• Title/Summary/Keyword: 양극각도

Search Result 12, Processing Time 0.022 seconds

Property of Focal Spot of Electron Beam Depending on the Anode Angle of X-ray Tube Using a Finite Element Method (유한요소법을 이용한 X-선관 양극각도에 의존하는 전자빔 초점 특성 연구)

  • Park, Tae-Young;Noh, Young-Il;Lee, Sang-Suk;Park, Rae-Jun;Kim, Ki-Seon
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.2
    • /
    • pp.52-57
    • /
    • 2015
  • The focal spot of electron beam depending on the anode angle in the structure and major parts of the X-ray tube was investigated by the OPERA-3D/SCALAR simulation program. The simulation worked on four spaces with with two spaces, including anode and cathode of X-ray tube, by applying the finite element method analysis. The analytical model and dimension for the emission orbit of thermal electrons made from one filament of the focused X-ray cathode is affected to the penumbra of detector for the X-ray depending on any real focal spot size. The model shape of focusing cap and focusing tube with an anode target angle and a cathode filament is analyzed by the current density distribution of thermal electrons. The focusing width of thermal electrons for the X-ray tube depended on the anode angle (${\theta}$). The focusing value of electron beams at a region of anode angle having $10^{\circ}{\sim}17^{\circ}$ maintained to below value of $70{\mu}m$. The minimum focal size of the electron beam was $40{\mu}m$ at an anode angle of $15^{\circ}$. The focused X-ray tube of many variables depended on the thermionic emission of hot electrons from the target trajectory. The focusing tube will contribute to the real design of X-ray for the development of future diagnosis medical device.

The Anode Heel Effect caused by changing the Angle of X-Ray Tube (X-선관 각도 변경에 따른 Anode Heel Effect)

  • Shin, Seong-gyu;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.6
    • /
    • pp.435-442
    • /
    • 2016
  • This study was an investigation of the anode heel effect caused by changing the angle of the x-ray tube. We established the following conditions for experimental measurements: 70 kV, 30 mAs, focus-detector distance of 100cm, and a collimator setting of $35{\times}43cm^2$. The measurement points were set up at the center of the collimator and extended to each side in intervals of 3.5cm, with points A1, A2, A3, A4, A5, A6 on the anode side and points C1, C2, C3, C4, C5, C6 on the cathode side. We measured the entrance surface dose from point A6 to point C6 with each point perpendicular to an x-ray tube. And we did the same when measuring different angles of the x-ray tube from 15 to 30 degrees for every point on the anode and cathode sides. Using perpendicular x-ray tube, we found that the entrance surface dose of the A5 point was three times higher than that of the C5 point. Thus, we conclude that if the anode side is placed near highly radiosensitive organs, then there will be less radiation exposure when using a perpendicular x-ray tube. When imaging using x-ray tube angles, an angle to the cathode side can reduce the gap of the entrance surface dose on both the anode and cathode sides. When imaging areas where there are differences in thickness between the upper and lower sides, the angle to the cathode side that is closer to the thicker area can reduce the gap of the entrance surface dose and capture a higher quality image.

의역시공관(醫易時空觀)의 현대자연과학적 의의

  • Jeong, Chang-Hyeon
    • Journal of Korean Medical classics
    • /
    • v.18 no.3 s.30
    • /
    • pp.9-16
    • /
    • 2005
  • 종의역학적각도간(從醫易學的角度看), 우주적팽창일수축반복가설부합음양소장과정. 우주팽창시(宇宙的膨是)‘양생음장(陽生陰長)’, ‘양성음쇠(陽盛陰衰)’적과정(的過程) ; 우주수축시(宇宙收縮是)‘양살음장(陽殺陰藏)’, ‘음성양쇠(陰盛陽衰)’적과정(的過程). 종수축도팽창(從收縮到膨脹), 종팽창도수축(從膨脹到收縮), 기전환점시양극혹음극적상태(其轉換點是陽極或陰極的狀態), 응용(應用)’음극변양(陰極變陽), 양극변음(陽極變陰)‘적음양극변원리(的陰陽極變原理). ${\lceil}$내경(內經)${\rfloor}$인위물질화시공(認爲物質和時空), 시간화공간본질상시일치적(時間和空間本質上是一致的), 도시종기파생출래적(都是從氣派生出來的). ${\lceil}$내경(內經)${\rfloor}$이경인식도료시공적통일성화상대성(已經認識到了時空的統一性和相對性). 저여애인사탄상대론적시공관유상동지처(這與愛因斯坦相對論的時空觀有相同之處). 서방과학적시공관시통과대물질실체이급물질상호관계적관찰이형성적물리시공관(西方科學的時空觀是通過對物質實體以及物質相互關係的觀察而形成的物理時空觀) ; 의역시공관시통과대포괄인류재내적천지만물적일절생명활동현상적관찰이형성적생명시공관(醫易時空觀是通過對包括人類在內的天地萬物的一切生命活動現象的觀察而形成的生命時空觀).

