• Title/Summary/Keyword: 양정(head)

Search Result 102, Processing Time 0.032 seconds

Identification and Chemotype Profiling of Fusarium Head Blight Disease in Triticale (국내 재배 트리티케일에 발생한 붉은곰팡이병의 다양성 및 독소화학형 분석)

  • Yang, Jung-Wook;Kim, Joo-Yeon;Lee, Mi-Rang;Kang, In-Jeong;Jeong, Jung-Hyun;Park, Myoung Ryoul;Ku, Ja-Hwan;Kim, Wook-Han
    • Research in Plant Disease
    • /
    • v.27 no.4
    • /
    • pp.172-179
    • /
    • 2021
  • This study aimed to assess the disease incidence and distribution of toxigenic in Korean triticale. The pathogen of triticale that cause Fusarium head blight were isolated from five different triticale cultivars that cultivated in Suwon Korea at 2021 year. The 72 candidate were classified as a Fusarium asiaticum by morphology analysis and by ITS1, TEF-1α gene sequence analysis. And the results of pathogenicity with 72 isolates on seedling triticale, 71 isolates were showed disease symptom. Also, seven out of 71 Fusarium isolates were inoculated on the wheat, to test the pathogenicity on the different host. The results showed more low pathogenicity on the wheat than triticale. The results of analysis of toxin type with 72 isolates, 64.6% isolates were produced nivalenol type toxin and other 4.6% and 30.8% isolates were produce 3-acetyldeoxynivalenol and 15-acetyldeoxynivalenol, respectively. To select fungicide for control, the 72 Fusarium isolates were cultivated on the media that containing four kinds fungicide. The captan, hexaconazole, and difenoconazole·propiconazole treated Fusarium isolates were not showed resistance response against each fungicide. However, six isolates out of 72 isolates, showed resistance response to fludioxonil. This study is first report that F. asiaticum causes Fusarium head blight disease of triticale in Korea.

A Study on Process Optimization for CSOs Application of Horizontal Flow Filtration Technology (수평흐름식 여과기술의 CSOs 적용을 위한 공정 최적화 연구)

  • Kim, Jae-Hak;Yang, Jeong-Ha;Lee, Young-Shin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.56-63
    • /
    • 2018
  • The management of Combined Sewer Overflows(CSOs) and Separated Sewer Overflows(SSOs) discharge directly to the effluent system in an untreated state, which occurs when the facility capacity is exceeded due to heavy rain, has become an important issue in recent years as the heavy rain becomes a regular phenomenon. Despite the continuous development of filtration technology, targeting densely populated urban areas, CSOs are rarely applied. Therefore, this study was carried out to optimize the process to apply CSOs in a pilot-scale horizontal flow filtration system with a rope-type synthetic fiber. The research was carried out in two steps: a preliminary study using artificial samples and a field study using sewage. In the preliminary study using an artificial sample, head loss of the filter media itself was analyzed to be approximately 1.1cm, and the head loss was increased by approximately 0.1cm as the linear velocity was increased by 10m/hr. In addition, the SS removal efficiency was stable at 81.4%, the filtration duration was maintained for more than 6 hours, and the average recovery rate of 98% was obtained by air backwashing only. In the on-site evaluation using sewage, the filtration duration was approximately 2 hours and the average removal efficiency of 83.9% was obtained when belt screen (over 450 mesh) was applied as a pre-treatment process to prevent the premature clogging of filter media. To apply the filtration process to CSOs and SSOs, it was concluded that the combination with the pre-treatment process was important to reinforce the hydraulic dimension for the stable maintain of operation period, rather than efficiency. Compared to the dry season, the quality of incoming sewage was lower in the rainy season, which was attributed to the characteristics of the drainage area with higher sanitary sewerage. In addition, the difference in removal efficiency according to the influent quality of the wet season and dry season was small.

