• Title/Summary/Keyword: 압력신호

Search Result 347, Processing Time 0.026 seconds

Development of the Emulator on Propulsion System (추진시스템 신호모사장비 개발)

  • Chung, Soon-Bae;Kim, Jung-Hoi;Park, Kon-Kuk;Kim, Young-Sam
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.431-432
    • /
    • 2008
  • In order to develop and inspect the electronic controller of propulsion system, It must emulate the electronic signal similar to actual signal. The applied signals on propulsion system are engine speed, turbine speed, various kinds of temperatue signal, pressure signal, LVDT/RVDT position signal and so forth. Contents are the development of emulator that simulate the electronic signals similar to actual signals.

  • PDF

Compensation of PPG signal distortion due to pressure using FSR sensors (FSR센서를 이용한 압력에 따른 PPG 신호 왜곡 보상)

  • Lee, Jae-Ho;Lee, Young-Jae;Lim, MinGyu;Park, HiJung;Lee, JeongWhan
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2013.01a
    • /
    • pp.281-282
    • /
    • 2013
  • 맥박을 측정하는 방법 중 하나인 PPG(photoplethysmography) 센서는 설계가 비교적 간편하며 사용이 편한 장점이 있지만, 움직임으로 인한 동잡음에 취약하다는 단점이 있다. 본 논문에서는 동잡음으로 인한 센서와 손가락 사이의 밀착되는 압력의 변화를 측정하여 왜곡된 신호를 보상하였다. PPG센서와 손가락 사이의 압력을 측정하기 위하여 FSR(force sensing resistor)센서를 이용하여 측정하였으며, 측정된 압력과 왜곡된 PPG 신호 비교를 통해 왜곡된 PPG신호와 FSR센서에서 얻은 압력 사이의 연관성을 확인하였고, 신호처리를 통하여 왜곡된 신호를 보상 시켰다. 이와 같은 방법으로 PPG신호를 보상하게 된다면 웨어러블한 환경에서의 적용뿐만 아니라 헬스케어로 응용이 가능할 것으로 보인다.

  • PDF

음향방출을 이용한 복합재 연소관의 건전성 평가

  • 이상호;최용규
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.32-32
    • /
    • 1997
  • 복합재 연소관의 구조적 건전성 평가 방법을 개발하기 위하여 표준 평가용 시편의 수압 시험 중, 연소관으로부터 방출되는 음향방출(acoustic emission: AE) 신호를 측정 장비를 이용하여 신호 처리함으로써 시편이 파괴되기 전, 대략적인 시편의 파열 위치 및 일정 압력 유지상태에서 hit rate 양상에 의한 건전성 평가 방법을 제시하였다. 데이터의 분석 기법 향상을 위하여 음향방출 데이터를 시간 및 센서별로 분류하는 프로그램을 개발하였다. 수압 시험을 낮은 압력 단계부터 높은 압력 단계까지 일정 압력 유지 상태(load-hold)에서 발생한 hit 수와 1분간 유지한 후 발생되는 hit rate(hit/sec)의 값의 크고 작음이 복합재 압력 용기의 결함수의 증감으로 나타났으며, 이로부터 복합재 압력 용기의 파열 압력과의 상관관계 및 건전성을 예측할 수 있었다. 복합재 압력 용기의 파열 위치는 energy rate(energy/sec) 측정값을 분석하여 예측하였으며, 파열 압력의 30∼50%에서 가능하였다.

  • PDF

증기발생기 전열관 sleeve레이저 보수용접을 위한 자동 확관장치의 구성

  • 김민석;백성훈;정진만;박승규;김철중
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05b
    • /
    • pp.561-565
    • /
    • 1997
  • 증기발생기 전열관 보수를 위하여 sleeve pipe를 삽입하여 레이저 용접을 하는 과정에서 전열관과 sleeve pipe 의 간격을 최소한으로 줄여 용접 품질을 높이고, 균등하게 하기 위하여 sleeve pipe에 대하여 확관이 수행된다. 확관은 sleeve pipe의 상단부와 하단부에 각각 수행되는데 정확한 확관규격을 유지하기 위하여 컴퓨터로 확관압력의 미분치를 비교분석하여 압력펌프를 제어하였다. 압력신호의 변화가 크고 안정되지 못하여 전후신호와 비교분석하여 안정화시킨 후 미분치를 추출하여 제어함으로써 전열관의 확관이 0.02mm 이내가 되도록 하여 전열관의 과도한 확관을 방지하였다.

