• Title/Summary/Keyword: 앵커홀

Search Result 12, Processing Time 0.025 seconds

Nonlinear Analysis of Anchor Head for High Strength Steel Strand (고강도 강연선용 앵커헤드의 형상변화에 따른 비선형 거동특성 분석)

  • Noh, Myung-Hyun;Seong, Taek-Ryong;Kim, Jin-Kook
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.2
    • /
    • pp.163-173
    • /
    • 2012
  • This study covers the nonlinear analysis of anchor head for high strength prestressing strand and presents necessary process in improving the performance of anchor head. The surface of wedge for strand is contacted to the surface of the wedge hole on anchor head when it is fitted into the wedge hole, and the contact condition changes according to the level of load applied through the wedge. In order to analyze detailed behavior, nonlinear material model and contact element were used in analysis. It was found from the analysis that the behavior of anchor head is affected by the interaction with the wedge contacted so that the wedge in FE model should have the same figure as the actual object. Circular array of wedge hole presents better stress distribution than layer array even though the small difference in maximum deformation. Increment of thickness of anchor head and distance of wedge hole also improve the performance of anchor head.

Lateral Earth Pressures Acting on Anchored Retention Walls for Underground Excavation (지하굴착시 앵커지지 흙막이벽에 작용하는 측방토압)

  • 홍원표;윤중만
    • Geotechnical Engineering
    • /
    • v.11 no.1
    • /
    • pp.63-78
    • /
    • 1995
  • Recently, in order to utilize more effectively underground space, deep excavations have been performed on building or subway construction in urban areas. In such excavations, anchors have been used to support the excavation retaining walls because the anchored excavation could provide wide working space for underground construction. The purpose of this paper is to establish empirical equations to be able to estimate the earth pressures acting on anchored excavation retention walls, based on the investigation of field measuring results, which were obtained from twenty seven building construction sites. The prestressed anchor force was measured by load cells which were attached to the anchor head, while the horizontal displacement of excavation walls were measured by inclinometers which were installed right'behind the retention walls. The lateral earth pressures acting on the anchored retention walls, which were estimated from both the measured anchor forces and the horizontal displacement of the walls, showed a trapezoidal distribution. There was some difference between the measured earth pressures acting on the anchored retention walls and the empirical earth pressures given by several empirical equations. Thus, the lateral earth pressures acting on anchored retention walls would be estimated by these empirical equations with some modifications.

  • PDF

A study on reinforcement method of concrete structures using composite fiber panels (복합섬유 패널을 이용한 콘크리트 구조물의 보강공법에 관한 연구)

  • Kim, Woon-Hak;Hwang, Sung-Woon;Kang, Seok-Won;Kim, Jeong-Su
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2016.11a
    • /
    • pp.198-199
    • /
    • 2016
  • 기존 콘크리트 구조물의 내력 및 처짐에 저항하기 위하여 섬유시트를 사용한 복합섬유 패널 보강재를 셋 앵커를 이용하여 콘크리트 구조물과 일체화시키는 공법을 개발하였다.. 본 연구에서 적용된 실험 결과에 의하면 엥커+에폭시 보강 I 시험체가 기준시험체에 비하여 최대하중이 3.13배 증가, 동일 앵커갯수인 앵커보강시험체에 비하여 1.14배 증가하여으며, 에폭시보강시험체는 기준시험체에 비하여 최대하중이 3.08배 증가하였으나 계면에서 섬유박리로 인한 취성 파괴가 발생하였다.

