• Title/Summary/Keyword: 양극부

Search Result 89, Processing Time 0.302 seconds

Effect of Vinyl Ethylene Carbonate on Electrochemical Characteristics for Activated Carbon/Li4Ti5O12 Capacitors (활성탄/리튬티탄산화물 커패시터의 전기화학적 특성에 미치는 비닐에틸렌카보네이트의 영향)

  • Kwon, Yong-Kab;Choi, Ho-Suk;Lee, Joong-Kee
    • Journal of the Korean Electrochemical Society
    • /
    • v.15 no.3
    • /
    • pp.190-197
    • /
    • 2012
  • We employed the vinyl ethylene carbonate (VEC) as an electrolyte additive and investigated the effect of the electrolyte additive on the electrochemical performance in hybrid capacitor. The activated carbon was adopted as cathode material, and the $Li_4Ti_5O_{12}$ oxide was used as anode material. The electrolyte was prepared with the $LiPF_6$ salt in the mixed solvent of ethylene carbonate (EC), dimethyl carbonate (DMC), and ethyl methyl carbonate(EMC). We evaluated the electrochemical performance of the hybrid capacitor with increasing the amount of the VEC electrolyte additive, which is known as the remover of oxygen functional group and the stabilizer of the electrode by reducing the surface of electrode, and obtained the superior performance data especially at the addition of the VEC electrolyte additive of around 0.7 vol%. On the contrary, the addition of the VEC more than 0.7 vol% in the electrolyte leads to the degradation in electrochemical performance of hybrid capacitor, suggesting the increase of the side reaction from the excessive VEC additive. X-ray photoelectron spectroscopy (XPS) revealed that the addition of the VEC suppressed the formation of LiF component, which is known as the insulator, on the surface of electrode. The optimized addition of VEC exhibited the improved capacity retention around 82.7% whereas the bare capacitors without VEC additive showed the 43.2% of capacity retention after 2500 cycling test.

Electrochemical Reduction Process for Pyroprocessing (파이로프로세싱을 위한 전해환원 공정기술 개발)

  • Choi, Eun-Young;Hong, Sun-Seok;Park, Wooshin;Im, Hun Suk;Oh, Seung-Chul;Won, Chan Yeon;Cha, Ju-Sun;Hur, Jin-Mok
    • Korean Chemical Engineering Research
    • /
    • v.52 no.3
    • /
    • pp.279-288
    • /
    • 2014
  • Nuclear energy is expected to meet the growing energy demand while avoiding CO2 emission. However, the problem of accumulating spent fuel from current nuclear power plants which is mainly composed of uranium oxides should be addressed. One of the most practical solutions is to reduce the spent oxide fuel and recycle it. Next-generation fuel cycles demand innovative features such as a reduction of the environmental load, improved safety, efficient recycling of resources, and feasible economics. Pyroprocessing based on molten salt electrolysis is one of the key technologies for reducing the amount of spent nuclear fuel and destroying toxic waste products, such as the long-life fission products. The oxide reduction process based on the electrochemical reduction in a LiCl-$Li_2O$ electrolyte has been developed for the volume reduction of PWR (Pressurized Water Reactor) spent fuels and for providing metal feeds for the electrorefining process. To speed up the electrochemical reduction process, the influences of the feed form for the cathode and the type of anode shroud on the reduction rate were investigated.

Calculation of Rainwater and Groundwater Fraction in Sewerage: A Case Study in Deokjin Park, Jeonju (동위원소를 이용한 하수 내 지하수 및 우수 함량 산출: 전주 덕진공원 유역 사례)

  • Choi, Seung-Hyun;Kim, Kangjoo;Moon, Sang-Ho
    • Economic and Environmental Geology
    • /
    • v.49 no.5
    • /
    • pp.361-370
    • /
    • 2016
  • It is well known that the inflow of rainwater and the infiltration of groundwater to sewerage (I/I) increase the sewage and burden sewage treatment plants and lower their treatment efficiency. Therefore, it is important to estimate the amount of I/I. In this study, well groundwaters, public water supplies (PWSs), and sewage and rainwater channels were investigated to check whether oxygen and deuterium isotopes could be used as a tool for I/I estimation. This study shows that the isotopic composition of PWS in Jeonju area is very consistent over time and distinctly lighter than the circulating local rainwater (CLR) because it is supplied from Yongdam Dam, which is located about 40 km inland to the east in the mountainous area. Considering the fact that sewage mostly originates from the PWS, we could calculate the amounts of CLR in the sewerage from a monitoring station using unaffected rainwater and tap water as mixing end members. The calculation revealed that the CLR fraction ranged from 50% to 90% depending on observation time. This is well supported by the dilute natures of the sewages at the station. The fraction of PWS in investigated well waters were about 46%, indicating that leaking of PWS is very serious and is an important groundwater source in the study area. Since the infiltration of such groundwater may not alter the isotopic composition of sewage significantly, the actual I/I would be much greater than the calculated ones.