  • PDF

Non-invasive estimation of the shock amplitude inside the body of the patient undergoing extracorporeal shock wave lithotripsy (체외 충격파 쇄석술 환자의 비침습적인 체내 충격파 압력 추정)

  • Choi Min Joo
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.389-392
    • /
    • 2002
  • 체외 충격파 쇄석술 (ESWL)은 인체 외부에서 발생된 충격파를 인체 내부의 결석 부위에 집속하여 결석을 분쇄하고 치료 효과를 얻는 혁신적 치료술이다. 충격파의 압력 및 파형은 결석의 분쇄 효과 즉 치료 효과를 좌우한다. 체외에서 충격파의 압력은 고감도 하이드로폰을 이용하여 측정할 수 있지만, 인체 체내에서, 특히, 비침습적으로 충격파를 측정하기는 매우 어렵다. 본 논문에서는 ESWL 충격파에 의해 활성화된 체내의 기포군으로부터 방출된 음향 신호 (CIAE)를 측정하여 비침습적으로 충격파의 압력을 추정하는 방법을 실험하였다. 충격파 압력의 추정은 측정된 CIAE 신호에서 1차 기포군 파열음과 2차 파열음 간의 시간 지연은 충격파의 압력과 선형적인 관련성 가진다는 실험 결과 (Coleman et al 1996)에 근거하고 있다. 본 논문에서는 충격파 압력 측정 시스템을 구성하여 생체 외 실험을 수행하였고, 개발된 시스템의 임상적인 활용 가능성을 확인하였다.

  • PDF

고리2호기 주급수차단밸브 구동용 질소 고압연동신호 제거

  • 윤덕주
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.10a
    • /
    • pp.392-397
    • /
    • 1997
  • 고리 2호기 주급수 차단밸브의 경우 다른 호기와는 달리 구동용 질소압력 측정스위치에 의한 닫힘 연동신호가 설치되어 있다. 이러한 연동신호는 벨브 구동용 반구내 질소 압력 스위치 "고" 오동작에 의한 밸브차단 가능성이 있으며 이 경우 질소압력스위치가 저/고 경보창에 COMMON되어 있어 원인 규명에 어려움이 있다. 또한 질소압력 스위치 고장 및 질소가스 누설시 작업수행이 어렵고 위험이 따른다. 이러한 70년대 발전소 설계의 과잉설비를 제거하므로서 최적운전과 경제성 향상에 기여할 수 있으며 아울러 유지정비의 용이성과 밸브 불시닫힘을 미연에 예방할 수 있으리라 예상된다. 이와 관련하여 발전소 계통안전성, 기기안전성을 평가한 결과 기존의 안전해석결과가 유효하며 또한 FSAR 수정없이 이러한 설비변경이 가능하다는 결론에 도달하였다.결론에 도달하였다.

  • PDF

High Frequency Signal Analysis of Oxidizer Pump for 7-tonf Turbopump (7톤급 터보펌프 산화제펌프의 고주파 신호 분석)

  • Bae, Joon-Hwan;Choi, Chang-Ho;Choi, Jong-Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.24 no.6
    • /
    • pp.61-68
    • /
    • 2020
  • 7-tonf turbopump real-propellant tests in Naro Space Center were conducted and high-frequency signals from an accelerometer and pressure sensors installed on the casing and the inlet/outlet pipeline of LOX pump were analyzed to estimate the structural and hydrodynamic stabilities. Waterfalls, frequency spectrums and RMS(Root Mean Square) values of the measured signals were calculated and characteristic instability frequencies by the rotating cavitation and the rear floating ring seal(F.R.S) were investigated. Static pressures of the inlet/outlet pipeline and an acceleration of the pump casing are strongly affected on pressure fluctuation induced by the rear floating ring seal in the leakage path. Despite the acceleration RMS value seems totally small, the rotating-speed-related synchronous frequency affecting the shaft instability is distinctly observed in the frequency contour.

Development of Insole Type Capacitive Pressure Sensor for Smart Gait Analysis (스마트 보행분석을 위한 깔창 형태의 전기용량성 압력센서 개발)

  • Woo, Hyunsoo;Min, Se Dong
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2012.07a
    • /
    • pp.411-412
    • /
    • 2012
  • 본 논문에서는 인간의 가장 기본적이며 기초적인 운동인 걸음걸이로부터 검출할 수 있는 걸음 수 및 보행분석을 위해 전도성 섬유를 이용한 전기용량성압력 센서를 깔창형태로 개발하였다. 개발된 깔창 형태의 센서는 보행시의 압력을 측정하여 보행신호를 검출하고, 검출된 신호를 이용하여 걸음 수 및 보행 분석을 실시하였다. 개발된 센서의 성능 검증을 위하여 상용 만보계 및 관찰자의 수계로 도출된 보수를 비교하였으며, 자세에 따른 압력차이를 측정하였다. 기존의 상용 만보계는 저속(1 Km/h)으로 걸었을 때 보수가 잘 측정되지 않은 반면 개발된 센서는 저속에서도 관찰자 수계대비 정확한 보수를 도출 할 수 있었다. 또한 자세에 따라 압력 값을 토대로 사용자의 자세를 모니터링 할 수 있음을 보였다. 본 연구는 향후 스마트폰과 무선 연동하는 스마트 보행관리 시스템을 개발하기 위한 기초연구이다.

