• Title/Summary/Keyword: 알칼리 레이저

Search Result 6, Processing Time 0.018 seconds

Numerical Analysis of High-Order Harmonic Generation in Alkalic Metal Ions (알칼리 금속 이온에서의 고차고조파발생에 대한 수치해석)

  • 김규욱;김용평
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.1
    • /
    • pp.39-44
    • /
    • 1995
  • 3차원 .delta.-potential을 가진 원자 모델을 이용하여 Nd:YAG(1064nm), Ti:sapphire(806nm), 색소(616nm), XeCl(308nm) 레이저를 기본파로 하고, 1차 이온화된 K/sup +/, Na/sup +/, Li/sup +/ 등의 알칼리 금속 이온을 비선형 매질로 할 때 고차고조파 분포를 수치적으로 해석하였다. 계산 결과 고차고조파 발생에서 특징적으로 나타나는 plateau는 비선형 매질의 이온화 에너지가 클수록, 기본파의 파장이 길수록 높은 차수에서 폭넓게 나타나고, 그 강도는 감소한다.

  • PDF

Light Amplification in Diode-pumped Cesium Vapor Cell (다이오드 펌프 세슘 원자 증기에서의 증폭)

  • Hwang, Jongmin;Jeong, Taek;Moon, Han Seb
    • Korean Journal of Optics and Photonics
    • /
    • v.29 no.6
    • /
    • pp.247-252
    • /
    • 2018
  • We report amplification of a small signal in a diode-pumped Cs vapor cell with 500 torr of ethane buffer gas, in the low-pump-power regime of 200 mW or less. For efficient amplifier operation, the pump and signal beams were coupled to a single-mode optical fiber, and completely overlapped in the Cs vapor cell. We investigated the amplification of the small signal according to cell temperature, signal power, and pump power. An amplification factor of 56 was achieved under the conditions of cell temperature of $115^{\circ}C$, signal power of 0.1 mW, and pump power of 200 mW.

Evaluation of LA-ICP-MS Whole Rock Trace Element Analysis Using Fused Glass Bead of Silicate Rocks (규산염 암석의 알칼리 용융 유리원판에 대한 LA-ICP-MS 전암 미량원소 분석법 평가)

  • Kim, Myong Jung;Kim, Taehoon;Park, Kye-Hun;Lee, Ye Ji;Yang, Yun Seok;Moon, Jeongjin
    • The Journal of the Petrological Society of Korea
    • /
    • v.24 no.2
    • /
    • pp.141-147
    • /
    • 2015
  • Using laser-ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), we evaluated the reliability of trace element abundance data measured from the silicate rock references of JR-3, JG-3, JGb-1 and JB-1b using glass discs made by alkali fusion. For 28 elements including rare earth elements, relative standard deviations (RSD) are better than 7% in case when the concentrations of the elements in the rock samples are greater than 10 ppm. However, RSD shows somewhat increased values for the concentrations less than 10 ppm, but never exceeds 25%. Compared with previously reported averages of the compiled abundance data, our data display satisfactory results for the most cases with differences less than 10%. We suggest that LA-ICP-MS analysis using fused glass beads is a reliable, precise and time-saving method of trace element analysis for the silicate rocks spanning from mafic to felsic compositions.

Study of the Variation of Optical Amplification Characteristics with Incident Beam Size and Temperature of a Cesium-vapor-based Optical Amplifier (세슘 원자 증기 기반 광 증폭기의 온도와 빔 크기에 따른 광 증폭 특성 연구)

  • Ryu, Siheon;Jeong, Yujae;Yeom, Dong-Il
    • Korean Journal of Optics and Photonics
    • /
    • v.32 no.6
    • /
    • pp.306-313
    • /
    • 2021
  • We study the amplification properties of an optical amplifier based on a cesium-vapor cell. An optical amplification system including cesium vapor mixed with a buffer gas is built, and its amplification feature is investigated as a function of the size of the incident beam and the temperature of the cesium-vapor cell. We observe that the optical amplification properties, such as amplification factor and extraction efficiency, change significantly depending on the temperature and beam diameter of the pump and seed light. A maximum extraction efficiency of 56% is obtained when the temperature of the cesium cell is 90 ℃, with a 200-㎛ diameter of the pump (500 mW) and seed light (10 mW). The numerical simulation of the amplification properties agrees reasonably with the results obtained from the experiment.

