• Title/Summary/Keyword: 압력 탱크(pressure tank)

Search Result 175, Processing Time 0.022 seconds

On the Prediction of Inner Pressure for the Tank in Rolling Motion (동요하는 탱크의 내부 변동압력 추정에 관한 연구)

  • Lee, Seung-Keon;Sea, Young-seok
    • Journal of Navigation and Port Research
    • /
    • v.27 no.5
    • /
    • pp.459-464
    • /
    • 2003
  • The inner liquid pressure of an airtight tank in rolling motions is investigated by means of forced oscillation tests, and the simple method to estimate the inner liquid pressure is proposed. A rectangular solid tank, which is fully filled with water, was used in the forced oscillation test of rolling motion. The inner pressure variations in time were measured at several points on the inner walls of tank. Measured pressures are compared with the calculated ones, and estimation methods of the inner liquid pressure of the tank in rolling motion are studied based on the considerations of the origin of pressure.

Internal Pressure Variation Analysis and Actual Holding Time Test on ISO LNG Tank Container (LNG 탱크 컨테이너의 내부압력 변화 분석 및 실제 홀딩타임 측정)

  • Ryou, Young-Don;Lee, Jin-Han;Jo, Young-Do;Oh, Young-Sam;Cha, Kyong-Ho
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.6
    • /
    • pp.1-7
    • /
    • 2013
  • Internal pressure variation analysis and actual holding time test on ISO LNG tank containers which were made in Korea for the first time according to the special notification of ISO tank container manufacture have been conducted during the transport demonstration projects of the tank containers by tractor, train and ship. The internal pressure of the LNG tank container increased rapidly after LNG filling and dropped during moving the container. However, it was stabilized as time passed and followed the liquid-vapor equilibrium graph. In addition, actual holding time of the tank container was more than 20 days which was satisfied with the special notification of LNG tank container manufacture.

The Improvement of Survivability of Fiber Brags Grating Sensors Embedded into Filament Wound Pressure Tanks (필라멘트 와인딩된 복합재료 압력탱크에 삽입된 광섬유 브래그 격자 센서의 생존율 향상)

  • Kang, D. H.;Park, S. W.;Park, S. O.;Kim, C. G.
    • Composites Research
    • /
    • v.18 no.5
    • /
    • pp.1-8
    • /
    • 2005
  • Among many fabrication methods of composite materials, filament winding is the most effective method for fabricating axis-symmetric structures such as pressure tanks and pipes. Filament wound pressure tanks are under high internal pressure during the operation and it has the complexity in damage mechanisms and failure modes. For this reason, it is necessary to monitor the tank through its operation as well as whole fabrication process. A large number of sensors must be embedded into multi points of the tank from its fabrication step for monitoring the whole tank. Fiber optic sensors, especially fiber Bragg grating(FBG) sensors are widely used for various applications because of good multiplexing capabilities. However, we need to develop the embedding technique of FBG sensors into harsh inner environment of the tank far the successful embedment. In this paper, we studied the embedding technique of a number of FBG sensors into filament wound pressure tanks considering multiplexing.

Comparison of the Internal Pressure Behavior of Liquid Hydrogen Fuel Tanks Depending on the Liquid Hydrogen Filling Ratio (액체수소 충전 비율에 따른 액체수소 연료탱크의 내부 압력 거동 비교)

  • Dongkuk Choi;Sooyong Lee
    • Journal of Aerospace System Engineering
    • /
    • v.18 no.3
    • /
    • pp.8-16
    • /
    • 2024
  • Because hydrogen has very low density, a different storage method is required to store the same amount of energy as fossil fuel. One way to increase the density of hydrogen is through liquefaction. However, since the liquefied temperature of hydrogen is extremely low at -252 ℃, it is easily vaporized by external heat input. When liquid hydrogen is vaporized, a self-pressurizing phenomenon occurs in which the pressure inside the hydrogen tank increases, so when designing the tank, this rising pressure must be carefully predicted. Therefore, in this paper, the internal pressure of a cryogenic liquid fuel tank was predicted according to the liquid hydrogen filling ratio. A one-dimensional thermodynamic model was applied to predict the pressure rise inside the tank. The thermodynamic model considered heat transfer, vaporization of liquid hydrogen, and fuel discharging. Finally, it was confirmed that there was a significant difference in pressure behavior and maximum rise pressure depending on the filling ratio of liquid hydrogen in the fuel tank.

The Development of Pressure Regulator of Propellant Tank for KSR-III (KSR-III 추진제 탱크 압력 조절용 레귤레이터 개발)

  • 정영석;조기주;조인현;김용욱;오승협
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.6 no.4
    • /
    • pp.47-58
    • /
    • 2002
  • The pressure regulator has been developed as a pressure-control device of propellant tank in KSR-III. The pressurization system of KSR-III is a basic pressurization system composed of pressurant, He tank and propellant tank. The pressure-control regulator is the most important part of gas-pressurized feed system along with He tank, pyrovalve and He fill valve. The first model of the regulator is tested to satisfy in leakage, strength and basic performance. The second model is tested in the overall test of the KSR-III propulsion system using water. From the test result of the second model, we conclude that the capacity of valve(Cv) must be increased in real system. The third model is modified and tested in the overall test of KSR-III propulsion system using propellant. Finally, the pressure-control regulator is qualified from firing test.