Development of Drainage Pump for Rescue Sinking Ship (침수선박 구조를 위한 대용량 배수펌프 개발)

  • Kim, Kyeong-Soo;Jung, Kang-Hyun;Kim, Hae-Young;Kim, Nam-Hun;Cho, Je-Hyoung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.3
    • /
    • pp.248-254
    • /
    • 2015
  • There has been no previous study on technology development of large capacity drainage pump for rescue sinking ship in the country. The agricultural drainage pump was widely used for rescue sinking ship but this pump has several problems such as efficiency, low displacement and malfunction in winter. Therefore, this paper proposes to solve the problems for swiftly rescue sinking ship and develops the drainage pump system that has $20m^3/min$ mass flow rate specification at suction head 8 m. The centrifugal pump type the most commonly used in the field of naval architecture and ocean engineering was selected and designed based on the requirement specification. The blade design of impeller was derived from the Stepanoff coefficient and requirement specification and used computational fluid dynamics to review the target mass flow rate according to the impeller RPM at design operating conditions. We also performed structure analysis of the impeller to find structurally vulnerable points for the pump in service and completed the theoretical design of drainage pump system.

Cavitation Analysis on Ship Seawater Pump Using CFD (CFD를 이용한 선박용 해수펌프의 공동현상에 대한 분석)

  • Kim, Bu-Gi;Kim, Hong-Ryeol;Yang, Chang-Jo;Kim, Jun-Ho
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.4
    • /
    • pp.400-406
    • /
    • 2017
  • The model used in this study was reversed to analyze the cause of excessive damage that occurred inside the rotating system and pipe system of a centrifugal-type seawater pump on a ship. For this purpose, internal flow analysis on a cooling seawater pump was performed using CFD. As a result, the shape and boundary conditions of the target pump were set by reverse engineering, and pump efficiency at a design operating point of $125m^3/h$ was calculated as 85.3 % with a head of 32.0 m. The maximum efficiency point of the target pump was estimated to be 86.2 % at $150m^3/h$, but this differed from the actual operating point. At $112.5m^3/h$, which was the lowest flow point, flow was unstable due to the characteristics of the low flow point and analysis convergence was not good. The purpose of this study was to clarify the cause of ongoing cavitation in seawater pumps and piping systems in operation. Future research will be needed to clarify causes for pipe systems in the future by performing calculations for the total piping system of an inlet and outlet, in addition to measuring the flow rate of each branch pipe.

Optimal Design of Branched Water Supply System with GIS (GIS를 이용한 분기형 관로의 최적설계)

  • Kim, Joong-Hoon;Yeon, Sang-Ho;Geem, Zong-Woo
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.4 no.2 s.8
    • /
    • pp.55-61
    • /
    • 1996
  • The objective of this paper is to show an optimal design model for branched water supply system which also can find the optimal location of pumping stations using linear programming. GIS is utilized in this model to better handle the data and the results front the optimization. The developed model considers hydraulic influences of some appurtenances such as supply tunnels and a filtration plant The model also considers tunnel construction cost which should be treated differently from pipe construction cost Different from other models presently available, the model guarantees a nonnegative pressure at every junction node in the system. The objective function includes annual operation cost (electricity rate) ill addition to initial construction cost, thus producing a more reasonable decision. The model selects the optimal diameter not in the form of continuous number but in the form of commercial discrete diameter (pipe size) using the pipe lengths as decision variables instead of pipe diameters. The model not only determines the optimal pumping head for each pumping station but also finds the optimal location and number of pumping stations. GIS is used to handle hydraulic and budgetary data automatically and to visualize the results for the of optimal design of the system. The model has been applied to an existing water supply system. 'The results show that the optimization model with the aid of GIS is helpful in the decision-nulling process for the design of more economical systems, and can be dot into practice successfully.