PERFORMANCE OF FIMS MICROCHANNEL PLATE DETECTOR SYSTEM (FIMS의 마이크로채널 플레이트 검출기 시스템의 특성)

  • Nam, U.W.;Rhee, J.G.;Kong, K.N.;Park, Y.S.;Jin, K.C.;Jin, H.;Park, J.H.;Yuk, I.S.;Seon, K.I.;Han, W.;Lee, D.H.;Ryu, K.S.;Min, K.W.;Edelstein, J.;Korpela, E.
    • Journal of Astronomy and Space Sciences
    • /
    • v.19 no.4
    • /
    • pp.273-282
    • /
    • 2002
  • We describe some performance of the detector electronics system for the FIMS (Far-ultraviolet Imaging Spectrograph) mission. The FIMS mission to map the far ultraviolet sky uses MCP (micro-channel plate) detectors with a crossed delay line anode to record photon arrival events. FIMS has two MCP detectors, each with a ~25mm$\times$25mm active area. The unconventional anode design allows for the use of a single set of position encoding electronics for both detector fields. The centroid position of the charge cloud, generated by the photon-stimulated MCP, is determined by measuring the arrival times at both ends of the anode following amplification and external delay. The temporal response of the detector electronics system determines the readout's positional resolution for the charge centroid. High temporal resolution (<$35{\times}75$ps FWHM) and low power consumption (< 6W) were achieved for the FIMS detector electronics system.

Development of an electron source using carbon nanotube field emittes for a high-brightness X-ray tube (탄소나노튜브를 이용한 고휘도 X-선원용 전자빔원 개발)

  • Kim, Seon-Kyu;Heo, Sung-Hwan;Cho, Sung-Oh
    • Journal of the Korean Vacuum Society
    • /
    • v.14 no.4
    • /
    • pp.252-257
    • /
    • 2005
  • A high-brightness electron beam source for a microfocus X-ray tube has been fabricated using a carbon-nanotube (CNT) field emitter. The electron source consists of cathode that includes a CNT field emitter, a beam-extracting grid, and an anode that accelerates that electron beam. The microfocus X-ray tube requires an electron beam with the diameter of less than 5 $\mu$m and beam current of higher than 30 $\mu$A at the position of the X-ray target. To satisfy the requirements, the geometries of the field emitter tips and the electrodes of the gun was optimized by calculating the electron trajectories and beam spatial profile with EGUN code. The CNT tips were fabricated with successive steps: a tungsten wire with the diameter of 200 $\mu$m was chemically etched and was subsequently coated with CNTs by chemical vapor deposition. The experiments of electron emission at the fabricated CNT tips were performed. The design characteristics and basic experimental results of the electron source are reported.

Assessment of Systemic Arterial Thromboembolism with Multi-Slice Spiral CT in a Dog (개에서 다중나선형 CT촬영에 의한 동맥혈전색전증의 평가)

  • Shin, Seung-Ho;Lee, Ki-Chang
    • Journal of Veterinary Clinics
    • /
    • v.24 no.2
    • /
    • pp.208-213
    • /
    • 2007
  • A 15 kg 6-year-old intact male Jindo dog with a history of a respiratory distress, hindlimb paralysis with necrosed skin of dorsal digit for three weeks was referred to Animal Medical Center, Chonbuk National University. Heartworm infection was identified by kit examination. In plain thoracic radiographs, dilated pulmonary arteries reverse D sign and focal interstitial pattern was compatible with heartworm infection and possible pulmonary thromboembolism. Abdominal radiographs showed poor serosal detail indicating fluid accumulation within peritoneal cavity. No evidence of musculoskeletal abnormalities was found. Ultrasonography presented focal wedge-shaped hyperechogenecity on the both poles of left kidney, weak or absent pulse on the distal to the external iliac artery as well as ascites and irregular liver margin. Multi-organ failure was strongly supposed by blood profile including leukocytosis, anemia, hemoglobinuria bililubinemia, hypoalbuminemia, imbalance of electrolytes, and increased hepatic and renal function values. Interestingly, the glucose level is remarkably lower in pelvic limb compared to thoracic limb. Suspected pulmonary thromboembolism, renal infarction and femoral arterial embolization causing hindlimb paralysis and dermatic necrosis were confirmed by 3D reconstructed CT imaging. Prior to taking a consideration of euthanasia, interventional radiology was experimentally attempted but failed due to not recovered from general anesthesia. Early and accurate diagnosis of thromboembolism is valuable and 3D reconstructed CT images might be very useful to show the correct way to treat effectively.