  • PDF

Expansion Ratio and Ultimate Load of Pulse-Discharge Bulbed Anchors (펄스방전 그라운드 앵커의 확공특성 및 극한인발력에 관한 연구)

  • Kim, Nak-Kyung;Kim, Sung-Kyu;Joo, Yong-Sun;Seo, Hyo-Kyun;Kim, Sun-Ju
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.7
    • /
    • pp.5-10
    • /
    • 2009
  • The ground anchor is not usually used in soft clay and loose sand, because the pullout resistance of anchors can not be guaranteed. However, there is a method to increase the capacity of anchors using electric discharge geotechnical technologies, which are also known as pulse discharge and electric-spark technologies. The pulse-discharge anchor has a bulbed (or underreamed) bond length that is expanded by high voltage electrokinetic pulse energy. 24 anchors were installed in the weathered soil and sandy clay at the Geotechnical Experimentation Site at Sungkyunkwan University in Suwon, Korea. In this study, in order to define a relation between expansion rate of the anchor diameter and ultimate load, anchor load tests were carried out in accordance with testing procedures by AASHTO (AASHTO 1990) and FHWA (Weatheb 1998). And then several anchors were exhumed to measure the diameter of the pulse discharge anchors.

Multihop Range-Free Localization with Virtual Hole Construction in Anisotropic Sensor Networks (비등방성 센서 네트워크에서 가상 홀을 이용한 다중 홉 Range-Free 측위 알고리즘)

  • Lee, Sangwoo;Kim, Sunwoo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.1
    • /
    • pp.33-42
    • /
    • 2013
  • This paper presents a multihop range-free localization algorithm to estimate the physical location of a normal node with local connectivity information in anisotropic sensor networks. In the proposed algorithm, a normal node captures the detour degree of the shortest path connecting an anchor pair and itself by comparing the measured hop count and the expected hop count, and the node estimates the distances to the anchors based on the detour degree. The normal node repeats this procedure with all anchor combinations and pinpoints its location using the obtained distance estimates. The proposed algorithm requires fewer anchors and less communication overhead compared to existing range-free algorithms. We showed the superiority of the proposed algorithm over existing range-free algorithms through MATLA simulations.

Energy-Efficient Grid-based Hole-Detouring Scheme in Wireless Sensor Networks (무선센서네트워크에서 에너지 효율적인 그리드 기반의 홀 우회 방식)

  • Kim, Sung-Hwi;Park, Ho-Sung;Lee, Jeong-Cheol;Kim, Sang-Ha
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.4B
    • /
    • pp.227-235
    • /
    • 2012
  • Holes that generated by the unpredictable and harsh nature application environment or uneven energy consumption are an inevitable phenomenon in wireless sensor networks. Most of the existing schemes for this hole problem tend to use a static detour path to bypass a hole. The static detour path may lead to uneven energy consumption of the nodes on the boundary of the hole, thus it may enlarge the region of holes. At the same time, traffic would concentrate on the nodes on the boundary of the hole and tend to be depleted quickly. To solve this problem, we introduce energy-efficient grid-based geographic routing and hole-detouring scheme by taking advantage of grid anchor point in wireless sensor network with holes. The location of hole detour anchor node is dynamically shifted in grid cell. just generating dynamic hole detour paths to reduce total energy consumption. Simulation results are provided to validate the claims.

A Study on the Physical Behavior and the Applicability of Rock Anchorage System of a Suspension Bridge in Domestic Island (현수교 지중정착식 앵커리지의 거동특성과 국내 도서지역에서의 적용성에 대한 연구)

  • Yang, Euikyu;Choi, Youngseok;Choi, Kyungseob;Kim, Daehak;Jeon, Yongjun
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.2
    • /
    • pp.33-48
    • /
    • 2021
  • The rock anchorage of a suspension bridge is an outstanding anchorage type from environmental and economical perspective, although it should be applied when the bearing foundation is fresh enough to resist large cable loads. In practice, geotechnical engineers have encountered difficulties in designing the anchorage structure due to the fact that the physical behaviors of rocks against cable loads have not yet been fully proved and its design method was not established yet. In this study, model tests and numerical studies were performed to evaluate the behavior of the rock anchorage system planned under hard rock layers in domestic islands, and results suggest that the shape of asymmetric rock wedges can resist the tension loads with self weight and shear resistance. Additionally, real scale trial tests were carried out to verify the accuracy of an inclined drilling penetrating hard rock layers to install tendon to the bearing plate.

