• Title/Summary/Keyword: 액위제어

Search Result 8, Processing Time 0.026 seconds

Development of an Assembly-type Liquid Level Control Experimental Equipment and a Hands-on Activity Task for Vocational High School 'Chemical Process Maintenance Operation' Subject (특성화고 '화학공정유지운영' 교과를 위한 조립형 액위제어 실험장치 및 체험활동과제 개발)

  • Jung, Eun-Suk;Lee, Kyung Taek
    • 대한공업교육학회지
    • /
    • v.45 no.2
    • /
    • pp.1-20
    • /
    • 2020
  • The purpose of this study is to develop an assembly-type liquid level control experimental equipment and a hands-on activity task that can be applied to the class so that students studying the chemical industry can easily understand the liquid level control. For this purpose, the content elements related to liquid level control in the chemical industry practice course of the 2015 revised curriculum was analyzed, a hands-on activity task with an assembly-type liquid level control experimental equipment was and developed. And then, expert verification was also performed and the hands-on activity task was applied to 19 students of S meister high school. The results obtained through this are as follows. First, the existing completion-type liquid level control experimental equipment was explored, and based on this, a new assembly-type liquid level control experimental equipment that can be assembled by students and used for practices was designed and manufactured. Second. by analyzing the contents of the NCS-based 'Chemical Process Maintenance Operation' practical course of the 2015 revised curriculum, learning contents related to level control were extracted. Among the contents related to the level control, the practice with understanding the process flow chart, manufacturing the level control experimental equipment, measuring the flow rate, and checking the level control phenomenon were conducted with the assembly-type liquid level control experimental equipment to systematically learn the level control.

Liquid Level System Realizing Van de Vusse Reactor Dynamics and its Control Experiments (Van de Vusse 반응기 동특성을 구현하는 액위시스템 및 제어 실험)

  • Lee, Jietae
    • Korean Chemical Engineering Research
    • /
    • v.58 no.2
    • /
    • pp.184-189
    • /
    • 2020
  • Van de Vusse reactors show the maximum points in input-output steady state maps and dramatic changes in their dynamic characteristics around those maximum points. According to their operating regions, there appear sign changes in steady state gains and nonlinear characteristics such as non-minimum phase dynamics which cause difficulties in applying controllers. Many nonlinear controllers that are available and newly designed are applied to these Van de Vusse reactor processes and their performances are tested. Reactor examples with real reactions have been reported. However, due to difficulties in constructing and operating chemical reactor systems, they are not adequate to be used for real applications of control experiments and hence most of results are based on simulations studies. Here, we propose a liquid level system that realizes most of the steady state and dynamic characteristics of Van de Vusse reactor, and two nonlinear control methods that can be used as base methods to compare nonlinear controllers newly designed. Liquid level experimental system and two nonlinear control methods are very simple and can be used to test performances of nonlinear controllers in practice.

Liquid level control in a spherical tank by microcomputer (마이크로 컴퓨터를 이용한 구형 탱크의 액위 제어)

  • Kang, Won-Young;Oh, Min;Lee, Tae-Hee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1986.10a
    • /
    • pp.459-462
    • /
    • 1986
  • The liquid level in a spherical tank was controlled with a micro-computer and the dynamic behavior of this non-linear system due to the variation of set point was studied. The adaptive control theory was used and the real values of controlled variables were compared with the theoretical values from a mathematical model.

  • PDF

Control Methods for Operation on the Saturation Edge (포화시작점에서의 운전을 위한 제어방법)

  • Ahn, Gwang Noh;Lim, Sanghun;Sung, Su Whan;Lee, Jietae
    • Korean Chemical Engineering Research
    • /
    • v.58 no.3
    • /
    • pp.390-395
    • /
    • 2020
  • For some processes with saturations, economical operating points are on the saturation edges. Traditional feedback controllers cannot be used to regulate such processes on the saturation edges because there are abrupt dynamics changes and no feedback information at saturations. Optimization-based methods such as the model predictive control can treat this control problem without difficulty when the saturation levels and dynamics are known and not varying. Otherwise, an adaptation scheme to track the saturation levels and dynamics should be included. Here, for very simple methods to treat this control problem, two control methods based on the recent slope seeking method and the relay feedback method are proposed. Their performances are evaluated with simulations applying them to a second order liquid level system with saturation. Simulations show that these proposed control methods can find and maintain operating point of the saturation edge under 5% relative error.