A Study on the Luminescence Properties of Eu3+ Ions Doped Vanadate (Eu3+ 이온이 첨가된 바나듐산염의 형광특성 연구)

  • Kang, Yeonhee;Yoon, Changyong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.445-451
    • /
    • 2019
  • The fluorescence intensity and fluorescence lifetime of $Ba_2GdV_3O_{11}$, a vanadate compound based on $Ba^{2+}$ ion, were investigated by adding $Eu^{3+}$ as a rare earth ion which is an alkaline earth metal, which is distributed around active ions and has a large influence on fluorescent properties when used as a host in a phosphor. $Ba_2GdV_3O_{11}:Eu^{3+}$ phosphor was synthesized by solid state method and the crystallinity of the phosphor was confirmed by X - ray diffraction analysis. The fluorescence properties of the $Ba_2GdV_3O_{11}:Eu^{3+}$ phosphor were measured using optical and laser. The energy transfer and diffusion of the $Ba_2GdV_3O_{11}:Eu^{3+}$ phosphor are highly dependent on the concentration of $Eu^{3+}$. When the concentration of $Eu^{3+}$ is low, it shows strong fluorescence to the CT band. However, as the concentration of $Eu^{3+}$ increases, the fluorescence due to 4f - 4f transition is strong. The concentration of $Eu^{3+}$ ion increased and the energy between ions was diffused, and the lifetime of fluorescence decreased. Energy transfer occurs between two $Eu^{3+}$ ions at low $Eu^{3+}$ concentration and energy diffusion occurs at high $Eu^{3+}$ concentration.

Rapid Detection of Radioactive Strontium in Water Samples Using Laser-Induced Breakdown Spectroscopy (LIBS) (Laser-Induced Breakdown Spectroscopy (LIBS)를 이용한 방사성 스트론튬 오염물질에 대한 신속한 모니터링 기술)

  • Park, Jin-young;Kim, Hyun-a;Park, Kihong;Kim, Kyoung-woong
    • Economic and Environmental Geology
    • /
    • v.50 no.5
    • /
    • pp.341-352
    • /
    • 2017
  • Along with Cs-137 (half-life: 30.17 years), Sr-90 (half-life: 28.8 years) is one of the most important environmental monitoring radioactive elements. Rapid and easy monitoring method for Sr-90 using Laser-Induced Breakdown Spectroscopy (LIBS) has been studied. Strontium belongs to a bivalent alkaline earth metal such as calcium and has similar electron arrangement and size. Due to these similar chemical properties, it can easily enter into the human body through the food chain via water, soil, and crops when leaked into the environment. In addition, it is immersed into the bone at the case of human influx and causes the toxicity for a long time (biological half-life: about 50 years). It is a very reductive and related with the specific reaction that makes wet analysis difficult. In particular, radioactive strontium should be monitored by nuclear power plants but it is very difficult to be analysed from high-cost problems as well as low accuracy of analysis due to complicated analysis procedures, expensive analysis equipment, and a pretreatment process of using massive chemicals. Therefore, we introduce the Laser-Induced Breakdown Spectroscopy (LIBS) analysis method that analyzes the elements in the sample using the inherent spectrum by generating plasma on the sample using pulse energy, and it can be analyzed in a few seconds without preprocessing. A variety of analytical plates for samples were developed to improve the analytical sensitivity by optimizing the laser, wavelength, and time resolution. This can be effectively applied to real-time monitoring of radioactive wastewater discharged from a nuclear power plant, and furthermore, it can be applied as an emergency monitoring means such as possible future accidents at a nuclear power plants.