  • PDF

Current Status of Pediatric Surgical Practice in Korea -a Survey among the Members of Korean Association of Pediatric Surgeons- (대한소아외과학회 회원의 1995년도 진료현황 및 수련경력 설문조사)

  • Kim, W.K.;Kim, S.Y.;Kim, S.K.;Kim, I.K.;Kim, J.E.;Kim, C.S.;Kim, H.H.;Park, K.W.;Park, Y.S.;Park, W.H.;Park, J.S.;Song, Y.T.;Yang, J.W.;Oh, S.M.;Lee, D.S.;Lee, M.D.;Lee, S.K.;Lee, S.C.;Chang, S.I.;Jung, S.E.;Jung, P.M.;Choi, K.J.;Choi, S.O.;Huh, Y.S.;Hwang, E.H.
    • Advances in pediatric surgery
    • /
    • v.3 no.1
    • /
    • pp.61-67
    • /
    • 1997
  • To understand the current status of pediatric surgical practice of the members of the Korean Association of Pediatric Surgeons, a survey of the practice of the 31 members in both 1994 and 1995. Twenty five members(80%) representing 20 hospitals responded. An average of four hundred and seventy four cases pediatric surgical operations were performed at individual institution in 1995 with 40 newborn cases. Eighteen members(72%) are currently working at university hospital. Fourteen institutions(70%) are currently classified as tertiary by the health insurance agency. The majority(15 to 60%) of members are working in the metropolitan Seoul area, while five in Taegu area. Sixteen members reported having the title of department head/director. Four members reported occasional non-pediatric surgical practice. Nine members out of 20 reported having independent pediatric surgical out-patient clinic before the establishment of the association(1985). Eight out of 15 members reported being appointed chief of pediatric surgery before 1985. In 20 institutions, 34 full time physicians(27 members, reportedly) are working in pediatric surgery. In regarding to pediatric surgical training, 16 members(64%) received an average of 16 months of training abroad, 5 members trained at home and abroad, and 4 from only at home. There are no differences in length of training periods in these groups. Twenty one members received their basic pediatric surgical training before 1985, the year of inauguration of the association. Twelve members received post-pediatric surgery refresher courses averaging 11 months' duration, after 2-11 years. Thirteen participants of this study belongs to the founding members of the association.

  • PDF

Inflammatory Polyps in 2 Cats (두 마리 고양이에서의 염증성 용종 예)

  • Ko, Seung-Bo;Jung, Ji-Youl;Kim, Jae-Hoon;Kang, Sang-Chul;Yoon, Jeong-Sik;Yang, Jung-Hwan;Shin, Yong-Eun;Kim, Jae-Hoon
    • Journal of Veterinary Clinics
    • /
    • v.27 no.5
    • /
    • pp.622-625
    • /
    • 2010
  • Inflammatory polyps in feline ear are nonneoplastic, inflammatory growths that arise from the middle ear or the eustachian tube and extended into the pharynx or external ear canal. Two 2-year-old female Russian blue cats showed 2-3 weeks history of aural discharge, crust formation in external ear, and head or ear shaking. Two masses were surgically excised from ear canal, and submitted for diagnosis. Histopathologically, these masses were covered with hyperplastic ciliated epithelium or nonkeratinizing squamous epithelium with partial erosion and ulceration. The core of masses was consisted of proliferated connective tissue and massive infiltration of mononuclear cells. Immunohistochemically, about 90% of infiltrated mononuclear cells demonstrated CD3 positive T cell. According to both polymerase chain reaction (PCR) and reverse transcriptase-PCR, tissues samples were negative for feline viral pathogens. Based on the clinical, gross, histopathologic findings, these two cases were diagnosed as inflammatory polyps originated from the middle ear in cats.

Behavioural Analysis of Asiatic Black Bear in Limited Space (제한된 공간에서 반달가슴곰의 행동학적 특성 분석)