Level Dynamics and Control of the Solution in the High Temperature Generator of an Absorption Chiller (흡수식 냉온수기 고온재생기 액면 거동과 제어)

  • Shin, Young-Gy;Kwak, Min-Soo;Cho, Hyun-Wook;Nam, Sang-Chul;Jeong, Jin-Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.12
    • /
    • pp.852-858
    • /
    • 2010
  • In an absorption chiller, solution is circulated by a solution pump with an inverter to vary flow rate depending on operating conditions. For optimal operation, the solution level in the high temperature generator should be kept constant. However, a sensor for measuring continuous level is not available because of varying solution concentration. Instead, level switches are used and hence feedforward control associated with limit checking is a common practice. In the study, inverter frequencies are estimated from a dynamic simulation model and pump performance. Designed frequencies are compared with those implemented in real chillers. It was found that the frequencies used in real chillers are larger than those needed in circulation flow rates. It was intended to prevent system shut-off caused by dry-out. However, it is necessary to minimize the excessive frequency setting in order to reduce frequent pump stops and the range of solution level for continuous pump operation.

Adaptive predictive level control of waste heat steam boiler based on bilinear model (쌍일차 모델을 이용한 폐열 스팀 보일러의 액위 적응 예측 제어)

  • Oh, Sea-Cheon;Yeo, Yeong-Koo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.2 no.4
    • /
    • pp.344-350
    • /
    • 1996
  • An adaptive predictive level control of waste heat steam boiler was studied by using mathematical models considering the inverse response. The simulation experiments of the model identification were performed by using linear and bilinear models. From the results of simulations it was found that the bilinear model represented the actual dynamic behavior of steam boiler very well. ARMA model was used in the model identification and the adaptive predictive controller. To verify the performance and effectiveness of the adaptive predictive controller used in this study the simulation results of the adaptive predictive level control for waste heat steam boiler based on bilinear model were compared to those of P, PI and PID controller. The results of simulations showed that the adaptive predictive controller provides the fast arrival to setpoint of liquid level.

  • PDF

A Study on the Integrated Control and Safety Management System for 9% Ni Steel LNG Storage Tank (9% 니켈강재식 LNG 저장탱크용 통합제어안전관리시스템에 관한 연구)

  • Kim, Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.5
    • /
    • pp.13-18
    • /
    • 2010
  • This paper presents the development of an integrated control and safety management system for 9% nickel steel LNG storage tank. The new system added the measuring equipment of pressure, displacement and force compared to the conventional measurement and control system. The measured data has simultaneously been processed by integrating and analyzing with new control equipments and safety management systems. The integrated control and safety management system, which may increase a safety and efficiency of a super-large full containment LNG storage tank, added additional pressure gauges and new displacement/force sensors at the outer side wall and a welding zone of a stiffener and top girder of an inner tank, and the inner side wall of a corner protection tank. The displacement and force sensors may provide failure clues of 9% nickel steel structures such as an inner tank and a corner protection, and a LNG leakage from the inner tank. The conventional leak sensor may not provide proper information on 9% nickel steel tank fracture even though LNG is leaked until the leak detector, which is placed at the insulation area between an inner tank and a corner protection tank, sends a warning signal. Thus, the new integrated control and safety management system is to collect and analyze the temperature, pressure, displacement, force, and LNG density, which are related to the tank system safety and leakage control from the inner tank. The digital data are also measured from control systems such as displacement and force of 9% nickel steel tank safety, LNG level and density, cool-down process, leakage, and pressure controls.

A Study on Integrated Control and Safety Management Systems for LNG Membrane Storage Tank (멤브레인식 LNG 저장탱크용 통합제어안전관리시스템에 대한 연구)

  • Kim, Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.2
    • /
    • pp.40-46
    • /
    • 2010
  • In this study, the integrated control and safety management system for a super-large LNG membrane storage tank has been presented based on the investigation and analysis of measuring equipments and safety analysis system for a conventional LNG membrane storage tank. The integrated control and safety management system, which may increase a safety and efficiency of a super-large LNG membrane storage tank, added additional pressure gauges and new displacement/force sensors at the steel anchor between an inner tank and a prestressed concrete structure. The displacement and force sensors may provide clues of a membrane panel failure and a LNG leakage from the inner tank. The conventional leak sensor may not provide proper information on the membrane panel fracture even though LNG is leaked until the leak detector, which is placed at the insulation area behind an inner tank, send a warning signal. Thus, the new integrated control and safety management system is to collect and analyze the temperature, pressure, displacement, force and LNG density, which are related to the tank system safety and leakage control from the inner tank. The digital data are also measured from measurement systems such as displacement and force of a membrane panel safety, LNG level and density, cool-down process, leakage, and pressure controls.