• Title/Summary/Keyword: 압력 관

Search Result 1,035, Processing Time 0.03 seconds

Leakage Effect on the Exit Pressure in a Gas Pipeline (가스 파이프라인 내의 누출 현상이 출구 압력에 미치는 영향에 대한 연구)

  • Chang Seung-Yong
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.3 s.32
    • /
    • pp.27-33
    • /
    • 2006
  • This paper investigates leak effect on the outlet pressure at pipeline exit. A modified Weymouth equation(including inclination effect) was used for this study. To investigate leak effect, outlet pressure and ratio of outlet to inlet pressure were compared between no leak and leak conditions for horizontal, upward and downward flows, respectively. Then, effects of leak location as well as leak rate on the outlet pressure were also investigated for all pipeline inclinations.

  • PDF

A Theoretical Study on the Fluid-Structure Interaction Due to the Pump in the Pressurized Water Reactor (원자로에서 펌프에 의해 야기되는 유체와 구조물 상호 작용에 대한 이론적 연구)

  • Lee, Kye-Bock;Jong Ryul park
    • Nuclear Engineering and Technology
    • /
    • v.27 no.5
    • /
    • pp.710-720
    • /
    • 1995
  • The propagation of pump-induced pressure pulsation in a reactor is important because of the potential for vibration and resultant damage of reactor internals. A hydrodynamic model has been developed to obtain the pressure fluctuation due to the operation of pumps in the annulus(between the core support barrel and reactor vessel of a pressurized water reactor) including the coolant inlet pipe. The mathematical analysis is formulated in accordance with the linearized Navier-Stokes equation by assuming a compressible, inviscid flow. Two regions are considered separately and by coupling the solutions of the inlet pipe and the annulus, the inlet nozzle pressure(pressure at pipe and annulus interface) is to be calculated without assumptions. The geometric parameter effect on the pump-induced pressure pulsation is evaluated. Comparison of predicted and measured inlet nozzle pressure values for each forcing frequency shows good order of magnitude agreement.

  • PDF

Modular Modeling System(MMS)코드를 이용한 영광5,6호기 유출관계통에서의 과도현상 해석

  • 고용상;안장선;정장규;박병호;고득윤
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05a
    • /
    • pp.526-531
    • /
    • 1996
  • 영광5,6호기 유출관계통은 영광3,4호기의 유출관계통과는 달리 세개의 유출수 압력강하 오리피스 및 유출관 오리피스 개폐밸브론 이용하여 유출유량 및 압력을 제어한다. 새로이 설계 변경된 유출관계통의 성능 및 운전을 평가하기 위해서 Modular Modeling System(MME) 코드를 이용하여 분석을 수행하였다. 분석결과 배압제어기 제어변수의 계수선정이 계통의 과도현상에 매우 큰 영향을 미치고 있기 때문에 배압제어기 제어변수 선정이 계통의 과도현상 완화에 매우 중요한 인자임을 알 수 있었다. 그리고 배압제어기의 계수만 적절하게 선정되어 있다면, 유출관오리피스 개폐밸브의 Stroke 속도변화에 따른 계통의 과도현상에 미치는 영향은 거의 없음을 알 수 있었다. 또한 유출관오리피스 개폐밸브 특성이 선형인 경우가 Equal Percentage 특성을 갖는 경우 보다 과도현상 방지측면에서 우수하며, 배압제어기 제어변수의 계수만 적절하게 잘 선정된다면 유출관오리피스 개폐밸브의 운전에는 관계없이 계통의 과도상태를 적절하게 제어할 수 있다는 것을 알 수 있었다.