Developing an improved water discharge anchor & trap bolt to prevent basic salt penetration to harbor structures (해수 염기 침투방지를 위한 성능개선 형 물배출 앵커 및 트랩볼트 개발에 관한 연구)

  • Ock, Jong-Ho;Moon, Sang-Deok;Lee, Hwa-Sun;Shin, Kyung-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.674-682
    • /
    • 2018
  • Large industrial motors require a large area because of the high risk of shutdown accidents and large industrial accidents due to the lowering of the dielectric strength of the armature windings and overheating problems. Therefore, there is a demand for a large-capacity motor that has small size, light weight, and excellent dielectric strength compared with conventional motors. Superconducting motors have advantages of high efficiency and output power, low size, low weight, and improved stability. This results from greatly increasing the magnetic field generation by using superconductive field coils in rotating machines such as generators and motors. It is very important to design and analyze the cooling system to lower the critical temperature of the wires to achieve superconducting performance. In this study, a field loss analysis and low-temperature heat transfer analysis of the cooling system were performed through the conceptual design of a 100-HP high-temperature superconducting synchronous motor. The field loss analysis shows that a uniform pore magnetic flux density appears when high-temperature superconducting wire is used. The low-temperature heat transfer analysis for gaseous neon and liquid neon showed that a flow rate of 1 kg/min of liquid neon is suitable for maintaining low-temperature stability of the high-temperature superconducting wire.

Developing a water discharge anchor & trap bolt to prevent basic salt from penetrating to harbor structures (해수 염기 침투방지를 위한 항만구조물 보수보강용 물배출 앵커 및 트랩볼트 개발에 관한 연구)

  • Ock, Jong-Ho;Moon, Sang-Deok;Lee, Hwa-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.535-541
    • /
    • 2018
  • Most construction methods for the repair and reinforcement of old reinforced concrete harbor structures involve a process of applying a fiber complex or fiber complex panel just like wallpaper to the bottom of structures, such as slabs or beams. On the other hand, these techniques result in the sealing of repaired and reinforced portions of the structures by the fiber products, preventing moisture, such as rainwater entering the structures through the upper surfaces of the slabs or beams from being released, and causing the entire concrete covering of the structures to be peeled off in the long run. To prevent this, it is necessary to develop a technique to protect the basic salt from the sea water from penetrating into the structures while expelling the water absorbed in the structures swiftly. This study attempted to solve the problem by modifying the anchor bolts currently used to repair and reinforce the port structure. That is, by drilling holes into the body of anchor bolts and modifying the caps of the bolts to produce a structure that would let the water flow like a toilet trap, the moisture inside of the structure could be drained through the holes in the anchor bolts. The water discharge anchor bolts developed were tested and observed for 6 months; the water was discharged in 73% of the anchors (200 anchor installation, 145 anchors).

Group based DV-Hop localization Algorithm in Wireless Sensor Network (그룹 기반의 DV-HoP 무선 센서네트워크 위치측정 알고리즘)

  • Kim, Hwa-Joong;Yoo, Sang-Jo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.1A
    • /
    • pp.65-75
    • /
    • 2009
  • In Wireless Sensor Network, the sensor node localization is important issue for information tracking, event detection, routing. Generally, in wireless sensor network localization, the absolute positions of certain anchor nodes are required based on the use of global positioning system, then all the other nodes are approximately localized using various algorithms based on a coordinate system of anchor DV-Hop is a localized, distributed, hop by hop positioning algorithm in wireless sensor network where only a limited fraction of nodes have self positioning capability. However, instead of uniformly distributed network, in anisotropic network with possible holes, DV-Hop's performance is very low. To address this issue, we propose Group based DV-Hop (GDV-Hop) algorithm. Best contribution of GDV-Hop is that it performs localization with reduced error compared with DV-Hop in anisotropic network.