Design Characteristics of Resilient Blanket as Pressure Absorber in the Insulation Annulus of LNG Tank (LNG내외탱크 사이의 압력흡수용 탄성 Blanket 설계 특성)

  • Yun, Sang-Kook
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.4
    • /
    • pp.77-82
    • /
    • 2013
  • The construction of LNG storage tanks has been increased due to the expansion of LNG demand. LNG tanks which consist of an inner cylindrical 9%Ni metal tank and reinforced concrete, are insulated with perlite powder and resilient blanket for absorbing the perlite pressure in insulation annulus between two inner and outer tanks. This study tries to find out the design specifications and characteristics for blanket thickness and design pressure. The results show that the design basis for the blanket thickness should be approximately 30% to 40% of annulus width and the design pressure be applied below 2,200~2,700Pa with blanket thickness.

A Study on the Integrated Control and Safety Management System for 9% Ni Steel LNG Storage Tank (9% 니켈강재식 LNG 저장탱크용 통합제어안전관리시스템에 관한 연구)

  • Kim, Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.5
    • /
    • pp.13-18
    • /
    • 2010
  • This paper presents the development of an integrated control and safety management system for 9% nickel steel LNG storage tank. The new system added the measuring equipment of pressure, displacement and force compared to the conventional measurement and control system. The measured data has simultaneously been processed by integrating and analyzing with new control equipments and safety management systems. The integrated control and safety management system, which may increase a safety and efficiency of a super-large full containment LNG storage tank, added additional pressure gauges and new displacement/force sensors at the outer side wall and a welding zone of a stiffener and top girder of an inner tank, and the inner side wall of a corner protection tank. The displacement and force sensors may provide failure clues of 9% nickel steel structures such as an inner tank and a corner protection, and a LNG leakage from the inner tank. The conventional leak sensor may not provide proper information on 9% nickel steel tank fracture even though LNG is leaked until the leak detector, which is placed at the insulation area between an inner tank and a corner protection tank, sends a warning signal. Thus, the new integrated control and safety management system is to collect and analyze the temperature, pressure, displacement, force, and LNG density, which are related to the tank system safety and leakage control from the inner tank. The digital data are also measured from control systems such as displacement and force of 9% nickel steel tank safety, LNG level and density, cool-down process, leakage, and pressure controls.

Effect of Curing Temperature and Autofrettage Pressure on a Type 3 Cryogenic Propellant Tank (경화온도와 자긴 압력이 Type 3 극저온 추진제 탱크에 미치는 영향 연구)

  • Kang, Sang-Guk;Kim, Myung-Gon;Kong, Cheol-Won;Kim, Chun-Gon
    • Composites Research
    • /
    • v.19 no.4
    • /
    • pp.31-38
    • /
    • 2006
  • In this study, effects of curing temperature and autofrettage pressure on a Type 3 cryogenic propellant tank, which is composed of composite hoop/helical layers and a metal liner, were investigated by thermo elastic analysis and composite/aluminum ring specimen tests. Temperature field of a Type 3 tank was obtained from solving the heat transfer problem and, in turn, was used as nodal temperature boundary conditions during the elastic analyses for curing temperature and autofrettage pressure effects. As a result, it was shown that the higher curing temperature was, the more residual compressive stress and tensile stress were induced in composites and metal liner, respectively. On the contrary, autofrettage pressure brought the reduction of these residual thermal stresses caused by cryogenic environments to the tank structure. This tradeoff for curing temperature and autofrettage pressure must be considered in the design and manufacturing stages for a Type 3 cryogenic tank.

Analysis of Receiving sensitivity according to Contact Surface Change of Transmit-Receiver Ultrasonic Sensor for Fuel Level Measurement in CNG Tank (CNG 탱크 내 연료량 계측을 위한 송·수신 초음파 센서의 접촉면 변경에 따른 수신 감도 분석)

  • Kim, Nam-Wook;Im, Seok-Yeon;Choi, Doo-Seuk
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.4
    • /
    • pp.137-142
    • /
    • 2018
  • This paper is studied, as basic research for measuring the accurate fuel amount of the CNG tank by using the transmit-receive ultrasonic sensor, the receiving sensitivity according to changed the pressure inside the tank and the contact surface of the ultrasonic sensor is analyzed. Measurement was carried out while changing the contact surface of the tank and the sensor to three shapes of Point, Line, and Surface and charging the pressure in the tank at an interval of 1 bar from 0 bar to 5 bar. Experiment results, as the pressure in the tank increased the tendency of the received signal value of the ultrasonic sensor to decrease was confirmed. As the contact area between the tank and the sensor increased, the value of the received signal increased, but the noise also increased. The results of experiment, it is judged that accuracy can be improved by changing the contact surface of the sensor.

Design of Vent Relief Valve for Bi-level Pressure Setting of Oxidizer Tank (산화제 탱크 2단계 압력 설정을 위한 벤트/릴리프밸브 설계)

  • Koh, Hyeonseok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.1051-1053
    • /
    • 2017
  • We have designed the vent relief valve to set bi-level safety pressure for oxidizer tank. The minimum cavity volume was calculated to reduce the pressure deviation, and the valve operation characteristics was analyzed by using modeling. We have a plan to manufacture the validation model based on the analysis results.

  • PDF