Durability Test of PEMFC Membrane by the Combination of Chemical/Mechanical Degradation (화학적/기계적 열화 병행방법에 의한 PEMFC 고분자막 내구성 평가)

  • Lim, Daehyeon;Oh, Sohyeong;Jung, Sunggi;Jeong, Jihong;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.59 no.3
    • /
    • pp.339-344
    • /
    • 2021
  • In order to improve the PEMFC (Proton Exchange Membrane Fuel Cell) durability, it is important to accurately evaluate the durability of the membrane in a short time. Recently, DOE (Department of Energy) reported a protocol that combines the chemical and mechanical durability of membranes to evaluate them effectively. This protocol applies chemical/mechanical deterioration to the membrane by repeating wet/dry while OCV (Open Circuit Voltage) holding. The problem of this protocol is that it is highly affected by electrode degradation due to change cycles in OCV and that the evaluation time is long. By using oxygen instead of air as the cathode gas while leaving the other conditions of the DOE protocol as it is, the durability evaluation time could be reduced from 408 hours to 144 hours. By reducing the number of voltage change cycles to 1/3, the electrode degradation due to the voltage change cycle was reduced to 1/12 when oxygen was used compared to air at the end, thereby enabling more accurate evaluation of polymer membrane durability.

THE MORPHOLOGICAL OBSERVATION OF HUMAN PERIODONTAL LIGAMENT CELLS ATTACHMENT AND SPREADING ON THE SURFACE OF SLIDE GLASS (치주인대세포의 부착과 전개에 관한 형태학적 관찰)

  • Lee, Jin-Mi;Suh, Jo-Young;Park, Joon-Bong
    • Journal of Periodontal and Implant Science
    • /
    • v.23 no.1
    • /
    • pp.97-108
    • /
    • 1993
  • One of the important initial events required for periodontal regeneration is the attachment and subsequent spreading of periodontal ligament cells on the root surface. The purposes of this study is to investigate the attachment and spreading pattern of human periodontal ligament cell on the surface of glass slides. After establishment of a cell line of the primary cell culture from the periodontal ligament of 1st premolar teeth which were extracted for the purpose of orthodontic treatment, author dispersed the cells at $5{\times}10^3\;cells/ml$ into the each 35mm culture petri-dish containing 2 glass slides. To observe the morphological changes of the cells which attached to the surfaces of glasses at every designed time schedule, author used the inverted phase contrast microscope and scanning electron microscope. During the whole experiment culture condition was at $37^{\circ}C$, 100% Humidity, 5% $CO_2$ gas incubator. The following results were obtained. Periodontal ligament cells showed spherical outline and started to attach to glass surface by basal sytoplasmic extension after 10min in culture. After 30min in culture, periodontal ligament cells were attached to glass surface by well - developed filopodia which protruded from the lamellipodia. The cell surface is covered with bubble-like structures and occasional microvillus can be seen with diffculty among these structures. After 1.5hr in culture, peridontal ligament cells shhowed radially well-spread cytoplasm and the nucleus was centered on its cytoplasm. Unspread central region of the cell was covered with numerous microvilli. The change of cell attachment and spreading pattern was manifest at 6hr in culture. At this time, periodontal ligament cell showed elongated outline and an oval-shaped nucleus. After 12hr in culture, periodontal ligament cells showed more stretched fibroblast-like appearance with polarity. Two long lamellipodia can be seen around the both terminal ends of cells. After 24hr in culture, periodontal ligament cells showed spindle shapes and an oval-shaped nucleus was slanted toward one side of the cell.

  • PDF

On the osseointegration of zirconia and titanium implants installed at defect site filled with xenograft material (이종골 이식을 동반한 지르코니아와 타이타늄 임플란트의 골유착에 관한 연구)

  • Kim, Sung-Won;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.1
    • /
    • pp.9-17
    • /
    • 2014
  • Purpose: The purpose of this study was to compare zirconia implants with titanium implants from the view point of biomechanical stability and histologic response on osseointegration when those were placed with xenograft materials. Materials and methods: Specimens were divided into two groups; the control group was experimented with eighteen titanium implants which had anodized surface and the experimental group was experimented with eighteen sandblasted zirconia (Y-TZP) implants. At the tibias of six pigs, implants were installed into bone defect sites prepared surgically and treated with resorbable membranes and bovine bone. Two pigs were sacrificed after 1, 4 and 12 weeks respectively. Each implant site was sampled and processed for histologic and histomorphometric analysis. The stability of implants was evaluated with a $Periotest^{(R)}$. And the interfaces between bone and the implant were observed with a scanning electron microscope. Results: In stability analysis there was no significant difference between Periotest values of the control group and the experimental group. In histologic analysis with a light microscope after 4 weeks, there was new bone formation with the resorption of bovine bone and the active synthesis of osteoblasts in both groups. In bone-implant contact percentage there was significant difference between both groups (P<.05). In bone area percentage there was no significant difference between both groups. In analysis of both groups with a scanning electron microscope there was a gap between bone and a surface at 4 weeks and it was filled up with bone formed newly at 12 weeks. Conclusion: When accompanied by xenograft using membrane, bone to implant contact percentage of zirconia implants used in this experiment was significantly less than that of the titanium implants by surface treatment of anodic oxidation. So, it is considered that the improvement of zirconia implant is needed through ongoing research on surface treatment methods for its practical use.