  • PDF

과학기술위성 3호용 홀방식 전기추력기의 개발 및 시험

  • Lee, Jong-Seop;Seo, Mi-Hui;Choe, Won-Ho
    • Bulletin of the Korean Space Science Society
    • /
    • 2009.10a
    • /
    • pp.45.3-46
    • /
    • 2009
  • 홀 추력기는 비교적 간단한 구조와 작은 크기 및 높은 연료효율로 미래 소형위성의 핵심기술로 주목 받고 있다. 이 연구실에서는 2010년 발사예정인 과학기술위성 3호에 탑재할 소형위성용 저 전력 홀 추력기를 연구 개발하였다. 성능에 가장 큰 영향을 미치는 자기장 구조는 FEMM전산코드를 이용한 해석을 통해 설계되었으며, 제작된 프로토타입의 실험을 통해 자기장의 세기 및 모양, 양극전압 및 기체유량에 따른 성능 특성을 관찰하였다. 또한 Faraday Probe와 Retarding Potential Analyzer (RPA), 랑뮈어 탐침 등을 이용해 이온빔의 분사각도 및 전류밀도, 이온에너지 분포, 플라즈마 전위 등을 측정하고 관찰된 특성을 물리적으로 분석하였다. 이러한 최적화 과정을 통해 설계된 비행모델의 시험 결과 양극전력 200 W, 제논 연료유량 0.85 mg/s 을 통해 11.2 mN 추력, 1350 s 비추력, 37% 추력효율을 획득하여 개발목표를 상회하는 만족할만한 결과를 얻었다.

  • PDF

Change of PAE according to Detector Measurement Method (검출기 측정방법에 따른 PAE값의 변화)

  • Im, In-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.6
    • /
    • pp.307-311
    • /
    • 2010
  • The aim of this study is to investigate PAE, as the result of the test of kVp accuracy, according to detector measurement method. Based on the indicated value of 70kVp, each distance between a focus and a kVp meter was 100cm, 80cm and 60cm and the angle of X-ray tube was set on $5^{\circ},\;10^{\circ},\;15^{\circ},\;20^{\circ},\;25^{\circ},\;30^{\circ}$. Each indicated value, 60kVp, 70kVp, 80kVp, 90kVp and 100 kVp, was used compare Small focus with Large focus. As a result, PAE on the side of cathode was higher than it on the side of anode in the case of 100cm and PAE on the side of anode was higher in the case of 80cm and 60cm. The coefficient rate was stable both the side of cathode and anode in the case of 100cm and it was fluctuated in the case of 80cm and 60cm. PAE in the case of Small focus was higher than Large focus and it was disproportionate to an indicated value. Error rate was in inverse proportion to the indicated value.

Visualization of Natural Convection Heat Transfer on Horizontal Cylinder Using the Copper Electroplating System (전기도금계를 이용한 수평관 외부 자연대류의 시각화)

  • Heo, Jeong-Hwan;Chung, Bum-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.1
    • /
    • pp.43-51
    • /
    • 2011
  • Natural convection heat transfer phenomena on a horizontal cylinder have been studied experimentally in order to investigate the applicability of analogy experimental methodology using a copper electroplating system and to visualize the local heat transfer rates depending on the angular position and the diameter of the horizontal cylinder. In the copper electroplating system, the copper ion produced at the anode moves by convection and diffusion to the cathode and reduces at the cathode, representing the heat transfer. By using aluminum cathode with a distinguishable color, the amount of copper plated could visualize the amount of heat transferred depending on the angular position of the cylinder. The diameter of the cylinder is varied from 0.01m to 0.15m, which correspond to Rayleigh numbers in the range of $1.73{\times}10^7$ to $5.69{\times}10^{11}$. The test results are in good agreement with existing heat transfer correlations.