  • PDF

Development of pressure measuring system for powered-wheelchair (전동휠체어 압력분포 측정시스템 개발)

  • Kil, S.K.;Lee, S.C.;Kim, T.W.;Hwang, J.H.;Hong, E.P.;Han, Y.H.;Lee, J.S.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.7 no.2
    • /
    • pp.109-115
    • /
    • 2013
  • In this paper, we developed pressure mesuring system for powered wheelchair and tried to validate the usefulness of developed system by pressure measuring experiment with 3D motion analysis. This system consist of 64ch seat FSR(Force Sensitive Resistance) sensor unit, 30ch*2 armchair FSR sensor unit, analog and digital hardware board, 2ch rotary encoder unit and realtime signal processing & display S/W. And each data acquired from this system has sampling frequency of 12bit, 10Hz. Pressure measuring experiment for 10 persons who use wheelchair in real life was performed in the 3D vision analysis room. From the experiment, we obtained result that the center line of body inclined to outside direction during powered-wheelchair rotate any direction.

  • PDF

마이크로볼로미터 IR 소자의 응답도 특성의 진공도 의존성 연구

  • Han, Myeong-Su;Han, Seok-Man;Sin, Jae-Cheol;Go, Hang-Ju;Kim, Hyo-Jin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.361-361
    • /
    • 2013
  • 비냉각 적외선 검출소자는 빛이 전혀 없는 환경에서도 사물을 감지하는 열상장비의 핵심소자이다. 마이크로볼로미터 적외선 검출기는 상온에서 동작하며, 온도안정화를 위해 TEC를 장착하여 진공패키지로 조립된다. 패키지는 진공을 유지할 수 있도록 일반적으로 메탈로 제작되며, 단가 감소 및 생산성 증대를 위해 wafer level packaging 방법을 이용한다. 마이크로볼로미터의 특성은 패키지의 진공 변화에 매우 민감하다. 센서의 감도를 증가시키기 위해서는 진공환경을 유지해야 한다. 볼로미터 소자의 특성은 상압에서 열전도는 기판과 멤브레인 사이의 에어갭을 통해 열손실을 야기하므로 센서의 반응도가 현저히 줄어든다. 에어갭이 1 um 정도 되더라도 그 사이에 존재하는 열전도가 가능하므로 진공을 유지하여 열고립 상태를 증대시킬 수 있다. 이에 본 연구에서는 소자의 동작시 압력, 즉 진공도가 볼로미터 소자의 반응도 특성에 미치는 영향을 조사하였다. 마이크로볼로미터 소자는 $2{\times}8$ 어레이 형태로 제작하였으며, metal pad를 각 단위셀에 배치하였으며, 공통전극으로 한 개의 metal pad를 넣어 설계하였다. 흡수체로써 VOx를 사용하였으며, 열 고립구조를 위해 2.5 um 공명 흡수층의 floating 구조로 멤브레인을 형성하였다. 진공패키지는 메탈패키지를 제작하여 볼로미터 칩을 TEC 위에 장착하였으며, 신호의 감지를 위해 가변저항을 매칭시켰다. 반응도는 신호 대 잡음 값을 획득하여 소자에 도달하는 적외선 에너지에 대해 반응하는 값을 계산에 의해 얻어내는 것이다. 픽셀 크기는 $50{\times}50$ um이며, 패키지 조립 공정 후 온도변화에 따른 저항 측정을 통해 TCR 값을 얻었다. 이때 TCR은 약 -2.5%/K으로 나타났다. $2{\times}8$의 4개 단위소자에 대해 측정한 값은 균일하게 TCR 값이 나타났다. 광반응 특성은 볼로미터 단위소자에 대해서 먼저 고진공(5e-6 torr) 하에서 측정하였으며, 반응도는 25,000 V/W의 값을 나타내었고, 탐지도는 약 2e+8 $cmHz_{1/2}$/W로 나타났다. 패키지의 압력 조절을 위해 TMP 및 로터리 펌프를 이용하여 100 torr에서 1e-4 torr의 범위에서 압력조절 밸브를 이용하여 질소가스의 압력으로 진공도를 변화시켰다. 적외선 반응신호는 압력이 증가함에 따라 감소하였으며, 2e-1 torr의 압력에서 신호의 크기가 감소하기 시작하여 5 torr에서 반응도의 1/2 값을 나타냄을 알 수 있었다. 30 torr 이상에서는 신호가 잡음값 과거의 동일하여 신호대 잡음비가 1로 나타남을 알 수 있었다. 또한 진공도 변화에 대해, 흑체온도에 따른 반응도 및 탐지도의 특성을 조사한 결과를 발표한다. 반응도의 증가를 위해 진공도는 진공도는 1e-2 torr 이하의 압력을 유지해야 함을 본 실험을 통해 알 수 있었다.

  • PDF