해 봄으로써 시변인 경우에서의 그 성능을 판단해 보기로 한다.

  • PDF

Performance Improvement of Towed Array Shape Estimation Using Interpolation (보간법을 이용한 견인 어레이 형상 추정 기법의 성능 개선)

  • 박민수;도경철;오원천;윤대희;이충용
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.3
    • /
    • pp.72-76
    • /
    • 2000
  • A calibration technique is proposed to improve the performance of 2-D towed array shape estimation using the Kalman filter. In the case of using displacement sensors, 2-D hydrophone positions estimated by the Kalman filter are calculated by assuming that the adjacent hydrophones are horizontally equi-spaced so that maximum distance is equal to the array length. The assumption causes errors in estimating hydrophone positions. The proposed technique using linear model approximation or spline interpolation can reduce the errors by exploiting the fact that the whole length of array is preserved whatever the array shape is. The numerical experiments show that the proposed method is very effective.

  • PDF

The Hand Posture Recognition Using IR-Sensor Array (적외선센서 어레이를 이용한 손동작 검출 방법)

  • Song, Tae-Houn;Jeong, Soon-Mook;Jung, Hyun-Uk;Kwon, Key-Ho;Jeon, Jae-Wook
    • 한국HCI학회:학술대회논문집
    • /
    • 2009.02a
    • /
    • pp.432-435
    • /
    • 2009
  • This paper proposes a hand posture recognition with pattern-matching method, embedding a simple paradigm using an Infrared sensor array. Our pattern-matching based hand posture recognition is specification supports fun and the user experience when communicating between humans and telecommunication devices, including robots. Our non-contact type input device (IR-Sensor Array) transmits commands to control mobile robots. It can also control Google Earth’s map searching programs, and other applications.

  • PDF

Reliability improvement of an ion-measuring system using FET sensor array (FET 센서 어레이를 이용한 이온 측정 시스템의 신뢰도 개선)

  • Choi, Jung-Tae;Lee, Seung-Hyup;Kim, Young-Jin;Lee, Young-Chul;Cho, Byung-Woog;Sohn, Byung-Ki
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.341-346
    • /
    • 1999
  • In general cases, compared with glass electrode, FET type electrolyte sensors have many advantages. But the drift, memory effect and the poor reproducibility of the FET type electrolyte sensor cause the decrease of the reliability in the measurement system. To improve the reliability, an ion-measuring system using FET type electrolyte sensor array with 8 sensors has been developed. Developed system employed the electronic switchs to connect a signal detecting circuit with 8 sensor array and the system can measure ion concentration of 4 different type electrolyte($H^+$, $Na^+$, $K^+$, $Ca^{2+}$). The signal processing algorithm with insertion sorting method was adopted to enhance the reliability. We measured 3 different ion($H^+$, $Na^+$, $K^+$) to evaluate the performance of developed system. The results show that the designed signal processing algorithm can reduce the error range in comparison with a simple arithmetic mean and the developed system has a good reliability over the previous single channel sensor system.

  • PDF