Distribution of X-ray Strength in Exposure Field Caused by Heel Effect (양극의 경사각 효과에 따른 조사야 X-선 강도 분포)

  • Jang, Keun-Jo;Kim, Nam-Hun;Lee, Jun-Haeng;Lee, Sang-Bock
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.223-229
    • /
    • 2011
  • When negative electron in x-ray tube is accelerated in to a high speed and then the currency of the electron is blocked by the target, x-ray happens by the conversion of the energy. The real area where the fast accelerated electron collides to a target area is called actual focal spot. When the string focused size is observed at the central ray side, where the direction x-ray comes out, the size seems to be reduced. This focus is called effective focal spot. According to radiation angle of x-rays tube, the degree of the negative pole side presents higher value than inclination, the amount of exposed radiation that patient receives differs by the angle of positive pole, which means effective focal spot is the variable. This paper presents the correlation between size of effective focal spot and amount of exposed radiation to the patient by it, and effective research for homogenized dose dispersion by the size of effective focal spot. In conclusion, following the focal size, effective range which was -8cm ~ 0 cm on average, was found and average dose rate was 0.019 R/min. Through this range, for patients with small radiation exposure, image with good density and resolution in aspect of diagnosing will be able to be obtained.

Study on the evaporation of high melting temperature metal by using the manufactured electron hem gun system (전자총 시스템 제작과 이를 이용한 고융점 금속 증발에 관한 연구)

  • 정의창;노시표;김철중
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.1
    • /
    • pp.1-6
    • /
    • 2003
  • An axial electron beam gun system, which emits the electron beam power of 50 kW, has been manufactured. The electron beam gun consists of two parts. One is the electron beam generation part. including the filament, cathode, and anode. The maximum beam current is 2 A and the acceleration voltage is 25 kV. The other part includes the focusing-, deflection-, and scanning coils. The beam diameter and ham trajectory can be controlled by these coils. The characteristic of each part is measured ior the optimum condition of evaporation process. Moreover, Helmholtz coil is installed inside the vacuum chamber to adjust the incident angel of the beam to the melting surface for the maximum evaporation. We report on the evaporation rates for zirconium(Zr) and gadolinium(Gd) metals which have the high melting temperatures.

A Study on Close-loop Feedback Control for Micro Torsional Actuator (마이크로 비틀림 구동기의 폐루프 피드백 제어에 관한 연구)

  • Choi, Won-Seok;Kim, Kun-Nyun;Jee, Tae-Young;Park, Hyo-Derk;Heo, Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1923-1925
    • /
    • 2003
  • 본 논문은 유리 기판과 실리콘 기판의 양극접합과 CMP공정을 통하여 정전기력으로 구동되는 마이크로 비틀림 액추에이터를 제작하고 이 제작된 액추에이터의 성능을 개선하는 방법과 실험에 관한 것이다. 이 비틀림 액추에이터는 미소 거울로 사용하기 위해 제작하였다. 미소 거울은 영상을 정확히 반사하거나 회절 시키는 것이 목적이지만 MEMS 공정의 특성 문제로 인해 일관적인 성능을 나타내는 것이 비교적 힘들다. 따라서 이를 개선하기 위해선 구조적인 접근 보다 실제 구동될 때의 현상을 보상하는 것이 필요하다. 일정한 입력전압에 비례하는 미소 거울의 변위를 알고 이를 기준으로 하여 시스템을 구동하여야 한다. 여기서 인가되는 전압에 비례하는 변위가 정확한지 측정을 해야 하고 만약 오차가 있다면 이를 개선하여야 한다. 또한 구동 시 발생하는 overshoot 현상과 작은 떨림 현상을 줄이고 빠른 시간 내에 응답하도록 시스템을 보상하여야 한다. 본 논문에선 PID 제어기법을 사용하여 $0.5^{\circ}$의 각도로 구동할 때를 기준으로 이 때의 구동전압 200V를 인가하고 오차를 측정하여 시스템을 보상하였다.

  • PDF

Effects of Surfactant PDFO on Photoluminescence of Porous Silicon (다공질 실리콘의 광발광에 관한 계면활성제 PDFO 효과)

  • Kim Buem-Suck;Yoon Jeong-Hyun;Bae Sang-Eun;Lee Chi-Woo;Oh Won-Jin;Lee Geun-Woo
    • Journal of the Korean Electrochemical Society
    • /
    • v.4 no.1
    • /
    • pp.10-13
    • /
    • 2001
  • Effects of an anionic surfactant pentadecafluorooctanoic acid on the photoluminescence of porous silicon was investigated, which was prepared by photoelectrochemical etching at 4V of single crystalline n-type silicon (100) with the specific resistivity of $0.4\~0.8{\Omega}{\cdot}cm$. Photoluminescence shifted to shorter wavelength and its intensity decreased when the concentration of the surfactant increased. FT-IR and contact angle data supported the presence of the surfactant lying on the surface of porous silicon.