  • PDF

Pool Boiling Performance of Enhanced Tubes for the Generator of an Absorption Chiller (흡수식 냉동기 재생기용 고성능 전열관의 풀비등 성능)

  • Sim, Yong-Sub;Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.1684-1691
    • /
    • 2015
  • For performance improvement and compactness, usage of enhanced tube is inevitable. However, studies on enhanced tubes for generator is very limited. In this study, pool boiling tests were conducted for 7 heat transfer tubes. Test range covered pressure 7.38~101.3 kPa and heat flux $20{\sim}40kW/m^2$. Results show that boiling heat transfer coefficient increases as pressure or heat flux increases. Under atmospheric condition, high heat transfer coefficients were obtained for notched fin and low fin tubes(225% and 202% of the 19.0 mm smooth tube, which yielded the lowest heat transfer coefficient). As pressure decreased, high heat transfer coefficients were obtained for a low fin tube(290% and 288% of the 19.0 mm smooth tube at 12.34 and 7.38 kPa).

복합재 압력용기의 비파괴 시험과 평가

  • Jeong, Hyeon-Jo
    • Defense and Technology
    • /
    • no.10 s.164
    • /
    • pp.38-42
    • /
    • 1992
  • 복합재 압력용기의 제작 및 사용중에 발생하는 결함(손상)의 비파괴검사를 통해 구조물의 건전성을 평가하는 것은 제품의 품질보증 관점에서 아주 중요합니다. 복합재에서는 여러 종류의 결함이 동시에 존재할수 있으며, 결함-기계적 성질-비파괴특성 사이의 상호관계는 완전히 알려져 있지 않습니다. 이글에서는 복합재 연소관에 존재하는 결함의 위험도와 결함 탐지를 위한 비파괴 검사 기법에 대해 먼저 살펴보았습니다. Filament Winding으로 제조한 복합재 연소관의 Proof Testing과 관련해 음향방출(AE)법에 의한 최근의 연구결과를 살펴본 다음, 연소관의 신뢰도 확보를 위한 비파괴 평가 방법에 대해 앞으로의 연구 방향을 제시하였습니다

  • PDF

Design of Capillary Tube for a Refrigeration Systems (냉동시스템의 모세관 설계)

  • 정백영;함성훈;김태진
    • Journal of the KSME
    • /
    • v.33 no.11
    • /
    • pp.966-972
    • /
    • 1993
  • 모세관(capillary tube)은 일정면적식 팽창기구의 대표적인 것으로서 사용역사가 길고, 신뢰성이 높고, 가격이 저럼하므로 냉동공조시스템의 냉매제어장치로 매우 많이 사용되고 있다. 이것은 냉동시스템의 응축기와 증발기 사이에서 유입하는 고압의 액상냉매를 증발기에서 증발하기 쉬운 증발압력까지 압력을 강하시키는 감압팽창작용과 증발기의 증발 용량에 적당한 냉매 질량유량을 공급하는 역할 (이 작용은 냉동시스템의 용량과 작동범위를 결정하는데 매우 중요하다.)을 한다. 이 글에서는 모세관의 형상, 재질 및 그장 . 단점과 작동원리, 내부 유동현상 등 일반적인 사항에 관하여 기술한다.

  • PDF

Pressure-Loss Characteristics of an Asymmetric Bifurcation Model of Human Lung Airways (비대칭 인체 기관지 분지관의 압력손실 특성)

  • Kang, Min-Yeong;Lee, Jin-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.3
    • /
    • pp.301-307
    • /
    • 2012
  • The characteristics of pressure loss in an asymmetric bifurcating tube were investigated numerically for steady inspiratory conditions. The loss coefficient K calculated for various asymmetry and flow-distribution ratios found in human lung airways showed a power-law dependence on the Reynolds number (Re) and length-to-diameter ratio (L/d), with different exponents for Re $\geq$ 100 and Re < 100. The fundamental characteristics of the asymmetric bifurcation are similar to the case of symmetric bifurcation. In addition, the effect of skewed inlet velocity profiles on the pressure loss was weak, and decreased with an increasing number of bifurcations.