  • Jeong, Dong-Hyuk;Lee, Bae-Keun;Yang, Jeong-Jin;Park, Jong-Seong;Suh, Euy-Hoon;Kim, Young-Ki;Lee, Hee-Cheon;Lee, Hyo-Jong;Yeon, Seong-Chan
    • Journal of Veterinary Clinics
    • /
    • v.26 no.3
    • /
    • pp.246-258
    • /
    • 2009
  • This study was conducted for behavioral characteristic analysis of the Asiatic Black Bear in a limited space. Behaviors of eight Asiatic Black Bears were classified into 13 normal stances and locomotor activities, 15 normal maintenance behaviors, 9 locomotory compulsive behaviors, 2 non-locomotory compulsive behaviors through the 3 years of monitoring. The bears had originally been released into the Jiri National Park for Asiatic Black Bear Restoration Project and were withdrawn again because of several reasons such as habituation to humans, and apiary damage. Through the monitoring of 6 hours per day during 3 months, classified behaviors were analyzed based on sex, age, observing month, observing timing, captivity period, and captive form. The total rate of stereotypic behaviors was $26.51{\pm}13.38%$. Among these, RA(Rest_A) was rated high as $47.32{\pm}18.32%$. In addition, SP(Standard pace), HR(Head rear), EP(Extended pace) were most frequently observed behaviors. The time budget of TFS(Two feet stand), SA(Sniff_A) and SB(Sniff_B) on females and younger individuals were relatively higher than male and older individuals. So we confirmed that females and younger individuals had more wariness and curiosity. As the period of captivity took longer, the rate of stereotypic behaviors was higher and more stereotypic behaviors were observed in the afternoon. At night, behaviors related with resting like Rest-A, Rest-B, Lying down, Lying on abdomen, Sitting were more frequently observed. We concluded that the captive state could affect the behaviors of Asiatic Black Bear and long term research should be necessary.

Performance Test of a 7 tonf Liquid Rocket Engine Turbopump (7톤급 액체로켓엔진용 터보펌프 조립체 성능시험)

  • Kwak, Hyun Duck;Kim, Dae-Jin;Kim, Jin-Sun;Kim, Jinhan;Noh, Jun-Gu;Park, Pyun-Goo;Bae, Jun-Hwan;Shin, Ju-Hyun;Yoon, Suck-Hwan;Lee, Hanggi;Jeon, Seong-Min;Jeong, Eunhwan;Choi, Chang-Ho;Hong, Soon-Sam;Kim, Seong-Lyong;Kim, Seung-Han;Han, Yeong-Min
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.2
    • /
    • pp.65-72
    • /
    • 2015
  • Performance tests of a turbopump for the developing 7-tonf liquid rocket engine were conducted. The performance of turbopump components and their power matching were measured and examined firstly under the LN2 and water environment. In the real propellant(LOX and kerosene) environment tests, design and off-design performances of turbopump were fully verified. During the off-design tests, turbopump running time was set the same as engine operating time and pump inlet pressure were set lower than nominal operating value in order to investigate pump suction capability. It have been verified that subject turbopump satisfies required performance - flow rate, head, suction performance and operational time - in the operating regime of developing liquid rocket engine.

Design of the Condenser and Automation of a Solar Powered Water Pump (태양열 물펌프의 운전 자동화 설계)

  • Kim Y. B.;Son J. G.;Lee S. K.;Kim S. T.;Lee Y. K.
    • Journal of Animal Environmental Science
    • /
    • v.10 no.3
    • /
    • pp.141-154
    • /
    • 2004
  • The solar powered water pump is very ideal equipment because solar power is more intensive when the water is more needed in summer and it is very helpful in the rural area, in which the electrical power is not available. The average so]ar radiation energy is 3.488 kWh/($m^2{\cdot}day$) in Korea. In this study, the automatic control logic and system of the water pump driven by the radiation energy were studied, designed, assembled, tested and analyzed for realizing the solar powered water pump. The experimental system was operated automatically and the cycle was continued. The average quantity of the water pumped per cycle was about 5,320 cc. The cycle time was about 4.9 minutes. The thermal efficiency of the system was about $0.030\%$. The pressure level of the n-pentane vapour in flash tank was 150$\%$450 hPa(gauge) which was set by the computer program for the control of the vapour supply. The pressure in the condenser and air tank during cycles was maintained as about 600 hPa and 1,200 hPa respectively. The water could be pumped by the amount of 128kg/($m^2{\cdot}day$) with the efficiency of $0.1\%$ and the pumping head of 10 m for the average solar energy in Korea.

  • PDF