Nondestructive Examination of PHWR Pressure Tube Using Eddy Current Technique (와전류검사 기술을 적용한 가압중수로 원전 압력관 비파괴검사)

  • Lee, Hee-Jong;Choi, Sung-Nam;Cho, Chan-Hee;Yoo, Hyun-Joo;Moon, Gyoon-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.3
    • /
    • pp.254-259
    • /
    • 2014
  • A pressurized heavy water reactor (PHWR) core has 380 fuel channels contained and supported by a horizontal cylindrical vessel known as the calandria, whereas a pressurized water reactor (PWR) has only a single reactor vessel. The pressure tube, which is a pressure-retaining component, has a 103.4 mm inside diameter ${\times}$ 4.19 mm wall thickness, and is 6.36 m long, made of a zirconium alloy (Zr-2.5 wt% Nb). This provides support for the fuel while transporting the $D_2O$ heat-transfer fluid. The simple tubular geometry invites highly automated inspection, and good approach for all inspection. Similar to all nuclear heat-transfer pressure boundaries, the PHWR pressure tube requires a rigorous, periodic inspection to assess the reactor integrity in accordance with the Korea Nuclear Safety Committee law. Volumetric-based nondestructive evaluation (NDE) techniques utilizing ultrasonic and eddy current testing have been adopted for use in the periodic inspection of the fuel channel. The eddy current testing, as a supplemental NDE method to ultrasonic testing, is used to confirm the flaws primarily detected through ultrasonic testing, however, eddy current testing offers a significant advantage in that its ability to detect surface flaws is superior to that of ultrasonic testing. In this paper, effectiveness of flaw detection and the depth sizing capability by eddy current testing for the inside surface of a pressure tube, will be introduced. As a result of this examination, the ET technique is found to be useful only as a detection technique for defects because it can detect fine defects on the surface with high resolution. However, the ET technique is not recommended for use as a depth sizing method because it has a large degree of error for depth sizing.

레이놀즈수 변화에 따른 대기압 플라즈마 제트의 방전 특성 변화

  • Kim, Yun-Jung;Jin, Se-Hwan;No, Jun-Hyeong;Song, Seo-Jin;Lee, Ye-Gwon;Choe, Min-Seong;Kim, Hui-Ju;Gwon, Gi-Cheong;Jo, Gwang-Seop
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.240.1-240.1
    • /
    • 2014
  • 대기압 플라즈마 제트 장치에 주입되는 기체의 유량 변화에 따른 방전 특성을 유체역학적으로 해석하였다. 장치에 주입되는 기체의 유량 변화는 레이놀즈수에 의한 유체 흐름의 상태 변화와 베르누이 정리에 의한 압력 변화를 동반한다. 유리관에 주입되는 기체의 레이놀즈수가 Re<2000이면 층류이며 Re>4000이면 난류, 2000

  • PDF

The Electrical Breakdown Characterization of Gas Discharge Tube using Brass Electrode for Surge Protector (과전압 보호용 황동전극 기체방전관의 절연파괴 특성)

  • Kim, Min Il;Jeong, Euigyung;Lee, Sei-Hyun;Lee, Young-Seak
    • Applied Chemistry for Engineering
    • /
    • v.21 no.2
    • /
    • pp.205-210
    • /
    • 2010
  • In this study, a brass electrode gas discharge tube (GDT) was prepared to investigate its discharge characterization, which affects surge protection efficiency and lifetime of GDT. Discharge characterization of GDT using a brass electrode was investigated by changing applied voltage gradient and nitrogen gas pressure inside the GDT. As applied voltage gradient in GDT increased, electrical breakdown voltage and threshold energy largely increased and electrical breakdown time delay decreased. It was found that electrical breakdown voltage, electrical breakdown time delay, and threshold energy were largely decreased with decreasing the nitrogen gas pressure in GDT. As a result, electrical breakdown voltage, electrical breakdown time delay, threshold energy needed to be decreased to increase surge protection efficiency and lifetime. It was also found that the nitrogen gas pressure of GDT influenced strongly the performances as well as life span of it.